elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Similar documents
UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

elite TM SERIES Centralized Emergency Lighting Inverters MODEL ELE

UltraLITE. Centralized Emergency Lighting Inverters MODEL ELU

UltraLITE MODEL ELU. Centralized Emergency Lighting Inverters

Spectron LSN (Life Safety Network) Suggested Specifications

SECTION POWER SUPPLIES AND DISTRIBUTION

Guide Specification Model CTG Automatic Transfer Switch

ILLUMINATOR EM. CENTRAL LIGHTING INVERTER 1000 VA/W through 2800 VA/W 98% Efficiency!

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

Central Emergency Lighting Inverter Systems

EON TM. 10 kw - 55 kw THREE PHASE. Centralized Emergency Lighting Inverters MODEL EL3

Light Support Power Systems CENTRAL EMERGENCY LIGHTING INVERTER SYSTEMS

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

1.1 RELATED DOCUMENTS: 1.2 DESCRIPTION OF WORK: 1.3 QUALITY ASSURANCE: 1.4 Warranty SECTION BATTERY EMERGENCY POWER SUPPLY PART 1 - GENERAL

APC BC300 Series 40kW 208/450/480V User Guide

Power Protection Solutions

CHAPTER 20 SERVICE EQUIPMENT

LORAIN CIP 4890/48120 DC Power System

AT10.1 Series Microprocessor-Controlled Float Battery Charger (single phase input)

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

LORAIN CSP DC Power System

SECTION LOW VOLTAGE LIGHTING CONTROLS

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

PART 4 ELECTRICAL STANDARDS

DGC-1000 DIGITAL GENSET CONTROLLER

SECTION AUTOMATIC TRANSFER SWITCHES

» EN50171» Lighting» Reliable

Liebert PPC Second Generation Power Distribution Cabinet

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

PowerWave 2 Busway System

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

HIGH BAY APPLICATIONS

B. Section Transfer Switches: Automatic transfer switch.

Mounting Kits. LWMB2 6" 6 3 /8" 5 7 /8" 2.6 lbs lbs. LCMB2 6" 5" 5 3 /4 2.3 lbs. 2.5 lbs.

DGC-500 DIGITAL GENSET CONTROLLER

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

SECTION INTERIOR LIGHTING

A. This Section includes the following lighting control devices:

Variable Frequency Drive SERIES MP800 VFD

FLOAT BATTERY CHARGERS

Across-the-Line SERIES MP300 Combined Manual and Automatic

Soft Start Series MP700 Solid State, Reduced Voltage

APS-Series 1500VDC OUTDOOR SOLAR INVERTER

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

PUMP CONTROL CENTER (PCC)

Autonomous control unit

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

APS-Series 1000VDC OUTDOOR SOLAR INVERTER

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Construction Electrical

SP40S-D. Kingfisher Company, inc. Features: Description:

SECTION LIGHTING CONTROL DEVICES

AS950 REFRIGERATED SAMPLERS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current

SECTION EMERGENCY POWER SYSTEMS

CONTENTS AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES

EVO192 v3.0 Fire and Burglary What s New

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

4100U City and Relay Cards Installation Instructions

A. This Section includes the following lighting control devices:

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

Addressable Fire Alarm Control Panel

SECTION LIGHTING CONTROLS

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

Environmental. Electrical Specifications at 25 O C TYPE HL E Output Constant Current. Output Voltage Range

MODEL B2 INSTALLATION MANUAL

DALI Interface Dimmable Electronic Ballasts for Fluorescent Lamps / Compact Lamps. Approvals:

Installation Guide for models:

Networked Access Control Panel. Installation Guide

Galaxy Pulsar Plus Digital Battery Plant Controller

CALTECH Pasadena, CA

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

DIESEL Engine Fire Pump Controllers Features

Installation Guide for models:

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

EMERGENCY POWERHUBB NODE INSTALLATION AND OPERATION GUIDE

Public Safety DAS Annunciator Panel

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Transcription:

5/25/16 rev 6 elite Model ELN General Specification 550 W to 1.5 KW elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems 1.0 General General Specification This specification describes the features and design of an uninterruptible, seamless transfer emergency lighting inverter power system. The ELN Series emergency lighting inverter system is designed to assure maximum reliability, serviceability and performance, and is designed for PFC electronic driver and/or ballast loading up to 50% of the rated output, and other lighting loads up to 100% of the rated output. The system incorporates a microprocessor controlled transistorized PWM inverter, high speed transfer devices, constant voltage regulating transformer, battery charging system, and 90 minute battery platform to provide immunity from all line disturbances and power interruptions with no break in AC output power. The system as described herein includes a normally on uninterrupted AC output power section and provision to include a normally off AC output power section, thus enabling compatibility with emergency lighting fixtures operating in normally on and standby operating modes. A self-diagnostic monitoring alarm system continuously advises of system status and battery condition. 2.0 Inverter Ratings Model ELN 550 ELN 1000 ELN 1500 Rating 550 Watts 1000 Watts 1500 Watts 3.0 Standards The system is designed in accordance with applicable portions of the following standards: A. American National Standards Institute (ANSI C57.110). B. Institute of Electrical and Electronic Engineers (IEEE 519-1992) and (C62.41-1991). C. National Electrical Manufacturers Association (NEMA PE-1). D. National Electric Code (NEC 2005) (NEC 2005, Article 700). E. National Fire Protection Association (NFPA 70, 101). F. Underwriters Laboratories (UL 924). G. Federal Communications Commission (FCC part 15, Sec. J, Class A). H. Listed UL Standards UL 924 Emergency Lighting Equipment, UL 924 Auxiliary Lighting and Power Equipment, UL 1778, C-UL 1778. 4.0 Input Specifications A. Input Voltage: 277 VAC or 120 VAC. B. Operating Range: +10% to -15% at full load without battery usage. C. Extended Range: The unit incorporates the use of variable range regulation in conjunction with the load percentage to extend the input range up to +10% to -40% without battery usage while maintaining a regulated, useable output voltage. D. Frequency Range: Capture 57.5 Hz to 62.5 Hz. E. Power Factor: Self correcting to >0.95. F. Input Harmonics: < 5% THD. G. Spike Attenuation: 3000:1. Page 1 of 5

5.0 Output Specifications A. Voltage: 120 VAC or 277 VAC. B. Sine Wave Voltage: Maximum 5% harmonic distortion under linear load. C. Crest Factor: 3.0 : 1. D. K Factor: 30 or better. E. Power Factor: Unity rated, KW=KVA. F. Harmonic Attenuation: Reflected load generated harmonics are attenuated 23dB at the input. G. Line Regulation: +3%. H. Load Regulation: Typically better than +3%. I. Isolation: NEC article 250-5d, complies with this standard that specifies a separately derived power source. 6.0 Battery Specifications A. Standard run times are 90 minutes at full kilowatt load, listed UL 924 Emergency Lighting Equipment. B. Battery Type: Integral, valve regulated, sealed lead calcium, maintenance free. C. Charger: 3 Amp, two stage. D. Recharge Time: UL 924, NFPA 101 compliant. E. Bus Voltage: 24 VDC, Float 2.27 VPC, final 1.75 VPC. 7.0 Performance Specifications A. Overload Capability: 125% for ten minutes. B. Surge Capability: 150% of rated output without need of static bypass. C. Frequency Stability: +0.2 Hz. D. Inner Winding Capacitance: 0.01 pf (primary to secondary coupling). E. Common Mode: 120 db (10 6 : 1 ground noise attenuation). F. Transverse Mode: 70 db (3160 : 1 line noise attenuation). G. Reactive Power Correction: Load at.6 pf corrected to > 0.95 at input (automatically correcting). H. Efficiency: 89% typical under full rated load. I. Loading Profile: Designed for PFC electronic driver and/or ballast loading up to 50% of the rated output, and other lighting loads up to 100% of the rated output. Page 2 of 5

8.0 Environmental Specifications elite Model ELN General Specification 550 W to 1.5 KW A. Operating Temperature: 0 C (32 F) to 40 C (105 F). B. Storage Temperature: -20 C to 50 C C. Relative Humidity: 95% non-condensing. D. Elevation: 5,000 feet, 1500 meters. E. BTU/HR Emitted, Weight, Cabinet Sizes: Wattage Rating BTU/HR Weight Dimensions W x D x H 550 409 344 lb. 31 x 16.6 x 39 1000 545 426 lb. 31 x 16.6 x 39 1500 614 510 lb. 31 x 16.6 x 39 F. Audible Sound Level: Not greater than 50 dba. G. Enclosure: NEMA 2, drip-proof for indoor use. Sealed, prohibiting rodent entry. H. Cooling: Forced air with air intake entry through screened bottom and slotted lower right side and air exit through slotted upper left side of enclosure. 9.0 Display Monitor and Diagnostics A. Display Panel Front mounted, sealed, alphanumeric LED display. Displays inverter input voltage, inverter output voltage, % load, and % battery as selected using display select push button. System display panel includes automatic visual indication status for system on, system on battery, low battery, and general alarm. Includes audible alarm for system on battery, low battery and general alarm condition(s). B. General Alarm Conditions (RS232) Communications port for access to general alarm conditions and electrical measurements. General alarm conditions include: Loss of AC input power, Low battery warning, frequency fault, check battery, shorted SCR, low battery shutdown, low output voltage, high output voltage, system overload, and system over temperature warning. C. Electrical Measurements (RS232) Communications port for access to electrical measurements and general alarm conditions. Electrical measurements include: AC input voltage, AC output voltage, output amps, % load, output watts, output va, power factor, input line frequency, number of power outages recorded from last clear function, and number of overloads recorded from last clear function. 10.0 Communications Interface A. Status / Alarm open collector transistor interface is provided for use with optional remote annunciator panel or automatic message dialer. Inverter on, utility AC power failure (system using battery power), low battery warning, and general alarm signals are included. B. Status / Alarm open collector transistor ratings: 40 VDC maximum, 300mA for use with optional remote annunciator panel or automatic message dialer or for use with customer s remote indicator. C. Power supply included for +/- 10 VDC, 1 ma. Page 3 of 5

11.0 Reliability A. MTBF Electronic / Electrical System: 100,000 hours. B. MTBF Transformer: 200,000 hours. C. MTTR: One hour. 12.0 Standard Equipment A. Hardwired input and output. B. Single PC board / control module design. C. Batteries (90 minute runtime at full rated load, listed UL 924 Emergency Lighting Equipment). D. Thermal magnetic AC input circuit breaker. E. DC battery fuse and Anderson connector with interconnect cable. F. Normally on uninterrupted AC output bus. G. Thermal magnetic output circuit breaker(s). H. Copper conductor construction. I. Local front mounted diagnostic monitoring display panel. J. Cabinet enclosure with hinged, lockable front door. 13.0 Optional Equipment A. Normally off AC output bus. B. Timed normally off AC output bus with field programmable timers. C. Additional pre-installed output circuit breakers for use with normally on AC output bus. D. Pre-installed output circuit breakers for use with timed normally off AC output bus. E. Automatic message dialer. F. Remote annunciator panel. G. Control device override. H. Zone sensing device. I. Output circuit breaker open / tripped alarm contacts. J. SNMP / TCP/IP Ethernet Adapter K. SNMP / TCP/IP / MODBUS TCP Adapter L. SNMP / TCP/IP / MODBUS TCP / MODBUS RS485 Adapter Page 4 of 5

14.0 Warranty A. All power components and system electronics are guaranteed to be free from defects in material and workmanship for a period 2 years. B. Batteries are warranted for 1 year full replacement, 14 years pro-rated. C. Optional extended warranty and maintenance contracts available. Page 5 of 5