Turbimax CUE21 / CUE22

Similar documents
Turbimax CUE21 / CUE22

Turbimax CUE21 / CUE22

for Drinking Water Systems

Signet 4150 Turbidimeter

Turb 2000 Series: Turb 2000 Turb 2020 Turb 2100 Turb 2120

WASTEWATER Online UV%Transmission Analyzer

Signet 4150 Turbidimeter

HYDROSENSE 3420 On-line Oil in Water Monitor. User Manual

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

DULCO turb C Measuring Device for Turbidity. Types: TUC 1, TUC 2, TUC 3, TUC 4. Assembly and operating instructions

OPTISENS TUR 2000 Technical Datasheet

OWNER S MANUAL CLX OnLine Residual Chlorine Monitor

* * Signet 4150 Turbidimeter. English. Description. Table of Contents Rev. P 03/15 Operating Instructions

Process Alarm Module RTA 421

Technical Information OUSTF10

Micro/Ultra Filtration System StamoClean CAT 430

Temperature Controllers

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

CLARITY II TURBIDIMETER

I/A Series 716C 1/16 DIN Temperature Controller

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

AquaLynx 200 ADX. Monitoring and Control System. Background. Operation

LC1350 Level Controller

Technical Information OUSAF21

OWNERS MANUAL. HF Oil Content Monitor (OCM)

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

MICRO 200 BW TURBIDIMETER RANGE OPTION NTU

SCHMIDT LED Measured Value Display MD Instructions for Use

Technical Information OUSAF12

Multi-Gas-Controller MGC2

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Oil-in-Water Monitoring. for. Marine and Industrial. Applications

BC3250. Blowdown Controller

Series 5000 Hydrazine Analyzer Model 60002

Operating Manual UV Monitor UVT 18

Apollo Intelligent Auto Aligning Beam Detector. User Guide

Technical Information OUSAF22

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

SECTION Fluorescent Dissolved Oxygen Measuring System

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

Dissolved Oxygen Measurement liquisys S COM 223 / 253

General Specifications

Krypton K CL2. Measuring and control system for free chlorine. applications. description. Low maintenance by automatic sensor cleaning

LCF Touch Modbus Datasheet Application Security Advice Caution

Process & TeMPerATUre UniversAl input DigiTAl MeTers

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

Technical Information OUSTF10

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Model D12-IR. Digital Gas Transmitter...

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Beam-A-Temp Portable Infrared Thermometer Measures up to 1832 F/1000 C with 50:1 distance to target ratio. Specifications

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

RS Pro Infrared Temperature Sensor

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Analog Room Pressure Monitor RPC Series

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

SPECIFICATIONS PARTICLE SENSOR KS-41B Higashimotomachi, Kokubunji, Tokyo , Japan

Series Temperature Controller Instruction Sheet

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

TEC2100 Series Networked Thermostats

ModBus DE-1 INSTALLATION AND USER MANUAL

CTT8 TEMPERATURE MONITOR DEVICE

Installation Manual Tracker 221

Rosemount 3490 Series

ROYCE SUSPENDED SOLIDS SYSTEM MODEL 7011A AND SENSORS MODELS 72A, 72P, 73B, 74A, 75A & 76A

Motorised Infrared Optical Beam Smoke Detector. User Guide

MultiMeter 44. Transmitter-regulator with 1, 2 or 3 channels. Quality at a reasonable price

Technical Information OUSAF44

Bristol Babcock Oil Content Monitor "oil in water"

DIGITAL PANEL METER N20 type

MXD75 Multi Channel Suspended Solids and Turbidity Transmitter

MO n : 12JMC rév A

3500/61E & 3500/67E Temperature Monitor

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

K 100 (W) DES. Disinfectant measurement. Applications. Description. Intuitive and simple menu Safety by password function. Disinfection.

64 Max IR Thermometer

Chillgard Refrigerant Monitor

EZT Series Integra Med Touch Area Alarm & Zone Valve Box with EZ Backfeed

Motorised Infrared Optical Beam Smoke Detector. User Guide

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

02/11/2015

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

02/11/2015

User manual. KNXgal. version

Tri-Tech Medical Inc.

TER Active Room Temperature Sensor (Controller),

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

Danfoss gas detection units

GasGard 100 Control System

MF-PFA ver 3.x. Micaflex PFA ver 3. Pressure- and Flow transmitter with alarmfunction. Installation- & Operation manual [Dok. id: mi-303gb_180528]

Transcription:

Technical Information Turbimax CUE21 / CUE22 Turbidimeter for on-line measurement Application On-line continuous monitoring of clean water: Drinking water Treated process water Your benefits Versions with white light source and infrared light source available Fast and easy calibration Complete primary calibration in less than minutes Verification in seconds Reduced calibration costs and quick response times thanks to low volume sample chamber Automatic continuous ultrasonic cleaning (Autoclean) increases cleaning intervals dramatically Simple modular design Easy to use and service Affordable thanks to modular microprocessor based technology Digital high-speed connections through RS-48 with Modbus Optional Features: Flow chamber for bubble suppression Reusable calibration kit TI39C/0/en/0.0 11808

Function and system design Measuring principle Measuring methods Turbidity measurement For turbidity measurement a light beam is sent through the medium and is diverted from its original direction by optically denser particels, e.g. solid matter particles. 90 WL scattered light method The measurement uses the standardised 90 scattered light method acc. to U.S. EPA 180.1. The turbidity of the medium is determined by the amount of scattered light. The transmitted white light beam is scattered by the solid matter particles in the medium. The scattered beams are detected by scattered light receivers which are arranged at an angle of 90 to the white light source. 90 NIR scattered light method The measurement uses the standardized 90 scattered light method acc. to ISO 02 / EN 202. The turbidity of the medium is determined by the amount of scattered light. The transmitted light beam with a wavelength in the near-infrared range is scattered by the solid matter particles in the medium. The scattered beams are detected by scattered light receivers which are arranged at an angle of 90 to the infrared light source. 90 scattered light method a0004442 Functions IR or white light measurement The Turbimax is available as infrared version, CUE21, to meet the design criteria specified in ISO 02 and DIN 202. The white light version, CUE22, meets the design criteria on turbidity measurement specified by the US EPA 180.1. Both versions have long life lamps. Backlit LCD The backlit LCD allows for easy readability in low light or no light conditions. The backlight is intended for continuous operation. The brightness can be adjusted in a menu in the CONFIG mode. Vapor purge The Turbimax is equipped with a continuous vapor purge system. A replaceable desiccant pouch in the lower portion of the instrument dries the air. System heat is used to warm the air. A fan inside the instrument continuously circulates heated dry air around the optical well and the flow through cuvette. This eliminates the need for a dry purge line. Alarms The Turbimax provides two relays that are designed to operate as two independent, programmable alarms. The alarms can be configured to activate when the measured turbidity level is higher or lower than the programmed alarm level for a given period of time. The alarm function also allows to set delay times. Ultasonic cleaning This option is used to continuously clean the flow through cuvette. It is not intended to clean already dirty cuvettes or to replace manual cleaning entirely. The system will increase the time between cleanings dramatically. Please note that the system requires the use of a special cuvette. 2

Turbimax CUE21 RS-48 outputs Turbimax has the capability to operate in two different RS-48 modes, a simple communication mode and Modbus protocol communication. The simple communication mode provides communication over programs such as the HyperTerminal that is included with most Microsoft Windows packages. You can also use Visual Basic or other programs. The default communication parameters are 8 bits, no parity and 1 stop bit. Modbus protocol communication is available for all models. The Modbus information is covered in a separate manual. Flow controller The flow controller limits the flow, in high-pressure systems, to safe flow limits of less than 1 liter/minute. Measuring system The Turbimax CUE21 / CUE22 measuring system comprises: Turbimax turbidimeter with installed cuvette and desiccant pouch Connecting tubing with fittings for flow through assembly shutoff clamp backpressure valve drain vent screw (in pressurized systems) Sensor interconnect cable 3 1 4 MODE EXIT E 2 8 9 Turbimax CUE21 system (example) 1 2 3 4 Shutoff clamp Intake tubing connection (for OD 8 mm (0.31"), ID 4. mm (0.19") tubing) Flowhead Backpressure valve Sensor interconnect cable 8 9 Drain vent Drain tubing connection (for OD 8 mm (0.31"), ID 4. mm (0.19") tubing) Emergency drain Field terminal box a000340 Input Measured variables Turbidity Measuring range CUE21: CUE22: 0 to 1000 NTU /FNU 0 to 100 NTU /FNU 3

Output Output signal Signal on alarm Load Communications port Relays 4 to 20 ma, galvanically isolated 2 ma in case of an error max. 00 Ω Bi-directional RS-48, Modbus optional Switching voltage: Switching current: max. 240 VAC max. 2 A Limit value and alarm functions Setpoint adjustment: CUE21: CUE22: Alarm delay: 0 to 1000 NTU 0 to 100 NTU 0 to 30 s Electrical connection Power supply Field terminal box 1 Power supply terminal block 2 Power cable strain relief 3 Power cable gland 4 Alarms terminal block, 240 VA, 2A 8 4 to 20 ma / RS48 terminal block Sensor wiring 4 to 20 ma / RS48 cable gland Alarm cable gland a000344 4

OUT IN Power supply 100 to 240 VAC, 4 to 3 Hz, 80 VA switching power supply Performance characteristic Response time Reference temperature Resolution adjustable 1 to 100 % (approx. to 00 seconds) CUE21: 0 to 1000 NTU CUE22: 0 to 100 NTU 2 C ( F) 0.0001 NTU (below 10 NTU) Maximum measured error below 40 NTU: above 40 NTU: ±2 % of reading or ±0.02 NTU whichever is greater ± % of reading Repeatability ±1 % of reading Installation Wall mounting Turbimax CUE21 / CUE22 is recommended for indoor use. When mounting the instrument note the following: Check that the temperature does not exceed the maximum permitted operating temperature range (0 to 0 C (32 to 122 F)). Leave a free area of approx. 0.20 m (8.00") above the instrument. This will ensure enough room for calibration and cuvette maintenance. Mount the instrument as close as possible to the sampling point to ensure a quick response time (within 2 to 3 m ( to 10 ft)). mm (inch) 131. (.14) mm (inch) 200 (8) M (¼ inch) OUT MODE EXIT Turbimax CUE21 E 0.8 (2.0) 20. (8.1) 90.1 (3) 34.1 (13.8) M4 (3/1 inch) 8.33 (3.438) 14. (.813) 30.1 (1.188) 1. (2.432) 19.8 (.) Mounting dimensions front view a000348 Mounting dimensions lateral view a000349

Environment Storage temperature Ingress protection -20 to +0 C (-4 to +140 F) IP / NEMA 4x Insulation rating Double insulated, pollution degree 2 Overvoltage protection Relative humidity Altitude Category II max. 9%, non-condensing up to 2000 m Process Process temperature Medium temperature range Process pressure Flow rate 1 to 0 C (34 to 122 F) 1 to 0 C (34 to 122 F) max. 13.8 bar (200 psi) controlled by integral pressure regulator 0.1 to 1 liter/min. (0.02 to 0.2 US.gal/min.) Mechanical construction Dimensions H x W x D: 34.1 x 20. x 19.8 mm (13.8" x 8.1" x.0") Weight Materials Light source 2 kg (4.4 lbs.) Housing: ABS Flow-through head: Nylon Sample cuvette: Borosilicate glass Sample cuvette seal: Silicon Flow-through fittings: Polypropylene Flow-through lock down pins: Stainless steel (AISI 304 or AISI 303) Inlet tube: Stainless steel (AISI 31) Turbimax CUE21: Infrared LED, 80 nm Turbimax CUE22: White light Tungsten lamp, ~00 nm, 220 K

Human interface Display and operating elements 1 2 3 AUTO Å00000 CAL..:. CONFIG 0000 OFFSET E MODE 4 EXIT 8 Display and operating elements 1 Display of turbidity levels and user guidance in configuration 2 Mode arrow to indicate instrument operating mode; AUTO (measurement), CAL (calibration), CONFIG (configuration) 3 Display of error messages and user guidance 4 MODE/EXIT key used to cycle between the three instrument operating modes Icon indicating the use of access code Icon indicating OFFSET mode F key to confirm an option or mode that is highlighted or chosen 8 V W keys used to change settings a000341 Certificates and approvals 4 symbol Declaration of conformity The product meets the legal requirements of the harmonized European standards. The manufacturer confirms compliance with the standards by affixing the 4 symbol. ETL approval Tested and passed ETL (tested to UL3111-1), 1 st Edition 1994, w/bulletin June, 199 Tested and passed ETLc (tested to CSA C22.2#1010.1-92) EMC compatibility Interference emission and interference immunity complies with EN 132: 199 / A1: 1998 Ordering information Turbimax CUE21 compact device, infrared Power supply A 100 to 240 VAC Output 1 4 to 20 ma or RS-48 Version A Standard CUE21- complete order code Turbimax CUE22 compact device, white light Power supply A 100 to 240 VAC Output 1 4 to 20 ma or RS-48 Version A Standard CUE22- complete order code

Scope of delivery The scope of delivery comprises: 1 Turbimax CUE21 / CUE22 turbidimeter 1 Field terminal box 1 Flow through assembly 1 Desiccant pack 1 Cuvette (single pack) 1 Tubing kit including 1 shutoff clamp 1 backpressure valve 2 connecting tubes with fittings for flow through assembly 1 drain vent screw (used in pressurized systems) 1 Operating Instructions BA39C/0/en Accessories Calibration solutions Ultrasonic cuvette Flow chamber Calibration kit CUE21 / CUE23 / CUE24, full range 0.02 NTU 10.0 NTU 1000 NTU Order no.: 11880 Calibration kit CUE22, full range 0.02 NTU 10.0 NTU 100 NTU Order no.: 1030102 Replacement cuvette with ultrasonic transducer allowing to use the ultrasonic cleaning feature Order no.: 118 Flow chamber CUE21 / CUE22 for air bubble suppression Order no.: 118 TI39C/0/en/0.0 11808 Printed in Germany / FM+SGML.0 / DT