POWER CONTROL CARD (MTC-3001)

Similar documents
DESCRIPTION. 42 mm. 125 mm

Alarms Manual. ver.1 rev.06/'07. Enclosures to Service Manuals of: McbNET Digital TM Magnum400 TM MiniMagnum400 TM. 6) Speeder One

ENV 06. Update Electronics Service Mode and Alarms

MSA. Electrolux Front Load Washer. MSA Training Presented by Marcone Servicers Association

SERVICE INSTRUCTIONS FOR. Fire Alarm System MINI-2000

Turn the power off, then back on. Reduce the number of registered blocks to 32. Check the cable connection.

Part 3 Troubleshooting

CAUTION: DISCONNECT ELECTRICAL POWER BEFORE SERVICING

DELOMATIC 400, DM-400 HYDRO

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

PIR movement and presence detectors 10 A

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Instrumentation Products and Applications

Simple Self-Diagnosis by Malfunction Code

A4 Manual Book. No. 15 Airport South Road, Jiaojiang District, Taizhou, Zhejiang, TEL: FAX:

ST Wiring diagram. Product description. Standard temperature controller. Order number

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

GMM Güntner Motor Management

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

Functional Safety Experience on Railway Signalling in Japan. Yuji Hirao Nagaoka University of Technology (Japan)

Chiller Manufacturer should have been manufacturing chillers utilizing magnetic bearing, oil free technology for more than 10 years.

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

MODBUS MESSAGING to the S5 BATTERY VALIDATION SYSTEM

Operating Manual MS220DA

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data.

FlexES Control Flexible solutions with the modular fire detection system

Annunciator Unit SACO 16 D1. Product Guide

The Next Generation Machine Protection System

Emotron M10 Shaft Power Monitor. Instruction manual English

INGECON SUN STORAGE 1PLAY

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

MAKING MODERN LIVING POSSIBLE INT INT EFIT 550. User Guide and Installation Manual. Danfoss Heating

E21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0

SERVICE-MANUAL INDUCTION COOKER BASE-LINE/FAJITA HEATER SH/BA 3500 FH

Applications and Examples

Fire control panels FC360

OPTICAL TIME DOMAIN REFELECTOMETER (OTDR): PRINCIPLES

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Fire control panels FC726 FC726-XA

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Danfoss gas detection units

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Technical manual NIBE AG-AA10 Single split air to air heat pump

FC700A Fire detection control unit

Multi-Gas-Controller MGC2

Galaxy Pulsar Plus Controller Family Troubleshooting Table with SMNP Traps

C-Bus Four Channel General Input Unit Installation Instructions

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

APC BC300 Series 40kW 208/450/480V User Guide

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

TPM Product Type 107-D108-XNT 64-channel digital output module with pluggable terminal

Cutting Edge Compressor Technology

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

Smart Combiners Installation Guide. For Obvius A89DC-08 sensor modules

Wired controller KJR-08B/BE. Run. Fault. TB Tot. Out. Query. Heat. Net-On. Turn-On Mode

INSTALLATION and OPERATING INSTRUCTIONS

Thank you for buying a DEVI product. With this purchase you have obtained a product of the highest quality, designed to give long lasting comfort at

Effective Alarm Management for Dynamic and Vessel Control Systems

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Sensing the World. When you have finished this lecture you should be able to:

Frequently asked questions: Intelligent Transmitter Series

OPERATING MANUAL Enertronic Control System 2

Features. Figure 1. Recommended Application

MSM - Expansion modules

2-wire Passive Intelligent Loop (LED) Display Meter

Construction Electrical

High Speed Door Albany RR300 Freeze

/9308 External Battery Chargers Installation Instructions

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

Product Specifications

The Impact of Marking Requirements. on Design and Performance of Power Converters and Electrical Drives

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

GE Fanuc Automation. Alpha Series Motors and Modular Drives. Computer Numerical Control Products. Maintenance Manual

SENTINEL D - Fault Passage Monitoring

Dryer Controller M720

Automation System TROVIS 5400 Ventilation Controller TROVIS Mounting and Operating Instructions EB 5477 EN. Electronics from SAMSON

OPERATION MANUAL Gas Alarm Processing Unit GAZ 203 VN VN 10

On the job around the clock 24/7: Fire detection systems

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

Incident resolution workflow

Packaging Machine Library offers solution!

EQ-ROBO Programming : Line tracer with 3 IR sensors

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

FB10000 Error Messages Troubleshooting

Building Technologies

SOFTWARE INTERFACE SPECIFICATION - SOLA MODBUS INTERFACE

NA G µair CONNECT 2

Using the HT46R48 in a Gas Water Heater Application

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

Bulletin 1608N MiniDySC Dynamic Sag Corrector

ni.com/manuals For specifications, refer to the NI USB-TC01 Device Specifications document available at ni.com/manuals.

Transcription:

Pag:1 Description Board with excellent dynamic features designed to control motors, obtaining high precision on low speed torque loop and speed. Its frontal part is make up of: Connexion with power stage through flat cable. Alphanumeric display to indicate the different stages of the equipment (power system alarms, control systems alarms, board configuration ) Direct entry with supply for differential encoder. Configurable outputs of optical fiber for the connexion of the board to a fast meter module. Application Net regeneration from a bus D/C for the realization of UPS, brakes... High precision electric drives for motor controlling D/C, controlled with torque loop and speed. Induction motor in vector control, with encoder and sensorless. servo brushless in torque loop and speed. Additional Data Tools Europe board format Alarms and warnings by jumps in the configurable references. Integrates software scopemeter which allows the visualization online of variables and parameters of the system with different shoots. Alarm historic management for an easy way of problem detection, with graphic storage of the parameters and variables of the equipment. Flat cable 26 PIN (connexion with power stage) Alphanumeric display 35 LED Do exist FBs (under codesys) for an easy use of the control. TPC/IP connexion through CPU MTC-3000. Fast meter board for high complexity tools. Graphic interface program for an easy configuration of the equipment and for a graphic visualization of the systems variables

Pag:2 ALARMS (NFS & CMS) The alarms for the new line are latched, must pass 6 seconds until the alarm could be reset. The fault alarms in the branches can acquire two different codes in the Pasaban Drives, having better information about the cause that produces the failure. If in the alphanumeric display of the appears the text E1, the cause of the alarm can be due to an extern cause or breakdown in the equipment, which will correspond with code 1 in the Pasaban Drives. On the other hand, if instead the mentioned code, we have 101, means that the equipment is breakdown. The codes from 1 to 15 (in bold), appear when the frequency converter has been previously working. The codes from 101 to 115, appear after giving the starting order and before producing it.(in case of an existing defect in the equipment) ALARM(s) HW BRANCH(s) 1 2 3 4 MTC- 3001 1 (101) Eu 2 (102) Ev 4 (104) Ew 8 (108) Et 7 (107) Ey 15 (115) Ez 3 (103) 5 (105) 9 (109) 11 (111) 13 (113) Ex 6 (106) 10 (110) 14 (114) 12 (112) Alarm 8 (STOP) This alarm is configured when a 10V is obtained in the hall effect transformer. Depending on the frequency converter model, the meaning of the alarm for the power stage differs NFS Model => Over temperature CMS Model => Over temperature Supply>19V Over current SW ALARM 20 Branch R 21 RMS Current Branch S 22 30 Over current Branch R 31 PEAK Branch S 32 Eb Ea Alarm 20...22 (STOP) By SW it s observed the area of the current that overcomes the RMS value of it. In case of overcoming the users prearranged value, the alarm appears. Alarm 30 32(STOP) By SW is observed when the current overcomes the motors peak value. If the values of the alarms Ea and Eb are really close, for a big motor is more possible an Eb, but if the motor is smaller is more possible an Ea. Depends on the motor. SW ALARMS 40 WD / CPU Ec 41 Faulty encoder Ed 42 Inverted turn Ee 43 Max speed reached Ef 45 Loss dot

Pag:3 Alarm 40 (STOP) The WD CPU alarm, appears if the frequency converter is started in local mode without disconnecting the WD (Starting process in local mode..) Alarm 41 (STOP) While the encoder is turning the impulses are read, and if the tolerance (adjustable by the user) differs from the characteristical pulses/turns of the pulses generator, it s considered that the encoder is faulty, giving the Ed alarm. Alarm 42 (STOP) Despite that by software has been annulled the inversion of the cutting-motor turn, if during a braking the master loses control, the slave is left with negative torque, therefore the cut would turn in the opposite direction. To that purpose the encoder movement direction is analysed and in case of being negative it stops the machine showing the Ee message. Alarm 43 (STOP) This alarm appears when the motor/frequency converter reaches a 200KHz frequency. The measurements in this frequency are not guaranteed. Alarm 45 (STOP) The frequency converter starts working wrong (PWM outputs of the frequency converter start switching off, in the display appears a dot )It s necessary to reset the controlling board to reco0ver the frequency converters configuration. V BUS ALARM MC-2001 50 High Eh UH 51 Low Eg UL Alarm 50 51 (STOP) They correspond to measurements done in the BUS DC and they are compared with superior and inferior limits prefixed by the user. ALARM JUMP IN THE REFERENCE MC-2001 120 Tension in mode Aa 121 Speed Ab 122 Acceleration compensation Ac 123 Torque Ad 124 Frequency Ae 125 Magnetizing current Af Alarm 120 125 (WARNING) The jumps produced in the speed, pair references don t produce the stopping alarm. If there is a sudden change in the reference, the alphanumeric display will inform about ir, and the jump will be integrated until the motor reaches the reference. During all the integration time, this alarms will be seen in the display. THEY DO NOT STOP THE FREQUENCY CONVERTER, THEY JUST INFORM ABOUT THE EVENT.

Pag:4 OPERATION WAYS The following table gathers the 11 operation ways in which the frequency converter control board can operate. Each working way has its alarms (120 125). Not all the alarms are operative in every way. WAY DENOMINATION 1 DC Motor in Opened loop DC-1 2 Speed loop DC-2 3 Torque loop DC-3 4 AC scalar motor in Opened AC-1 5 closed AC-2 6 Test mode F/V AC-3 independent 7 AC vector motor in Speed loop VM 8 Torque loop VS 9 Without use 10 Permanent magnet in Speed loop TM 11 Torque loop TS DC-1 DC-2 DC-3 AC-1 AC-2 AC-3 VM VS TM TS

Pag:5 COMENTARY MTC3001 1 (101) ALARM xxx DRIVER FAULT: ERROR IN TRANSISTOR BRANCH 1 Eu 2 (102) ALARM xxx DRIVER FAULT: ERROR IN TRANSISTOR BRANCH 2 Ev 4 (103) ALARM xxx DRIVER FAULT: ERROR IN TRANSISTOR BRANCH 3 Ew 8 (108) ALARM xxx DRIVER FAULT: OVERTEMPERATURE IN TRANSISTORS Et 7 (107) ALARM xxx DRIVER FAULT: OVERCURRENT (HARDWARE) Ey 50 ALARM xxx DRIVER FAULT: OVERVOLTAGE IN CAPACITORS Eh 51 ALARM xxx DRIVER FAULT: LOW VOLTAGE IN CAPACITORS Eg 20 Branch R ALARM xxx DRIVER FAULT: OVERCURRENT 21 Branch S (NOMINAL) 22 Eb 30 Branch R 31 ALARM xxx DRIVER FAULT: OVERCURRENT (PEAK) Branch S Ea 32 41 ALARM xxx DRIVER FAULT: NO SIGNALS FROM ENR Ed 42 ALARM xxx DRIVER FAULT: REVERSED ENR SIGNALS Ee 40 ALARM xxx DRIVER FAULT: WATCH DOG ERROR, NO REFERENCE FROM CPU Ec 15 (115) ALARM xxx DRIVER FAULT: NO 24V SUPPLY OR FLAT CABLE ERROR Ez 3 (103) 5 (105) 9 (109) 11 (111) 13 (113) 6 (106) 10 (110) 14 (114) 12 (112) ALARM xxx DRIVER FAULT: ERROR IN TWO OR MORE TRANSISTOR BRANCHES 43 ALARM xxx DRIVER FAULT: OVERSPEED Ef 44 ALARM xxx DRIVER FAULT: FATAL ERROR, CONTROL FRECUENCY TOO MUCH FAST Ei 45 ALARM xxx DRIVER FAULT: FATAL ERROR, CONTROL LOST Dot UNIDENTIFIED (this is programed in the codesys bloc) Ex XXX: Power suppliers name Alarms in Yellow: new alarms Alarms in Green: Programmed in the function bloc (codesys) for the power supplier alarms. Has an alarm but is not any of the programmed