Cooper Industries (UK) Ltd

Similar documents
Eaton is a global leader with expertise in:

Industries. As a premier global manufacturing company, we believe that great brands are

EFBW series - BiWire Ultra control panel

Conventional systems Product Name

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Emergi-Lite Orbis detectors

Menvier Fire System MF9300

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

System 800 Addressable Fire Detection & Alarm System

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

OPERATION AND INSTALLATION MANUAL

Installation, Operating and Maintenance Manual

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

Conventional Fire Detection

Xenex Conventional Fire Detection & Alarm System

4 wire conventional alarm system

Fire Product Catalog

Reflective Optical Beam Smoke Detector User Guide

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Intelligent addressable fire alarm control panel

Analogue addressable devices

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

The complete conventional fire warning system

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

MINERVA MZX125 Digital Addressable Fire Detection System

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

Addressable and Conventional Fire Protection

Conventional Leaflets

FEC400 Series. Installation Manual

CONTENTS NBM-06 Bell (6") Page 1

Control Panel Engineering and Commissioning Instructions

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

Door Release Power Supply

Fire Signalling. Signalling Solutions

Evolution Analogue Addressable Fire System

Sita200plus. 200detectors. Single loop analogue addressable System

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

5000 INSTALLATION GUIDE

The new detector from Rafiki

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

Intelligent Security & Fire Ltd

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

FIRERAY 5000 range USER GUIDE

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

HART XL High Sensitivity Smoke Detection

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

FEC403EN Installation Manual

An introduction to... Sigma

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Cooper Fire Systems. UL Listed Range

INTELLIGENT FIRE TECHNOLOGY

Conventional Smoke Detectors KFAPO

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Motorised Infrared Optical Beam Smoke Detector. User Guide

Conventional Fire Alarm System 2014 V1.2

Fire Signalling. Signalling Solutions

Installation Instructions 4 Zone Fire Panel

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Interface and EOL Modules 8

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Series 65 Product Guide MAN 3036

SISTEMAS DE SEGURIDAD MIRA, S.L. COMPANY & PRODUCT GUIDE

MINERVA MZX125. Digital Addressable Fire Detection System

Motorised Infrared Optical Beam Smoke Detector. User Guide

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

The supplier and installer of the system should be approved by the local civil defence authority.

Installation and user manual for the BiWire / Conventional Repeater Panel

Control Panel Engineering and Commissioning Manual (TO BE RETAINED BY THE COMMISSIONING ENGINEER)

Application, Installation, Operation & Maintenance Manual

INFINITY 8 INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Solution F2. Fire Alarm Control Panels one step ahead.

Touch Screen 1 loop Addressable Fire Alarm Panel

LF-4000 Series Conventional Fire Alarm Control Unit

D-Tect 2 GJD300 Quad PIR Movement Detector

MINERVA MX. 800 Series Ancillary Equipment

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Consultant Specification AGILE Wireless Fire Detection System

Intelligent Security & Fire Ltd

HART XL High Sensitivity Smoke Detection

Excel-EN Conventional Fire Control Panel

Reflective Beam Smoke Detector

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

Precept Marine Control Panel Application Guide

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

optical detector multisensor detector heat detector mounting bases product guide

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Interface Modules for SENTRI

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

DI601AM Outdoor PIR/AM Detector Installation Sheet

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Installation, Commissioning & Operating Manual

CONVENTIONAL CONTROL PANEL FL2/4/8/12 LT-XP

Transcription:

Menvier Fire Systems

Powering business worldwide As a globall diversified power management company, we help customers worldwide manage the power needed for buildings, aircraft, trucks, cars, machinery and businesses. Eaton s innovative technologies help customers manage electrical, hydraulic and mechanical power more reliably, efficiently fficiently, safe ely and sustainably.

We provide integrated solutions that help make energy in all its forms orms more practical and accessible. With 2012 sales of $16.3 billion, Eaton has approximately 103,000 employees around the world and sells products to customers in more than 175 countries. Eaton s electrical business Eaton is a global leader with expertise in: 1

Contents Conventional 3 Conventional Contents 5 Fire Panels 15 Detectors 17 Standard Base 19 Relay Base 21 Remote Indicator 23 Reflective Beam Detectors 25 Callpoints 27 Bells 29 Flush Sounders 31 Sounder and Sounder Beacon 35 Surface Sounders 37 Xenon Beacons 41 LED Beacons 45 Door Retainers Intelligent Addressable 47 Intelligent Addressable Contents 49 Fire Panels 61 Repeater Panels 65 Sensors 67 Standard Base 69 Sounder Base 71 Sounder Beacon Base 73 Loop Connected Remote Indicator 75 Reflective Beam Detectors 77 Callpoints 79 Wall Sounders 81 Wall Sounder Beacons 83 LED Beacons 85 Interfaces 97 Micro Interfaces Ancillaries and Test Equipment 103 Heavy Duty Relay Unit 105 Power Supply Unit 107 Loop Tester Kit 108 Addressable Device Programmer 2

Conventional Product Range Conventional Contents Page 5 Control Panels MF200, MF400, MF500 and Repeater Panel Page 31 Sounder and Sounder Beacon MDS824 and MDS824B Page 15 Detectors MPD821, MPT951, MFR830 MMT860 and MHT890 Page 33 Surface Sounders MWS424SB and MWS424DB Page 17 Standard Base MDB800 Page 35 Low Current Sounder MLC624 Page 19 Relay Base MDB800R Page 37 Xenon Beacons MXB124SB and MXB124DB Page 21 Remote Indicator CIR301 Page 40 Xenon Sounder Beacons MCD524SB and MCD524DB Page 23 Reflective Beam Detectors MBD50R and MBD100R Page 41 LED Beacons MLB124SB and MLB124DB Page 25 Callpoints MBG914 and MBG917 Page 43 LED Sounder Beacon MSB124SB and MSB124DB Page 27 Bells MBM246 and MWB824 Page 45 Heavy Duty Door Retainers MDR240 and MDR25L Page 29 Flush Sounders MFS324 and MFS324W 3

Conventional System Architecture The philosophy of a conventional system revolves around dividing the building into a number of areas called zones. The detectors and callpoints within each zone are then wired on dedicated circuits. In the event of a detector or callpoint being triggered, the panel is able to identify which circuit contains the triggered device and thereby indicate which zone the fire alarm has come from. It is then necessary to manually search the indicated zone to pinpoint the exact cause of the fire alarm. This increases installation complexity by forcing the sounder wiring to follow different routes to that of the detector wiring. When designing a conventional system it is important to ensure that the panel has adequate zone capacity for the size and complexity of the building and that the panel can support the intended sounder circuit wiring and loading. Unwanted Alarms Because most conventional detectors are simple two state devices they can only be in either a normal or fire condition. Although modern components and good system design can go some way to reducing potential problems, it is not uncommon for conventional systems to generate unwanted alarms due to certain operating conditions or transient environmental conditions such as the presence of steam near to a smoke detector. A key development aimed at reducing such unwanted alarms has been the multi-criteria detector. Traditionally, detectors were designed to respond to particular fire phenomena such as heat or the presence of smoke. However, Cooper now offer multi-criteria devices, which contain both a smoke sensing element and a thermal sensing element. The fire alarm decision is taken by analysis of the responses from both elements, resulting in improved detection performance as well as greatly enhanced false alarm suppression. Sounder Circuits In addition to the detection circuits, there is also a need for separate circuits of alarm annunciation devices such as sounders and beacons to signal the existence of a fire alarm condition to the building users. For sounder circuit continuity monitoring to function effectively, sounder circuits have to be wired in a single radial circuit, spurs and tees are not permitted. Almost every conventional fire panel will have facilities for more than one sounder circuit and generally the higher the specification of the panel or the higher the number of detection zones provided, the more sounder circuits will be provided. Normally however there will be less sounder circuits than detection zone circuits so it will be necessary for a sounder circuit to provide cover for more than one zone. 4

Conventional Product Control Panel Range- MF500 Series MF500 Series Control Panels Overview The 500 series fire panels provide a solution to any conventional system requirement. The panels are LPCB certified to EN54 parts 2 and 4 and offer an array of user and installer-friendly features at very competitive prices. The attractive flush or surface mountable plastic enclosure with plastic back box on the 2 and 4 zone panels and metal back box on the 8 and 16 zone versions have been designed through intensive voice of the customer research to provide ample space for termination of cables. System Overview The 500 series consists of a range of conventional fire alarm control panels designed in accordance with European standards BS EN54-2 and BS EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment. The range consists of 2, 4, 8 and 16 zone control panels. Supplied complete with battery for 24 hour standby Battery charger has temperature compensation as standard Matching 16 zone repeater panel All control panels have an integral, mains powered battery charger and power supply designed in accordance with the requirements of BS EN54-4 Features From 1 to 16 zones Built-in detector removal indication facility Conforms to requirements of BS5839 Part 4 Compatible for use on BS5839: Part 1: 2002 installations One-man test facility Non latching zone feature Class change input Earth fault monitoring Fully functional repeater available (16 Zone) 4 alarm circuits on 4-16 zone panels Fire and fault relays I.S Barrier selection by zone Flame resistant polycarbonate enclosure Surface or semi-flush mounting as standard Ample termination space 2 x 12V 2.1AH batteries (24hr standby) Short circuit fire by zone 5

Conventional Control Panel - MF500 Series Technical Specification MF5002 MF5004 MF5008 MF50016 2 zone control panel 4 zone control panel 8 zone control panel 16 zone control panel Standards EN54 Pt2 1998, A1:2006, EN54 Pt2 1998, A1:2006, EN54 Pt2 1998, A1:2006, EN54 Pt2 1998, A1:2006, EN54 Pt4 1998, A1:2002 + A2:2006 EN54 Pt4 1998, A1:2002 + A2:2006 EN54 Pt4 1998, A1:2002 + A2:2006 EN54 Pt4 1998, A1:2002 + A2:2006 Specification Number of Zones 2 4 8 16 Detectors per Zone 20 20 20 20 Number of Alarm Circuits 2 2 4 4 Alarm Circuit Load 400mA per circuit, 0.8A total 400mA per circuit, 0.8A total 400mA per circuit, 1.6A total 400mA per circuit, 1.6A total End Of Line Devices Detection circuits: EOLM-1 monitoring unit Detection circuits: EOLM-1 monitoring unit Detection circuits: EOLM-1 monitoring unit Detection circuits: EOLM-1 monitoring unit Alarm lines: 6.8kΩ resistor Alarm lines: 6.8kΩ resistor Alarm lines: 6.8kΩ resistor Alarm lines: 6.8kΩ resistor Auxiliary Fire Signal/Fault Output 5A 24V dc single pole changeover contacts 5A 24V dc single pole changeover contacts 5A 24V dc single pole changeover contacts 5A 24V dc single pole changeover contacts Auxiliary DC Output Yes Yes Yes Yes Repeater Port Optional Optional Yes Yes Mains Input Voltage 230V ac -15% +10% 230V ac -15% +10% 230V ac -15% +10% 230V ac -15% +10% System Operating Voltage 24V dc 24V dc 24V dc 24V dc Standby Duration 24 hours 24 hours 24 hours 24 hours Battery (Sealed Lead Acid) 1 x 2.1Ah 1 x 3.2Ah 1 x 3.2Ah 2 x 3.2Ah Recharge Period 24 hours 24 hours 24 hours 24 hours Environmental Operating Temperature -5 C to +40 C -5 C to +40 C -5 C to +40 C -5 C to +40 C Humidity (Non Condensing) 0 to 75% RH 0 to 75% RH 0 to 75% RH 0 to 75% RH Physical Construction Polycarbonate housing & back box Polycarbonate housing & back box Polycarbonate housing & metal back box Polycarbonate housing & metal back box Dimensions (H x W x D) Surface: 212mm x 260mm x 72mm Surface: 270mm x 332mm x 90mm Surface: 270mm x 332mm x 90mm Surface: 270mm x 332mm x 90mm Recessed: 279mm x 332mm x 122mm Recessed: 279mm x 332mm x 122mm Recessed: 279mm x 332mm x 122mm Weight 5.1kg 5.2kg 5.8kg 6.0kg Ingress Protection IP30 IP30 IP30 IP30 Cable Entry Top: 6x20mm entries with blanking plugs Top: 12x20mm entries with blanking plugs Top: 12x20mm entries with blanking plugs Top: 12x20mm entries with blanking plugs Rear cable entry aperture Rear cable entry aperture Rear cable entry aperture Rear cable entry aperture Dimensions W1 W2 D1 D2 H1 H2 W1 H1 D1 H2 W2 D2 Weight Total Width Total Height Total Depth Back Box Height Back Box Width Back Box Depth With Batteries 2/4 Zone 271mm 276mm 109mm 230mm 232mm 68mm 4Kg 8 Zone 375mm 276mm 108mm 232mm 335mm 68mm 6.6Kg 16 Zone 375mm 276mm 136mm 232mm 335mm 96mm 6.8Kg Product s MF5002 MF5004 MF5008 MF50016 Conventional 2 zone panel Conventional 4 zone panel Conventional 8 zone panel Conventional 16 zone panel 6

Conventional Control Panel - MF500 Series User Interface 1. Stylish and compact panel with 6 touch button keypad control of all functions and LED indication 2. Simple one-shot weekly test with auto-reset facility 3. Comprehensive power, fire, and fault LED indicators and integral piezo buzzer for on-board fire or fault indication 4. Battery high/low voltage alarm facility 5. Log book storage facility in front panel Detection Capacity 1. Up to 20 detectors per zone. End of line monitoring devices must be fitted and are supplied as standard 2. Detector circuits are monitored for open circuit, short circuit and detector removal Alarm Capacity 1. Two separate alarm lines on 2 and 4 zone panels 2. Maximum rated load of 400mA (2 and 4 zone) per line 3. Four separate alarm lines on 8 and 16 zone panels. 400mA maximum load per line 4. Alarm lines are monitored for open circuit and short circuit faults Interface Options 1. Class change input facility. Terminals provided for switching of alarm circuits to indicate school/college class change 2. 2 x1a 24V DC relays for Fire and Fault are available for remote signalling 3. Auxiliary 24V DC output power supply provided as standard on all panels Repeater Panel 1. Repeater matches the style and appearance of the main control panels 2. Facility for signalling to the Repeater panel provided as standard on 8 and 16 zone panels and optional for the 2 and 4 zone panels 3. Repeater requires only a single pair of wires to receive signals from the main control panel, plus local mains power supply, reducing the cost of installation 4. Displays essential information at other key locations in a large building/site Zone fire or fault conditions Zone or alarm lines in test mode Zone or alarm lines in disabled mode Alarm delays Fault isolations and test mode for control outputs System Functionality 1. Normal and supervisor mode facility. Supervisor mode protected by 4 digit security code to prevent unauthorised use 2. Supervisor mode provides access to test mode, where a one shot test facility can be initiated by the user. When in operation, the user has a period of time in which to put a call point into fire condition, after which the system automatically resets and returns to normal mode 3. Commissioning walk test feature permits the system to be easily tested after installation and prior to handover. The panel automatically resets and returns to normal operation after a detection device has been tested. Each device can then be tested in turn via the same procedure 3. Supervisor mode also provides facility to disable the following for maintenance or other purposes: Each detection zone independently The alarm circuits The fire/fault output 4. Non-latching zone facility is available as standard and can be programmable via Dil switches located on the display board 5. An Alarm Delay feature is also available and can be programmed via Dil switches located on the display board. Delay can be configured from 1 to 10 minutes as per the requirement of EN54-2 7

Conventional Control Panel - MF500 Series Panel Connection 2 & 4 Zone 1 1 2 3 2 3 EOLM-1 6K8 Resistor 6K8 Resistor 1 1 2 3 2 3 EOLM-1 230VAC OUTPUT Volt free normally open contacts EOLM-1 EOLM-1 L N E Mains 24V 0V NO C NC NO C NC - 1 + E - 2 + - + E - + E - + E - + E External 1 2 3 4 Power Class Fire Fault Zone Circuits Sounder Circuits Zone Circuits Supply Change Circuit Circuit 3 and 4 1 and 2 Out (4 Zone Version Only) Panel Connection 8 & 16 Zone 1 1 2 3 2 3 EOLM-1 6K8 Resistor 1 1 2 3 2 3 EOLM-1 Volt free normally open contacts EOLM-1 To Repeater Panel 230VAC OUTPUT 6K8 Resistors To EOLM-1 L N E Mains 24V 0V NO C NC NO C NC - 1 + - 2 + - 3 + - 4 + - 1 + - 2 + - 3 + - 4 + - 5 + - 6 + - 7 + - 8 + TX+ TX- - 9 + - 10 External Zone Circuits Power Class Fire Fault Zone Circuits 9 to 16 Sounder Circuits Supply Change Circuit Circuit 1 to 8 (16 Zone Out Panel Only) Repeater 8

Conventional Product Range Repeater Panel MF5000RP MF5000RP repeater panel Overview To complement the Menvier MF5000RP Series a repeater panel is available for connection to all zone panels. This repeater has been specifically designed for ease of installation requiring only 2 interconnecting wires from the main panel this compared with up to 16 wires on many conventional panels represents a large cost saving both on material and labour. Further repeater panels can be cascaded, again only using 2 wires. With stand by time not effected by the number of repeaters connected to each panel as each repeater has its own main supply and stand by battery. The repeater is suitable for up to 16 zones and displays all the same functions as the main panel, but with the addition of an indicator test facility. Features Facility for signalling to repeater panel provided as standard Charger with built in temperature compensation Displays essential information at other key locations in a large building/site Zone fire and fault conditions Test mode in operation Zones or alarm lines in disabled mode Benefits Repeater matches the style and appearance of the main control panel Repeater panel requires only a single pair of wires to receive signals from main control panel, plus local mains power supply, reducing cost of installation Cost saving 9

Fire 1 2 3 4 1 2 3 4 Conventional Repeater Panel - MF5500RP Dimensions Technical Specification H D W H (mm) W (mm) D1 (mm) D2 (mm) 212 260 45 77 MF5500RP Repeater Panel Specification Distance 2km Mains Input Voltage 230V ac -15%, +10% Standby Duration 24 hours Battery 1 x 12V 1.2Ah Recharge Period 24 hours Environmental Operating Temperature -5 C to +40 C Humidity (Non Condensing) 75% max Physical Construction PC Dimensions (H x W x D) 212mm x 260mm x 122mm Weight 3.6kg Ingress Protection IP30 Compatibility Suitable for use with JSB Conventional Fire Systems System Functionality 1. Supplied with integrated power supply and stand by battery 2. Provides local indication of essential information e.g fire, fault and disablement 3. Suitable for use with conventional control panels Device Overview 1. Supplied with integral power supply and standby battery Standard Connection MAX CABLE LENGTH 2km RECOMMENDED CABLE SIZE 1.00mm² L N E + - REPEATER OUTPUT CONNECTIONS L N E + - LINE INPUT CONNECTIONS + - LINE OUTPUT CONNECTIONS CONTROL PANEL (4 OR 8 ZONE) REPEATER PANEL Product s FXP5500RP Conventional Repeater Panel 10

Conventional Product Range MF200 and MF400 Range Control Panels MAR424 remote fire and fault relay PCB MF200 control panel MAR424 fits inside MF200 and MF400 panels Overview The Menvier MF200 and MF400 range of conventional control panels offer a competitive solution for smaller installations. Easy to install and operate, the panels are designed to provide fire detection and alarm facilities in buildings where the basic elements of protection to meet BS5839 are required. Available as either a 2 zone or 4 zone panel with up to 20 detectors per zone can be connected. This range of Menvier control panels are conveniently supplied complete with end of line devices and batteries offering 24 hours standby as standard, with the option of 72 hours on the 4 zone version. One man walk test and class change facilities, along with 24V dc remote signalling fire and fault outputs augment a value for money range. Features 2 or 4 zone panels Competitively priced Supplied complete with battery and end of line devices Benefits Simple end user operation One man walk test facility Fully compatible with Menvier range of ancillaries 11

Conventional Control Panels - MF200 and MF400 Technical Specification MF200 MF400 2 zone control panel 4 zone control panel Standards EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996 EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996 Specification Number of Zones 2 4 Detectors per Zone 20 20 Number of Alarm Lines 2 2 Alarm Circuit Load 375mA per circuit. 750mA total 375mA per circuit. 750mA total End of Line Devices Detection circuits: 22kΩ resistor Detection circuits: 22kΩ resistor Alarm lines: 22kΩ resistor Alarm lines: 22kΩ resistor Auxiliary Fire Signal Output 24V dc pull to 0V. Max 10mA 24V dc pull to 0V. Max 10mA Auxiliary Fault Output 24V dc pull to 0V. Max 10mA 24V dc pull to 0V. Max 10mA Auxiliary dc Output 24V dc fused. 32mA 24V dc fused. 32mA (up to 100mA at the expense of alarm load) (up to 100mA at the expense of alarm load) Mains Input Voltage 240V ac +10%-15% 240V ac +10%-15% System Operating Voltage 24V dc 24V dc Standby Duration 24 hours 24 hours (72 hours on MF400-72) Battery 1 x 4Ah sealed lead acid battery 1 x 4Ah sealed lead acid battery (1 x 7Ah on MF400-72) Recharge Period 48 hours (80% in 24 hours) 48 hours (80% in 24 hours) Environmental Operating Temperature -5 C to +40 C -5 C to +40 C Humidity (Non Condensing) 0 to 75% RH 0 to 75% RH Physical Construction ABS/Polycarbonate housing. Steel back box. ABS/Polycarbonate housing. Steel back box. Dimensions (H x W x D) 300mm x 300mm x 74mm 300mm x 300mm x 74mm Weight 4.8kg 4.8kg (6.0kg on MF400-72) Ingress Protection IP30 IP30 Cable entries Top: 10 x 20mm conduit entries Top: 10 x 20mm conduit entries Bottom: 1 x 20mm conduit entry (mains cable) Bottom: 1 x 20mm conduit entry (mains cable) Back: 1 x mains cable entry slot Back: 1 x mains cable entry slot Dimensions D W H (mm) W (mm) D (mm) 300 300 74 H Product s MF200 MF400 MF400-72 MAR424 MFALOG Conventional 2 zone control panel Conventional 4 zone control panel Conventional 4 zone control panel (72 hour standby) Conventional fire and fault relay PCB Fire alarm system log book 12

Conventional Control Panels - MF200 and MF400 Installation 1. A full set of Installation and user Instructions is supplied with each panel to assist the installer to carry out the work efficiently and safely, and the user to perform routine tests. 2. Panels are wall mounted via keyhole slot mounting holes on back of housing. 3. Mains power supply cable must be routed via the designated 20mm conduit entry on the top or bottom of the housing, or via the rear cable entry slot. The mains terminal block is provided with fuse protection. 4. A total of 10 x 20mm conduit entries are provided on the top of the housing for zone, alarm and output cables. Blanking plugs are supplied for unused entries. 5. Standby battery connected via push-on terminal connectors. 6. End of line (EOL) devices are supplied with the panel and must be fitted at the end of each detector and alarm circuit wiring. 7. Front cover retained by anti-tamper screws. System Functionality 1. Normal and supervisor mode facility. Supervisor mode protected by 4 digit security code to prevent unauthorised use. 2. Supervisor mode provides access to test mode, where zones can be tested individually. 3. One man walk test feature permits each manual callpoint and detector on the zone in test mode to be put into fire condition and activates the alarms for 2 seconds. Panel automatically resets the zone 10 seconds after each device has been tested. A fire condition received from a zone not in test mode results in an immediate alarm, overriding the test mode. 4. Supervisor mode also provides facility to disable/isolate the following for maintenance or other purposes each detection zone independently the alarm circuits the remote signal outputs User Interface 1. Attractive compact panel with easy to use 5 button keyboard to control all functions 2. Comprehensive power, fire and fault LED indicators and integral piezo buzzer for on-board fire or fault indication Interface Options 1. Class change input facility. Terminals provided for switching of alarm circuits to indicate school/college class change. 2. 24V dc outputs provided for remote signalling of fire and fault conditions. 3. Optional relay board available (MAR424) to convert fire and fault signals to volt free change over rated at 24V dc, 1A dc. 4. Auxiliary 24V dc output power supply provided as standard. Detection Capacity 1. Up to 20 detectors per zone. End of line monitoring devices must be fitted and are supplied as standard. 2. Detector circuits are monitored for open circuit, short circuit and detector removal. Alarm Capacity 1. Two separate alarm lines, each with a maximum rated load of 375mA. 2. Alarm lines are monitored for open circuit and short circuit faults. 13

Conventional Control Panels - MF200 and MF400 Standard Panel Connections MDB800 DETECTOR BASE MBG914/917 CALLPOINT connect as per instuctions END OF LINE 22KOhm RESISTOR + VE IN & OUT ON 1 - VE IN & OUT ON 2 subsequent zones END OF LINE 22KOhm RESISTOR subsequent alarm lines FAULT SIGNAL ISOLATING FIRE SIGNAL MAR724 MAR424 24V 10mA SWITCH /CONTACTOR/TIMER (APPLY NO VOLTAGE) 24V dc AUXILARY SUPPORT 24V dc 10mA PULL TO 0V + - E AUX FAULT / REMOTE SIGNAL AUX FAULT DOOR RELEASE UNITS RELAY OUTPUTS 240V dc 10A NC C NO NO C NC MAR724 24V 10mA COIL RELAY OUTPUTS 24V 1A (resistive) + - + - E AUX FAULT / REMOTE SIGNAL MAR424 + - E + - REMOTE SIGNAL C NC NO E E C NC NO + - E ZONE 1 + - E + - E + - E ZONE 2 ZONE 3* ZONE 4* + - E + - E ALARM 1 ALARM 2 + - E + - E AUX FAULT REM SIG + - E + - E CLASS CHANGE AUX DC 24V 10mA COIL + - E AUX FAULT 24V 10mA COIL + - E REMOTE SIGNAL * MF400 ONLY C = COMMON NC = NOT NORMALLY CONNECTED NO = NORMALLY OPEN 14

Conventional Product Range Detectors Optical / photo-thermal / heat detectors Innovative light pipe technology allows LED to be seen from any angle Overview The Menvier range of conventional detectors have been specifically designed to operate with Menvier control panels. The Menvier optical detector MPD821 is suitable for most applications giving the fastest response to slow burning or smouldering fires which give rise to large visible smoke particles. The Menvier photo-thermal detector MPT951 will respond quickly to fast clean burning fires yet maintain the advantage of optical detectors when detecting smouldering fires. The thermal enhancement of this detector allows a higher alarm threshold which provides a greater rejection of false alarms. The detector will also raise an alarm at temperatures exceeding 60ºC. The Menvier fixed heat detectors MMT860 and MHT890 will detect temperatures above 77ºC and 92ºC. The rate of rise heat detector MFR830 is used to detect rapid increases in temperature with a maximum threshold of 60ºC. These detectors are designed to be used in environments where the ambient conditions might cause false alarms if smoke detection were to be used, for example where there is a high level of dust, fumes, steam or smoke under normal conditions. Features Quick and simple to install Stylish low profile design 360º viewable LED Removable detector chamber Drift compensation Benefits Clean me feature means detector can be cleaned on site using the Menvier manual cleaning procedure Common mounting base Positive lock indication 15

Conventional Detectors Technical Specification MPD821 MPT951 MFR830 MMT860 MHT890 Optical smoke Detector Photo-thermal detector Rate of rise detector Fixed heat detector (77ºC) Fixed heat detector (92ºC) Standards EN54 Pt7 2000, A1 2002 EN54 Pt 5 & Pt 7 2000, A1 2002 EN54 Pt 5 2000, A1 2002 EN54 Pt 5 2000, A1 2002 EN54 Pt 5 2000, A1 2002 Supply Ratings Operating Voltage 15V dc to 30V dc 15V dc to 30V dc 15V dc to 30V dc 15V dc to 30V dc 15V dc to 30V dc Standby Current 30µA (max) 30µA (max) 30µA (max) 30µA (max) 30µA (max) Startup Current 340µA (max) 340µA (max) N/A N/A N/A Alarm Current 25mA (max) 25mA (max) 25mA (max) 25mA (max) 25mA (max) Fixing Information Mounting Position Ceiling in open areas Ceiling in open areas Ceiling in open areas Ceiling in open areas Ceiling in open areas Mounting Options Surface mount with MDB800 base Surface mount with MDB800 base Surface mount with MDB800 base Surface mount with MDB800 base Surface mount with MDB800 base Area Coverage 100m² (subject to local standards) 100m² (subject to local standards) 50m² (subject to local standards) 50m² (subject to local standards) 50m² (subject to local standards) System Wiring 2 Core 2 Core 2 Core 2 Core 2 Core Operation Detection Mode Light scatter principle Light scatter principle & Heat sensitive element Heat sensitive element Heat sensitive element Heat sensitive element Heat Class N/A A2S A2R BS CS Alarm Temperature N/A 60ºC 60ºC 77ºC 92ºC Indication 360º visible LED 360º visible LED 360º visible LED 360º visible LED 360º visible LED Environmental Operating Temperature -20ºC to 60ºC -20ºC to 45ºC -20ºC to 45ºC -20ºC to 60ºC -20ºC to 75ºC Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH 0 to 93% RH 0 to 93% RH 0 to 93% RH Physical Construction PC/ABS PC/ABS PC/ABS PC/ABS PC/ABS Colour White White White White White Dimensions Excl Base (Dia x H) 101mm x 33mm 101mm x 43mm 100mm x 43mm 101mm x 43mm 101mm x 43mm Dimensions Incl Base (Dia x H) 101mm x 45mm 101mm x 55mm 100mm x 55mm 101mm x 55mm 101mm x 55mm Ingress Protection IP40 IP40 IP40 IP40 IP40 EMC CE Marked CE Marked CE Marked CE Marked CE Marked Compatibility Suitable for use with Menvier conventional fire systems Menvier conventional fire systems Menvier conventional fire systems Menvier conventional fire systems Menvier conventional fire systems Dimensions Installation User Interface D Dia 1. Detectors are fixed and wired via common mounting base. 2. Cable entry into base can be rear or side. 3. A locking facility is provided which can be activated if required to prevent unauthorised detector removal without the use of a special tool. 4. Positive click mechanism incorporated to provide clear indication when detector is correctly located in base. 1. Red LED to indicate alarm condition. 2. Amber LED to indicate chamber fault/drift compensation limit (enhanced versions only). 3. All wiring connections are via a common mounting base (supplied separately). Dia (mm) D (mm) D (mm) (excl base) (incl base) Optical 101 33 45 Photo-thermal 101 43 55 Heat 101 43 55 Note: For wiring information please see MDB800 base. Product s MPD821 MPT951 MFR830 MMT860 MHT890 MDB800 MDP201 Conventional optical smoke detector Conventional photo-thermal detector Conventional rate of rise heat detector Conventional fixed heat detector (77 C) Conventional fixed heat detector (92 C) Conventional detector base Duct Probe 16

Conventional Product Range Standard Base MDB800 Suitable detectors for use with the MDB800 standard base MPD821 optical detector MDB800 standard base MPT951 photo-thermal detector MFR830, MMT860, MHT890 heat detectors Overview The MDB800 Menvier conventional base has been specifically designed to be compatible with the Menvier range of conventional detectors. This standard base has been designed for flexibility, simplicity and speed of installation. It incorporates purpose designed devices to provide fault warning if detector is removed whilst maintaining full zone wiring integrity. The base has a spring contact switch and a parallel zener diode to enable fault monitoring. Features Quick and simple to install Separate zone in and zone out terminals Stand off fixing feature Selectable detector locking Benefits Accepts side entry surface cables Common base for Menvier conventional detectors 17

Conventional Standard Base - MDB800 Dimensions Technical Specification D Dia (mm) D (mm) 104 22 Physical Construction MDB800 Standard base PC/ABS Colour White Dimensions (Dia x D) 104mm x 22mm Compatibility Suitable for use with Menvier conventional detectors Dia Installation Interface Options 1. Base incorporates a retaining clip to provide positive feedback when detector is correctly fitted. 2. Separate terminals are provided for zone in and zone out connections. 3. Each terminal can accept up to 2 x 2.5mm cables 4. Base incorporates a substantial cable entry aperture in the rear of the base. 5. Breakouts are provided to enable the detector base to sit neatly over surface cables and then enter via the rear entry aperture. 6. Base mounting incorporates a stand off feature to help prevent distortion when mounted on an uneven surface. 7. Fixings are suitable for standard BESA box or direct fixing to suitable surface 8. Optional locking devices (supplied with base) to prevent unauthorised detector removal. 1. Menvier conventional detectors and bases support the use of a remote LED (optional extra CIR301). Standard Connection + VE + remote indicator (optional) Compatible Menvier Conventional Control Panel -ZONE + 2 1 LED 3 E 4 2 1 LED 3 E 4 end of line resistor - VE WARNING: If using the outer connection on terminal 2, ensure the operation of the switch is not impeded and that there are no shorts between terminal 2 and the switch contact - use sleeves for end of line resistor. Ensure that cable or end of line resistor leg does not short onto the contact. Product s MDB800 Conventional standard base MDB800*10 Conventional standard base (pack of 10) CIR301 Conventional remote indicator 18

Conventional Product Range Relay Base MDB800R Suitable detectors for use with the MDB800R relay base MPD821 optical detector MDB800R relay base MPT951 photo-thermal detector Overview The MDB800R Menvier conventional relay base has been specifically designed to be compatible with the Menvier range of conventional detectors. This relay base has been designed for flexibility, simplicity and speed of installation. It provides a local relay signal in the event of its host detector being triggered, making it ideal for instigating a local response. Features Quick and simple to install Designed specifically for use with Menvier detectors Provides remote signal for external interfacing Benefits First fix mounting plate for ease of installation Local control output from host detector MFR830, MMT860, MHT890 heat detectors 19

Conventional Relay Base - MDB800R Dimensions Technical Specification Dia (mm) D (mm) 102 40 Specification MDB800R Relay base Relay Contact Rating 1A at 24V dc D Relay Trigger Source Detector remote LED output Detector Locking Facility Supplied as standard Physical Construction PC/ABS Colour White Dia Dimensions (Dia x D) 102mm x 40mm Compatibility Suitable for use with Menvier conventional detectors Installation 1. Relay base is supplied with a first fix fixing plate. 2. Fixing plate has a central cable aperture. 3. Cable entry is from rear. 4. Main body is then clipped into place on base, body locks into place when pressed into position. Interface Options 1. Bases are compatible with latest generation conventional Menvier detectors. System Functionality 1. Relay is controlled by status of host detector. 2. If host detector is triggered relay activates. Standard Connection + VE + remote indicator (optional) Compatible Menvier Conventional Control Panel -ZONE + 2 1 LED 3 E 4 2 1 LED 3 E 4 end of line resistor - VE WARNING: If using the outer connection on terminal 2, ensure the operation of the switch is not impeded and that there are no shorts between terminal 2 and the switch contact - use sleeves for end of line resistor. Ensure that cable or end of line resistor leg does not short onto the contact. Product s MDB800R Conventional relay base 20

Conventional Product Range Remote Indicator CIR301 CIR301 remote indicator Overview The CIR301 conventional remote indicator is designed to provide discreet remote indication for use with Menvier conventional detectors. The remote indicator is ideal for applications such as void spaces or outside locked or inaccessible rooms to provide indication of the activation of an automatic detector. Features Quick and simple to install Wide viewing angle high brightness LED Attractive styling Benefits High profile LED Fits onto standard single gang back box 21

Conventional Remote Indicator - CIR301 Dimensions Technical Specification D H (mm) W (mm) D (mm) 87 87 30 Environmental CIR301 Remote indicator Operating Temperature -10 C to +55 C H Humidity (Non Condensing) 0 to 95% RH Physical Construction ABS Colour White W Lens Colour Red Dimensions (H x W x D) 87mm x 87mm x 30mm Weight 0.28kg Ingress Protection IP30 Compatibility Suitable for use with Menvier conventional fire systems Standard Connection Installation System Functionality CIR301 Compatible Menvier Conventional Control Panel -ZONE + + VE 2 1 + LED 3 E 4 remote indicator (optional) 1. Mounting plate fixes to single gang back box or can be directly fixed to wall or ceiling. 2. Cable entry is normally from rear but breakouts are provided in side of base plate. 3. Cables connect to terminals on PCB within base plate. 4. Front cover is pushed onto base plate and locks in place. 1. The remote indicator is connected to an individual detector. 2. The remote indicator activates if detector is triggered. 3. LED cancels when detector is reset. 4. Low current consumption. - VE Compatible Menvier Conventional Control Panel DETECTOR BASE IN + - WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Terminal block unplugs for ease of connection Product s CIR301 M1R195B Conventional remote indicator Conventional remote indicator (with buzzer) 22

Conventional Product Range Reflective Beam Detectors MBD50R and MBD100R Optional mounting bracket with cable clamp facilities MBD50R and MBD100R reflective beam detectors Combined transmitter and receiver for ease of installation Overview The Menvier range of zone powered reflective beam detectors are specifically designed to be compatible with the full range of conventional Menvier control panels. Two versions are available, the MBD50R with a range of up to 50 metres, and the MBD100R with a range of 50-100 metres. Both of these units are extremely simple to install, they require no separate power supply, operate on a reflective principle and have a simple set up mode to enable easy and quick alignment during installation. Beam detectors are designed to replace individual point detectors in large open areas such as warehouses. Fire and fault conditions are signalled to panel using standard zone wiring so no additional interconnection is required. In normal operation only one beam detector may be connected per zone, however special versions are available to work with external power supply if multiple beam detectors are required to be connected to a single zone. Features Quick and simple to install Simple two wire connection No power supply required Benefits Single device to install instead of numerous point detectors Single point of maintenance Wall mounted for ease of maintenance 23

Conventional Reflective Beam Detector - MBD50R and MBD100R Dimensions Technical Specification H D W H (mm) W (mm) D (mm) 210 130 120 MBD50R MBD100R Reflective beam detector Reflective beam detector Standards EN54 Pt 12 2002 EN54 Pt 12 2002 Specification Operating Voltage 18V dc to 30V dc 18V dc to 30V dc Quiescent Current <5mA (no LEDs illuminated) <5mA (no LEDs illuminated) Alarm Current <9mA <9mA Alignment Current <18mA <18mA Power up Time 20 seconds (approx) 20 seconds (approx) Operating Range 5 to 50 metres 50 to 100 metres Tolerance to Beam Misalignment at 35% Detector ± 0.8, Prism ± 5.0 Detector ± 0.8, Prism ± 5.0 Fire Alarm Thresholds 2.50dB (25%) 3.74dB (35%) 6.02dB (50%) 2.50dB (25%) 3.74dB (35%) 6.02dB (50%) Optical Wavelength 880nm 880nm Environmental Operating Temperature -10 C to +55 C -10 C to +55 C Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH Physical Construction PC/ABS PC/ABS Colour White White Dimensions (H x W x D) 210mm 130mm x 120mm 210mm 130mm x 120mm Weight 0.8kg 0.8kg Ingress Protection IP40 IP40 Compatibility Suitable for use with Menvier conventional fire systems Menvier conventional fire systems Standard Connection MBD50R / MBD100R Installation 1. Must be fixed to solid structure. 2. Recommended mounting height is 0.3 to 0.6 metres below the ceiling. 3. Only 1 conventional reflective beam allowed per control panel zone, if multiple beams per zone required, special externally powered version available. 4. Cables can be terminated into separate termination box (not supplied) or use purpose designed mounting bracket (MRBFP) ordered separately. 5. Mounting bracket has facilities for glanding of incoming cables plus simple fixing of beam detector. 6. Test filter is supplied with detector to simulate required smoke obscuration level and confirm correct operation. System Functionality 1. Beam detectors have 3 modes Prism targeting mode designed to provide simple initial alignment of beam and reflector assembly. Alignment mode Enables accurate fine tuning of beam alignment without the need for additional calibration equipment or a second operator. Normal running mode User Interface 1. Beam detector status LEDs Red LED constantly illuminated indicates fire condition. Flashing amber LED indicates fault condition. Interface Options 1. Conventional beam detectors are connected directly to the Menvier conventional panel. Product s MBD50R MBD100R MRBFP Conventional reflective beam detector, 50m range Conventional reflective beam detector, 100m range Mounting bracket 24

Conventional Product Range Callpoints MBG914 and MBG917 MBG917 weatherproof callpoint MBG914 callpoint MBGHCC protective hinged cover Overview This attractively designed, simple to install, range of callpoints have been specifically developed to be compatible with Menvier conventional fire panels. There are 2 versions of callpoint in this range. The MBG914 which can be either surface or flush mounted and the MBG917 which is a weatherproof version. All callpoints are supplied as standard with a frangible glass element and a test key for ease of maintenance. A comprehensive range of accessories are available to maximise the functionality of the callpoint for particular applications. Features High visibility status LED Standard and weatherproof versions available Wide range of accessories Heavy duty terminals Benefits Quick and simple to install Fast fit clip on front cover Single tool for test and access MBGBEZ recessing bezel 25

Conventional Callpoints - MBG914 and MBG917 Dimensions H D H (mm) W (mm) D (mm) Flush mounted 87 87 36 Surface mounted 87 87 57 Weatherproof 87 87 59 W Technical Specification MBG914 MBG917 Surface/flush mount callpoint Weatherproof callpoint Standards EN54 Pt11 EN54 Pt11 Specification Operating Voltage 18V dc to 30V dc 18V dc to 30V dc Environmental Operating Temperature -10 C to +55 C -25 C to +70 C Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH Physical Construction PC/ABS PC/ABS Colour Red Red Dimensions (H x W x D) 87mm x 87mm x 57mm (36mm flush) 87mm x 87mm x 59mm Weight 0.2kg 0.2kg Ingress Protection IP42 IP65 Compatibility Suitable for use with Menvier conventional fire systems Menvier conventional fire systems Standard Connection MBG914 / MBG917 Compatible Menvier Conventional Control Panel COMMON 470Ω 4V7 + + - - - - WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable NOTE: 470Ω connection is for standard Menvier conventional panels. 4V7 connection can be used with MF9300 to enable certain features on the Menvier MF9300 range of control panels. Installation 1. Surface callpoint has standard rear BESA fixing facilities. In addition, back box can accept top or bottom surface entry cables. Surface callpoint can also be flush mounted. 2. Callpoint has test facility via special test key to prevent unauthorised operation. 3. Insertion of test key for test purposes and for cover removal is at bottom of callpoint to facilitate ease of access when mounted next to door architrave. 4. Test key is dual function, used to test callpoint operation by simulating activation and also to allow removal of clip on cover to gain access to element. 5. Element is held in place by clip on self locking cover which can only be removed by use of a special tool (callpoint test key). 6. Separate zone in and zone out terminals are provided for all connections. 7. Surface/flush callpoints are IP42, weatherproof is IP65. User Interface 1. To enable quick and simple installation, callpoints use a fast fit self locking clip on front cover which is very simple to fit, but once in place, can only be removed by use of a special key (supplied). 2. Callpoint is triggered by pressing against the element. Accessories Semi recess bezel Spacer plates Hinged clear cover Resettable plastic element Replacement test key Replacement glass elements Earth continuity links Product s MBG914 Conventional surface/flush callpoint MBG917 Conventional weatherproof callpoint MBGHCC Protective hinged cover MBGSP Spacer plates (pack of 10) MBGBEZ Recessing bezels (pack of 10) MBGREKIT Resettable element kit (pack of 10) MBG118 Spare break glasses (pack of 5) MBG119 Earth continuity links (pack of 5) MFBGKEY3 Callpoint keys (pack of 10) 26

Conventional Product Range Bells MBM246 and MWB824 MWB824 weatherproof bell MBM246 internal bell Overview Bells still remain a popular choice for many applications such as schools where they can sometimes be used as a signal for non fire purposes such as class change. MBM246 The MBM246 Menvier internal bell incorporates highly efficient rotary centrifugal movements combining high sound output with low current consumption. Features Quick and simple to install High sound output Low current consumption Multi-fixing base plate (internal) IP42 rated (internal) IP54 rated (weatherproof) Benefits Can be used for non fire applications MWB824 The MWB824 Menvier weatherproof bell enables a common bell sound to be achieved throughout a complete site, including areas where a weatherproof device is required. 27

Conventional Bells - MBM246 and MWB824 Dimensions Dia D Internal bell Dia (mm) D (mm) 6 inch internal bell 152 63 8 inch weatherproof bell 200 104 D Dia Weatherproof bell Technical Specification MBM246 MWB824 Internal 6 Inch bell Weatherproof 8 Inch bell Standards EN54 Pt3 EN54 Pt3 Specification Operating Voltage 24V dc 24V dc Current Consumption 25mA at 24V dc 28mA at 24V dc Sound Output 93-95dB(A) at 24V dc 95dB(A) (+/-2) Environmental Operating Temperature -10 C to +55 C -10 C to +55 C Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH Physical Construction gong - steel / base-polycarbonate stove enamelled Colour Red Red Dimensions (Dia x D) 152mm x 63mm 200mm x 104mm Weight 0.85kg 0.49kg Ingress Protection IP21C IP54 Cable Entry Rear Via separate back box Compatibility Suitable for use with Menvier conventional fire systems Menvier conventional fire systems Standard Connection MBM246 / MBM824 Compatible Menvier Conventional Control Panel - - + + WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable Installation MBM246 1. Multiple rear fixing options, can be fixed direct to wall or mounted on suitable BESA box. 2. Cable entry into bell is from rear. 3. Incorporates heavy duty terminals suitable for 2.5mm cables. MWB824 1. Supplied with heavy duty gasketed back box which supports bottom entry cables. 2. Incorporates heavy duty terminals. Device Functionality MBM246 1. Sound output is fixed and determined by size of the bell. 2. Operation is driven by an internal motor and striker arrangement. 3. Bells are polarised and suppressed. MWB824 1. Bell operates via solenoid. 2. Bell is polarised and suppressed. Product s MBM246 MWB824 Conventional internal 6 Inch bell Conventional weatherproof 8 Inch bell 28

Conventional Product Range Flush Sounders MFS324 and MFS324W MFS324W white flush sounder MFS324 red flush sounder Overview The Menvier discreet flush sounder is designed to be compatible with Menvier conventional fire systems. Available in a choice of colours MFS324 red and MFS324W white. These flush sounders provide an excellent combination of high sound output and discreet appearance. Ideal for retail, hotel and residential applications such as sheltered housing. Features Choice of colours Separate volume control Choice of tone is determined by selection of appropriate terminal for negative connection Benefits Quick and simple to install Low profile design 29

Conventional Flush Sounder - MFS324 and MFS324W Dimensions Technical Specification D W H (mm) W (mm) D (mm) 86 86 36 MFS324 MFS324W Flush sounder Flush sounder Standards EN54 Pt3 EN54 Pt3 Specification H Operating Voltage 6V dc to 28V dc 6V dc to 28V dc Current Consumption 20mA at 24V dc 20mA at 24V dc Sound Output 98dB(a) at 1 Metre (+/- 2) 98dB(a) at 1 Metre (+/- 2) Environmental Operating Temperature -25ºC to +55ºC -25ºC to +55ºC Humidity (Non Condensing) 0 to 95% RH 0 to 95% RH Physical Construction ABS ABS Colour Red White Dimensions (H x W x D) 86mm x 86mm x 36mm 86mm x 86mm x 36mm Weight 0.3kg 0.3kg Ingress Protection IP20 IP20 Cable Entry Via separate back box Via separate back box Compatibility Suitable for use with Menvier conventional fire systems Menvier conventional fire systems Standard Connection MFS324 / MFS324W Compatible Menvier Conventional Control Panel COMMON 1st SOUND 2nd SOUND + + - - - - Installation 1. Sounder fixes to a single gang deep back box. 2. Fixing screws included. 3. Connections are to main sounder body. 4. Separate loop in and loop out terminals are provided. 5. For surface mount applications a separate red single gang box can be ordered separately. Interface Options 1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit. WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable NOTE: Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal. Product s MFS324 MFS324W MFSSBB Conventional flush sounder, red Conventional flush sounder, white Back box, red 30

Conventional Product Range Sounder and Sounder Beacon MDS824 and MDS824B MDS824B sounder beacon with conventional detector and base MDS824 base mountable sounder MDS824B sounder beacon with blanking plate (MDS824COV) Overview The Menvier base mountable sounder and sounder beacon have a slim and aesthetically pleasing design and can be installed either as a discreet stand alone sounder / sounder beacon or ceiling mounted as shown, with detector and base. When mounted with a detector and base it simplifies the installation of the system by enabling a detector and sounder to be fixed at a single common point. When used as a stand alone sounder the device can be either wall or ceiling mounted and completed with an optional cover plate (MDS824COV). The sounder is ideal for applications such as hotel bedrooms or where a detector sounder / sounder beacon is required. Features Quick and simple to install Low profile design Discreet appearance Blanking plate available when used as a stand alone sounder Benefits Single installation point Can be wired as a stand alone unit 31

Sounder and Sounder Beacon - MDS824 and MDS824B Dimensions Technical Specification Dia Dia (mm) D (mm) 111 26 MDS824 MDS824B Sounder Sounder beacon Standards EN54 Pt3 EN54 Pt3 D Specification Operating Voltage 10V dc to 28V dc 10V dc to 28V dc Current Consumption 5mA (low) 7 ma (high) at 24V 7mA (low) 10 ma (high) at 24V Sound Output 80/90dB(a) (+/-3) @ 1 Metre 80/90dB(a) (+/-3) @ 1 Metre Light Output 1cd 1cd Environmental Operating Temperature -10 C to +55 C -10 C to +55 C Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH Physical Construction ABS ABS Colour White White Dimensions (Dia x D) 111mm x 26mm 111mm x 26mm Weight 0.4kg 0.4kg Ingress Protection IP30 IP30 Cable Entry Rear Rear Compatibility Suitable for use with Menvier conventional fire systems Menvier conventional fire systems Standard Connection Installation Interface Options MDS824 / MDS824B 2nd SOUND - - - 1st SOUND - + COMMON + 1. Sounder/beacon fixes to mounting surface. 2. Cables pass through the middle of the sounder. 3. Sounder/beacon wiring terminates at the sounder terminals. 4. Detector wiring terminates at normal connections on detector base. 5. If no detector is to be fitted, a blanking plate can be fitted instead. 1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit. Compatible Menvier Conventional Control Panel WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable NOTE: Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal. Product s MDS824 Conventional sounder MDS824B Conventional sounder beacon MDS824COV Blanking plate (pack of 5) 32

Conventional Product Range Surface Sounders MWS424SB and MWS424DB MWS424DB weatherproof surface sounder MWS424SB low profile surface sounder Low profile base Overview These general purpose conventional surface sounders have been specifically designed to work with Menvier conventional control panels. MWS424SB The MWS424SB is a low profile surface sounder. Volume is adjustable via the internal volume control and 32 different alarm tone selections are provided. Depending on the selected tone, sound levels of up to 105dB(A) can be achieved. MWS424DB The MWS424DB is a weatherproof (IP65) surface sounder. Volume is adjustable via the internal volume control and 32 different alarm tone selections are provided. Depending on the selected tone, sound levels of up to 105dB(A) can be achieved. Features MWS424SB Low profile design Pre drilled cable entries 32 selectable tones MWS424DB Weatherproof version (IP65) Choice of cable entry positions 32 selectable tones Benefits Low current, high sound output Suitable for a wide range of applications Automatic synchronisation Weatherproof base 33

Conventional Surface Sounders - MWS424SB and MWS424DB Dimensions Technical Specification D Dia Low profile surface sounder Dia (mm) D (mm) Low profile surface sounder 93 63 Weatherproof surface sounder 93 93 D Dia Weatherproof surface sounder MWS424SB MWS424DB Low profile surface sounder Weatherproof surface sounder Standards EN54 Pt3 EN54 Pt3 Specification Operating Voltage 9V dc to 28V dc 9V dc to 28V dc Current Consumption 16mA at 24V dc 16mA at 24V dc Sound Output 105dB(a) max (+/-2) at 24V dc 105dB(a) max (+/-2) at 24V dc Number of Tones 32 32 Environmental Operating Temperature -25 C to +70 C -25 C to +70 C Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH Physical Construction PC/ABS PC/ABS Colour Red Red Dimensions (Dia x D) 93mm x 63mm 93mm x 93mm Weight 0.24kg 0.3kg Ingress Protection IP54 IP65 Cable Entry Rear Rear/side Compatibility Suitable for use with Menvier conventional fire systems Menvier conventional fire systems Standard Connection MWS424SB / MWS424DB Compatible Menvier Conventional Control Panel COMMON 1st SOUND 2nd SOUND + + - - - - WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable NOTE: Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal. Installation MWS424SB 1. Supplied with simple to install first fix mounting base. 2. Fixing and cable entry holes are pre-drilled. 3. Cable entry is from rear. 4. Connections are to main sounder body. 5. Separate zone in and zone out terminals are provided. 6. Main body is pushed into sounder base and then twisted to lock into place. MWS424DB 1. Supplied with simple to install first fix mounting base. 2. To maintain weatherproof integrity, fixing holes are drilled upon installation. 3. Cable entry can be rear or side. 4. Connections are to main sounder body. 5. Separate zone in and zone out terminals are provided. 6. Main sounder body is pushed into mounting base and twisted to lock. Interface Options MWS424SB / MWS424DB 1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit. Options MWS424SB / MWS424DB 1. Choice of tone setting (set via DIP switches can be altered at any time). Product s MWS424SB MWS424DB Conventional low profile surface sounder Conventional weatherproof surface sounder 34

Conventional Product Range Low Current Sounder MLC624 MLC624 low current sounder Overview The MLC624 Menvier low current sounder has been designed to provide a high sound output with a low current consumption. It is ideal for applications where high sound levels need to be achieved but where available sounder circuit capacity is limited. The low current sounder is simple to install and uses a first fix back plate onto which the main body attaches with a self locking press fix assembly. Features Quick and simple to install Low current consumption High efficiency design 3 different tones Separate volume control Benefits Low current, high sound output Automatic synchronisation Self locking assembly 35

Conventional Low Current - MLC624 Dimensions Technical Specification H (mm) W (mm) D (mm) 105 105 95 Standards Specification Operating Voltage Current Consumption Sound Output Environmental Operating Temperature Humidity (Non Condensing) Physical Construction Colour Dimensions (H x W x D) Weight Ingress Protection Cable Entry Compatibility Suitable for use with MLC624 Low current sounder EN54 Pt3 12V dc to 30V dc 5mA at 24V dc 100dB(a) at 24V dc -25 C to +70 C 0 to 93% RH PC/ABS Red 105mm x 105mm x 95mm 0.25kg IP42 Rear or top/bottom Menvier conventional fire systems Standard Connection Installation Interface Options MLC624 COMMON 1st SOUND 2nd SOUND 1. First fix mounting plate is fixed to wall. 2. Cable entry is from rear, or top/bottom. 3. Connections are to main sounder body. 4. Separate alarm line in / out terminals are provided. 1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit. + + - - - - Compatible Menvier Conventional Control Panel WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable NOTE: Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal. Product s MLC624 Conventional low current sounder 36

Conventional Product Range Xenon Beacons MXB124SB and MXB124DB MXB124DB weatherproof xenon beacon MXB124SB low profile xenon beacon Low profile base Overview This range of Menvier xenon beacons is available to complement purely audible alarms for use in areas either where people may be present who have impaired hearing or areas with high ambient noise levels. Xenon beacons have a high light output to maximise the attention attracting potential of the device. MXB124SB The MXB124SB low profile xenon beacon features a high performance light source. Pre-drilled fixing and cable entry holes it is simple to install. MXB124DB The MXB124DB weatherproof xenon beacon is IP65 rated and supports side entry surface cables making it ideal for industrial applications. Lower power LED variants are also available which offer a lower current consumption but have a consequently lower light output than traditional xenon types (MLB124SB and MLB124DB LED beacons). Features MXB124SB Unobtrusive low profile design High output xenon beacon Pre drilled cable entries entry holes MXB124DB Weatherproof version (IP65) High output xenon beacon Choice of cable entry positions Benefits First fix base Compatible with range of Menvier fire detection panels Weatherproof version Weatherproof base 37

Conventional Xenon Beacons - MXB124SB and MXB124DB Dimensions Technical Specification D Dia Low profile xenon beacon Dia (mm) D (mm) Low profile xenon beacon 93 72 Weatherproof xenon beacon 93 101 D Dia Weatherproof xenon beacon MXB124SB MXB124DB Low profile xenon beacon Weatherproof xenon beacon Specification Operating Voltage 24V dc 24V dc Current Consumption 45mA at 24V dc 45mA at 24V dc Operation Continuous Continuous Flash Energy 1.45J 1.45J Flash Frequency 60 per minute 60 per minute Light Output 2.5cd 2.5cd Environmental Operating Temperature -20 C to +55 C -20 C to +55 C Humidity (Non Condensing) 0 to 93% RH 0 to 93 RH Physical Construction PC/ABS PC/ABS Colour Red Red Lens Colour Red Red Dimensions (Dia x D) 93mm x 72mm 93mm x 101mm Weight 0.2kg 0.25kg Ingress Protection IP54 IP65 Cable Entry Rear Rear/side Compatibility Suitable for use with Menvier Conventional Fire Systems Menvier Conventional Fire Systems Standard Connection MXB124SB / MXB124DB Compatible Menvier Conventional Control Panel + + - - WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable Installation MXB124SB 1. Supplied with simple to install first fix mounting base. 2. Fixing and cable entry holes are pre-drilled. 3. Cable entry is from rear. 4. Connections are to main beacon body. 5. Separate alarm line in / out terminals are provided. 6. Main body is pushed into sounder base and then twisted to lock into place. MXB124DB 1. Supplied with simple to install first fix mounting base. 2. Cable entry is from rear or side. 3. Connections are to main beacon body. 4. Separate alarm line in / out terminals are provided. 5. Main body is pushed into sounder base and then twisted to lock into place. Interface Options MXB124SB / MXB124DB 1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit. Product s MXB124SB MXB124DB MXB224SB MXB224DB Conventional low profile xenon beacon, 1 Watt Conventional weatherproof xenon beacon, 1 Watt Conventional low profile xenon beacon, 2 Watt Conventional weatherproof xenon beacon, 2 Watt 38

Conventional Product Range Xenon Sounder Beacons MCD524SB and MCD524DB MCD524DB weatherproof xenon sounder beacon MCD524SB low profile xenon sounder beacon Low profile base Weatherproof base Overview This range of Menvier xenon sounder beacons is available to complement purely audible alarms for use in areas either where people may be present who have impaired hearing or areas with high ambient noise levels. The key benefit of these devices is that an audible and a visual alarm are combined together and require only a single installation point. This greatly reduces installation time and cost and is much less obtrusive than 2 separate devices. Xenon beacons have a high light output to maximise the attention attracting potential of the device. MCD524SB The MCD524SB low profile xenon sounder beacon features a high performance light source and adjustable volume control. Due to predrilled fixing and cable entry holes it is simple to install. MCD524DB The MCD524DB weatherproof xenon sounder beacon is IP65 rated and features a high performance light source and adjustable volume control. Lower power LED variants are also available which offer a lower current consumption but have a consequently lower light output than traditional xenon types (MSB124SB and MSB124DB LED sounder beacons). Features MCD524SB Unobtrusive low profile design High output xenon beacon Pre drilled cable entries Sounder and beacon with a single installation point 32 selectable tones MCD524DB Weatherproof version (IP65) High output xenon beacon Side entry surface cables Sounder and beacon with a single installation point 32 selectable tones Benefits Combined audio / visual unit Single installation point 39

Conventional Xenon Sounder Beacons - MCD524SB and MCD524DB Dimensions Technical Specification D Dia Low profile xenon sounder beacon Dia (mm) D (mm) Low profile xenon sounder beacon 93 92 Weatherproof xenon sounder beacon 93 121 D Dia Weatherproof xenon sounder beacon MCD524SB MCD524DB Low profile xenon sounder beacon Weatherproof xenon sounder beacon Specification Operating Voltage 18V dc to 30V dc 18V dc to 30V dc Current Consumption 68mA (av) 73mA (peak) 68mA (av) 73mA (peak) Operation Continuous Continuous Flash Energy 0.7J 0.7J Flash Frequency 60 per minute 60 per minute Sound Output 101dB(a) max (+/-3) at 24V dc 101dB(a) max (+/-3) at 24V dc Number of Tones 32 32 Environmental Operating Temperature -20 C to +55 C -20 C to +55 C Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH Physical Construction PC/ABS PC/ABS Colour Red Red Lens Colour Red Red Dimensions (Dia x D) 93mm x 92mm 93mm x 121mm Weight 0.25kg 0.33kg Ingress Protection IP54 IP65 Cable Entry Rear Rear/side Compatibility Suitable for use with Menvier conventional fire systems Menvier conventional fire systems Standard Connection Installation Interface Options MCD524SB / MCD524DB Compatible Menvier Conventional Control Panel 2nd SOUND - - 1st SOUND COMMON - - + + MCD524SB 1. Supplied with simple to install first fix mounting base. 2. Fixing and cable entry holes are pre-drilled. 3. Cable entry is from rear. 4. Connections are to main beacon body. 5. Separate alarm line in / out terminals are provided. 6. Main body is pushed into sounder base and then twisted to lock into place. 7. Supply is common for sounder and beacon MCD524SB / MCD524DB 1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit. WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable NOTE: Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal. MCD524DB 1. Cable entry is from rear or side. 2. Connections are to main beacon body. 3. Separate alarm line in / out terminals are provided. 4. Main body is pushed into sounder base and then twisted to lock into place. 5. Supply is common for sounder and beacon Product s MCD524SB MCD524DB Conventional low profile xenon sounder beacon Conventional weatherproof xenon sounder beacon 40

Conventional Product Range LED Beacons MLB124SB and MLB124DB MLB124DB weatherproof LED beacon MLB124SB low profile LED beacon Low profile base Weatherproof base Overview This range of Menvier LED beacons is available to complement audible alarms for use in areas either where people may be present who have impaired hearing or areas with high ambient noise levels. LED technology offers a greatly reduced current consumption compared to xenon types making them ideal for use with fire panels with restricted sounder circuit current capacity. MLB124SB The MLB124SB low profile LED beacon is simple to install, and offers a reduced depth with pre-drilled fixing and cable entry holes, suitable for both wall or ceiling mounting. This beacon utilises 18 carefully positioned LEDs to provide a high intensity output. Both output intensity and flash frequency is selectable using internal DIP switch. MLB124DB The MLB124DB weatherproof LED beacon is IP65 rated making them ideal for industrial applications. This beacon utilises 18 carefully positioned LEDs to provide a high intensity output. Both output intensity and flash frequency is selectable using internal DIP switch. Features MLB124SB Unobtrusive low profile design Low power consumption LEDs Choice of flash frequency Choice of power settings Pre drilled cable entries MLB124DB Weatherproof version (IP65) Low power consumption LEDs Choice of flash frequency Choice of power settings Choice of cable entry positions Benefits Low power requirement Selectable flash frequency Selectable flash intensity 41

Conventional LED Beacons - MLB124SB and MLB124DB Dimensions D Dia Low profile LED beacon Dia (mm) D (mm) Low profile LED beacon 95 53 Weatherproof LED beacon 95 80 D Dia Weatherproof LED beacon Technical Specification MLB124SB MLB124DB Low profile LED beacon Weatherproof LED beacon Specification Operating Voltage 18V dc to 30V dc 18V dc to 30V dc Current Consumption 3 to 6mA at 24V dc (depending on power setting) 3 to 6mA at 24V dc (depending on power setting) Flash Frequency 30 or 60 per minute (selectable) 30 or 60 per minute (selectable) Environmental Operating Temperature -10 C to +55 C -10 C to +55 C Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH Physical Construction PC/ABS PC/ABS Colour Red Red Lens Colour Red Red Dimensions (Dia x D) 95mm x 53mm 95mm x 80mm Weight 0.1kg 0.15kg Ingress Protection IP54 IP65 Cable Entry Rear Rear/side Compatibility Suitable for use with Menvier conventional fire systems Menvier conventional fire systems Standard Connection MLB124SB / MLB124DB Compatible Menvier Conventional Control Panel + + - - WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable Installation MLB124SB 1. Supplied with simple to install first fix mounting base. 2. Fixing and cable entry holes are pre-drilled. 3. Cable entry is from rear. 4. Connections are to main beacon body. 5. Separate alarm line in / out terminals are provided. 6. Main body is pushed into base and then twisted to lock into place. MLB124DB 1. Supplied with simple to install first fix mounting base. 2. Cable entry is from rear or side. 3. Connections are to main beacon body. 4. Separate alarm line in / out terminals are provided. 5. Main body is pushed into base and then twisted to lock into place. Interface Options MLB124SB / MLB124DB 1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit. Product s MLB124SB MLB124DB Conventional low profile LED beacon Conventional weatherproof LED beacon 42

Conventional Product Range LED Sounder Beacon MSB124SB and MSB124DB MSB124DB weatherproof LED sounder beacon MSB124SB low profile LED sounder beacon low profile base Overview This range of Menvier LED sounder beacons is available to complement purely audible alarms for use in areas either where people may be present who have impaired hearing or areas with high ambient noise levels. LED technology offers a greatly reduced current consumption compared to xenon types making them ideal for use with fire panels with restricted sounder circuit current capacity. MSB124SB The MSB124SB low profile LED sounder beacon features a low current LED light source and adjustable volume control. Choice of tones can be selected via the DIP switch. With predrilled fixing and cable entry holes it is simple to install. MSB124DB The MSB124DB weatherproof LED sounder beacon is IP65 rated and features a low current LED light source and adjustable volume control. Features MSB124SB Unobtrusive low profile design Low current LED beacon Sounder and beacon with a single installation point Pre-drilled fixing and cable entry holes 32 selectable tones MSB124DB Weatherproof version (IP65) Low current LED beacon Sounder and beacon with a single installation point Choice of cable entry positions 32 selectable tones Benefits Low power requirement Adjustable sounder volume Selectable tones weatherproof base 43

Conventional LED Sounder Beacon - MSB124SB and MSB124DB Dimensions Technical Specification D Dia Low profile LED sounder beacon Dia (mm) D (mm) Low profile LED sounder beacon 93 80 Weatherproof LED sounder beacon 95 109 D Dia Weatherproof LED sounder beacon MSB124SB MSB124DB Low profile LED sounder beacon Weatherproof LED sounder beacon Standards EN54 Pt3 EN54 Pt3 Specification Operating Voltage 9V dc to 28V dc 9V dc to 28V dc Current Consumption 20mA at tone 3 20mA at tone 3 Operation Continuous Continuous Flash Frequency 60 per minute 60 per minute Number of Tones 32 32 Light Output >0.5cd >0.5cd Environmental Operating Temperature -10 C to +55 C -10 C to +55 C Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH Physical Construction PC/ABS PC/ABS Colour Red Red Lens Colour Red Red Dimensions (Dia x D) 93mm x 80mm 95mm x 109mm Weight 0.25kg 0.3kg Ingress Protection IP54 IP65 Cable Entry Rear Rear/side Compatibility Suitable for use with Menvier conventional fire systems Menvier conventional fire systems Standard Connection MSB124SB / MSB124DB Compatible Menvier Conventional Control Panel COMMON 1st SOUND 2nd SOUND + + - - - - WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of cable NOTE: Diagram shown with 1st sound connected, if 2nd sound is required connect both negative in and negative out to the second sound terminal. Installation MSB124SB 1. Supplied with simple to install first fix mounting base. 2. Fixing and cable entry holes are pre-drilled. 3. Cable entry is from rear. 4. Connections are to main beacon body. 5. Separate alarm line in / out terminals are provided. 6. Main body is pushed into sounder base and then twisted to lock into place. 7. Supply is common for sounder and beacon MSB124DB 1. Cable entry is from rear or side. 2. Connections are to main beacon body. 3. Separate alarm line in / out terminals are provided. 4. Main body is pushed into base and then twisted to lock into place. 5. Supply is common for sounder and beacon Interface Options MSB124SB / MSB124DB 1. Operates from nominal 24V dc supply and can be connected to any suitably rated conventional sounder circuit.. Product s MSB124SB MSB124DB Conventional low profile LED sounder beacon Conventional weatherproof LED sounder beacon 44

Conventional Product Range Heavy Duty Door Retainers MDR240 and MDR24L Floor mounted heavy duty door retainer Wall mounted heavy duty door retainer Door strike plate Overview This range of Menvier heavy duty magnetic door retainers are robust and simple to install, making them ideal for a wide range of applications, such as nursing homes, hospitals, schools and industrial premises. Two versions are available, the mains powered MDR240 which has a holding force of 40kg and the MDR24L 24V dc powered also with a holding force of 40kg Both versions enable doors to be held open under normal conditions but to be automatically released in the event of fire alarm activation. Their die cast aluminium construction with plastic front cover plate make them suitable for most applications. Both versions are supplied with door mounted striker plates and can be fixed directly to a suitable wall, alternatively a floor bracket can be used to allow floor mounting. An override switch is fitted as standard to enable door to be manually released as required. Features Heavy duty construction Mains and 24V dc version Manual release switch Optional floor mounting bracket available Benefits Quick and simple to install Slim profile unit 45

Conventional Heavy Duty Door Retainers - MDR240 and MDR24L Dimensions Technical Specification H W D D H (mm) W (mm) D (mm) Magnet 95 95 40 Striker Plate 65 65 48 W H MDR240 MDR24L Mains powered heavy duty door retainer 24V dc powered heavy duty door retainer Specification Operating Voltage 230V ac to 240V ac 24V dc Power Consumption 1.2VA 40mA Holding Force 40kg 40kg Environmental Operating Temperature -10 C to +55 C -10 C to +55 C Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH Physical Construction PC/ABS PC/ABS Colour White body / black plate White body / black plate Dimensions (H x W x D) Magnet: 95mm x 95mm 40mm Magnet: 95mm x 95mm 40mm Striker plate: 65mm x 65mm x 48mm Striker plate: 65mm x 65mm x 48mm Weight 1.0kg 1.0kg Ingress Protection IP40 IP40 Compatibility Suitable for use with Menvier conventional fire systems Menvier conventional fire systems Standard Connection MDR240 / MDR24L INPUT VOLTAGE TO HEAVY DUTY DOOR MAGNET WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Installation 1. Door retainer unit and striker plate should be fixed to a smooth surface. 2. A single 20mm cable entry facility is provided. 3. Door retainer can be rotated to provide cable entry at either top, bottom or side as required. 4. Fixings should be able to support at least double the holding force of the magnet. System Functionality 1. Designed to operate only with self closing doors. 2. Door retainer is fitted to wall or floor using floor bracket. 3. Striker plate is fitted to door. 4. Door retainer is fed with a constant supply via an external control device. 5. Supply energises an electromagnet, which holds the striker plate securely against the magnet. 6. If supply to magnet is interrupted, magnet deenergises. 7. Door closes under control of its own self closing device. Product s MDR240 MDR24L ZMDRFBB Conventional mains powered heavy duty magnetic door retainer Conventional 24V dc heavy duty magnetic door retainer Floor mounting bracket for heavy duty door retainer 46

Intelligent Addressable Product Range Intelligent Addressable Contents Page 49 Control Panels DF6100 Page 77 Callpoints MBG813 and MBG817 Page 57 Control Panels DF6000 Page 79 Wall Sounders MAS850LPS and MAS850LPSWP Page 61 Passive Repeater Panel DF6000PR Page 81 Wall Sounder Beacons MASB860 and MASB860WP Page 63 Touch Screen Repeater Panel DTPR6000 Page 83 Loop Connected LED Beacon MAB870 Page 65 Sensors MAP820, MAOH850 and MAH830 Page 85 Interfaces Page 67 Standard Base MAB800 Page 97 Micro Interfaces Page 69 Sounder Base MAS850 Page 107 Ancillaries and Test Equipment Page 71 Sounder Beacon Base MASB870 Page 73 Loop Connected Remote Indicator MRIAD Page 75 Reflective Beam Detectors MAB50R and MAB100R 47

Intelligent Addressable Product Range Intelligent Addressable System Architecture Standard conventional systems utilise simple two state detectors, which simply provide a switch type signal to the conventional control panel. To enable the source of the alarm to be identified, each zone must be wired using a separate circuit, furthermore in the event of a fire alarm being triggered, the panel can only identify which zone contains the triggered device, it is then necessary to manually search the affected zone to discover the actual cause of the alarm. Intelligent addressable systems overcome these limitations, each fire detecting sensor or callpoint is electronically coded with a unique identification or 'address' which is programmed into the device during installation. The control panel is then able to conduct two way communication with any of the addressable devices connected to the system by using the unique address number to define which device it wishes to communicate with. This operates in a similar manner to that of a telephone number enabling communication between specific telephones. Under normal conditions the control panel continuously interrogates each device in sequence using a low power digitally pulsed signal, and analyses the reply to determine the status of the sensor or callpoint. In this manner, the panel can ascertain whether each device is functioning correctly and also discover the amount of smoke or heat that the device is currently sensing. This technology allows the panel to make intelligent decisions as to the appropriate action to take based on the information it receives from the individual sensors. If whilst continually interrogating the smoke and heat sensors, the panel determines that the data gathered from a specific device is appropriate to instigate either a fire, fault or pre alarm condition, it uses the unique identifying number or address to determine which device is involved. Consequently the panel can pinpoint and identify precisely which device has triggered the fire, fault or pre alarm condition. This level of sophistication removes the need for each zone of the building to be wired as a separate circuit. For this reason intelligent addressable system components are typically connected to the panel using a small number of large loops thus greatly simplifying the installation of the system and reducing the installation cost. Detectors instead of being simple two state devices now function as sensors continually communicating with the control panel and providing information regarding the temperature or concentration of smoke in their local environment. 14 13 Zone 1 15 16 Zone 2 1 2 3 4 This has many advantages, for example very slow build up of apparent smoke density seen by a sensor can cause a warning or pre alarm condition to be triggered by the alarm panel prior to the situation becoming serious enough to warrant a full alarm. 12 Mains Supply 5 A typical practical benefit of this technology is the situation whereby airborne dust particles enter smoke detectors and mimic the appearance of smoke, over time the concentration of dust can increase to a point where it can cause the detector to falsely trigger an alarm condition. With an intelligent addressable system, a pre alarm condition will normally be triggered rather than a full alarm giving the building operator the opportunity to clean or replace the sensor rather than suffer the disruption of an unwanted false alarm. 11 10 Zone 3 9 8 Zone 4 7 6 48

Intelligent Addressable Product Range DF6100 Control Panels DF6100 control panel Overview The Menvier DF6100 range is available as a high specification 1 or 2 loop intelligent addressable control panel, offering sophisticated functionality with simple end user operation. The simplicity of operation, powerful cause and effect programming capability, and competitive pricing make the system suitable for a wide range of small to medium sized projects. DF6100 uses soft addressing to minimise installation time and remove the potential for error associated with manual addressing. These panels can operate as a stand alone panel or as part of a network with the Menvier range of DF6000 panels or other DF6100 panels, (additional network card required). The DF6100 panel has an integral power supply and is supplied with batteries as standard. An extensive range of compatible intelligent addressable system ancillaries are available to work with the DF6100 all of which incorporate an integral short circuit isolator to provide maximum protection against short circuits on the loop. Features Large versatile touch screen display Competitive single or two loop system Spur tolerant soft addressing Large selection of compatible ancillaries Full network capability Integral battery and power supply 200 address capacity per loop Approved to EN54 Pt13 and EN54 Pt2 and Pt4 Benefits Simple end user interface Range of compatible ancillaries System protocol allows fast and accurate configuration 49

Intelligent Addressable Control Panel - DF6100 and DF61002 Technical Specification DF6100 DF61002 1 loop control panel 2 loop control panel Standards EN54 Pt2 1997 & 2006: A1, EN54 Pt4 1997 & 2002: A1 EN54 Pt2 1997 & 2006: A1, EN54 Pt4 1997 & 2002: A1 EN54 Pt13, EN50130-4 EN54 Pt13, EN50130-4 Specification Number of Loops 1 2 Addresses per Loop 200 200 Number of Conventional 2 monitored for open and short circuit 2 monitored for open and short circuit Sounder Circuits (max 1.5A combined) (max 1.5A combined) Auxiliary Fire Routing Equipment Output (Monitored) 24V dc 30mA (max) 24V dc 30mA (max) Auxiliary Fire Protection Equipment Output (Monitored) 24V dc 30mA (max) 24V dc 30mA (max) Auxiliary Fault Routing Equipment Output (Monitored) 12V dc 30mA (max) 12V dc 30mA (max) System Operating Voltage 24V dc (nom) 24V dc (nom) Mains Input Supply 230V ac +10% / -15% 230V ac +10% / -15% Class Change Facility Terminals for connection of external contacts, Terminals for connection of external contacts, can also be instigated via input interface can also be instigated via input interface Auxiliary Relay 1 set of changeover contacts 1 set of changeover contacts operate in event of fire condition operate in event of fire condition Output Ports RS485, RS232 for connection of repeaters etc RS485, RS232 for connection of repeaters etc Standby Duration Dependant on loop loading and battery configuration Dependant on loop loading and battery configuration Battery 2 x 7Ah 2 x 7Ah Environmental Operating Temperature -5 C to +40 C -5 C to +40 C Humidity (Non Condensing) 0 to 75% RH 0 to 75% RH Physical Construction Steel back box Steel back box Dimensions (H x W x D) 375mm x 375mm x 95mm 375mm x 375mm x 95mm Weight 8kg 8kg Ingress Protection IP30 IP30 Cable entries Top: cable knockouts (20mm) Back: cable aperture Top: cable knockouts (20mm) Back: cable aperture System Networking Fully Networkable up to 127 panels Fully Networkable up to 127 panels (requires additional network card, per panel) (requires additional network card, per panel) Dimensions D W H (mm) W (mm) D (mm) 375 375 95 H Product s DF6100 DF61002 DF6100VDS DF61002VDS NC DF61NETKIT DF6000PR DTPR6000 MFALOG Intelligent addressable 1 loop control panel Intelligent addressable 2 loop control panel Intelligent addressable 1 loop control panel (VDS Approved) Intelligent addressable 2 loop control panel (VDS Approved) Add to end of product code if network card required Network kit (retro fit) Passive repeater panel Touch screen repeater panel Fire alarm system log book 50

Intelligent Addressable Control Panel - DF6100 and DF61002 Installation 1. Panel is designed for surface or recessed mounting (without the need for an additional bezel). 2. Cable entry is by means of top entry knockouts in the metal back box, along with a substantial rear entry cutout. 3. Panels are wall mounted via keyhole/slot mounting holes on back of housing. 4. Key operated hinged lockable door provides access to all internal wiring. 5. Cable entry can either be top or rear. 6. Mains input protection is provided by integral fuse 7. All external wiring should be in accordance with relevant section of latest edition of BS5839-Pt1. 8. Comprehensive installation and operation manual provided with each system. System Functionality 1. Panel has 3 modes of operation, normal mode, user maintenance mode and engineer mode. 2. User maintenance and engineer modes can only be accessed by entering relevant pass codes 3. Maintenance mode allows access to system test functions, enable and disable menus, view analogue level menus and functions such as evacuate, silence alarms and reset. 4. Engineer mode allows alteration of system configuration and programming of site specific data such as device text and sounder programming. 5. Engineer mode also allows adding and removal of devices and alteration of existing text. 6. DF6100 is designed to ensure simplicity of future expansion. If an additional device is added after the system has been programmed, the DF6100 will allocate the next available address, it will not alter any of the existing address number allocation thus enabling simple updating of as fitted drawings etc. Similarly if a device is removed, the relevant address is saved as a spare address for future use, the addresses of the remaining devices are not affected. 7. All devices are soft addressed during commissioning however once allocated, addresses are locked until manually altered thus enabling simple system additions and deletions without affecting other addresses. 8. In event of an external short circuit occurring, short circuit isolators on output of the devices nearest to each side of the short circuit open thus isolating the short circuit. The panel then drives communication from both ends of the loop thus maintaining full communication with all devices. User Interface 1. The main element of the user interface with DF6100 is a large (120mm x 90mm visible area) touch screen display, which provides comprehensive user information and also acts as a multifunctional keypad. With other more basic systems, the user is limited to a small number of dedicated pushbuttons and consequently system interaction is restricted and complicated. 2. Comprehensive context sensitive help information is provided throughout the menus to assist unfamiliar users with system operation. 3. The DF6100 touch screen display automatically reconfigures to suit the selected function, for example, if the change device text menu option is selected, the touch screen is automatically formatted as a full QWERTY keyboard to enable fast and simple text entry. 4. As well as a large format LCD display providing full system status information, the panel incorporates 16 traditional zone indication LED's to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the system. In addition there are a number of system status LED's designed to give clear status information to non technical users 5. Audible buzzer with mute facility. 6. Hinged lockable door provides access to all internal wiring and components. Detection Capacity 1. Up to 200 addresses per loop which can be a mixture of callpoints, detectors, interfaces or loop sounders. 2. DF6100 panels can be networked with all Cooper intelligent addressable and wireless panels. Alarm Capacity 1. Up to 80 loop powered sounder beacons per loop. 2. Up to 20 I/O units per loop. 3. 3 stages of cause and effect programming per output device. 4. 0.8A of panel connected conventional sounders. 5. Additional conventional sounders can be connected via loop mounted MPU424 units. Interface Options Day night mode override via external switched signal. (Can be a timer). Multiple Programmable remote inputs can be set: Override of day night mode setting - Photo-thermal detectors go to thermal only. - Rate of rise detectors go to fixed high temperature mode. - High temperature heat detectors go to rate of rise mode. T1 and T2 timer. HMO facility. Comprehensive cause and effect programming. Test per zone or address. Alarm verification per zone. Coincidence detection. Disablement of pre assigned group of addresses. Class change. Non latching zone input. Evacuate. 2 Conventional sounder circuits provided. Zone monitor units can be used to connect zones of suitable conventional detectors or loop powered beam detectors. Sounder circuit controllers can be used to provide additional conventional sounder circuits without wiring back to main panel. Mains rated input/output unit available. 3 way 24V rated input/output unit available. Spur isolator available to allow spurs of intelligent addressable devices. Compact input and output modules available Shop unit interface allows the connection of a conventional detection zone along with a power supply and 2 conventional sounder circuits, ideal for linking small self contained units onto a main addressable panel. 51

Intelligent Addressable Control Panel - DF6100 and DF61002 System Networking DF6000 and DF6100 systems can both be networked together. Up to 126 DF6000 panels, DF6100 panels and low cost repeaters can be networked together to operate as a single networked system. Typical System Architecture 4 independently controlled conventional sounder circuits To achieve this each panel must be fitted with a network card (optional extra). When operating as a networked system all fire and fault event information can be displayed at every panel. spur of analogue devices zone of compatible conventional devices Panels can be configured by service engineers to control whether fire and fault information from each panel is transmitted around the network or not. Mains Supply Silencing and resetting of alarms can also be carried out from any panel on a networked system. Networked panels are connected using a loop topology as illustrated. sounder controller unit loop connected repeater panel spur isolator unit zone monitor unit DF6100 Mains Supply 3 independent volt free output contacts 3 way input/output unit 3 separate inputs to accept fire or non fire inputs shop monitor unit Mains Supply Mains Supply Mains Supply Mains Supply mains rated output relay contact DF6000, DF6100 and DTPR6000 input/output unit fire or non fire input control panel zone of compatible conventional devices 2 circuits of conventional sounders Mains Supply Mains Supply Mains Supply Mains Supply Mains Supply 2 circuits of conventional sounders network connected repeater panel 52

} Intelligent Addressable Control Panel - DF6100 and DF61002 Standard Panel Connections MENVIER CONVENTIONAL SOUNDERS (IF REQUIRIED) SOUNDER CIRCUIT 1 - + 6K8 EOL RESISTOR* SOUNDER CIRCUIT 2 - + 6K8 EOL RESISTOR* AUX RELAY 1 NO C NC NO C NC AUX RELAY 2 VOLT FREE CHANGE OVER CONTACT VOLT FREE CHANGE OVER CONTACT + - FAULT RELAY FAULT RELAY A NETWORK 1 B X Y NETWORK 1 E A NETWORK 2 B X Y NETWORK 2 E + 24V OUT + - 24V dc OUTPUT E E S+ LOOP 1 F+ LOOP 1 CONNECTIONS F- S- E E S+ LOOP 2 F+ LOOP 2 CONNECTIONS (IF DF61002) F- S- FINISH LOOP TERMINALS START LOOP TERMINALS * required to be fitted to terminal if circuits not used 53

Intelligent Addressable Product Range 54

Intelligent Addressable Product Range DF6000 Range Control Panels DF6000 control panel with printer DF6000 graphite control panel with protective cover and printer rack mounted panels Overview The Menvier DF6000 is a high specification intelligent addressable control panel available in various loop configurations. It combines sophisticated functionality with simple operation and a very aesthetically pleasing design. The large capacity, ability to support complex cause and effect programming and wide range of user controllable functions make the system suitable for a diverse range of projects from sheltered housing to large office developments and industrial applications. DF6000 uses soft addressing to minimise installation time and remove the potential for error associated with manual addressing. The DF6000 can operate as a stand alone panel or as part of a networked system. They have powerful programming options that allow configurable control over whether messages from specific panels are transmitted around the network or remain local. The DF6000 panel has an integral power supply and the batteries are supplied with the panel as standard. An extensive range of compatible intelligent addressable systems ancillaries are available to work with the DF6000 all of which incorporate an integral short circuit isolator to provide maximum protection against short circuits on the external loop. Features 1, 2 and 4 loop versions Spur tolerant soft addressing Full network capability Optional integral printer Integral battery and power supply 200 addresses per loop Charger with temperature compensation built in Checks battery capacity Benefits Simple end user interface Range of compatible ancillaries Easy to design system System Integrity 55

Intelligent Addressable Control Panels - DF6000 Range Technical Specification DF60001 DF60002 DF60004 1 loop control panel 2 loop control panel 4 loop control panel Standards EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996, EN50130-4 EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996, EN50130-4 EN54 Pt2 & Pt4 1998, EN50130 Pt4 1996, EN50130-4 Specification Number of Loops 1 2 4 Addresses per Loop 200 200 200 Number of Conventional Sounder Circuits 4 monitored for open and short circuit 4 monitored for open and short circuit 4 monitored for open and short circuit Auxiliary Fire Routing Equipment Output (Monitored) 24V 30mA (max) 24V 30mA (max) 24V 30mA (max) Auxiliary Fire Protection Equipment Output (Monitored) 24V 30mA (max) 24V 30mA (max) 24V 30mA (max) Auxiliary Fault Routing Equipment Output (Monitored) 12V 30mA (max) 12V 30mA (max) 12V 30mA (max) System Operating Voltage 24V dc (nom) 24V dc (nom) 24V dc (nom) Mains Input Supply 230V ac +10% / -15% 230V ac +10% / -15% 230V ac +10% / -15% Class Change Facility Terminals for connection of external contacts, Terminals for connection of external contacts, Terminals for connection of external contacts, can also be instigated via input interface can also be instigated via input interface can also be instigated via input interface Auxiliary Relay 1 set of changeover contacts operate in event of fire condition 1 set of changeover contacts operate in event of fire condition 1 set of changeover contacts operate in event of fire condition Output Ports RS485, RS232 for connection of repeaters etc RS485, RS232 for connection of repeaters etc RS485, RS232 for connection of repeaters etc Standby Duration Dependant on loop loading and battery configuration Dependant on loop loading and battery configuration Dependant on loop loading and battery configuration Battery 2 x 12Ah (standard versions) 2 x 12Ah (standard versions) 4 x 12Ah (EB versions) 2 x 12Ah (standard versions) 4 x 12Ah (EB versions) Environmental Operating Temperature -5 C to +40 C -5 C to +40 C -5 C to +40 C Humidity (Non Condensing) 0 to 75% RH 0 to 75% RH 0 to 75% RH Physical Construction Back box - mild steel, front door - PC/ABS Back box - mild steel, front door - PC/ABS Back box - mild steel, front door - PC/ABS Dimensions (H x W x D) Standard versions: 395mm x 495mm x 180mm Standard versions: 395mm x 495mm x 180mm Standard versions: 395mm x 495mm x 180mm EB versions: 395mm x 495mm x 280mm EB versions: 395mm x 495mm x 280mm Weight 18kg 18kg 18kg Ingress Protection IP30 IP30 IP30 Cable entries Top: 31 cable knockouts (20mm) Back: 12 cable knockouts (20mm) Top: 31 cable knockouts (20mm) Back: 12 cable knockouts (20mm) Top: 31 cable knockouts (20mm) Back: 12 cable knockouts (20mm) System Networking Fully networkable up to 126 panels Fully networkable up to 126 panels Fully networkable up to 126 panels (requires additional network card - 1 per panel) (requires additional network card - 1 per panel) (requires additional network card - 1 per panel) Dimensions Product s H D2 D1 H (mm) W (mm) D1 (mm) D2 (mm) Standard 395 495 55 125 EB 395 495 55 225 Note: W If surface mounting add D1 and D2 to obtain depth dimension. * For further information on the 39UERACK 19" rack and associated panels contact Cooper Fire technical support: 01302 303350 DF60001 DF60002 DF60004 DF60001P DF60002P DF60004P DF60001G DF60002G DF60004G DF60001PG DF60002PG DF60004PG DF60002EB DF60004EB DF60002PEB DF60004PEB DF60002GEB DF60004GEB DF60002PGEB DF60004PGEB NC DF6000NETKIT DF6000COV DF6000PR DFPR6000 39UECRACK MFALOG 1 loop control panel 2 loop control panel 4 loop control panel 1 loop control panel, integral printer 2 loop control panel, integral printer 4 loop control panel, integral printer 1 loop control panel, graphite finish 2 loop control panel, graphite finish 4 loop control panel, graphite finish 1 loop control panel, integral printer, graphite finish 2 loop control panel, integral printer, graphite finish 4 loop control panel, integral printer, graphite finish 2 loop control panel, extended battery 4 loop control panel, extended battery 2 loop control panel, integral printer, extended battery 4 loop control panel, integral printer, extended battery 2 loop control panel, graphite finish, extended battery 4 loop control panel, graphite finish, extended battery 2 loop control panel, graphite finish, integral printer, extended battery 4 loop control panel, graphite finish, integral printer, extended battery Add to end of product code if network card required Network kit (for retor fit) Hinged protective cover kit Passive repeater panel Touch screen repeater panel 19" rack, 39 units high* Fire alarm system log book 56

Intelligent Addressable Control Panels - DF6000 Range Installation 1. Standard panel is designed for surface or recessed mounting (without the need for an additional bezel). 2. Cable entry is by means of top entry knockouts in the metal back box, along with a substantial rear entry cutout. 3. Panels are wall mounted via keyhole/slot mounting holes on back of housing. 4. Front cover retained by screws, accessed after opening the printer bay door. 5. Flush mounting requires suitable aperture and fixings. 6. Mains input protection is provided by a polyswitch. 7. All external wiring should be in accordance with relevant section of latest edition of BS5839-Pt1. 8. Comprehensive installation and operation manual provided with each system. 9. Maximum length of network cable loop is 1500 metres, beyond this distance or where cables pass between buildings, boosters will be required. System Functionality 1. Panel has 3 modes of operation, normal mode, user maintenance mode and engineer mode. 2. User maintenance and engineer modes can only be accessed by entering relevant pass codes 3. Maintenance mode allows access to system test functions, enable and disable menus, view analogue level menus and functions such as evacuate, silence alarms and reset. 4. Engineer mode allows alteration of system configuration and programming of site specific data such as device text and sounder programming. 5. Engineer mode also allows adding and removal of devices and alteration of existing text. 6. DF6000 is designed to ensure simplicity of future expansion. If an additional device is added after the system has been programmed, the DF6000 will allocate the next available address, it will not alter any of the existing address number allocation thus enabling simple updating of as fitted drawings etc. Similarly if a device is removed, the relevant address is saved as a spare address for future use, the addresses of the remaining devices are not affected. 7. All devices are soft addressed during commissioning however once allocated, addresses are locked until manually altered thus enabling simple system additions and deletions without affecting other addresses. 8. In event of an external short circuit occurring, short circuit isolators on output of devices nearest to each side of the short circuit open thus isolating the short circuit. The panel then drives communication from both ends of the loop thus maintaining full communication with all devices. User Interface 1. The main element of the user interface with DF6000 is a large (120mm x 90mm visible area) touch screen display, which provides comprehensive user information and also acts as a multifunctional keypad. With other more basic systems, the user is limited to a small number of dedicated pushbuttons and consequently system interaction is restricted and complicated. 2. Comprehensive context sensitive help information is provided throughout the menus to assist unfamiliar users with system operation. 3. The DF6000 touch screen display automatically reconfigures to suit the selected function, for example, if the change device text menu option is selected, the touch screen is automatically formatted as a full QWERTY keyboard to enable fast and simple text entry. 4. As well as a large format LCD display providing full system status information, the panel incorporates 96 traditional zone indication LED's to provide clear information about the status and spread of a fire even to a user who is completely unfamiliar with the operation of the system. In addition there are a number of system status LED's designed to give clear status information to non technical users 5. Access to printer (when fitted) is via separate locked access door. Paper can be changed by non skilled personnel without exposure to any live components. 6. The printer can either be set to print on demand or to automatically print all system events as they occur. 7. The hinged front door provides simple access to all internal components and wiring. 8. The panel door cannot be opened without the use of a special key (supplied with panel). 9. For applications requiring a high level of resilience, a clear hinged lockable front cover is available that still allows full system visibility but prevents unauthorized access to the touch screen. Detection Capacity 1. Up to 200 addresses per loop which can be a mixture of callpoints, detectors, interfaces loop sounders or repeaters. 2. To comply with EN54 requirements no more than 512 addresses should be connected to a single panel. 3. Panels are available with up to 4 detection loops, up to 126 panels can be networked together giving a total system capacity of over 32,000 devices. Alarm Capacity 1. Up to 60 loop powered sounder beacons per loop. 2. Up to 20 I/O units per loop. 3. 3 stages of cause and effect programming per output device. 4. Depending on loop load up to 3A of panel connected conventional sounders. 5. Additional conventional sounders can be connected via loop connected MPU424 units. Interface Options Monitored output to fire routing equipment. Monitored output to fire protection equipment. Monitored output to fault monitoring equipment. Multiple Programmable remote inputs can be set: Override of day night mode setting - Photo-thermal detectors go to thermal only. - Rate of rise detectors go to fixed high temperature mode. - High temperature heat detectors go to rate of rise mode. Disablement of pre assigned group of addresses. Class change. Non latching zone input. Evacuate. 4 Conventional sounder circuits provided. Zone monitor units can be used to connect zones of suitable conventional detectors and callpoints. Sounder circuit controllers can be used to provide additional conventional sounder circuits without wiring back to main panel. Mains rated input/output unit available. 3 way 24V rated input/output unit available. Spur isolator available to allow spurs of intelligent addressable devices. Compact input and output modules available Shop unit interface allows the connection of a conventional detection zone along with a power supply and 2 conventional sounder circuits, ideal for linking small self contained units onto a main addressable panel. 57

Intelligent Addressable Control Panels - DF6000 Range System Networking Typical System Architecture DF6000 and DF6100 systems can both be networked together. Up to 126 DF6000 panels, DF6100 panels and low cost repeaters can be networked together to operate as a single networked system. 4 independently controlled conventional sounder circuits To achieve this each panel must be fitted with a network card (optional extra). When operating as a networked system all fire and fault event information can be displayed at every panel. loops 2-4 if fitted spur of analogue devices zone of compatible conventional devices Panels can be configured by service engineers to control whether fire and fault information from each panel is transmitted around the network or not. Mains Supply Silencing and resetting of alarms can also be carried out from any panel on a networked system. Networked panels are connected using a loop topology as illustrated. sounder controller unit loop connected repeater panel spur isolator unit zone monitor unit Networking DF6000 3 independent volt free output contacts 3 way input/output unit 3 separate inputs to accept fire or non fire inputs shop monitor unit Mains Supply Mains Supply Mains Supply Mains Supply mains rated output relay contact DF6000, DF6100 and DTPR6000 input/output unit fire or non fire input control panel zone of compatible conventional devices 2 circuits of conventional sounders Mains Supply Mains Supply Mains Supply Mains Supply 2 circuits of conventional sounders network connected repeater panel 58

Intelligent Addressable Control Panels - DF6000 Range Standard Panel Connections +5.5V SUPPLY FOR PRINTER (IF FITTED) LOOP CIRCUITS CLASS CHANGE AUX RELAY FAULT RELAY +24V O/P FIRE R/E FIRE P/E LOOP 1 LOOP 2 LOOP 3 LOOP 4 SOUNDER CIRCUIT 1 SOUNDER CIRCUIT 2 MODEM/PC Rs232 MIMC REPEATER NO C NC - + - + - + - + S+ S- F- F+ S+ S- F- F+ S+ S- F- F+ S+ S- F- F+ - + + 1- + 2- + 1- + 2- Tx Rx CTS RTS 0V Tx+ Tx- } } VOLT FREE CHANGE OVER CONTACT 6K8 EOL RESISTOR* 6K8 EOL RESISTOR* 6K8 EOL RESISTOR* START LOOP 1 FINISH LOOP 1 START LOOP 2 FINISH LOOP 2 START LOOP 3 FINISH LOOP 3 START LOOP 4 FINISH LOOP 4 CLASS CHANGE INPUT IF REQUIRED 6K8 EOL RESISTOR* MENVIER CONVENTIONAL SOUNDERS (IF REQUIRED) * required to be fitted to terminal if circuits not used 59

Intelligent Addressable Product Range 60

Intelligent Addressable Product Range Passive Repeater Panel DF6000PR Simple user interface DF6000PR passive repeater panel 2 x 40 backlit LCD display and 6 supervisory LEDs Overview The DF6000PR is a cost effective passive repeater panel which can be programmed via its informative display to be either fully passive (display only) or semi passive (restricted system control). When loop connected the repeater panel will display the system information text of the connected control panel and will provide a fire indication, with panel number, of any connected network control panel that has fire activation. The DF6000PR repeater panel only requires programming with local text information. In addition to the repeater panels main menu driven 2 x 40 backlit LCD display, which provides system status information, it also has 6 supervisory LEDs (Power On, Alarm, Trouble, Supervisory, Test In Progress, and Scroll). Features Up to 20 repeaters can be connected to the loop 2 x 40 backlit LCD display and 6 supervisory LEDs Compact size Can be surface or semirecessed mounted Benefits Menu driven easy to operate Simple connection to panel loop circuit reduces wiring and installation time Distance run up to 2km from main panel without additional cable and equipment, saving cost 61

MUTE SCROLL BUZZER Intelligent Addressable Passive Repeater Panel - DF6000PR Dimensions Technical Specification H D2 D1 W 1 2 3 4 5 H (mm) W (mm) D1 (mm) D2 (mm) 270 332 45 47 CF30000PR Passive repeater panel Standards EN54 Pt4 Specification Mains Input Voltage 230V ac +10% / -15% Operating Voltage 24V dc System Indicators Power on, fire, fault, test, disable and scroll System Controls Silence alarms, evacuate and reset Input Ports RS232 (for connection of programmer) Battery 1 x 12V 3.2Ah Standby Duration 24 hours Environmental Operating Temperature 0 C to +25 C Humidity (Non Condensing) 0 to 75% RH Physical Construction PC/ABS Colour Light Grey Dimensions (H x W x D) 332mm x 270mm x 92mm Weight 3.6kg Ingress Protection IP30 Compatibility Suitable for use with Menvier intelligent addressable fire systems Loop Connected Note: Mains Supply Mains Supply Network Link In this configuration the repeater would give text information for the panel that is on the loop, but only address number for the other panel on the network. Network Connected Installation 1. Wall mounted by means of 4 fixing screws. 2. Cable entry at top or back. 3. 12 top entry gland holes with push out blanking plugs. 4. 4 separate rear access cable entry facilities. 5. Local mains supply required. System Functionality 1. Panel operates in either normal, supervisor or engineer mode. 2. Supervisor and engineer modes are accessed via 4 digit pass codes. 3. Supervisor mode allows silence, evacuate and reset commands to be sent to host panel (loop connected) or to network (network connected). 4. Engineer mode enables password to be changed if required and allows access to text download menu 5. When connected to network, all text is transmitted via network, changes to other network panels update automatically. Standard Connection 6. When connected to a detector loop, text for host is downloaded to repeater and updated manually as required. 7. Zonal fire and fault indication is by means of 2 x 40 character LCD display. Device Overview 1. Panel can be connected to either the detection loop of a single panel or to a network as part of a networked system. 2. Supplied with integral power supply and standby battery. SCREEN Rs485 MIMIC Tx + Tx - TEXT DOWNLOAD SCREEN LOOP OUT - + SCREEN LOOP IN - + Mains Supply Network Link Product s DF6000PR DF6000PRNC Intelligent addressable passive repeater panel, loop connected Intelligent addressable passive repeater panel, network connected 62

Intelligent Addressable Product Range Touch Screen Repeater Panel DTPR6000 DTPR6000 touch screen repeater panel Overview The DTPR6000 touch screen repeater panel provides sophisticated touch screen functionality yet achieves a simple end-user interface operation within a compact panel design. The DTPR6000 is designed to work with all Menvier intelligent addressable fire alarm control panels as well as other network repeaters. The Menvier touch-screen repeater panel is easy to install and commission. All text is transmitted via the network and is automatically updated. Features Plug and play. All information is downloaded through the network Touch-screen display Integrated network capability allows networking with the latest Menvier range of intelligent addressable fire alarm control panels Multi language capability Up to 126 repeaters can be connected to the network Programmable as an active or passive repeater Benefits Plug and play requires no programming User friendly touch screen display System integrity, fire alarm system continues to operate even if there is a short circuit or open joint on cable Multi language capability 63

Touch Screen Repeater Panel - DTPR6000 Dimensions Technical Specification H D W DTPR6000 Touch screen repeater panel Standards EN54 Pt4 Specification Mains Input Voltage 230V ac +10% / -15% Operating Voltage 24V dc H (mm) W (mm) D1 (mm) 375 537 50 System Indicators System Controls Input Ports Battery Standby Duration Environmental Operating Temperature Humidity (Non Condensing) Physical Construction Colour Dimensions (H x W x D) Weight Ingress Protection Compatibility Suitable for use with Power on, fire, fault, test, disable and scroll Silence alarms, evacuate and reset RS232 (for connection of programmer) 2 x 12V 3.2Ah 24 hours -5 C to +40 C 0 to 75% RH PC/ABS Graphite 375mm x 357mm x 50mm 8kg IP30 Menvier intelligent addressable fire systems Network Connected Mains Supply Network Link Installation Wall mounted by means of 4 fixing screws. Cable entry at top or back. 11 top entry gland holes. Separate rear access cable entry facility. Local mains supply required. Must be network connected. System Functionality Panel operates in either normal, supervisor or engineer mode. Supervisor and engineer modes are accessed via 4 digit pass codes. Supervisor mode allows full system operation. Engineer mode enables password to be changed if required and allows access to text download menu When connected to network, all text is transmitted via network, changes to other network panels update automatically. Standard Connection Device Overview Panel is connected to the network as part of a networked system. Supplied with integral power supply and standby battery. Touch screen user interface. +24V dc IN + - +24V dc OUT + - NETWORK 1 A B X Y E NETWORK 2 A B X Y E FAULT RELAY NO C NC NO AUX RELAY C NC PROGRAMMABLE INPUT E TO PANEL EARTH Product s DTPR6000 Intelligent addressable touch screen repeater panel 64

Intelligent Addressable Product Range Sensors MAP820, MAOH850 and MAH830 MAP820 optical sensor MAOH850 photo-thermal sensor Optical / photo-thermal / heat detectors MAH830 heat sensor Overview The Menvier range of intelligent addressable sensors have been specifically designed to operate with Menvier intelligent addressable control panels. All sensors are third party approved to the relevant section of EN54 (part 7 for smoke detectors & part 5 for heat detectors). Features Soft addressed Integral short circuit isolator Wide range of sensor types 360 visibility LED Benefits Single multi-mode heat sensor 65

Intelligent Addressable Sensors - MAP820, MAOH850 and MAH830 Technical Specification MAP820 MAOH850 MAH830 Optical smoke sensor Photo-thermal sensor Multi-mode heat sensor Standards EN54 Pt7 2000 + A1:2002 EN54 P5 & P7 2000 + A1:2002 EN54 Pt5 2000 + A1:2002 Operating voltage 18V dc to 30V dc 18V dc to 30V dc 18V dc to 30V dc Standby Current 220µA (max) 220µA (max) 220µA (max) Alarm Current 5mA (max) 5mA (max) 5mA (max) Addressing Mode Auto address Auto address Auto address Specification Mounting Position Ceiling in open areas Ceiling in open areas Ceiling in open areas Mounting Options Surface mount with MAB800 base Surface mount with MAB800 base Surface mount with MAB800 base Area Coverage 100m² (subject to local standard) 100m² (subject to local standard) 50m² (subject to local standard) System Wiring Min. 1.5mm, 2 core loop or spur Min. 1.5mm, 2 core loop or spur Min. 1.5mm, 2 core loop or spur Heat Class Rate of Rise N/A A1S A1R Fixed Heat 77ºC N/A N/A BS Fixed Heat 90ºC N/A N/A CS Alarm Temperature (static) AIR N/A 60ºC 60ºC BS N/A N/A 77ºC CS N/A N/A 90ºC Indication 360 visibility light pipe 360 visibility light pipe 360 visibility light pipe Environmental Operating Temperature -20 C to +60 C -20 C to +50 C -20 C to +60 C Humidity (non condensing) 0 to 95% RH 0 to 95% RH 0 to 95% RH Physical Construction PC/ABS PC/ABS PC/ABS Colour White White White Dimensions Excl Base (Dia x D) 101mm x 33mm 101mm x 43mm 101mm x 43mm Dimensions Incl Base (Dia x D) 104mm x 45mm 104mm x 55mm 104mm x 55mm Weight (without base) 76g 76g 76g Compatibility Suitable for use with Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems Dimensions Installation User Interface D Dia 1. Sensors are fixed and wired via common mounting base. 2. Cable entry into base can be rear or side. 3. A locking facility is provided which can be activated if required to prevent unauthorised sensor removal without the use of a special tool. Note: For wiring information please see MAB800 base 1. LED indicates detector status, can be set to flash to confirm communication with control panel, illuminates continuously under fire conditions. 2. All wiring connections are via a common mounting base (ordered separately). Dia (mm) D (mm) D (mm) (excl base) (incl base) Optical 101 33 45 Photo-thermal 101 43 55 Multi-mode heat 101 43 55 Product s MAP820 Intelligent addressable optical smoke sensor MAOH850 Intelligent addressable photo/thermal sensor MAH830 Intelligent addressable multi-mode heat sensor MAB800 Intelligent addressable common base MAB800*10 Intelligent addressable common base (pack of 10) MDP201 Duct Probe 66

Intelligent Addressable Product Range Standard Base MAB800 Suitable sensors for use with the MAB800 standard base MAP820 optical sensor MAB800 standard base MAOH850 photo-thermal sensor MAH830 multi-mode heat sensor Overview The MAB800 Menvier intelligent addressable standard base has been specifically designed to be compatible with Menvier intelligent addressable sensors. This standard base has been designed for flexibility, simplicity and speed of installation. It incorporates a purpose designed shorting link to ensure wiring continuity if a sensor is removed. The standard base incorporates a retaining clip to provide positive feedback when sensor is correctly fitted and a retaining clip that can be replaced with locking device (supplied with base) to prevent unauthorised sensor removal. Features Sensor shorting link Separate loop in and loop out terminals Stand off fixing feature Accepts side entry cables Selectable sensor locking feature Benefits Quick and simple to install Accepts side entry surface cables Common base for Menvier intelligent addressable sensors 67

Intelligent Addressable Standard Base - MAB800 Dimensions Technical Specification D Dia (mm) D (mm) 104 22 Physical Construction MAB800 Standard base PC/ABS Colour White Dimensions (Dia x D) 104mm x 22mm Compatibility Suitable for use with Menvier intelligent addressable sensors Dia Installation User Interface 1. Separate terminals are provided for loop in and loop out connections. 2. Each terminal can accept up to 2 x 2.5mm cables. 3. Base incorporates a substantial cable entry aperture in the rear of the base. 4. Breakouts are provided to enable the sensor base to sit neatly over surface cables and then enter via the rear entry aperture. 5. Base mounting incorporates a stand off feature to help prevent distortion when mounted on an uneven surface. 6. Fixings are suitable for standard BESA box or direct fixing to suitable surface. 1. Heavy duty terminals are provided for each connection, each terminal can accept 2 x 2.5mm cables. 2. Separate loop in and loop out terminals are provided for each connection. Standard Connection + V + remote indicator (optional) Compatible Menvier Intelligent Addressable Control Panel Loop finish Loop start S+ S- F- F+ 1 LED 4 E 2 3 - VE OUT 1 LED 4 E 2 3 - VE IN earth screen of cable must be continuous WARNING: If using the outer connection on terminal 2, ensure the operation of the switch is not impeded and that there are no shorts between terminal 2 and the switch contact Ensure that cable or end of line resistor leg does not short onto the contact. Product s MAB800 Intelligent addressable standard base 68

Intelligent Addressable Product Range Sounder Base MAS850 MAS850 with cover fitted MAS850 sounder base MAS850 incorporates standard detector base Overview The intelligent addressable Menvier sounder base has been developed specifically to operate with the latest generation of Menvier intelligent addressable panels and to complement the latest generation of Menvier intelligent addressable sensors. The MAS850 sounder base incorporates a sensor mounting base, a sensor can be fitted to the sounder base or alternatively an optional cover plate can be used to enable the sounder to operate as a dedicated discreet stand alone sounder. Features Integral sensor mounting base Can be used with a sensor as a sounder base or stand alone sounder Optional cover plate available Benefits First fix base Selectable tones controlled by the panel Adjustable volume controlled by the panel 69

Intelligent Addressable Sounder Base - MAS850 Dimensions Technical Specification Dia (mm) D (mm) 102 40 Standards MAS850 Sounder base EN54 Pt3 Specification D Operating Voltage 17V dc to 32V dc Standby Current < 320µA Tones (set by panel) Continuous: 910Hz Pulsed: 910Hz / 0Hz pulse 1Hz Two tone: 610 / 910Hz @ 1Hz cycle Dia Slow whoop Sound Output @ +/-3dB Low volume : 84dB at <4mA (set by panel) Medium volume : 92dB at <8mA High volume : 95dB @ <12mA Environmental Operating Temperature -10 to +55 C Humidity (Non Condensing) 0 to 95% RH Physical Construction PC/ABS Colour White Dimensions (Dia x D) 120mm x 40mm Weight 0.2kg Ingress Protection IP40 Compatibility Suitable for use with Menvier intelligent addressable fire systems Installation 1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface via 2 fixings holes. 3. Cables enter through aperture in base (rear entry only) 4. Main body is then clipped into place on base, main body locks into place when pressed into position. 5. Cables pass through aperture in sounder body and terminate at the front. 6. Connections are to connector block on front of main sounder body. 7. Sensor or cover plate is then fixed to sounder. 8. Sensor or cover plate can be locked in place if required. System Functionality 1. Volume and tone are set by control panel, no need to access sounder to alter setting. 2. Soft addressed. Standard Connection 3 3 Compatible Menvier Intelligent Addressable Control Panel Loop finish Loop start S+ S- F- F+ 4 E LED + - + - 1 2 4 E LED + - + - 1 2 WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Earth screen must be continuous along entire length of loop. NOTE: Base terminal 1, 2, 3 and 4 not used. All wiring terminates as shown above. Product s MAS850 Intelligent addressable sounder base MASC Sounder cover plates (pack of 5) 70

Intelligent Addressable Product Range Sounder Beacon Base MASB870 MASB870 sounder beacon base MASB870 with sensor fitted Overview The intelligent addressable Menvier sounder beacon base has been developed specifically to operate with the latest generation of Menvier intelligent addressable panels and Menvier sensors. The MASB870 sounder beacon base includes all the features of the intelligent addressable sounder base as well as a powerful LED beacon. The intelligent addressable beacon base incorporates a detector mounting base, a sensor can be fitted directly to the base, or alternatively an optional cover plate can be used to provide a dedicated discreet stand alone device. Features Integral sounder base Integral high output LED beacon Integral sensor mounting base Can be used with a sensor or stand alone Selectable tones controlled by the panel Adjustable volume controlled by the panel Optional cover plate available Benefits Saves time and installation costs Single point connection for sensor, sounder and LED strobe 71

Intelligent Addressable Sounder Beacon Base - MASB870 Dimensions Technical Specification Dia Dia (mm) D (mm) 115 44 Standards MASB870 Sounder beacon base EN54 Pt3 Specification D Operating Voltage 17V dc to 32V dc Standby Current < 320µA Tones (set by panel) Continuous: 910Hz Pulsed: 910Hz / 0Hz pulse 1Hz Two tone: 610 / 910Hz @ 1Hz cycle Slow whoop: 500 1200Hz in 3.5 Seconds Sound Output at +/-3dB Low volume : 77dB at <6.6mA (set by panel) Medium volume : 89dB at <8mA High volume : 90dB @ <9mA Environmental Operating Temperature -10 to +55 C Humidity (Non Condensing) 0 to 95% RH Physical Construction PC/ABS Colour White Dimensions (Dia x D) 115mm x 44mm Weight 0.2kg Ingress Protection IP40 Compatibility Suitable for use with Menvier intelligent addressable fire systems Installation 1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface via 2 fixings holes. 3. Cables enter through aperture in base (rear entry only). 4. Main body is then clipped into place on base, main body locks into place when pressed into position. 5. Connections are to connector block on front of main sounder body. 6. Sensor or cover plate is then fixed to sounder, (can be locked in place if required). System Functionality 1. Volume and tone are set by control panel, no need to access sounder to alter setting. 2. Soft addressed. Standard Connection 3 3 Compatible Menvier Intelligent Addressable Control Panel Loop finish Loop start S+ S- F- F+ 4 E LED + - + - 1 2 4 E LED + - + - 1 2 WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Earth screen must be continuous along entire length of loop. NOTE: Base terminal 1, 2, 3 and 4 not used. All wiring terminates as shown above. Product s MASB870 Intelligent addressable sounder beacon base MASC Sounder beacon cover plates (pack of 5) 72

Intelligent Addressable Product Range Loop Connected Remote Indicator MRIAD MRIAD loop connected remote indicator Overview The MRIAD intelligent addressable loop connected remote indicator is designed to provide discreet remote indication, which is controlled by the intelligent addressable fire panel, whilst providing the ability to monitor multiple detectors within an area thereby minimising wiring requirements. The unit is connected directly on the loop, is soft addressed by the panel on system start up and is fitted with integral short circuit isolators. When using Site Installer the MRIAD should be programmed as an address output (sounder) and can be programmed using the comprehensive cause and effect tables to operate continuous, pulsing, by global, panel, zone, address or on double knock input etc. Features Simple to install Fits onto standard single gang back box Wide viewing angle high brightness LED Attractive styling Benefits Can be remote mounted Controlled by the panel Can be activated by cause and effect Reduced cost Minimises cabling The unit is supplied complete with back box and is surface mounted. 73

Intelligent Addressable Remote Indicator - MRIAD Dimensions Technical Specification H (mm) W (mm) D (mm) 87 87 49 MRIAD Loop connected remote indicator Specification Operating Voltage 24V dc Quiescent Current 220µA Alarm Current 6mA Cable Size 0.5 mm² to 2.5 mm² Environmental Operating Temperature -10 C to +55 C Humidity (Non Condensing) 0 to 95% RH Physical Construction ABS Colour White Lens Colour Red Dimensions (H x W x D) 87mm x 87mm x 49mm Weight 0.28kg Ingress Protection IP30 Compatibility Suitable for use with Menvier intelligent addressable fire systems Standard Connection MRIAD Compatible Menvier Intelligent Addressable Control Panel screen connected using suitable terminal in backbox LOOP IN IN OUT - + - + LOOP OUT Installation 1. Mounting plate fixes to single gang back box or can be direct fixed to wall or ceiling. 2. Cable entry is normally from rear but breakouts are provided in side of base plate 3. Cables connect to terminals on PCB within base plate. 4. Front cover is pushed onto base plate and locks in place. System Functionality 1. MRIAD is addressable and is programmed to activate when selected detectors are triggered. 2. LED cancels when detector is reset. 3. Low current consumption. Terminal block unplugs for ease of connection WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of loop. Product s MRIAD Intelligent addressable loop connected remote indicator 74

Intelligent Addressable Product Range Reflective Beam Detectors MAB50R and MAB100R Optional mounting bracket with cable clamp facilities MAB50R and MAB100R reflective beam detectors Combined transmitter and receiver for ease of installation Overview The Menvier loop powered reflective beam detectors are specifically designed to function with the latest intelligent addressable Menvier control panels. Two versions are available, the MAB50R with a range of up to 50 metres, and the MAB100R with a range of 50-100 metres. Both of these units are extremely simple to install, they require no separate power supply, operate on a reflective principle and have a simple set up mode to enable easy and quick alignment during installation. Beam detectors are designed to replace individual point detectors in large open areas such as warehouses. Fire and fault conditions are signalled to panel using standard loop wiring so no additional interconnection required. Features Quick and simple to install IP40 protection Simple loop connection No power supply required Benefits Saves time and installation costs Single device to install instead of numerous point detectors Single point of maintenance Wall mounted for ease of maintenance, especially in warehouses with racking 75

Intelligent Addressable Reflective Beam Detectors - MAB50R and MAB100R Dimensions Technical Specification H D W H (mm) W (mm) D (mm) 210 130 120 MAB50R MAB100R Reflective beam detector Reflective beam detector Standards EN54 Pt 12 & 17 2002 EN54 Pt 12 & 17 2002 Specification Operating Voltage 18V dc to 30V dc 18V dc to 30V dc Quiescent Current <5mA (no LED s illuminated) <5mA (no LED s illuminated) Alarm Current <9mA <9mA Alignment Current <18mA <18mA Power up Time 10 seconds (approx) 10 seconds (approx) Operating Range 5 to 50 metres 50 to 100 metres Tolerance to Beam Misalignment at 35% Detector ± 0.8, Prism ± 5.0 Detector ± 0.8, Prism ± 5.0 Fire Alarm Thresholds 2.50dB (25%) 3.74dB (35%) 6.02dB (50%) 2.50dB (25%) 3.74dB (35%) 6.02dB (50%) Optical Wavelength 880nm 880nm Environmental Operating Temperature -10 C to +55 C -10 C to +55 C Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH Physical Construction PC/ABS PC/ABS Colour White White Dimensions (H x W x D) 210mm 130mm x 120mm 210mm 130mm x 120mm Weight 0.8kg 0.8kg Ingress Protection IP40 IP40 Compatibility Suitable for use with Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems Standard Connection MAB50R / MAB100R Installation 1. Must be fixed to solid structure. 2. Recommended mounting height is 0.3 to 0.6 metres below the ceiling. 3. Cables can be terminated into separate termination box (not supplied) or use purpose designed mounting bracket (MRBFP) ordered separately. 4. Mounting bracket has facilities for glanding of incoming cables plus simple fixing of beam detector. 5. Test filter is supplied with detector to simulate required smoke obscuration level and confirm correct operation. System Functionality 1. Beam detectors have 3 modes Prism targeting mode designed to provide simple initial alignment of beam and reflector assembly. Alignment mode Enables accurate fine tuning of beam alignment without the need for additional calibration equipment or a second operator. Normal running mode User Interface. 1. Beam detectors status LEDs Red LED constantly illuminated indicates fire condition Flashing amber LED indicates fault condition Product s MAB50R MAB100R MRBFP Intelligent addressable reflective beam detector 50m range Intelligent addressable reflective beam detector 100m range Mounting bracket 76

Intelligent Addressable Product Range Callpoints MBG813 and MBG817 MBG817 weatherproof callpoint MBG813 callpoint MBGHCC protective hinged cover Overview This attractively designed simple to install range of callpoints have been specifically developed to be compatible with Menvier intelligent addressable fire systems. There are two versions of callpoint in this range. The MBG813 which can be either surface or flush mounted and the MBG817 weatherproof version. All callpoints are supplied as standard with a frangible glass element and a test key for ease of maintenance. A comprehensive range of accessories are available to maximise the functionality of the callpoint for particular applications. Features Fast fit clip on front cover High visibility status LED Standard and weatherproof versions available Wide range of available accessories Heavy duty terminals Benefits Quick and simple to install Fast fit clip on front cover Single tool for test and access MBGBEZ recessing bezel 77

Intelligent Addressable Callpoints - MBG813 and MBG817 Dimensions H D H (mm) W (mm) D (mm) Flush mounted 87 87 36 Surface mounted 87 87 57 Weatherproof 87 87 59 W Technical Specification MBG813 MBG817 Surface / flush mounting callpoint Weatherproof callpoint Standards EN54 Pt11 EN54 Pt11 Specification Operating Voltage 17V dc to 32V dc 17V dc to 32V dc Quiescent Current < 250µA < 250µA Environmental Operating Temperature -10 C to +55 C -10 C to +55 C Humidity (Non Condensing) 0 to 93% RH 0 to 93% RH Physical Construction PC/ABS PC/ABS Colour Red Red Dimensions (H x W x D) 87mm x 87mm x 57mm (36mm flush) 87mm x 87mm x 59mm Weight 0.2kg 0.2kg Ingress Protection IP42 IP65 Compatibility Suitable for use with Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems Standard Connection MBG813 / MBG817 Compatible Menvier Intelligent Addressable Control Panel LOOP IN Screen WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of loop. E IN Screen OUT - + E - + LOOP OUT Installation 1. Surface callpoint has standard rear BESA fixing facilities. In addition, back box can accept top or bottom surface entry cables. Surface callpoint can also be flush mounted. 2. Callpoint has test facility via special test key to prevent unauthorised operation. 3. Insertion of test key for test purposes and for cover removal is at bottom of callpoint to facilitate ease of access when mounted next to door architrave. 4. Test key is dual function, used to test callpoint operation by simulating activation and also to allow removal of clip on cover to gain access to element. 5. Element is held in place by clip on self locking cover which can only be removed by use of a special tool (callpoint test key). 6. Separate loop in and loop out terminals are provided for all connections including screen continuity on intelligent addressable callpoints. 7. Surface/flush callpoints are IP42, weatherproof is IP65. User Interface 1. To enable quick and simple installation, callpoints use a fast fit self locking clip on front cover which is very simple to fit, but once in place, can only be removed by use of a special key (supplied). 2. Callpoint is triggered by pressing against the element. Accessories Semi recess bezel Spacer plates Hinged clear cover Resettable plastic element Replacement test key Replacement glass elements Earth continuity links Product s MBG813 Intelligent addressable surface/flush callpoint MBG817 Intelligent addressable weatherproof callpoint MBGHCC Protective hinged cover MBGSP Spacer plates (pack of 10) MBGBEZ Recessing bezels (pack of 10) MBGREKIT Resettable element kit (pack of 10) MBG118 Spare break glasses (pack of 5) MBG119 Earth continuity links (pack of 5) MFBGKEY3 Callpoint keys (pack of 10) 78

Intelligent Addressable Product Range Wall Sounders MAS850LPS and MAS850LPSWP MAS850LPSWP weatherproof wall sounder MAS850LPS internal wall sounder Internal base Overview The Menvier intelligent addressable wall sounder has been developed specifically to operate with Menvier intelligent addressable control panels. The high efficiency design of these wall sounders offer excellent sound output levels despite the low current consumption. MAS850LPS The Menvier MAS850LPS is designed for wall mounting, has a choice of different tones and volume levels, a built in short circuit isolator and is soft addressed for ease of installation. MAS850LPSWP The Menvier MAS850LPSWP is IP66 rated so suitable for external and wash down areas, it is designed for wall mounting, has a choice of different tones and volume levels, a built in short circuit isolator and is soft addressed for ease of installation. Features MAS850LPS Loop powered High efficiency design Selectable tones controlled by the panel Adjustable volume controlled by the panel Simple clip fixing assembly MAS850LPSWP Weatherproof version (IP66) Loop powered High efficiency design Selectable tones controlled by the panel Adjustable volume controlled by the panel Simple clip fixing assembly Benefits Low current consumption First fix back box Built in short circuit isolators Weatherproof base 79

Intelligent Addressable Wall Sounders - MAS850LPS and MAS850LPSWP Dimensions Technical Specification W Internal wall sounder D H H (mm) W (mm) D (mm) Internal 105 105 95 Weatherproof 108 108 103 H w Weatherproof wall sounder D MAS850LPS MAS850LPSWP Internal wall sounder Weatherproof wall sounder Standards EN54 Pt3 EN54 Pt3 Specification Operating Voltage 17V dc to 32V dc 17V dc to 32V dc Standby Current < 320µA < 320µA Tones (set by panel) Continuous: 984Hz Continuous: 984Hz Pulsed: 984Hz / 0Hz pulse 1Hz Pulsed: 984Hz / 0Hz pulse 1Hz Two tone: 644 / 984Hz @ 1Hz cycle Two tone: 644 / 984Hz @ 1Hz cycle Slow whoop: 500-1200Hz in 3.5 seconds/0.5secs gap Slow whoop: 500-1200Hz in 3.5 seconds/0.5secs gap Sound Output @ +/-3dB Low volume : 87dB at <2mA Low volume : 87dB at <2mA (set by panel) Medium volume : 93dB at <3mA Medium volume : 93dB at <3mA High volume: 100dB @ <6mA High volume: 100dB @ <6mA Environmental Operating Temperature -10 C to +55 C -10 C to +55 C Humidity (Non Condensing) 0 to 95% RH 0 to 95% RH Physical Construction PC/ABS PC/ABS Colour Red Red Dimensions (H x W x D) 105mm x 105mm x 95mm 108mm x 108mm x 103mm Weight 0.25kg 0.57kg Ingress Protection IP42 IP66 Cable Entry Rear/side Rear/side Compatibility Suitable for use with Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems Standard Connection MAS850LPS / MAS850LPSWP Installation MAS850LPS 1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface using 2 fixing holes. 3. Cable entry can be rear or side. 4. Connections are to connector block on main sounder body. 5. Main body is then clipped into position on mounting base, body locks into position when pressed home. System Functionality MAS850LPS / MAS850LPSWP 1. Volume is set by fire control panel, no need to access sounder to alter setting. 2. Tone is set by fire control panel, no need to access sounder to alter setting.. MAS850LPSWP 1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface using 2 fixing holes. 3. Cable entry can be rear or side. 4. Connections are to connector block on main sounder body. 5. Main body is then fastened onto base, using 4 allen head screws (supplied). Product s MAS850LPS MAS850LPSWP Intelligent addressable internal wall sounder Intelligent addressable weatherproof wall sounder 80

Intelligent Addressable Product Range Wall Sounder Beacons MASB860 and MASB860WP MASB860WP weatherproof wall sounder beacon MASB860 internal wall sounder beacon Internal base Weatherproof base Overview The Menvier intelligent addressable wall sounder beacon has been developed specifically to operate with the latest generation of Menvier intelligent addressable control panels. The high efficiency design offers excellent sound output levels despite the low current consumption. Whilst also includes a high powered LED beacon to provide both audible and visual alarm signals. MASB860 The Menvier MASB860 is designed for wall mounting, has a choice of different tones and volume levels, a built in short circuit isolator and is soft addressed for ease of installation. MASB860WP The Menvier MASB860WP is IP66 rated so suitable for external and wash down areas, it designed for wall mounting, has a choice of different tones and volume levels, a built in short circuit isolator and is soft addressed for ease of installation. Features MASB860 Loop powered Combined sounder beacon High efficiency design Selectable tones controlled by the panel Adjustable volume controlled by the panel MASB860WP Weatherproof version (IP66) Loop powered Combined sounder beacon High efficiency design Selectable tones controlled by the panel Adjustable volume controlled by the panel Benefits Low current High efficency audio / visual unit suitable for DDA compliance 81

Intelligent Addressable Wall Sounder Beacons - MASB860 and MASB860WP Dimensions Technical Specification Internal Weatherproof H (mm) W (mm) D (mm) Internal 105 105 95 Weatherproof 108 108 103 MASB860 MASB860WP Internal wall sounder beacon Weatherproof wall sounder beacon Standards EN54 Pt3 EN54 Pt3 Specification Operating Voltage 17V dc to 32V dc 17V dc to 32V dc Standby Current < 320µA < 320µA Tones (set by panel) Continuous: 984Hz Continuous: 984Hz Pulsed: 984Hz / 0Hz pulse 1Hz Pulsed: 984Hz / 0Hz pulse 1Hz Two tone: 644 / 984Hz @ 1Hz cycle Two tone: 644 / 984Hz @ 1Hz cycle Slow whoop: 500-1200Hz in 3.5 seconds/0.5secs gap Slow whoop: 500-1200Hz in 3.5 seconds/0.5secs gap Sound Output @ +/-3dB Low volume: 92dB at <6.5mA Low volume: 92dB at <6.5mA (set by panel) Medium volume: 97dB at <7.5mA Medium volume: 97dB at <7.5mA High volume: 100dB @ <8.5mA High volume: 100dB @ <8.5mA Flash Energy 1Hz 1Hz Environmental Operating Temperature -10 C to +55 C -10 C to +55 C Humidity (Non Condensing) 0 to 95% RH 0 to 95% RH Physical Construction PC/ABS PC/ABS Colour Red Red Lens Colour Red Red Dimensions (H x W x D) 105mm x 105mm x 95mm 108mm x 108mm x 103mm Weight 0.21kg 0.32kg Ingress Protection IP42 IP66 Cable Entry Rear/side Rear/side Cable Size / Type 0.5mm to 2.5mm/ FIRETUF, FP200 or MICC 0.5mm to 2.5mm/ FIRETUF, FP200 or MICC Compatibility Suitable for use with Menvier intelligent addressable fire systems Menvier intelligent addressable fire systems Standard Connection MASB860 / MASB860WP Compatible Menvier Intelligent Addressable Control Panel LOOP IN Screen WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of loop. E IN Screen OUT - + E - + LOOP OUT Installation MASB860 1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface using 2 fixing holes. 3. Cable entry can be rear or side. 4. Connections are to connector block on main. sounder body. 5. Main body is then clipped into position on mounting base, body locks into position when pressed home. MASB860WP 1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface using 2 fixing holes. 3. Cable entry can be rear or side. 4. Connections are to connector block on main sounder body. 5. Main body is then fastened onto base, using 4 allen head screws (supplied). System Functionality MASB860 / MASB860WP 1. Volume is set by fire control panel, no need to access sounder to alter setting. 2. Tone is set by fire control panel, no need to access sounder to alter setting. Product s MASB860 MASB860WP Intelligent addressable internal wall sounder beacon Intelligent addressable weatherproof wall sounder beacon 82

Intelligent Addressable Product Range Loop Connected LED Beacon MAB870 MAB870 loop connected LED beacon Overview The Menvier intelligent addressable loop connected LED beacon is available to complement audible alarms for use in areas either where people may be present who have impaired hearing or areas with high ambient noise levels. The Menvier MAB870 is designed for both wall and ceiling mounting, has a built in short circuit isolator and is soft addressed for ease of installation. Features High efficiency design LED technology Low profile design Benefits Low current High efficency LED / visual unit suitable for DDA compliance 83

Intelligent Addressable Loop Connected LED Beacon - MAB870 Dimensions Technical Specification Dia (mm) D (mm) 95 53 Specification MAB870 Loop connected LED beacon Operating Voltage 17V dc to 32V dc D Standby Current < 250µA Alarm Current < 4.1mA Flash Frequency 1/2Hz Light Output 0.5cd Dia Environmental Operating Temperature -10 C to +55 C Humidity (Non Condensing) 0 to 95% RH Physical Construction PC/ABS Colour Red Dimensions (Dia x D) 95mm x 53mm Weight 0.15kg Ingress Protection IP54 Compatibility Suitable for use with Menvier intelligent addressable fire systems Standard Connection Installation System Functionality MAB870 Compatible Menvier Intelligent Addressable Control Panel LOOP IN Screen E IN Screen OUT - + E - + LOOP OUT 1. Installation is simple using first fix base. 2. First fix base is fixed to mounting surface via 2 fixings holes. 3. Cable entry is from the rear. 4. Connections are to connector block on beacon body. 5. Beacon body is pressed into first fix base then twisted to lock into position. 1. Utilises multiple LEDs combined with careful optical design to provide high intensity flash with low current consumption. 2. Low profile design for discreet installation. WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Screen (Earth) must be continuous along entire length of loop. Product s MAB870 Intelligent addressable loop connected LED beacon 84

Intelligent Addressable Product Range 4 Way Sounder Controller Unit MPU424 MPU424 4 way sounder controller unit Overview An extensive range of interfaces are available to support the Menvier range of control panels, providing solutions for most design requirements. The MPU424 4 way sounder controller unit is a loop connected interface, which provides the facility to power and control 4 independent conventional sounder circuits. This greatly simplifies installation in applications where specialist sounders or beacons are required by avoiding the need to connect them directly to the intelligent addressable control panel. The unit only uses a single address yet each circuit can be independently controlled according to the required cause and effect programming. Features Quick and simple to install Avoids the need to wire conventional sounders back to the main panel 4 separate sounder circuits (0.4A) All outputs are independently programmable Battery backup via integral battery Built in short circuit isolator Built in power supply Benefits Plug and play, no hard addressing required Increased system integrity No external short circuit isolator required Beacon and strobe can be wired direct to the interface thereby saving time and cabling Reduce cost of installation 85

Intelligent Addressable 4 Way Sounder Controller Unit - MPU424 Dimensions Technical Specification H D H (mm) W (mm) D (mm) 300 300 74 W MPU424 4 channel sounder controller unit Standards EN54 Pt4 & Pt17 2005 Specification Operating Voltage 24V dc Quiescent Current 250µA Mains Supply Voltage 230V ac Mains Current Consumption 0.4A Battery 2 x 12 V, 4Ah, SLA Standby Period 24 hours + 30 minutes ringing Sounder Circuit Output 0.4A (max) Sounder Load 1.6A (max) Fire Relay Switching Voltage 30V dc Switching Current 1A (resistive), 0.5 A (inductive) (max) Environmental Operating Temperature -10ºC to +45ºC Humidity (non condensing) 0 to 95% RH Physical Construction ABS/steel Dimensions (H x W x D) 300mm x 300mm x 74mm Weight 5.4kg Ingress Protection IP30 Compatibility Suitable for use with Menvier intelligent addressable fire systems Installation 1. The sounder controller interface requires a local unswitched 230V supply and incorporates a back up battery to maintain functionality under mains failure conditions. 2. Cable entry can be top or rear. 3. Top entry is via 20mm conduit entries (pre-fitted with blanking plugs for unused entries). 4. Rear entry via substantial cable slot in metal back plate 5. Top cover secured with tamper resistant screws Standard Connections 6K8 6K8 6K8 6K8 intelligent addressable loop 230V ac mains FIRE RELAY N/O C N/C L N E E + - E + - E + - E + - E - + E OUT - IN + + BATT - + - back up battery NOTES: 1. Earth (Screen) cable must be connected to its adjacent earth terminal. 2. The end of line resistor must always be fitted, even if input is not used. 3. Sounder circuits are monitored for wiring open and short circuit. 4. Output fire relay is a set of changeover volt free-contacts and is not monitored. 5. This unit should only be finally connected to the 230V ac mains supply and battery, during system commissioning. Product s MPU424 4 way sounder controller unit 86

Intelligent Addressable Product Range Zone Monitor Unit MIU871 MIU871 zone monitor unit Overview An extensive range of interfaces are available to support the Menvier range of control panels, providing solutions for most design requirements. The MIU871 zone monitor unit connects zones of suitable conventional detectors. Features Quick and simple to install Accepts a zone of Menvier conventional detector heads and callpoints (detectors must be connected via the Cooper CDBB300 mounting base) Only takes a single address Input monitored for open, short circuits and earth fault Built in short circuit isolator Benefits Plug and play no hard addressing required Easy to expand a system using existing wiring No external short circuit isolator required 87

Intelligent Addressable Zone Monitor Unit - MIU871 Dimensions Technical Specification W H (mm) W (mm) D (mm) 88 147 60 MIU871 Zone monitor unit Standards EN54 Pt17 & Pt18 2005 Specification Operating Voltage 18V dc to 30 V dc Quiescent Current 2.8mA D H Alarm Current Current with 20 Detectors Detector Load 8mA 3.4mA 20 detectors per zone (max) Callpoint Load Unlimited Environmental Operating Temperature -10ºC to +60ºC Humidity (non condensing) 0 to 95% RH Physical Construction PC/ABS Dimensions (H x W x D) 88mm x 147mm x 60mm Weight 0.23kg Ingress Protection IP40 Compatibility Suitable for use with Menvier intelligent addressable fire systems Installation 1. Zone monitor unit is fixed to a deep double gang back box (supplied). 2. All connections are via heavy duty terminals. 3. Cable entry can be top, bottom, side or rear. 4. Can be surface or semi recessed mounted. Standard Connections EOLM-1 6K8 - - OUT IN + + intelligent addressable loop - - OUT IN + + - - E + E + E + E + - - OUT LOOP IN CALLPOINT ZONE DETECTOR ZONE Callpoints can be connected with detectors on detector zone if preferred NOTES: 1. Earth (Screen) cable must be connected to its adjacent earth terminal. 2. The end of line resistor must always be fitted, even if input is not used. 3. Maximum spur length - see BS5839 Pt:1 2002 for zone coverage. 4. There is no maximum number of conventional callpoints allowed per zone output. 5. Unit can only be used with its respective Cooper fire systems and compatible sensor and base. Note: The MIU871 accepts a zone of Menvier conventional detector heads (detectors must be connected via the Cooper CDBB300 mounting base) Product s MIU871 Zone monitor unit 88

Intelligent Addressable Product Range Shop Monitor Unit MSU840 MSU840 shop monitor unit Overview An extensive range of interfaces are available to support the Menvier range of control panels, providing solutions for most design requirements. The MSU840 shop monitor unit is designed to enable small units with conventional fire detection to be fully integrated with a main intelligent addressable fire system. It is ideal for applications such as connecting individual shop units into a main shopping centre system. An external power supply is required to drive the 2 conventional sounder circuits. This power supply must be regulated for fire and current limited. Features Quick and simple to install Accepts a zone of Menvier conventional detector heads and callpoints (detectors must be connected via the Cooper CDBB300 mounting base) Provides 2 conventional sounder circuits Only takes a single address Inputs monitored for open, short circuits and earth fault Benefits Plug and play no hard addressing required Easy to expand a system using existing wiring No external short circuit isolator required Reduced installation cost by using the 2 sounder circuits 89

Intelligent Addressable Shop Monitor Unit - MSU840 Dimensions Technical Specification W H (mm) W (mm) D (mm) 88 147 60 Standards Specification MSU840 Shop Monitor Unit EN54 Pt17 & Pt18 Operating Voltage 15V dc to 30V dc Quiescent Current 3.4mA (max) D H Quiescent Load Current Alarm Current Zone Circuits 2.8mA (max) 8mA (max) Number Input Circuits 2 Zone Circuit 1 Callpoints only Zone Circuit 2 Detectors and Callpoints Number of Callpoints Unlimited Callpoint Resistance 470Ω to 680Ω Zone Circuit 1 EOL 6K8 Zone Circuit 2 EOL Active EOL Number of Detectors 20 (max) Short Circuit Fault Threshold 150Ω Open Circuit Fault Threshold N/A active EOL Sounder Circuits Number of Sounder Circuits 2 Load per Output 300mA (max) Sounder Circuit 1 and 2 EOL 12K Environmental Operating Temperature -10ºC to +60ºC Humidity (non condensing) 0 to 95% RH Physical Construction PC/ABS Dimensions (H x W x D) 129mm x 180mm x 60mm Weight 1kg Ingress Protection IP40 Compatibility Suitable for use with Menvier Intelligent Addressable Fire Systems Standard Connections EOLM-1 24V dc output power supply unit 6K8 12K 12K FAULT CONTACT N/O 24V O/P intelligent addressable loop - - Out In + + - Out + - In + 12K - + E - + E - + E - + E - + + - + - E - + OUT LOOP IN CALLPOINT ZONE DETECTOR ZONE + - E + - 1 2 SOUNDER EXTERNAL PSU MONITOR 24V EXTERNAL PSU INPUT Callpoints can be connected with detectors on detector zone if preferred Note: The MSU840 accepts a zone of Menvier conventional detector heads (detectors must be connected via the Cooper CDBB300 mounting base) Product s MSU840 Shop monitor unit 90

Intelligent Addressable Product Range Spur Isolator Unit MSI850 MSI850 spur isolator unit Overview An extensive range of interfaces are available to support the Menvier range of control panels, providing solutions for most design requirements. The MSI850 spur isolator unit enables a spur of intelligent addressable devices to be connected to a main analogue loop, the device is designed to simplify installation of remote parts of buildings or for simple system extensions. Features Quick and simple to install Allows a spur of intelligent addressable devices to be fed from the main loop Integral short circuit isolators for the loop and the spur Automatically controls addressing sequence Built in short circuit isolator Benefits Plug and play no hard addressing required Easy to expand a system using existing wiring Reduced installation cost No external short circuit isolator required 91

Intelligent Addressable Spur Isolator Unit - MSI850 Dimensions Technical Specification W H (mm) W (mm) D (mm) 88 147 60 MSI850 Spur isolator unit Standards EN54 Pt17 2005 Specification Quiescent Current 170µA Environmental D H Operating Temperature Humidity (non condensing) Physical -10ºC to +60ºC 0 to 95% RH Construction PC/ABS Dimensions (H x W x D) 88mm x 147mm x 60mm Weight 0.23kg Ingress Protection IP40 Compatibility Suitable for use with Menvier intelligent addressable fire systems Installation 1. Please refer to current edition of BS5839-1 for details of the maximum allowable area to be covered by a single zone. 2. Spur isolator unit is fixed to a deep double gang back box (supplied). 3. All connections are via heavy duty terminals. 4. Cable entry can be top, bottom, side or rear. 5. Can be surface or semi recessed mounted. Standard Connections E OUT intelligent addressable loop + E + IN SPUR E + no end of line resistor required NOTES: 1. Earth (Screen) cable must be connected to its adjacent earth terminal. 2. For maximum spur length/load see BS5839 Pt1:2002. 3. Unit can only be used with its respective Cooper fire systems and compatible sensor and base. Product s MSI850 Spur isolator unit 92

Intelligent Addressable Product Range 3 Channel I/O Unit MIO324 MIO324 3 channel I/O unit Overview An extensive range of interfaces are available to support the Menvier range of control panels, providing solutions for most design requirements. The MIO324 3 channel I/O unit enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems. The inputs are fully monitored for open and short circuits. Features Quick and simple to install Soft addressed 3 separate inputs and 3 separate outputs Inputs monitored for open and short circuits Integral short circuit isolator Benefits Plug and play no hard addressing required Built in short circuit isolator no additional hardware required Unit takes 3 inputs, 3 outputs - only 1 address required to monitor and control saving on equipment and installation 93

Intelligent Addressable 3 Channel I/O Unit - MIO324 and MIO324T Dimensions Technical Specification W H (mm) W (mm) D (mm) 88 147 60 MIO324 3 channel I/O unit Standards EN54 Pt17 & Pt18 2005 Specification Operating Voltage 18V dc to 30V dc Quiescent Current 310µA D H Maximum Switching Voltage Output Relay Contact Rating Environmental 50V ac or 30V dc 1A at 30V resistive, 0.5A inductive Operating Temperature -10ºC to +60ºC Humidity (non condensing) 0 to 95% RH Physical Construction PC/ABS Dimensions (H x W x D) 88mm x 147mm x 60mm Weight 0.23kg Ingress Protection IP40 Compatibility Suitable for use with Menvier intelligent addressable fire systems Installation 1. 3 Channel input output unit is fixed to a deep double gang back box (supplied). 2. All connections are via heavy duty terminals. 3. Cable entry can be top, bottom, side or rear. 4. Can be surface or semi recessed mounted. 5. Relay contacts are rated at 24V dc 1A. Standard Connections 5K6 5K6 5K6 intelligent addressable loop 22K 22K 22K E - + E - + - + - + - + OUTPUTS N/O C N/C N/O C N/C N/O C N/C IN OUT INPUTS LOOP NOTES: 1. Earth (Screen) cable must be connected to its adjacent earth terminal. 2. The end of line resistor must always be fitted, even if input is not used. 3. Input circuit is monitored for wiring open and short circuit. 4. Output relay is a set of changeover volt free-contacts and is not monitored. Product s MIO324 MIO324S MIO324T 3 channel I/O unit 3 channel I/O unit, resets on silence 3 channel I/O unit, contains 3 separate addresses 94

Intelligent Addressable Product Range 230V ac Relay Unit MIO1240 MIO1240 relay unit Overview An extensive range of interfaces are available to support the Menvier range of control panels, providing solutions for most design requirements. The MIO1240 230V ac relay unit enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems. The ability of the output unit to switch mains also makes the unit ideal for plant control or mains powered door holders. The input is monitored for open and short circuits therefore can be used for fire input applications such as monitoring sprinkler flow switches. Features Quick and simple to install Soft addressed Only takes a single address Integral short circuit isolator Benefits Plug and play no hard addressing required Easy to expand a system using existing wiring No external short circuit isolator required 95

Intelligent Addressable - 230V ac Relay Unit - MIO1240 Dimensions Technical Specification H W D H (mm) W (mm) D (mm) 129 180 60 MIO1240 230V ac relay unit Standards EN54 Pt17 & Pt18 2005 Specification Operating Voltage 18V dc to 30V dc Quiescent Current 310µA Maximum Switching Voltage 250V ac or 30V dc Maximum Switching Current 8A Environmental Operating Temperature -10ºC to +60ºC Humidity (non condensing) 0 to 95% RH Physical Construction PC/ABS Dimensions (H x W x D) 129mm x 180mm x 60mm Weight 0.6kg Ingress Protection IP65 Compatibility Suitable for use with Menvier intelligent addressable fire systems Installation 1. Mains rated input relay is designed for surface fixing. 2. All connections are via heavy duty terminals. 3. Cable entry can be top, bottom or side. 4. Output relay contacts are rated at 230V ac. Standard Connections 5K6 intelligent addressable loop 22K E - + E - + - + volt-free output 230V rated E C N/C N/O IN OUT SPUR INPUT NOTES: 1. Earth (Screen) cable must be connected to its adjacent earth terminal. 2. The end of line resistor must always be fitted, even if input is not used. 3. Input circuit is monitored for wiring open and short circuit. 4. Output relay is a set of changeover volt free-contacts and is not monitored. Product s MIO1240 230V ac relay unit 96

Intelligent Addressable Product Range Micro Zone Monitor Unit MIU872 MIU872 micro zone monitor unit Overview An extensive range of micro interfaces are available to support the Menvier range of control panels, providing solutions for most design requirements. The MIU872 is a single zone input, soft addressed, micro interface, incorporating integral short circuit isolators. It is fully compatible with the current range of Menvier intelligent addressable fire detection panels. It is suitable for interfacing a zone of up to 20 conventional Menvier detectors onto a Menvier intelligent addressable control panel. It will operate with any Menvier conventional detector in configuration with a schottky diode type base. Features Quick and simple to install Accepts a zone of Menvier conventional detector heads and callpoints (detectors must be connected via the Cooper CDBB300 mounting base) Only takes a single address Input monitored for open and short ground trouble Active end of line monitoring Built in short circuit isolator Benefits Plug and play no hard addressing required Easy to expand a system using existing wiring No external short circuit isolator required 97

Intelligent Addressable Micro Zone Monitor Unit - MIU872 Dimensions Technical Specification W Mounting Details H 37.5mm H (mm) W (mm) D (mm) 65 35 18.5 D 22mm Standards Specification Operating Voltage Quiescent Current Load With 20 Detectors, and Unlimited Callpoints Alarm Load With 20 Detectors, and Unlimited Callpoints Detector Zone Detectors per Zone End of Line Monitor Fire Input Trigger Resistance Short Circuit Fault Threshold Resistance Open Circuit Fault Threshold Resistance Environmental Operating Temperature Humidity (non condensing) Physical Construction Dimensions (H x W x D) Weight Ingress Protection Compatibility Suitable for use with MIU872 Micro zone monitor unit EN54 Pt17 & Pt18 18V dc to 30V dc 2.6mA (nom) 3.2mA (nom) 8.0mA (nom) 20 (max) Active end of line unit - EOLM-1 680Ω (nom) 100Ω (max) 39kΩ (min) -10ºC to +60ºC 0 to 95% RH PC/ABS 65mm x 35mm x 18.5mm 0.28kg IP40 Menvier intelligent addressable fire systems Installation 1. Suitable for use with any Menvier conventional detector. 2. Connections suitable for single strand fireproof cable up. to 2.5mm 2. 3. Loop and output cable screen must be connected to interface earth terminals. Note: No addressing of the interface is required (see control panel operation for details) Standard Connections EOLM-1 IN+ IN- EARTH LOOP IN maximum 20 Cooper conventional detectors INPUT LOOP OUT Note: The MIU872 accepts a zone of Menvier conventional detector heads (detectors must be connected via the Cooper CDBB300 mounting base) Product s MIU872 Micro zone monitor unit 98

Intelligent Addressable Product Range Micro Single Channel Output Units MCOM MCOM-R micro single channel output unit MCOM micro single channel output unit MCOM-S MCOM-S micro single channel output unit Overview An extensive range of micro interfaces are available to support the Menvier range of control panels, providing solutions for most design requirements. The MCOM is a single output, soft addressed, micro interface, incorporating integral short circuit isolators. It is extremely compact and therefore ideal for incorporation into other equipment. The MCOM is fully compatible with the current range of Menvier intelligent addressable fire control panels. It is suitable for switching low voltage (24V dc at 1A maximum), via a set of non latching relay contacts. It is suitable for switching HVAC control circuits, plant shutdown control circuits, fire door closure etc. Features Quick and simple to install Compact size Soft Addressed Integral short circuit isolator Benefits Plug and play no hard addressing required No external short circuit isolator required Optional Variants The MCOM-R gives a 5 second pulse on reset. The MCOM-S is identified by the panel as a sounder. Dose not reset on silence, resets on reset only. 99

Intelligent Addressable Micro Single Channel Output Units Dimensions W Mounting Details H H (mm) W (mm) D (mm) 65 35 18.5 D 22mm Technical Specification MCOM Micro single channel output unit Standards EN54 Pt17 & Pt18 Specification Operating Voltage 18V dc to 30V dc Quiescent Current 310µA Output Relay Switching Voltage 24V dc to 30V dc Contact Rating 1A Switching Power 30 Watts Environmental Operating temperature -10ºC to +60ºC Humidity (non condensing) 0 to 95% RH Physical Construction PC/ABS Dimensions (H x W x D) 65mm x 35mm x 18.5mm Weight 0.078kg Ingress protection IP40 Compatibility Suitable for use with Menvier intelligent addressable fire systems Installation 37.5mm 1. Suitable for switching 24V dc control circuits (fire door retainers etc). 2. Connections suitable for single strand fireproof cable up to 2.5mm 2. 3. Loop and output cable screen must be connected to interface earth terminals. 4. The relay output is a set of change over, non-latching, volt free contacts which are non monitored. Note: No addressing of the interface is required (see control panel operation for details) Standard Connections N/O N/C C OUTPUT LOOP IN LOOP OUT Product s MCOM MCOM-S MCOM-R Micro single channel output unit (recognised as output unit) Micro single channel output unit (recognised as sounder) Micro single channel output unit (5 second reset pulse) 100

Intelligent Addressable Product Range Micro Single Channel Input Units MCIM MCIM-NF micro single channel output unit MCIM micro single channel output unit MCIM-C micro single channel output unit Overview An extensive range of micro interfaces are available to support the Menvier range of control panels, providing solutions for most design requirements. The MCIM is a single input, soft addressed micro interface, incorporating integral short circuit isolators. It is extremely compact and therefore ideal for incorporation into other equipment. The MCIM is fully compatible with the current range of Menvier intelligent addressable fire control panels. It is suitable for monitoring a set of normally open, volt free contacts such as sprinkler system flow switches, auxiliary panel fire/fault signals as well as non fire input signals such as flow valve open contacts, generator start up, fire door closed etc. Features Quick and simple to install Compact size Soft Addressed Integral short circuit isolator Benefits Plug and play no hard addressing required No external short circuit isolator required Optional Variants The MCIM-NF is designed for non-fire applications. The MCIM-C is identified by the panel as a callpoint. 101

Intelligent Addressable Micro Single Channel Input Units Dimensions W Mounting Details H H (mm) W (mm) D (mm) 65 35 18.5 D 22mm Technical Specification MCIM Micro single channel input unit Standards EN54 Pt17 & Pt18 Specification Operating Voltage 18V dc to 30V dc Quiescent Current 310µA Inputs Trigger Resistance 56kΩ End of Line Resistor 22kΩ Short Circuit Fault Threshold Resistance 1Ω Open Circuit Fault Threshold Resistance 33kΩ Environmental Operating temperature -10ºC to +60ºC Humidity (non condensing) 0 to 95% RH Physical Construction PC/ABS Dimensions (H x W x D) 65mm x 35mm x 18.5mm Weight 0.078kg Ingress protection IP40 Compatibility Suitable for use with Menvier intelligent addressable fire systems 37.5mm Installation 1. Inputs monitored for open and short circuit fault conditions. 2. Suitable for monitoring normally open volt free contacts (flow switches etc). 3. Connections suitable for single strand fireproof cable up to 2.5mm 2. 5. Loop and output cable screen must be connected to interface earth terminals 6. The end of line monitoring resistor, must always be fitted at the end of the input wiring, if the input is unused the end of line resistor must be fitted at the interface input terminals. Note: No addressing of the interface is required (see control panel operation for details) Standard Connections 5K6 IN+ 22K IN- EARTH LOOP IN INPUT LOOP OUT Product s MCIM MCIM-C MCIM-NF Micro single channel input unit (recognised as input unit) Micro single channel input unit (recognised as callpoint) Micro single channel input unit (non fire input) 102

Ancillaries and Test Equipment Heavy Duty Relay Unit MAR724 MAR724 heavy duty relay Overview The Menvier heavy duty relay unit is designed for interfacing heavy loads such as door release units or plant shut down equipment with fire alarm systems. It is simple to fix and install and the neat unobtrusive design makes it suitable for use in a wide range of areas. The heavy duty relay is powered by 24V dc external supply and is provided with 2 separate sets of changeover contacts. The front mounted status LED illuminates when relay is energised. Features Simple to install Visible status indication LED Double pole change over contacts Benefits Low current consumption 230V ac rated contacts Will switch up to 10A (resistive) 103

Heavy Duty Relay Unit - MAR724 Dimensions Technical Specification W H (mm) W (mm) D (mm) 89 150 58 Specification Coil Rating MAR724 Heavy duty relay unit 24V dc 10mA Contact Rating 10A at 240V ac or 30V dc Contacts 2 x sets of changeover contacts Environmental D H Operating Temperature Humidity (Non Condensing) -10 C to +55 C 0 to 95% RH Physical Construction PC/ABS Dimensions (H x W x D) 89mm x 150mm x 58mm Weight 0.24Kg Ingress Protection IP30 Compatibility Suitable for use with Menvier fire systems Standard Connection MAR724 RELAY 1 RELAY 2 Installation 1. Heavy duty relay unit fixes to a standard deep double gang back box (supplied). 2. Cable entry is via back box, cables are terminated into heavy duty terminals on relay PCB. Compatible Menvier Control Panel NC C NO NC C NO + - 24V dc OUTPUT Interface Options 1. Relay is powered by an external 24V dc supply. WARNING: Do NOT use high voltage testers if ANY equipment is connected to the system. Product s MAR724 Heavy duty relay unit 104

Ancillaries and Test Equipment EN54 Pt.4 Approved Power Supply With battery backup Overview Switch mode power supply unit with 24V dc output voltage, available with a maximum output current of 1.5A, 2.5A and 5A. The unit is a high efficiency switching power supply; protected from overloads, polarity reversals and short circuits. 4 LEDs indicate power supply status: mains power (green), battery charging (green), battery discharged (yellow) & fault (yellow). Specifically recommended as an auxiliary power supply unit for fire detection system components such as electromagnets, notification devices, etc. Using the unit in large systems eliminates the problem of long power cable runs which simplifies installation. Features Switching Technology Fault relay Tamper switch Integral battery Fault indicator Small & large versions of metallic casing available EN54 Pt.4 Approved Output currents available: 1.5A, 2.5A, 5A Benefits Simple to use Secure steel enclosure Battery back up The case comes provided with a mechanical lock and tamper switch for opening and closing the front door. Power Supply Units series 82000B are certified in accordance with the standard UNI EN54-4:1997 + A1:2002 +A2:2006 105

Power Supply - FX1A Dimensions Installation 1. Enclosure is designed for wall mounting. 2. 2 x 20mm knockouts are provided for cable entry at the rear of the enclosure. 3. A fused terminal block is provided for mains supply connection. 4. Output is protected by internal fuse (displayed in table below). System Functionality 1. FX range power supplies provide outputs between 1.5A and 5A. 2. Output is used to supply any connected load and also to recharge the integral batteries. 3. To enable batteries to be charged correctly maximum continuous external load should not exceed the values displayed in the table below. 4. LED indicators are provided to signify: Mains healthy (Green) System fault (Yellow) Battery Charging (Green) Charger output fault (Yellow) 5. Mains healthy and system fault LED's are visible without removing front cover. H (mm) W (mm) D (mm) P Case 290 250 180 G Case 450 260 205 Technical Specification FX1-5ABP FX1-5ABG FX2-5ABG FX5-0ABG Power supply Standards EN 60950 pt1, EN 50130 Pt 4, EN50081, EN54 Pt4, A1:2002, A2:2006 Specification Output Voltage (-) Min 20.2, Norm 27.6, Max 29.4 Load Current (A) 1.3 1.3 2.2 4.4 Ripple (mv) 174 174 166 246 Input Voltage (V~) 230 V~ -15+10%, 50/60 Hz 230 V~ -15+10%, 50/60 Hz 230 V~ -15+10%, 50/60 Hz 230 V~ -15+10%, 50/60 Hz Current Absorption (A max) 0.42 0.42 0.68 1.21 Battery (Pb) 2 x 12V 4.0 Ah 2 x 12V 4.0 Ah 2 x 12V 7.0 Ah 2 x 12V 17.0 Ah Rechage Current Battery (A) 0.15 0.15 0.25 0.55 Fuses Switching Fs1 F2 F2 F3.15 F4 Switching Fs2 F6.3 F6.3 F6.3 F6.3 Circuit of Control F1 F2 F2 F3.15 F5 Circuit of control F2 F2 F2 F3.15 F5 Physical Operating Temperature +5 C to +40 C Housing Material Epoxy varnished sheet Standard equipment Two keys per lock Packaging 1pc. / package Insulation Class Classe I Ingress Protection IP30 Electrical Protection Fuses for mains and battery overload. Short circuit in output, battery inversion. Door opening tamper. Product s FX1-5ABP FX1-5ABG FX2-5ABG FX5-0ABG 24V 1.5A PSU P CASE 24V 1.5A PSU G CASE 24V 2.5A PSU G CASE 24V 5.0A PSU G CASE 106

Ancillaries and Test Equipment Loop Tester Kit LP800KIT LP800KIT loop tester kit in box LP800KIT loop tester LP800KIT loop tester kit box Overview The LP800 loop tester is a hardware / software combination that can be used to test, commission and fault find a loop of up to 200 Menvier intelligent addressable devices (sensors, sounders, ancillary devices) without having to connect the loop to the Menvier intelligent addressable fire panel. The loop tester is connected between the loop and PC. It allows the engineer to quickly identify and locate any loop device that is operating outside its operating conditions by varying the alarm threshold of any loop device (alarm, prealarm and fault). The loop tester hardware requires a free serial port on the PC, either internal or via a USB extension, a mains power supply and a direct connection to the device loop. Product s Features Pre-addressing: Identifies all Menvier field devices and determines their address and device type Analogue Values: Constantly displays in real time the analogue value of all Menvier loop devices in order to determine their status Test LED: This command operates the LED of any inputs (detector/call points) as well as controls the outputs of sounders and output modules Device Settings: Analogue values of all devices can be interpreted according to ranges which can be set and altered by the user (OK, prealarm, fire) Event Log: A history of events can be stored from the date the application was started Soft addressing: Automatically assigns a new, and potentially different, address to every device found on the loop LP800KIT Programmer 107

Ancillaries and Test Equipment Addressable Device Programmer CF800PROG CF800PROG programmer, back CF800PROG addressable device programmer Overview The CF800PROG programmer is a versatile tool to aid the installation, commissioning, maintenance and servicing of current addressable devices and fire alarm systems. This unit is light, robust and easy to operate using a user friendly menu structure on 2 x 40 character LCD display. It is powered from a single PP3 size, heavy duty battery or an external supply. Features Reads addresses Writes addresses Reads analogue values Tests devices Deletes addresses Programmes the 3 heat settings The programmer has a built in addressable base as well as two external terminals for use with all other current addressable ancillary devices. Product s CF800PROG Addressable device programmer 108