VASKA C11. gas-fireplace user manual. Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0) F.

Similar documents
VASKA B11. gas -fireplace installation guide

VASKA C11. gas -fireplace installation guide

Torch framed Installation Guide

Kalahari DECORATIVE FUEL EFFECT GAS FIRE

MODEL 466 Radiant / Convector Gas Fire Black Beauty

OWNER S GUIDE ETERNITY. MODEL 540C (GC No ) INSET BALANCED FLUE GAS FIRE

Mesina Fires GLASS FRONT VENTED Model No. M 70

Hestia Installation Guide

GrateGlow THE ALL NEW CAPITAL COLLECTION. G20 at 20mbar convertible to G31 at 37mbar. For use in GB and le. Users Instructions

Model 341 Black Beauty Slimline

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE

Emberglow COAL EFFECT BALANCED FLUE GAS FIRE

OWNER GUIDE. Sunfire II Radiant. Radiant / Convector Gas Fire. Model 347 (G. C. Number )

Kalahari RC & Camber RC

Decorative Fuel Effect Appliances

OWNER GUIDE. Model 750. INSET LIVE FUEL EFFECT GAS FIRE Fitted with Harmony, Avignon or Style fascia. (GC No )

MODEL 326 Radiant / Convector Gas Fire Sun~Fire

INSET LIVE FUEL EFFECT GAS FIRE

Vaska Logburner. voorbeeld Installation guide

OWNER S GUIDE MODEL BR417 VA

OWNER GUIDE. Model 739 OPEN DECORATIVE GAS FIRE. (GC No )

Sonnet Plus Anthem Genesis Soraya

OWNER GUIDE. Anthem, Bolero, Camden, Minima, Victorian or Westminster fascia

Sonnet Plus Anthem Genesis Soraya

Model 347 BLACK BEAUTY

Model BR660VA Heat Engine

Fyn Installation guide

Dovre 250 Cast Iron Gas Stove

GB IE. VALOR BOLERO (MODEL BR626) Inset Decorative Fuel Effect Gas Fires. For

Solution Installation guide

Clear Installation guide

morsø PANTHER GAS STOVE

Fyn Installation guide

Respect OC Installation manual

Model 741FS. Dream, Heritage or Opulent OWNER GUIDE. INSTALLER: Please leave this guide with the owner Baxi Heating U.K. Limited 2007.

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE

(manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE V1/100/B INSTALLATION & USER INSTRUCTIONS

INSTALLATION INSTRUCTIONS COMPACT GAS STOVE MODEL NUMBER 550

Duet XL /0929. Installation guide

Gas Fire Patio Heater Q9

INSTALLATION & USERS INSTRUCTIONS. FOR USE WITH NATURAL GAS 20 mbar For use in GB and IE

Hunter Hawk Gas Stove User Instructions

Baxi Brazilia F 5, F 5S, F 8S & Comfort Stat F 8ST Oak

HUNTER HAWK 4 MKII GAS STOVE

ULTRAFLUE ACCLAIM GAS COAL CONVECTOR

5. Wok setting (wok burner) 6. Roasting setting (wok burner)

Gas Fire Patio Heater Lhotse-817

UK/IRL. Saturnus 8 NL CC Heerenveen. P.O. Box 219 NL AE Heerenveen T. +31(0) F. +31(0) < < < <

BUILT-IN GLASS HOB MODEL: EGH-G8592G(BK) EGH-G8593G(BK) Owner s Manual Please read this manual carefully before operating your set.

CRYSTAL FIRES. Inset Conventional Flue Fire. (BOSTON/MIAMI) Cf1 and MANHATTAN USER INSTALLATION AND SERVICING INSTRUCTIONS

Model 956 OWNER GUIDE. This guide to be left with the owner INSET LIVE FUEL EFFECT GAS FIRE

5traxo INSTALLATION AND SERVICING INSTRUCTIONS MANDATORY REQUIREMENTS INSTALLATION

INSTALLATION INSTRUCTIONS GB/IE

CLASSIC II QUATTRO DECORATIVE FUEL EFFECT APPLIANCES FOR USE WITH NATURAL GAS IIN INSTALLATION, SERVICING & USER INSTRUCTIONS

STRATA BATTERY IGNITION RADIANT CONVECTOR GAS FIRE

USER MANUAL. 80 cm 2 burners, glass hob AKC 820C/BLM

User manual (GB / IE) for appliances provided with an electronic ignition on the remote control. English. Read this document and store it carefully

Baxi Bermuda Inset 3 Super

GLOBAL 40 CF FITTING INTO A CONVENTIONAL CLASS 1 CHIMNEY

Baxi Bermuda Inset 3 Super

Installation Instructions Horizon Natural Draft Electronic Ignition Gas Fireplaces

NO VENTING REQUIRED 120V AC;

EMBERGLOW CLASSIC RADIANT CONVECTOR GAS FIRE. Installation and Maintenance Instructions

CRYSTAL FIRES VALENTINES BUILDING BECHERS DRIVE AINTREE RACECOURSE BUSINESS PARK LIVERPOOL MERSEYSIDE L9 5AY HEATRAVE S/L DECORATIVE INSET GAS FIRE

OWNER S MANUAL ELECTRIC FIREPLACE INSERT. Model No.: WESTERN (EF42D-45D) WARNING CAUTION

OWNER GUIDE MODEL BR622 (GC ) INSET LIVE FUEL EFFECT GAS FIRE INCORPORATING. WITH ADORN, VISAGE, ELEGANT or ICON Front

Installation Manual EF5000 NZ

USER MANUAL. 60cm, 3 burners, Hob AKC 630

INSTALLATION & USER INSTRUCTIONS

Rocket heater GAMERA

USE & MAINTENANCE INSTRUCTIONS FOR CHESNEYS ALCHEMY EVOLUTION PLUS GAS FIRES (NATURAL GAS ONLY) FOR DECORATIVE PURPOSES ONLY

INSTALLATION OPERATING, AND SERVICE INSTRUCTIONS FOR SUBURBAN DIRECT VENT SEALED COMBUSTION GAS HEATER MODEL GT-10D

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

Homeowner s Installation Instructions & Operating Manual

TECHNICAL MANUAL. Multifuel Stove Model EW1MF. To be retained by the user for future reference. Serial Number. Document EW1MF 0209

ELECTRIC FLAT PANEL FIREPLACE HEATER. Model# : BG-36B BG-45B BG-50B BG-60B BG-72B BG-100B OWNER S MANUAL

User Manual. 110 Cup (55 Cup Raw) Gas Rice Cooker. Model: 177GRCLP, 177GRCNAT 12/2018. Please read and keep these instructions. Indoor use only.

THESE INSTRUCTIONS TO BE LEFT WITH THE END USER

GB IE INSTALLATION & USER INSTRUCTIONS. Model Number: V1/300/B (ez-slide control) HIGH EFFICIENCY INSET COAL EFFECT GAS CONVECTOR FIRE

Homeowner s Installation Instructions & Operating Manual

INSTALLATION & OPERATING MANUAL

Varde Shape. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

USE & MAINTENANCE INSTRUCTIONS FOR NU-FLAME FIREBOXX SYSTEM (NATURAL GAS & LPG) FITTED WITH EVOLUTION PLUS BURNER. FOR DECORATIVE PURPOSES ONLY

Bosch 80% AFUE Gas Furnace BGS80 Model

Varde Aura. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

MODEL 466 Radiant / Convector Gas Fire Black Beauty

Homeowner s Installation Instructions & Operating Manual

ELECTRIC STOVE HEATER Models: FS2213B

Squirrel - Gas Stoves

SPECIFICATIONS PART NAME

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

INSTALLATION & USER INSTRUCTIONS INSET DECORATIVE GAS FIRE

ELECTRIC FLAT PANEL FIREPLACE HEATER

USER S INFORMATION MANUAL (2,4)SG13B

Clarendon and Ashdon Log Effect Stove Range

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB1200. Issue 01

PROF. RANGE COOKER MODEL: EPRC-9850FE/SS EPRC-9860E/SS. Owner s Manual Please read this manual carefully before operating your set.

Installation Manual EF5000 AUS & NZ

USER S INFORMATION MANUAL

VH60SS 60CM VISOR HOOD STAINLESS STEEL

Transcription:

VASKA C11 gas-fireplace user manual Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0)513 656500 F. +31(0)513 656501 40 010 458 01.51

DESCRIPTION OF THE FIREPLACE CONTENTS 1 2 1. FOREWORD 2 2. INTRODUCTION 3 3 3. SAFETY INTRUCTIONS 4 4 1. Door 2. Window 3. Handle 4. Wood blocks 5. Inspection screen 5 9 8 7 6 6. Control block 7. Bottom plate 8. Burner 9. Pilot burner 4. PREPARING THE APPLIANCE FOR USE 6 4.1 Opening the door 6 4.2 Placing of the wood set 6 4.3 Fuel 7 4.4 Operation of the appliance 7 4.5 Lighting/extinguishing the pilot flame 8 4.6 When the pilot flame goes off 8 4.7 Lighting/extinguishing the burner 9 5. CLEANING AND MAINTENANCE 10 5.1 Cleaning the glass 10 5.2 Care of the coated parts and ceramics 10 5.3 Care of the soapstone 10 6. FAULTS 11 TECHNICAL DATA 7. DISPOSAL OF THE PACKAGING AND THE APPLIANCE 12 ø100/ø150 205 457 463 1130 1

1. FOREWORD 2. INTRODUCTION Congratulations on the purchase of your new Faber International appliance. You have made an excellent choice. A Faber product is a guarantee of years of burning comfort. Faber combines durable materials with balanced techniques. The Vaska C11 is a Direct vent appliance. Thanks to the Direct-vent connection, the appliance can be installed in a draughtproof or fillinsulated house Read the manual carefully before using your appliance and then keep the manual in a safe place. Warranty: Be sure to keep both you warranty certificate and your receipt. Please quote the serial number when making service requests. This number can be found on the data plate on the inside of the door In addition to information about setting-up the appliance, its operation and maintenance, these instructions for use also contain advice about its safe use. By reading this manual you will quickly become familiar with the operation and use of the appliance The Direct vent built-in appliances are designed for installation in living areas. The special Direct vent connections allow you to install the inserts in well-sealed living areas or areas that were insulated after construction. The appliance has a sealed combustion chamber and should be installed as a sealed appliance. The flue gases are drawn outside by the natural draught of the apparatus itself with a combination intake and exhaust. This same natural draught draws in the air needed for combustion. This system of concentric pipes can be equipped with a wall or roof vent outlet. To maintain the proper natural draught, there must be a minimum of one meter of concentric pipe above the appliance before the wall or roof outlet. The Vaska C11 is equipped with a series 9000 SIT OXYPILOT. This protective device comes into operation if the concentration of carbon dioxide in the combustion air supply becomes too high (more than 2% CO2). This can happen if the chimney has insufficient draught. If the protective device comes into operation regularly, you should consult your installer. 2 3

3. SAFETY INSTRUCTIONS If a Gas leak is found or suspected turn off the gas supply at the meter and contact your installer or gas emergency service. These instructions should be read carefully and retained for future reference. The chimney must be tested to ensure that it functions properly. The regulator and thermostat circuit must also be checked and a test must be performed to see that the appliance ignites properly. Have the flue swept each year before winter arrives. Check that it is working correctly before use. Never place flammable material or rubbish on the burner or log set. Do not place curtains, clothing, laundry, furniture or other flammable materials nearby the appliance. The required minimum distance is 100 cm. The appliance has been designed for heating purposes. This means that all surfaces, including the glass, can become very warm (over 100 degrees) An exception to this are the control buttons. IMPORTANT A suitable Fireguard conforming to Nation Regulations should be used with this appliance to protect children, the elderly or infirm. Care should also be taken with pets. The construction of the appliance must not be modified. The appliance may only be repaired using original parts. We recommend that you burn the appliance at its highest setting for a few hours after installing it, ensuring that there is good ventilation, so that the protective coating inside the appliance has a chance to evaporate. We also recommend that you completely clean the front glass after burning the appliance the first week. Provide sufficient insulation between the appliance and a natural stone fireplace. Please bear in mind that the inspection screen must remain removable for servicing purposes. Note: Since the appliance is a source of heat, circulation of air occurs. Therefore it is of importance that you do not use the appliance shortly after a renovation of the home. Because of the natural circulation of air, moist and volatile components from paint, building materials, carpet etc. will be attracted. These components can settle themselves down onto cold surfaces in the form of soot. As on all heat producing appliances, soft furnishings such as blown vinyl wallpaper placed too near to the appliance may become scorched or discoloured. This should be born in mind when installing the appliance. In your own interest and that of safety, all gas appliances must be installed by competent persons. Installation must be in accordance with National Regulations. CORGI registered installers are required to work to recognised standards If the glass pane is broken, it should be replaced before the appliance is turned on. 4 The VASKA C11 is available for use with natural gas and should not be converted for use with another type of gas. 5

4. PREPARING THE APPLIANCE FOR 4.3 FUEL USE The burner of this appliance is only suitable for natural gas. You can see what the burner is set to on the identification plate. The identification plate can be found on the backside of the door. 4.4 CONTROLLING THE APPLIANCE The control block is located on the right-hand side of the fireplace. 4.1. OPENING THE DOOR 4.2 LOG SET fig. 1 opening the door The fireplace door can be opened by first loosening the screw in the door handle, on the left-hand side of the window, then lifting the handle itself (see fig. 1) Control knob B is a thermostat; you can set the burner to a setting between o and fully on. The thermostat ensures a constant ambient temperature. You can set the burner to between o and fully on using slide control C. This determines the minimum height of the flames. A B C 1 2 3 4 5 7 6 6 fig. 2 log set Note! To ensure proper burning, the log set may only be arranged according to the instructions provided by Faber International (see fig. 2). Other placement can cause soot. Before arranging the log set, scatter the bag of embers over the burner. Place the longest log on the far right of the firebox, with its end resting on the support in the middle. Place the shorter log on the left, with its end resting against that of the first log, in the middle of the burner zone. Place the final log diagonally over the first two, with one end at the foot of the righthand log and the other around the middle of the left-hand one fig. 3 control block There are three possibilities: 1. Set slide control C to setting o and control knob B to a setting between 1 and 7. When the appliance has reached the temperature set, it will go out; and when the temperature is too low for the setting chosen, the appliance will start to burn. 2. Turn control knob B past setting. Regulate the height of the flames using slide control C. The flames will burn constantly at this height. 3. Set the minimum height of the flames to between settings 1 and 7 using the slide and the control knob. If the temperature falls below this setting, then the fireplace will heat up more. The flames will then rise slightly higher 7 Close the door after arranging the log set.

4.5 LIGHTING/EXTINGUISHING THE PILOT FLAME Lighting the pilot flame Turn control knob B to setting and push it in. Push knob A in a few times in succession until the pilot flame is ignited by a spark. You now hear a tick. Once the pilot flame is alight, keep the knob pushed in for another 30 seconds. The pilot flame will now stay alight. Turning off the pilot flame Turn the knob to, press it in and turn it to the right to the { setting. 4.6 WHEN THE PILOT FLAME GOES OFF Warning! When the pilot flame goes out, for whatever reason, you should wait at least 5 minutes before trying to turn it on again Possible causes of extinction of the pilot flame are: - operating error - interference of the security, caused by a bad chimney functioning; - failure in the pilot flame system; Contact your installer when the appliance goes off regularly.. 4.7 LIGHTING/EXTINGUISHING THE BURNER Starting the burner Turn control knob B to setting 1. The burner will light. The temperature can be set by turning the knob to the desired setting between 1 and 7, setting 7 giving the highest temperature The slide control can only be used when control knob B has been turned past the. Moving the slide control upwards causes the burner to light. The further upwards the slide control is set, the higher the flames.. Turning off the burner The thermostatically controlled tap is switched off by setting the control knob B to the left of 1. You can now set the slide control. The slide control is switched off by sliding it downwards to the { setting. When control knob B is turned to the setting, only the pilot light continues to burn. Both burners are out. When control knob B is turned to the setting, only the pilot light continues to burn. Both burners are out. 8 9

5. CLEANING AND MAINTENANCE 6. FAULTS 5.1 CLEANING THE GLASS The appliance must be cleaned and checked annually by an authorized installer. This applies for the Direct-vent system as wel. Check that: - the gas supply, combustion chamber and flue gas vent systems are all airtight; - the regulator and the thermocouple circuit function properly and that the burner ignites properly. Clean (if necessary): - the pilot system; - the burner; - the combustion chamber; - the flue gas exhaust. PROBLEM Appliance will not light or goes out. CAUSE - Air in supply pipe (after appliance has been out of operation).. - Insufficient gas pressure. - The pilot flame is dirty. - The thermocouple contact does not engage properly. SOLUTION - Venting - Check that the gas tap is open and check the gas line to see if it is dirty. - Clean the burner carefully with a vacuum cleaner. - Check the thermocouple circuit. Depending on the intensity of use, a layer may in time form on the glass. This layer can be removed with a special glass cleaner or ceramic cook-top cleaner. Follow the instructions on the package. We advise you to have the appliance cleaned by an authorised installer. An improperly working flue and logs in the wrong positions will cause the glass to become dirtier. Poor flame distribution. - The oxypilot feature is activated. - The logs are not positioned properly - Direct-vent system is not closed. Contact your installer. - Arrange the log set properly. 5.2 CARE OF THE COATED PARTS AND CERAMICS Polish the coated finish with a soft duster. Remove any stains using a damp cloth or lukewarm water once the fireplace has cooled down. Never use scouring agents, petrol, paraffin or other solvents to clean the fireplace - The burner is quite dirty because of ash from combustible materials has gotten into the burner. - Clean the burner carefully with a vacuum cleaner. Be careful not to damage the burner with the sharp edges of the vacuum cleaner. 5.3 CARE OF THE SOAPSTONE Use soap and water to remove any dirt or grease from the soapstone (remove the stones from the fireplace first). Minor scratches can be removed using fine sandpaper (240 grey waterproof). 10 11

7. DISPOSAL OF THE PACKAGING AND THE APPLIANCE The appliance packaging is recyclable. The packaging could include the following materials: - cardboard; - CFC-free foam (soft); - wood; - plastic; - paper. These materials should be disposed responsibly and in conformity with government regulations. Information on how to responsibly dispose of discarded appliances can be obtained from the local authorities. 12 13