RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual

Similar documents
Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

R100 Oil-Less Refrigerant Recovery Unit

Enspeco RMS. The Enspeco Refrigerant Management. The following instructions will INSTRUCTIONS

Pro-Set TRA21 SERIES Mobile Multiple Refrigerant Recovery / Recycle System

Refrigerant Recovery Machine. Model No Operating Manual

OWNER S MANUAL (English)

TRS21 IGNITION PROOF SERIES

Oilless Refrigerant Recovery System. OWNER S MANUAL (English) TO BE OPERATED BY QUALIFIED PERSONNEL ONLY

OWNER S MANUAL (English)

OPERATING INSTRUCTIONS

TRS21 IGNITION PROOF SERIES

OPERATION & MAINTENANCE MANUAL TC670

OPERATION & MAINTENANCE MANUAL TX600

OPERATING INSTRUCTIONS

OWNER S MANUAL (English)

User manual Flushing device VAS 6337/1a

OPERATION & MAINTENANCE MANUAL RHS680

NEUTRONICS MINI ID R-1234yf REFRIGERANT IDENTIFIER OPERATION MANUAL

OPERATING INSTRUCTIONS

Owner s Manual. Model AC375C Refrigerant Recovery, Recycle, and Recharge Unit

99 Washington Street Melrose, MA Phone Toll Free Visit us at

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

Caresaver Universal Refrigerant Recovery Unit

OPERATION & MAINTENANCE MANUAL AC860

Model K / K. Modelo K / K. Modèle K / K. Operating Manual

REFRIGERANT RECOVERY SYSTEMS

OPER LV Wheeler Way

DiscovR R134a Refrigerant Identifier

ENSPECO Recovery/ Recycle/ Evacuate/ Recharge

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Additional users operating manual

AUTOMOTIVE REFRIGERANT ANALYZER OPERATION MANUAL. Analyzer Part Number: 68941

SERVICE PROCEDURE FOR RETROFITTED A/C SYSTEMS

GENERAL 2004 HVAC SYSTEMS. Manual HVAC System - Sorento SPECIFICATIONS. Fig. 1: Air Conditioner Specifications Courtesy of KIA MOTORS AMERICA, INC.

Owner s Manual Refrigerated Compressed Air Dryers Model F-100

OPERATING MANUAL. Model 34134Z. Refrigerant Unit Recover, Recycle, and Recharge

High Performance Oilless Residential Light Commercial. Product Leadership Training Service Reliability

OPERATION & MAINTENANCE MANUAL AC880

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

YELLOW JACKET Recovery Machines for every refrigerant, every size system

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

REFRIGERANT SYSTEM SERVICE WARNINGS

Setup and Operation Manual

A/C Refrigerant. Air Conditioning systems use refrigerant to move heat from air inside the car to air outside the car

347002K/177002K/34900

P E R A T I N G A N U A L. Operating Manual for. Model Recovery, Recycling, Recharging Unit

Sanitaire. Owner s Guide. 10 GALLON Box Extractor SC6088 Series IMPORTANT

Operating Manual. Model 34700Z / 17700Z Recovery, Recycling, Recharging Unit

Model Operating Manual for. Recovery, Recycling, Recharging Unit P E R A T I N G A N U A L

RLD-H10P Refrigerant Leak Detector

Ariazone 5001 HFO-1234yf

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Operating Manual. Series 12134B Recovery/Recycling/Recharging Unit for R-12 and R-134a

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

CC Series VACUUM PUMPS

Refrigerant Recovery Unit, Model RRU134

User Manual. Twin Piston Vacuum Pumps: Oil-less WVP Series: WVP12, WVP10, WVP5, WVP4, WVP3, and WVP2

CSD-1 CRN Electra Steam, Inc. Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

Owner s Manual. Terpene Trap CF 1000

English Manual for Jewelry Casting and Investing The professional choice

Operating Manual Manual de Operación Manuel d utilisation

Model Operating Manual for. Recovery, Recycling, Recharging Unit P E R A T I N G A N U A L

Original Instructions Instucciones originales Consignes originales. Model: AC R-1234yf A/C Recover, Recycle, Recharge Machine

5. MVAC-like appliance include appliances using R22 refrigerant a. True b. False

Operating Manual, Model K/348012K Recovery/Recycling/Recharging Unit For R-12 and R-134a Refrigerants...1

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

Operation Manual... 1 Manuel d utilisation Manual de Operación.. 60

Ceiling Mount Air Purification System

HEATING AND AIR CONDITIONING

Rev. E 2013 Pentair Technical Products P/N Distributed by: McLean Parts

Owner s Manual. FMI BRANDS INC Avenue Surrey, B.C. Canada V3Z 3V7 Toll Free Fax Model number FMPPC2F

RLD-H10G Refrigerant Leak Detectors

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL

Installation Instructions

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

MDX. Non-Cycling Refrigerated Compressed Air Dryers with zero-loss Intellidrain. Operation & Maintenance Manual MODELS MDX

Teflon Rotary Drum Pump

MODEL MW200 MODEL MW600 AIR DRYER

Operation & Maintenance Manual MONSOON WET DOWNDRAFT TABLE. Visit our Website for more information on this product.

Operating Manual. Model K/ K Recovery/Recycling/Recharging Unit

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Model No: Little Devil II (inc ss)

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

Whynter Portable Ice Maker 33 lb capacity - White

AC-12200E Portable Air Conditioner

Portable Air Conditioner

Construction Heater GENERAL HAZARD WARNING

English. Your Model Number is: HD1500 IMPORTANT

MODEL 7000 SUCTION UNIT

5) Do not start or stop the unit by inserting or pulling out the power plug.

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

WILKERSON MODELS DE3, DE4 AND DE5 COMPACT HEATLESS AIR DRYERS

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

OPERATING MANUAL MODEL AIR 1500TM AIR DRYER

Quest Power Electric Heat EHS 31 Pro

Quest Power Electric Heat EHS 62 Pro

Transcription:

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual (English)

Table of Contents Page General Safety Instructions...2 System Overview...3 RecoverX-CAR Operation Guide..4, 5 Liquid/Vapor Recovery Diagram..5 RecoverX-CAR Wiring Diagram..5 LED Light Meanings.6 TOS Install Diagram..6 Suction Filter..6 Troubleshooting Guide..7 Technical Data/Specification.7 Important Notice to Purchaser...8 Warranty Information 8 General Safety Instructions 1. Know your equipment. Read and understand the operation manual and the labels affixed to the unit. Learn its applications and limitations, as well as the specific potential hazards of your equipment. 2. CAUTION Should be operated by certified personnel. 3. Use the correct hoses. This equipment is to be used with the included 37827 hose kit, designed for recovery of contaminated R-134a and R-1234YF refrigerant from Motor Vehicle Air Conditioning (MVAC) systems. 4. Use properly marked recovery cylinder. This equipment is to be used with the included 37826 recovery cylinder, which is labeled for use with contaminated refrigerant only. 5. Ground all equipment. Plug the RecoverX-CAR into properly grounded receptacle with an appropriate plug. 6. Do not pressure test with compressed air. Some mixtures of air and refrigerant have been shown to be combustible at elevated pressures. 7. Avoid breathing A/C refrigerant and lubricant vapor or mist. Exposure may irritate eyes, nose and throat. To remove refrigerant from the A/C system, use only equipment certified for the type of refrigerant 2 being removed. Additional health and safety information may be obtained from refrigerant and lubricant manufacturers. 8. Avoid dangerous environments. To keep operator exposure to a minimum, use the RecoverX-CAR with sufficient ventilation. Always perform recovery in wellventilated areas. Use this equipment only in locations with mechanical ventilation, providing at least four air exchanges per hour, or the equipment should be placed 18 above the floor. This equipment should not be used near open containers of gasoline or any other flammable liquid. Do not allow refrigerants to contact open flame. Refrigerant decomposition in flame results in phosgene gas. Breathing phosgene gas can be fatal. 9. Always wear safety goggles and gloves. Personal protective equipment should be worn to protect operator from frostbite. 10. Use caution when connecting or disconnecting. Improper usage may result in refrigerant burns (frostbite). If a major leak occurs, proceed immediately to a wellventilated area. 11. Disconnect recovery machine from power before servicing. An electr i- cal shock hazard is present when the

unit is disassembled. 12. Repair damaged parts. Do not operate the RecoverX-CAR with a defective part. Repair unit to proper operating conditions. 13. Use recommended accessories. Follow the instructions that accompany all accessories. Improper use of accessories may damage equipment or create a hazard. 14. Use the RecoverX-CAR only with the proper refrigerants. (See specifications for a complete list of compatible refrigerants). 15. Operate the RecoverX-CAR within the design parameters. The RecoverX-CAR was designed to operate in a temperature range from 40 F (4 C) to 120 F (49 C). Do not operate in a wet location. 16. CAUTION - Refrigerant may be contaminated with hydrocarbons and leak sealants 17. To minimize sparking potential, it is recommended that electrical equipment startup first by turning on switch, then plug power cord into outlet at least 3 meters away. Locate vacuum pump outside of building. 18. Use an area fan to vent/diffuse any leakage during service Caution: All r efr iger ant hoses, r e- covery tanks, refrigerant lines, the RecoverX-CAR, and other vessels containing refrigerants should be handled as if under high pressure. Tanks containing refrigerant may have damaged valves. Always open valves slowly to prevent release of refrigerant should this be the case. Caution: To avoid potential leakage to the atmosphere, the proper hoses and fittings should be used and checked for damage. Caution: To avoid overfilling the refrigerant cylinder, read and follow the manufacturer recommended filling instructions for the refrigerant being recovered. To prevent the risk of fire, DO NOT use and extension cord smaller than 16 AWG (1.276mm²) and longer than 25 ft (7.6m). System Overview The RecoverX-CAR offers significant flexibility to meet contaminated R-134a and R-1234YF handling needs. Careful handling of these refrigerants is an important part of servicing Motor Vehicle Air Conditioning (MVAC) equipment. Specific regulations apply to refrigerant handling. Familiarize yourself with these regulations. The RecoverX-CAR is used to recover contaminated refrigerant from MVAC systems. The refrigerant is transferred to a holding tank. For field service, this tank is normally a portable refrigerant recovery cylinder. Because the refrigerants are contaminated, they must be reclaimed and are not to be re-used. Use care when recovering refrigerant into a portable tank. As stated in the warnings, overfilling a tank can be extremely dangerous. The best method for monitoring tank level is a scale that continually monitors the weight of the tank. Your RecoverX-CAR has an umbilical cord to connect to the Tank Overfill Switch (TOS) located on your recovery tank. When connected to the recovery cylinder, this switch will automatically turn off the recovery machine when the tank has reached its recommended maximum fill level. The RecoverX-CAR is designed for recovery of both liquid and vapor refrigerant from MVAC systems. During the refrigerant recovery process, there is often system oil that is recovered with the refrigerant. You can determine how much oil was removed from a system by measuring the amount of oil in the Oil Separator Drain. If oil was removed, replace with the appropriate type and amount into the MVAC system. 3

4 RecoverX-CAR Operating Guide Direct Liquid/Vapor Recovery The RecoverX-CAR can recover vapor and liquid contaminated refrigerant. Use your RecoverX-CAR to pull refrigerant directly out of the MVAC system and transfer it into your 37826 recovery cylinder for contaminated refrigerant. MVAC system recovery can be done by connecting to both the low side and high side of the MVAC system using hose assembly 37827. See diagram on the following page. Ensure you have the capacity to recover all of the refrigerant in the system being serviced. In the USA, the recovery cylinders can only be filled to 80% capacity. Follow the steps below and refer to the LED Light Meanings table on page 6: Ensure the RecoverX-CAR unit Power Switch is off ( ) and the MVAC system is not running. Check the Oil Separator Drain and empty the reservoir if there is any oil present. **Note Pull the RecoverX-CAR unit into vacuum before removing the brass cap on the Oil Separator Drain. The Oil Separator Drain is normally under high pressure. Tilt the RecoverX-CAR unit back about 10 degrees to ensure that all of the oil is drained from the reservoir. Reattach the brass cap once the oil has been drained. Oil Separator Drain 3. Plug the RecoverX-CAR into a 110V power supply. 4. Set the ambient pressure override switch as needed for the MVAC system being recovered. If the system has a known leak, turn the override switch off ( ). This will shut off the RecoverX-CAR unit when the suction pressure has reached a pressure slightly above atmospheric pressure (3-5 psig) and will prevent air from being recovered into the recovery cylinder. If the system is not leaking, turn the override switch on This.( ) will allow a full recovery to the desired vacuum level. 5. Connect the recovery unit to the MVAC system as shown in the Refrigerant Recovery diagram on page 5. 6. Connect the Tank Overfill Sensor (TOS) cord as shown in the TOS Install diagram on page 6. 7. Connect the discharge hose between the RecoverX-CAR discharge fitting and the liquid port on the recovery cylinder. Open the liquid valve on the recovery cylinder..( ) 8. Turn the Power Switch on ** Note** Upon power up, the machine fan will run for six seconds before the compressor startup to ventilate its enclosure and to help prevent the buildup of potentially flammable mixtures of gasses. 9. If the ambient pressure override switch is turned on, monitor the lowside pressure until the desired vacuum level is achieved. If the ambient pressure override switch is turned off, the yellow and red lamps will flash alternately when the system has reached 3-5 psig and the compressor will be stopped. 10. Turn the Power Switch off ( ) once the recovery is complete.

10. Wait five (5) minutes to ensure the pressure does not rise above zero. 11. If the pressure rises above the required vacuum level, continue the recovery Steps 8-11. 12. If the pressure remains below the required level, close the valve on the recovery tank. 13. Disconnect the hoses from the MVAC system and the recovery cylinder. **Note** Ensure that all valves are closed. 14. Because oil can be removed from the MVAC system during recovery, the Oil port should be drained after every usage. Drain this oil into the included oil fill bottle to determine how much refrigerant oil was removed from the MVAC system. 15. If oil was removed, replace with the appropriate type and amount into the MVAC system. LIQUID OR VAPOR RECOVERY DIAGRAM WIRING DIAGRAM 5

LED LIGHT MEANINGS Green Light Flashing Solid Green Light Solid Yellow Light Alternating Red and Yellow Lights Solid Red Light System startup ventilation. System Recovering System loss in airflow detected or recovery tank full. Check system fan and tank weight. Atmospheric recovery complete. High pressure cutout reached. TOS INSTALL DIAGRAM Umbilical Mounted to Tank Umbilical with Shorting Cap SUCTION FILTER The RecoverX-CAR is equipped with a built-in particulate strainer located behind the suction port. Unscrew the suction port by using a 11/16 wrench to unscrew the hex head port to remove. This prevents contaminants, copper shavings, carbon, and other foreign objects from making their way to the RecoverX-CAR compressor and causing permanent damage. Like a filter drier, this strainer MUST be cleaned or replaced often. Failure to do this can cause the strainer to become too clogged for refrigerant to flow freely. A sure sign that the straining device is clogged is the freezing of the suction port and the filter cover. Before replacing, check the condition of the o-ring. Replace if necessary. Note: Make sure to use a strainer in the RecoverX-CAR for every job! Filter strainers and o-rings are available from your supplier. Filter Strainer and O-Ring - Part #95457 6

TROUBLESHOOTING GUIDE Condition Possible Problem Possible Solution No power to unit Power cord not plugged in Plug in power cord Outlet not energized Reset outlet breaker Compressor will not start Compressor thermal overload is tripped Allow compressor to cool down until thermal overload resets ATM Recovery switch is tripped (yellow and red alternating lights) Atmospheric recovery is complete, re-pressurize the suction side to Unit trips breaker upon start up Unit runs but does not recover refrigerant Unit will not pull a vacuum TECHNICAL DATA Unit has not completed cabinet ventilation (flashing green light) Unit is shut down on tank full or loss of airflow (solid yellow light) Unit is shut down on high pressure (solid red light) Compressor is in a locked-rotor condition Suction filter clogged Restriction in suction hose set or system ATM recovery switch is tripped Leak in MVAC system above 20 psi to reset switch The RecoverX-CAR internal fan will run for approximately 6 seconds before the compressor starts up to clear any potentially flammable gasses from building up inside cabinet Check shorting cap or TOS connection to tank, if connections are good, there may be a problem with the airflow sensor or unit fan Check discharge pressure gauge, unit will trip around 500 psi discharge, check for restrictions including closed valves Contact customer service for repair Contact customer service for repair Check coupler connections, make sure the couplers are fully engaged on the service ports and the knobs on the couplers are turned clockwise until they stop Use the ATM Recovery Override switch to bypass the ATM Recovery switch if it is desired to pull the system into a vacuum Locate and repair and leak(s) in the system Compressor: ½ HP Reciprocating Oil-Less Twin Cylinder Power Source: Size: Height: 115V AC 50/60 Hz 1 Phase 12.50 Width: 12.50 Depth: 19.25 Weight: 29.9 lb Approved Refrigerants: Contaminated R-134a & R-1234YF Certifications: SAE J2851 & UL 1963 7

IMPORTANT NOTICE TO PURCHASER Check for damage immediately. Prior to shipment, all YELLOW JACKET RecoverX-CAR Refrigerant Recovery Systems are completely tested and inspected to assure compliance with Ritchie Engineering factory specifications. If the recovery system carton is damaged, check contents immediately. Note damage on shipper s Bill of Lading and have shipper sign statement. Notify carrier immediately of the damage to arrange inspection of the recovery system and packaging. The CARRIER ALONE is responsible for handling and settling your claim. Ritchie Engineering will cooperate in assessing damage if the recovery system is returned to the factory prepaid. WARRANTY INFORMATION Carton contents include: RecoverX-CAR Contaminated Automotive Recovery Machine Warranty Registration Card 37826 Contaminated Refrigerant Recovery Cylinder with TOS 37827 Hose Kit with R-134a & R-1234YF Couplings Oil Fill Bottle (for Measurement of Recovered System Oil) To validate warranty, mail registration card within 10 days. Ritchie Engineering guarantees YELLOW JACKET products to be free of defective material and workmanship which could affect the life of the product when used for the purpose for which it was designed. Warranty does not cover items that have been altered, abused or returned solely in need of field service maintenance. The RecoverX-CAR Contaminated Automotive Recovery Machine (UPC 37825) is covered by a one year warranty for parts and labor. The following exceptions will not be covered under this warranty: Recovery products that have been altered, misused, or improperly maintained. The following must be done before returning unit: 1) Call our technical service personnel at (800) 769-8370 to assess if the problem can be resolved over the phone. 2) Obtain an RGA number from Ritchie Engineering for the return of the product. 3) Fax a copy of the original invoice to (800) 322-8684. If at any time after the warranty period you have problems with your YELLOW JACKET recovery unit, call our technical service department for help in selecting the correct replacement parts, or to arrange for its repair at reasonable costs. YELLOW JACKET Products Division Ritchie Engineering Co., Inc. 10950 Hampshire Avenue South Bloomington, MN 55438 e-mail: custserv@yellowjacket.com Web Site: www.yellowjacket.com Phone: 800-769-8370 Int l Phone: 952-943-1333 Fax: 800-322-8684 Int l Fax: 952-943-1605 European Division: Ritchie Engineering Co., Inc. Unit 10 Riverview Business Park Friarton Road Perth PH28DF United Kingdom + 44 1738 459020 e-mail: info@fairfieldtchonologies.co.uk 8