ACTIVE INFRARED BARRIER

Similar documents
MANUFACTURER OF PERIMETER INTRUSION DETECTION SYSTEMS FOR CRITICAL INFRASTRUCTURE AND SENSITIVE SITES

Video Surveillance Systems Infrastructure

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Section PERIMETER SECURITY SYSTEMS

PARVIS Safe and tranquil thanks to Parvis

Installation Manual. ATS Remote Annunciator Catalog 5350 DANGER WARNING D

THX-DL Data Logger USER & INSTALLATION MANUAL V

Product Specifications

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

Appendix 1 LACCD Districtwide Security Performance Requirements

SECTION Process and Immersion Turbidity and Total Suspended Solids Sensor

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

English. Series. Installation and Use Manual

SECTION Fluorescent Dissolved Oxygen Measuring System

Alarm module for leak detection with webserver

EC-BOS-602/616 AX Security

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Access CONTROL. MANAGEMENT Software

Architectural and Engineering Specification for a. Flash / Flare

[Project Location] SECTION FUSION STAINLESS STEEL DOME HOUSING MOOG VIDEOLARM A&E SPECIFICATION SSDP SERIES

PRO-WATCH NOTIFIER SECONDARY FIRE INTERFACE ARCHITECT AND ENGINEERING SPECIFICATION

WebAlert WA500 Series Process Monitor Instruction Manual

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

OJD ITB No Attachment E Duress Alarm Equipment Specifications

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Architectural and Engineering Specification for a Real-Time Locating System Flare

ARCHITECTURAL SPECIFICATIONS

Installation, Configuration and User Manual

Installation And commissioning manual. Series S Double Beam 1/16

Smart Wireless Sensor

ModBus DE-1 INSTALLATION AND USER MANUAL

Panel Mounted Fault Annunciator Series

REMOTE MONITORING AND ALARM SYSTEM

SECTION DIGITAL-NETWORKING LIGHTING CONTROLS ENLIGHTED LIGHT MANAGEMENT SYSTEM

7638 Standish Place Derwood, MD Tel: (301) Fax: (301) Page 1 of 12. Website:

SECTION Free/Available Chlorine Analysis System

Smart Wireless Sensor

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

UNICA - ALARM SYSTEM WITH VISUAL VERIFICATION. All in One - All in Touch Video - Alarm System

YOUR PARTNER IN FIRE & GAS DETECTION

Refrigerated Incubator Model and Operating Instructions

Diagnostics and Monitoring System WEB Tool 2. User Manual

IntesisBox BACnet/IP Server - Notifier ID3000 series

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

C. The system shall be capable of turning luminaires on/off (where supported by the luminaire) as well as full range dimming.

PowerLogic ION Setup Meter Configuration Software Configuration Guide

CAREL heatersteam Electric Element Steam Humidifiers

Universal fault annunciator for panel mounting

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

User manual for CPR32-NET network controller

SCR100 User Manual. Version:1.1 Date:Dec 2009

Product Data Sheet. Remote Terminals. Features:

Dew point set DS 400

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

perimeter barriers Active infrared SAFET Y INSIDE AND OUTSIDE THE HOME WALL-FLUSH INTERNAL OR EXTERNAL PROTECTION EXTERNAL PROTECTION

CARD ACCESS CONTROL SYSTEM

Security designed for your lifestyle

ThermoControl 0 C - 10 C - 20 C - 30 C

SEC 2000 Millenium Infrared Gas Detector

Advanced Power Monitor (APM)

SL-3 Vibration Sensor line A&E Specifications Page 1 of 12 SL-3 AE v doc

Hugs Product Guide Specification

IndigoVision Alarm Panel. User Guide

SECTION Power over Ethernet (PoE) Enabled Camera Housing Moog Videolarm SM5, ACH13, FDW75

Product Specification

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

EcoAisle Thermal Containment System

GasGard 100 Control System

Guide Specifications. HyperPod System PART 1 - GENERAL 1.01 SUMMARY

Knürr RMS Compact II. Knürr RMS Compact II 2.81

Ethernet General Purpose

Architectural and Engineering Specification for a Hybrid Perimeter Intrusion Detection and Intelligent Lighting System.

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V

INTREPID SINGLE-PLATFORM PERIMETER INTRUSION DETECTION AND MONITORING SYSTEM

Measuring Recording Online Monitoring Regulation Alarming

DATAssure. Laboratory wireless alarm & monitoring system

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

Photoelectric Beam Detector

Intrusion. Outdoor protection perimeter

HikCentral Web Client. User Manual

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1100X

RVRC Training Manual Fast Trace Installer Menu

Architectural and Engineering Specification for a Fiber Optic Perimeter Intrusion Detection System. FiberPatrol FP1150

Presented By. BEI Security

Data Center. Cold Storage

Universal Monitoring System. Model IMEC8A. User Manual Version 1.10 Software version 2.3.1

User manual. KNXgal. version

Clino Guard. Intelligent Life Care. Solutions for safe and efficient care

EnergyMaster. ENEC Monitoring System. An on-site supervision and remote monitoring solution

products and services

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Ion Gateway Cellular Gateway and Wireless Sensors

Solution F2. Fire Alarm Control Panels one step ahead.

The EN54 Part 2, 4 and 13 Fire System

Transcription:

Although PROTECH provides high security indoor intrusion sensors for the military and government markets, our specialty is outdoor protection. Since we first introduced our PIRAMID outdoor dual technology sensor in 1993, we have been constantly improving and perfecting the adaptability to cope with the ever-changing outdoor environment. Our proprietary "Stereo Doppler" technology makes this possible and gives our sensors the ability to provide the highest level of security with the very lowest nuisance alarm rate possible. For additional information, contact: PROTECH/Protection Technologies, Inc. 529 Vista Blvd. Sparks, NV 89434 Phone: +1 775 856-7333 Fax: +1 775 856-7658 sales@protechusa.com www.protechusa.com DIVISION 28 ELECTRONIC SAFETY AND SECURITY MasterFormat 2014: 28 16 43 Perimeter Security Systems MasterFormat 2016 28 31 21.17 Fixed Optical Beam Area and Perimeter Security Systems Notes to Specifier: 1. Where several alternative parameters or specifications exist, or where, the specifier has the option of inserting text, such choices are presented in <bold text>, where the parameter specified in [brackets] is the normal default. 2. Explanatory notes and comments are presented in colored text. July, 2016 Page 1 of 10

Important Note to Security Systems Specifiers CSI MasterFormat 2016 incorporates numerous significant changes affecting electronic safety and security. This document is written to provide flexibility in using either format, although adoption of MasterFormat 2016 is encouraged. The following is a guide to the MasterFormat numbers relevant to the product referenced in this specification. Primary Specification Area: MasterFormat 2014: 28 10 00 Electronic Access Control and Intrusion Detection 28 16 00 Intrusion Detection 28 16 43 Perimeter Security Systems MasterFormat 2016: 28 30 00 Security Detection, Alarm, and Monitoring 28 15 00 Access Control Hardware Devices 28 31 21 Area and Perimeter Intrusion 28 31 21.17 Fixed Optical Beam Area and Perimeter Security Systems Related Requirements: MasterFormat 2014: 28 13 33.26 Access Control Interfaces to Intrusion Detection 28 16 29 Intrusion Detection Remote Devices and Sensors 28 16 33 Intrusion Detection Interfaces MasterFormat 2016 28 05 35 Security Data Communications Wireless Transmission Equipment 28 16 13 Access Control Interfaces to Intrusion Detection 28 31 21.23 Fixed Optical Beam Area and Perimeter Security Systems 28 31 31 Intrusion Detection Interfaces 28 47 21.15 Notification Interfaces to Security Detection, Alarm and Monitoring 28 51 51.15 Information Interfaces to Security Detection, Alarm and Monitoring July, 2016 Page 2 of 10

PART 1 GENERAL 1.01 SUMMARY A. Section includes an active infrared barrier system. B. Product - A system consisting of sensing columns which create an infrared intrusion barrier and report to a head-end hub via RS-485 transmission. Refer to MasterFormat notes at the beginning of this document to select requirements specific to the MasterFormat version being used. 1.02 REFERENCES A. Definitions 1. ModBus A serial master-slave communications protocol initially published in 1979 for use with programmable logic controllers. 2. Single face Infrared beam transmission or reception, or both, from one surface (face) of a sensing column. 3. Double face Infrared beam transmission or reception, or both, from opposing surfaces (faces) of a sensing column. 4. Cell A mono directional Infrared transmitter-receiver device installed in a column. A pair of cells, installed in 2 different column, will create an Infrared detection beam between these columns. B. Reference Standards 1. Electromagnetic compatibility a. EU EMC Directives EN 55022, EN 55024 a. FCC-47 CFR Part 15, Class B 2. IEEE 802.3 Ethernet 3. Environmental 1.03 SUBMITTALS a. ANSI/ IEC60529 - Degrees of Protection Provided by Enclosures b. International Electrotechnical Commission (IEC) - Ingress Protection Rating IP55 A. Product Data 1. Manufacturer s printed or electronic data sheets 2. Manufacturer s installation and operation manuals B. Shop Drawings 1. Termination points and enclosures 1.04 QUALIFICATIONS A. Manufacturer of system shall have a minimum of five (5) years experience in the design, manufacture, and successful implementation of perimeter sensing systems. July, 2016 Page 3 of 10

1.05 DELIVERY, STORAGE, AND HANDLING A. Deliver the equipment system in the manufacturer s original, unopened, undamaged container with identification labels intact. 1.06 WARRANTY 1. Ship and store the system protected from mechanical and environmental conditions as designated by the manufacturer and in a temperature environment of -40 F to +158 F (-40 C to +70 C) A. The Manufacturer shall provide a limited warranty for the system to be free of defects in workmanship and material under normal operating conditions for a period of one year from the date of product shipment. - END OF SECTION July, 2016 Page 4 of 10

PART 2 PRODUCT 2.01 EQUIPMENT A. Manufacturer: PROTECH/Protection Technologies, Inc. 529 Vista Blvd. Sparks, NV 89434 Phone: +1 775 856-7333 Fax: +1 775 856-7658 sales@protechusa.com www.protechusa.com B. Model: 3000, 3100 C. Alternates: None 2.02 GENERAL DESCRIPTION A. The system shall detect all attempts at intrusion by using adjustable infrared barriers formed by two or more externally powered sensing columns, each of which communicates alarm information to a head-end alarm processing hub via RS-485 communications. B. Intrusion detection shall be based upon the interruption of pulsed infrared beams between sensing columns. 1. Sensing columns shall be configurable for height and number of infrared beams. a. Beams shall be multiplexed and optically synchronized. 2. Sensing columns shall be available for infrared beam operation in both single face and double face operation. 3. Sensing columns shall be available configured as infrared transmitters, infrared receivers, or both. 4. The system shall have selectable detection/triggering modes. 5. The response time for an intrusion alarm shall be selectable from 40 ms to 500 ms. C. The system shall operate with sensing columns spaced up to 100 m (328 feet) outdoors or 500 m (1640 feet) indoors. D. Each sensing column shall have an integrated anti-climbing cap. E. Each sensing column shall have integrated alignment tools. F. The sensing column shall be capable of in-line, corner, floor, or wall mounting. 2.03 SYSTEM COMPONENTS A. Sensing Column 1. Number of beam directions (faces): 1 or 2 2. Number of beams per direction: 8 36 available 3. Beam Wavelength: 950 nm 4. Zoning: a. Number of intrusion zones: Up to 3 b. Cells per sensing column: 5-10 5. Beams shall have the ability to be selectively deactivated or activated. 6. Power: 110 VAC/230 VAC July, 2016 Page 5 of 10

7. Physical a. Column height: <1.1 m 3.8 m (3.6 ft. 12.5 ft.)> <1.0 m 3.0 m (3.3 ft. 12.5 ft.)> Protech Beam and Direction Information: Model Height Faces # Directions # Beams per Direction 3000 1.1 m (3.6 ft.) 1 1 8 1.9 m (6.2 ft.) 1 1 18 2.5 m (8.2 ft.) 1 1 24 3 m (9.8 ft.) 1 1 32 3.8 m (12.5 ft.) 1 1 36 1.9 m (6.2 ft.) 1 2 8 2.5 m (8.2 ft.) 1 2 12 3 m (9.8 ft.) 1 2 14 3.8 m (12.5 ft.) 1 2 18 3100 1 m (3.3 ft.) 1 1 6 2 m (6.6 ft.) 1 1 20 2.5 m (8.2 ft.) 1 1 24 3 m (9.8 ft.) 1 1 32 2 m (6.6 ft.) 1 2 10 2.5 m (8.2 ft.) 1 2 12 3 m (9.8 ft.) 1 2 14 1 m (3.3 ft.) 2 2 6 2 m (6.6 ft.) 2 2 20 2.5 m (8.2 ft.) 2 2 24 3 m (9.8 ft.) 2 2 32 b. Environmental 8. Alarms 1) Columns shall be IP55 rated. 2) Each column shall have a heater set to activate at 71.6 o F (22 o C) a. Intrusion alarms 1) Detection shall normally require the interruption of 1-3 beams. 2) Detection shall be configurable to also permit detection based on the interruption of only the bottom beam. 3) The system shall provide for independent management of the bottom or other beams. July, 2016 Page 6 of 10

b. The following types of local alarms shall be capable of being generated by the sensing column: 1) Intrusion by zone 2) Disqualification 3) Tamper 4) Anti-climbing cap 5) Auxiliary Input 6) AC Power failure 7) 12 VDC Interface failure 9. Integrated alignment tools shall indicate the quality of the incoming signal and include all of the following: a. optical sight b. LED s c. audible buzzer 10. Settings a. Response time - Intrusion alarm response time settings shall be selectable via potentiometer between 40 and 500 milliseconds. b. Web Interface B. Head-End Hub 1) A column s settings shall be accessible via web browser by direct connection of a PC via Ethernet a) Web browser: Internet Explorer, version 7 or higher; Google Chrome, Mozilla Firefox b) The following settings shall be available: i. network address ii. ModBus TCP RS-485 iii. passwords iv. clock v. zone names and settings vi. inputs and outputs vii. assignment of relay outputs viii. alarm settings ix. beam deactivation x. synchronization of columns xi. Detection mode c) The web interface shall allow for visualization of barrier status 1. A head-end hub shall centralize all system alarm information from the sensing columns and from other sensing systems provided by the Manufacturer. 2. The head-end hub shall be based upon a Linux operating system. 3. The head-end hub shall provide for automatic configuration of the sensing network, including detection of the sensors connected to the network and number of available contacts. July, 2016 Page 7 of 10

4. The head-end hub shall provide diagnostic information for each sensor. The Maxibus 3000 head-end hub provides processing capability for the following SORHEA/Protech systems through its 4 COM ports: Solaris up to 24 radio boards (1 per sensing column) and 64 control boards (1 per 5TX and 1 per 5RX beams) per COM port RX Columns up to 32 per COM port Apiris Columns - up to 32 per COM port G-Fence control units up to 16 per COM port 5. Events The head-end hub shall provide a detailed event log, including alarms, accessible through a web server, for up to 1000 events. a. For each event, the log shall maintain the following data: 1) event timing to include date, hour, minute, and second 2) specific column triggered during an event, and type of event (e.g., intrusion, anticlimbing, tamper) 6. Communications a. RS-485 - The head-end hub ( hub ) shall connect to sensing columns and any system radio coordinator units via ModBus protocol over an RS-485 connection. a) number of RS-485 COM ports: 4 b. Ethernet The hub shall connect to an Ethernet network using an RJ45 connection. c. Alarm outputs The hub shall be capable of providing alarm information via any of the following: 1) dry contact outputs 2) ModBus over RS-485, with hub functioning in Master or Slave mode 3) ModBus over Ethernet, with hub functioning as Server or Client The hub has 8 on-board relay contacts and provision for up to 16 additional relay extension cards, each of which provides 8 additional relays. 7. Events The head-end hub shall provide a detailed event log, including alarms, accessible through a web server, for up to 1000 events. a. For each event, the log shall maintain the following data: 8. Settings 1) event timing to include date, hour, minute, and second 2) specific column triggered during an intrusion event and type of event a. The head-end hub shall maintain the following settings in its memory: 1) relay assignments 2) site configuration 3) its own hub settings July, 2016 Page 8 of 10

b. The hub shall have the capability of exporting its settings to a file and restoring settings from a saved file. 9. Web Server - The head-end hub shall have an integrated web server to support configuration and maintenance. a. The web server shall be capable of 1) assigning an administrator and securing access through login ID and password 2) setting the real time clock in the hub 3) mapping one or more alarms to one or more relay contact outputs 4) setting Ethernet network parameters 5) configuring the COM ports for the sensing network(s) 6) displaying a log of events 7) displaying relay assignments b. The web server interface shall be available in English, Spanish, or French. c. The web server shall be accessed via any web standard browser 10. Electrical - Voltage a. 10.5-14 VDC @ 230 ma b. Optional 110/230 VAC to 13.6 VDC/2.2 A power supply with battery back-up 11. Operating temperature: 32 F to +131 F (0 o C to +55 o C) C. Configuration and Maintenance Software 1. Configuration and Maintenance software ( software ) shall be available as a PC-based graphical tool intended for configuration and basic monitoring of the system 2. Functions 2.04 COMMUNICATIONS a. Viewing sensing node (column) status b. Import a site layout in image file format c. Display all system components on a map d. Display the location of an intrusion alarm on a map e. Display a current event log A. Sensing column to hub: RS-485, 2 wire, ModBus TCP protocol B. Sensing column to PC: Ethernet 10/100 via Ethernet switch or cross-over cable - END OF SECTION - July, 2016 Page 9 of 10

PART 3 EXECUTION 3.01 INSTALLERS A. The Contractor s installers and technicians shall be factory trained and certified to install, service, and maintain the system. B. Contractor personnel shall comply with all applicable state and local licensing requirements. 3.02 PREPARATION A. Contractor shall insure that all products to be installed have been verified to possess the latest version of available firmware. 3.03 INSTALLATION A. The Contractor shall adhere to all Manufacturer s published installation procedures, diagrams, and guidance. B. Sensing Columns 1. All vegetation shall be cleared from the sight path between adjacent sensing columns. - END OF SECTION - July, 2016 Page 10 of 10