TECHNICAL INFORMATION Physical Developer Catalog Nos. LPD100, LPD101

Similar documents
TECHNICAL INFORMATION Cyanoacrylate Fuming Chamber Catalog Nos. FR200, FR200220

TECHNICAL INFORMATION Cyanoacrylate Fuming Chamber Catalog No. FR600, FR600220

Laboratory Techniques

Safety In Chemistry. Identified Risks and Hazards

Laboratory Glassware Cleaning and Storage

Instructions for Coating Fimbel Garage Door Panels

Test Tube Rack. Test Tube

TECHNICAL INFORMATION CYANOVAC Vacuum Chamber Operation Catalog Nos. VAC150, VAC250, VAC350

Laboratory Techniques

1. Conduct yourself in a responsible manner at all times in the laboratory.

STUDENT SAFETY RULES

Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated. Beaker

Solids, Total Filterable (Total Dissolved)

Student Lab Procedures. Lab Safety Orientation

Electric Circuits in Household Appliances

Ductless Forensic Containment Products

2. What are the advantages and disadvantages of plant tissue culture?

PDS 2010 Parylene Coater SOP

CHM 130LL: Lab Safety Name: Answer Key _ Section:

Ductless Fume Hoods, Chambers & Drying Cabinets

State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR EVALUATING CLEANNESS OF COARSE AGGREGATE

CPAP Washbasin Manual

Laboratory Techniques

Lab Safety and Equipment

State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR EVALUATING CLEANNESS OF COARSE AGGREGATE

Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated. Beaker

Ductless Forensic Containment Products

Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated. Beaker

Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated. Beaker

Ductless Fume Hoods, Chambers & Drying Cabinets

Arizona State University NanoFab PARYLENE COATER. Rev D

Effects of Wind on Plant Size

Beaker Beakers hold solids or liquids that will not release gases when reacted or are unlikely to splatter if stirred or heated. Beakers are NOT accur

1. Conduct yourself in a responsible manner at all times in the laboratory.

Familiarize yourself with the following:

Laboratory Equipment. Use of equipment

For routine maintenance of polished granite installations with a cleaner and protector:

UNSIGNED HARDCOPY NOT CONTROLLED

HOSTA MULTIPLICATION KIT

FlaskScrubber & SteamScrubber. Laboratory Glassware Washers NEW! FlaskScrubber & SteamScrubber racks now interchangeable

ISO INTERNATIONAL STANDARD. Textiles Method for assessing appearance of apparel and other textile end products after domestic washing and drying

HydroFlux Welder Torch System T0-102 / T0-103

DZ5080 US Index01 19/09/07 10:50 Page 2

Mixing Training Course P/N Rev. D

Simple Chemical Tests of Potting Mixes Used For Container Crops

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

Lab Safety. Section 2L. Chemistry I & II

SKLAR COATED SURGICAL INSTRUMENTS RECOMMENDED CARE & CLEANING INSTRUCTIONS

FOR LATENT FINGERMARK DEVELOPMENT FORENSIC TECHNOLOGY

REGULAR MAINTENANCE AND CARE

1. Table of Contents VisiJet Materials Overview Disclaimer Ispropyl Alcohol (IPA) and Polypropylene Glycol

STONETECH Maintenance & Care Porcelain, Ceramic & Quarry Tile with Cement Grout

DIRT! APES Laboratory Activity

FERN MULTIPLICATION KIT

Applicable TAKS objectives: ELA Objectives 4, 5, 6; Science Objective 1

D Dissolution Units Mixing Training Course P/N Rev. C

Fingerprint Development Chamber 34

DEPARTMENTAL SAFETY ISSUES - SAFETY TECHNOLOGIST / INFECTION CONTROL PRACTITIONER

Soil ph. Evaluation copy

PDMS Casting Station Supplies

CF SERIES CF100 CF200 CF300

Introduction. Sharps. Working Safely with Sharps at UAB (OHS_HS255) Objectives. Defined

Laboratory Equipment. Section 1L. Chemistry I & II

Cavitator Ultrasonic Cleaner Instruction Manual

Instructions for Coating Cellular PVC Solid Color (brushing and spraying)

The Alfa Laval. Cleaning procedures. for. HeatExchangers.

Major Hazards in Laboratory

Innovative Lighting R-Series Overhead LED Conversion Kits

Automatic Cyanoacrylate Fuming Chamber 24 33T 60T 72XL. Safely Detect Quality Latent Prints and Reproducible Results

SUNBEAM IRON. User Guide SR6300 SR6400. SR6300 Sunbeam Sprint Iron SR6400 Sunbeam Aerostream Iron

Muskogee Public Schools Custodial Procedures for Floor Care

Effective Date: 0 8 / 1 0 / 1 7. Replaces: 08/11/16. Formulated:1997 SPECIAL (MEDICAL) WASTE MANAGEMENT

EDICT ± OF GOVERNMENT

Assembly of a Microbial Fuel Cell

Labels for PET - Wash Water Evaluation

CLEANING. Application Recommendations. Application/ Concerns. Articles Cleaned/ Soil Removed. Recommended Detergent. Cleaning Method.

Radioactive In Situ Hybridization Protocol (HBMI Core University of Rochester Medical Center)

Laboratory SAFETY RULES

DRAFT KENYA STANDARD. Scouring compounds for utensil cleaning Specification Part 2: Dishwashing bar

The PTB Cleaning Procedure for Silicon Spheres

Safety Lab Goggles are required! Apron is optional!

BLAZE ORIGINAL INSTRUCTIONS MANUAL

IRUV CUT COAT Notes for Application

Department of Civil and Environmental Engineering University of Waterloo

Fisher Scientific Isotemp Muffle Furnace 550 Series. Instruction Manual

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate

Proposed ASTM Standard Method

Cavitator Ultrasonic Cleaners

Revised: January 8, Goal: Deposit, expose, and develop standard positive photoresist films as an etch mask, liftoff mask, or sacrificial layer.

Innovative Lighting R-Series Vertical Refrigeration

Tierset Case. Assembled Chocolate Fountain. Auger & Stabilizer. Auger. Crown. Cylinder. Cylinder. D A Crown. Stabilizer. Basin Case. Bowl.

Amerimade RCA Wet Bench SOP Page 1 of 13 Rev /22/2014

Plant-A-Plant Carbon Dioxide Laboratory guide

Innovative Lighting R-Series Horizontal Case Canopy LED Conversion Kits

Corning Storage Bottles Selection and Use Guide

Preserve and Process evidence while protecting the operator and environment.

Heat can change into other forms of energy and vice versa. Heat is measured in the unit of energy, the joule (J).

European PET Bottle Platform

Science Lab Equipment

READ AND SAVE THESE INSTRUCTIONS DE-SCALING SOLUTION. Humidifier De-scaling Solution and Neutralizer. Usage Instructions

Transcription:

SIRCHIE Products Vehicles Training Copyright 2015 by SIRCHIE All Rights Reserved. TECHNICAL INFORMATION Physical Developer Catalog Nos. LPD100, LPD101 Background and Purpose Physical Developer is a silver-based aqueous reagent that reacts with components of sebaceous oils to form a silver/gray deposit. It should not be used as a primary method of latent print development; rather, it is used as a follow up to processing with DFO and/ or Ninhydrin. Since it reacts with sebaceous compounds, it is often likely that additional prints or detail will develop that were not discovered when using other processes that react with amino acids. The effectiveness depends on close observation of impression development, background development and the conditions of the processing solutions. Items and Surfaces The process is effective on porous and semi-porous surfaces such as paper currency, paper, cardboard, raw wood, tissue paper, paper based adhesive tapes and some man-made fibers. It can be used on surfaces that are wet, or have been wetted and subsequently dried. 100 HUNTER PLACE, YOUNGSVILLE, NC 27596 USA Ph: (919) 554-2244, (800) 356-7311 Fax: (919) 554-2266, (800) 899-8181 Web: www.sirchie.com Email: sirchieinfo@sirchie.com 1 of 8

Health / Safety Notice: The products identified in this Technical Information Sheet should not be use without thoroughly reviewing each product s Safety Data Sheet which can be found at www.sirchie.com/support. Physical Developer can be used safety and effectively when used in a controlled environment and in adherence with standard laboratory safety guidelines. Warning: Silver nitrate and the solutions containing this chemical can irritate eyes, mucus membranes and skin. Prepare and use in well-ventilated areas and preferably in the confines of a fuming hood. Use chemical resistant gloves and safety glasses when handling chemical products. Suggested Equipment Forceps / Tongs: Used to move items during processing Smooth and non-metallic Should not have serrated or sharp edges or ridges Fuming Hood (Vented or ductless): The safe and effective preparation of Physical Developer Solutions and processing solutions requires the use of a fuming hood (vented or ductless). Sirchie s AirSafe Basic and Advanced Forensic Workstations (Sirchie Catalog AC600 series) are specially designed to meet and exceed applicable OSHA and ANSI standards for ductless enclosures. Glass Beakers: Used to mix processing formulas 1000/2000 ml graduated laboratory grade beakers Must be thoroughly cleaned before use Glass Processing Dish: The glass processing dish must: Be scratch free Be large enough to process the item without folding (i.e., Pyrex type 15 l x 10 w x 2 d) Must be thoroughly cleaned before use Magnetic stirrer, magnetic follower and magnetic retriever 2 of 8

Bench Rocker (Sirchie BR110) Shatter proof dark containers 1 liter: Used to store unused solutions. Maleic Acid Solutions Special Consideration: Safety and effectiveness issues apply requiring the use of proper protective clothing and preparation of the solutions in a well-ventilated area and preferably in the confines of a fuming hood The Maleic Acid Solution, if indicated, is used prior to Physical Developer processing as a pre-treatment to neutralize alkaline binders and fillers which may react strongly with the Physical Developer process. Maleic Acid Solution using Sirchie Catalog No. LPD110L This 1000 ml pre-mixed Maleic Acid Solution is ready for immediate use in accordance with the directions set forth in the Procession Section. Store in bottle supplied Shelf Life: 18 months Maleic Acid Solution using Sirchie Catalog No. LPD110 (50 grams) Formulation: Place 500 ml of distilled water in a clean 1000 ml glass beaker with a magnetic follower. Add 25 grams of maleic acid to the distilled water and stir to ensure the solution is thoroughly mixed. The solution should be colorless. Transfer the solution to a dark, shatter-proof container and properly label. Unused maleic acid solution may be stored at room temperature for 18 months. Physical Developer Solution Sirchie supplies Physical Developer in two-part, pre-mixed containers. Container A contains the silver nitrate solution and container B contains the redox/detergent solution. Mixing instructions will be set forth in the Processing Section. 3 of 8

Physical Developer Processing Physical Developer is a complex chemical process that may involve exposing the item or surface to three to four separate solutions in sequence. The processor should process a self-made test print concurrently with the items of interest. Sirchie s Latent Print Standards Pad, Catalog No. LPSP200, contains components which included sebaceous oils and salts and will provide a true standard test print. Note: The distilled water and all solutions used in the Physical Developer process must be between 17º C and 23º C (62.5º F and 73.4º F). All glassware and magnetic stirrers used in the process must be cleaned thoroughly. Wipe all internal surfaces of beakers with paper towels under cold tap water and rinse with distilled water before use. Step #1. Distilled Water Pre-Treatment Wash The distilled water pre-wash is used to remove previously applied chemicals (DFO / Ninhydrin) or dirt that may be on the item or surface. If the item has not been previously processed and/or the item is not contaminated this step may be omitted. Place the item to be processed and the test print in a thoroughly cleaned, scratch free, glass processing dish large enough to accommodate the item without folding. Add sufficient distilled water to ensure that the item is completely submerged. Gently rock the solution back and forth across the item during this process for 5-10 minutes. Optional: Use the Bench Rocker (Sirchie BR110) to rock the pan. Care must be exercised to avoid overlapping or unnecessary creasing of the item and non-metallic forceps or tongs without serrated edges should be used to handle and transfer item(s) from the dishes. Step #2. Maleic Acid Pre-Treatment The Maleic Acid pre-treatment is used to neutralize papers containing alkaline binders and fillers. This pre-treatment may be omitted for fragile papers such as tissue and porous surfaces such as wood. Placed the item to be processed and the test print in a thoroughly cleaned, scratch free, glass processing dish large enough to accommodate the item without folding. Add sufficient amount of Maleic Acid Solution to ensure that the item is completely submerged. 4 of 8

Gently rock the solution back and forth across the item during this process for 5-10 minutes or until bubble evolution from the item ceases, whichever is the longer. Option: Use Bench Rocker. Care must be exercised to avoid overlapping or unnecessary creasing of the item and non-metallic forceps or tongs without serrated edges should be used to handle and transfer item(s) from the dishes. Step #3. Physical Developer Working Solution Sirchie s two-part (solution A and solution B ), pre-mixed Physical Developer Solution should not be combined until immediately prior to use and then only in the amount needed to ensure the item in the dish is completely submerged. Pour the selected amount of each solution in to a clean glass beaker stirring with a clean glass or plastic rod for one minute. The Physical Developer Working Solution has a 5 day shelf-life, provided it is stored at room temperature and in a dark container. Solution A Solution B 5 ml 90 ml 20 ml 360 ml 50 ml 900 ml Processing: Place the item to be processed and the test print in a thoroughly cleaned, scratch free, glass processing dish large enough to accommodate the item without folding. Add sufficient amount of the mixed Physical Developer Solution to ensure that the item is completely submerged. Gently rock the solution back and forth across the item during this process for 10 minutes, periodically inspecting the item(s) to prevent overdevelopment of the impression. Option: Use Bench Rocker. Care must be exercised to avoid overlapping or unnecessary creasing of the item and non-metallic forceps or tongs without serrated edges should be used to handle and transfer item(s) from the dishes. Replace the mixed solution as necessary. Discard if the solution becomes badly contaminated with debris or if dark gray/ silver particles are observed at the bottom of the dish or are floating on the surface of the Physical Developer Solution. 5 of 8

Development Grey colored impressions will appear which gradually darken with development. As more items are treated development time will increase. Spent solution must be discarded and the dish thoroughly cleaned and new mixed Physical Developer Solution added. Once optimal contrast is achieved the item should be removed and placed in the rinse water dish. Step #4. Rinse Solution The Rinse solution is used to prevent further development of the impressions and remove unnecessary solution from the item. Place the item to be processed and the test print in a thoroughly cleaned, scratch free, glass processing dish large enough to accommodate the item without folding. Add sufficient amount of distilled water (tap water may be used) to ensure that the item is completely submerged. Gently rock the solution back and forth across the item during this process for 3-5 minutes. Option: Bench Rocker may be used. Care must be exercised to avoid overlapping or unnecessary creasing of the item and non-metallic forceps or tongs without serrated edges should be used to handle and transfer item(s) from the dishes. Remove the item(s) from the rinse solution and allow the item to dry completely prior to proceeding. A hot air dryer may be used to expedite the drying process. However, a hot iron should not be used as it may destroy the impression. 6 of 8

Examination / Preservation The gray/silver impressions may be more visible after the drying process is completed. TI02-46ENG-REV7 All visible impressions must be photographed immediately. Diffused illumination is usually satisfactory, but in some cases oblique lighting may be useful. Fluorescent examination may also prove useful, particularly if a confused background is present. After examination and photographing low contrasting impressions may be improved by re-treating the item starting with the Physical Developer Solution (step #3). It is not necessary to re-treat using the maleic acid solution. References U.S. Department of Justice, Federal Bureau of Investigation, Laboratory Division, Processing Guide for Developing Latent Prints. Revised 2000 Home Office, Scientific Research and Development Branch, Fingermark Visualisation Manual. Revised 2014. 7 of 8

SIRCHIE Products Vehicles Training 100 HUNTER PLACE, YOUNGSVILLE, NC 27596 USA 919-554-2244 800-356-7311 www.sirchie.com 8 of 8