BEVERAGE CONDUIT SYSTEMS

Similar documents
Orange Township Fire Department Fire Prevention Bureau

EUTECTIC EC-10DV Series

C O D E S & A M M E N D M E N T S

CITY OF PASADENA FIRE DEPARTMENT

DONALD H. BERG, ARCHITECT

Division 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21

COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

CORPRATE OFFICE 5257 NE MARTIN LUTHER KING JR. BLVD, SUITE 202 PORTLAND, OREGON USA

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

NOTICE: The information contained on the following page(s) was produced prior to May 1, On that date Reznor became part of Nortek, Inc.

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Making Crimp Connections

FIRE SPRINKLER SYSTEMS POLICY

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

SECTION WET-PIPE SPRINKLER SYSTEMS

Port of St Helens SIA Aircraft Hanger Scappoose, OR

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

FIRE SPRINKLER SYSTEMS POLICY

Sprinkler Permit Applications

APPENDIX H (DESIGN SUBMISSION CRITERIA)

HARVARD JOLLY, INC Dr. Martin Luther King, Jr. Street North

2. Welding Materials and Procedures shall conform to the ASME Code.

UNIVERSITY OF MISSOURI Fire Protection System Design 2016 Q1

Thermal Devices, Inc. Mount Airy, Maryland USA C D E F. Typical Maxiband Clamping

ESTIMATE SET-UP PACKAGE BID SCHEDULE ENTRY AND MAINTENANCE

Model RA Rectangular Aerator

Section COMMUNICATION EQUIPMENT ROOM FITTINGS. Section Communications Cabinets, Racks, Frames and Enclosures

SECTION GAS-FIRED RADIANT HEATERS

SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80

Corra/Clad MC Cable The contractors cable of choice in place of conduit and wire.

IDENTIFICATION FOR ELECTRICAL SYSTEMS July Electrical Systems

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Installation Guide COMBI. Before installing read this guide first

Compressed Air Distribution System

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Installation instructions

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

D400A/W Ice Machine. Installation Manual. D400A ice machine. D400W ice machine. Order parts online.

User Information Sheet 008 : 2010

Series P. Installation & Maintenance. Materials: A - CPVC B - Polypropylene C - PVDF

24 VAC SYSTEM CONTROL KIT

Series PX. Installation & Maintenance. Models: PX-3 PX-5 PX-7 1/2-HF PX-10-HF PX-15-HF. Materials: A - CPVC

A B A B4

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

Installation & Maintenance Data IM Contents

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

2018 Special-Lite ALUMINUM HARDWARE & LITES

plumbing for greywater

FRESH FROM THE KITCHEN FRESH FROM THE KITCHEN

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING

SECTION DRY-PIPE SPRINKLER SYSTEMS

Horizon Elite Ice Machine Models with RIDE Technology Installation Instructions for Vision

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

MODEL CF CEILING SUPPORTED CHIMNEY

SECTION (15530) - REFRIGERANT PIPING

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

The Safest Connections...

Marley Ultra Quiet Fan

PLAN REVIEW CHECKLIST

568X, 587X, 588X Series

24 VAC SYSTEM CONTROL KIT

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

UC Santa Cruz Campus Design Guide. Includes the following sections: None DESIGN REQUIREMENTS

TECHNICAL REPORT IEC TR Optical fibre cables Guidelines to the installation of optical fibre cables. colour inside. Edition 2.

PROJ. NO SECTION REFRIGERANT PIPING

Land Use and Environmental Services Code Enforcement. Table of Contents

SeasonMaker Hi-Line Fan-coil Units Model HSS S10 & S12

AVANI Grinding Booth

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

Power Pack Service Manual

ADVANTAGE SERIES. Popular Technologies for Outdoor Living

EUPEN CONNECTOR INSTALLATION MANUAL 50 & TRADITION

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

Energy-Free Waterers SF-2C, SF-4C, EF-2C, EF-4C

Brick Paver Installation Guide

DIVISION 21 - FIRE SUPPRESSION

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

24 VAC SYSTEM CONTROL KIT Model: CK-91F and CK-91FG

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

Standard Universal Sway Brace or Restraint Device Sway Brace Fitting

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

FIGURE 1 OUTAGAMIE COUNTY LANDFILL PROJECT LOCATION EAST LANDFILL LANDFILL OFFICE AND SCALE WEST LANDFILL EXISTING MRF COUNTY ROAD OO EXISTING FLARE

Building Division 201 SE 3 rd STREET (Second Floor) OCALA, FL Phone: (352) BUILDING CODE GUIDELINES FOR ELECTRICAL INSPECTIONS

SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET

PowerWave 2 Busway System

MAZAGON DOCK SHIPBUILDERS LIMITED

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Lucy s Pizza 100% CD Specification 06/22/2018

Installation and Maintenance Instructions

Underfloor distributors

DIVISION 21 - FIRE SUPPRESSION

AREA LIGHTING TABLE OF CONTENTS PUD SERVICE TERRITORY & CONTACTS FOR YOUR PROPERTY OVERHEAD FEED UNDERGROUND FEED. Electrical Service Requirements

Transcription:

BEVERAGE CONDUIT SYSTEMS MATERIALS CONSULTING INSTALLATION

March 2012 Easybar Beverage Management Systems

A EASYBAR BEVERAGE CONDUIT SYSTEMS COMPLETE BEVERAGE CONDUIT ROUTING SYSTEMS FOR THE BEVERAGE INDUSTRY Beverage conduit is an important component for any bulk dispensing system. Overhead aluminum and underground PVC conduit creates a leak-proof routing that protects your soda, liquor and beer lines from the elements. Easybar s conduit services include layout, CAD design, trade coordination, materials, and installation. We work with clients, designers and beverage vendors (including major soda purveyors) to make sure your beverage lines get where they need to go without excess material and expense. MADE IN THE USA

WHY EASYBAR CONDUIT? D C THE TOTAL BEVERAGE SOLUTION When Easybar supplies a liquor and / or draft beer system, a large part of our work is coordination with designers, construction, and client food and beverage operations. Adding conduit to our scope of work means we can use our contacts and knowledge of your beverage systems to design and provide a chase system that best suits your needs. We simplify your job with one point of contact and one contract. Because we can combine coordination efforts for all three systems, we offer discounts for contracts including conduit systems along with our liquor and beer equipment.

Separate chase for beer and liquor runs All runs 6 conduit material as required All runs attempt best straight line possible All 90 degree turns indicated are sweep 90 w/30 or 24 radius 24 x 24 x 12 minimum pull box size Pull sleeves every 100 (approx) or after every 3rd bend 30 or 24 radius for any tubing bends, including beneath bar All conduit end stub ups are required by local Health Department Conduit stubs up directly below station if possible Wherever possible, separate conduit is run to each station

BEVERAGE CONDUIT SPECIFICATIONS SIZES 2, 4, 6, 8, 10 MATERIALS CONDUIT LENGTHS Aluminum for overhead applications/pvc for buried applications galvanized and stainless steel available where conditions require 10 to 20 lengths BEND RADIUS- 2-24,4-24, 6-24 & 30, 8-32, 10-32 ALUMINUM BEND RADIUS PVC 4-24, 6-30, 8-48 COUPLINGS 4 Bolt Compression PULL SLEEVES 4 long aluminum or galvanized steel. Recommended every 75 or every 3 bends, whichever occurs first. No hanger required for installation. PULL BOXES Galvanized steel or powder coat finish - full panel access. Required For beverage line junctions and multiple changes in direction END FITTING HANGERS OPTIONAL FITTINGS AND EQUIPMENT Galvanized steel flared end Double rod clamp assembly Expansion joints, riser stands, nipple plates, seismic braces, firestop assemblies, multi-line hangers, end plugs, beverage trays and custom equipment & sizes C E F

SAMPLE CONDUIT DESIGN LAYOUTS

PULL SLEEVES AND JUNCTION BOXES PULL SLEEVE Install pull sleeves in accessible locations in order to provide access for line pulls and service. Our recommendation is every 75ft or every 3 bends (whichever occurs first). Pull sleeves are installed in a closed position. If assistance is needed during the beverage line pull process, loosen the nuts and slide the pull sleeve back for access to the beverage lines. When finished assisting with the line pull, move sleeve back into place and tighten. When a junction or multiple changes in direction are required it is important to install a pull box. You can specify the number of entrance and exit ports to coincide with the dimensions of a given box. We will specify the pull boxes accordingly. PULL BOX It is critical to maintain access to pull boxes until beverage lines have been pulled and beverage systems have been pumped up and tested. Once the testing is complete you may secure the removable access panel on the base of the pull box to secure the lines within. Sample pull box dimensions: (various sizes available) 10 x18 x24 12 x12 x36 12 x24 x24 18 x24 x36 24 x48 x48

Sweeps and Bends Easybar sweeps and bends utilize corrosion - resistant aluminum conduit tubing Bends shall be long - sweep type, with minimum center line radius of 24 Easybar advises clients not to specify multiple 90-degree bends in a single run without a pull box or sleeve. Easybar recommends that after the first 90 degree bend pull boxes (for junctions) or pull sleeves be implemented every 75ft to assist in the beverage line pulling process. Sweeps and bends assist in eliminating pinched beverage lines, ensuring that there is no restricted beverage flow during distribution from the bulk storage area to the dispensing outlets.

PARTIAL CLIENT LISTING Calder Racetrack - Winter Garden, FL Palace Casino - Biloxi, MS Hollywood Casino - Perryville, MD Hollywood Casino - Kansas City, KS Hollywood Casino - Columbus, OH Hollywood Casino - Toledo, OH Hard Rock Casino - Tampa, FL Aqueduct Casino (Resort World) - Jamaica, NY Valley Forge Casino - King of Prussia, PA Sands Casino - Bethlehem, PA Charles Town Races - Charles Town, WV Maryland Live - Hanover, MD Ringside Steakhouse - Portland, OR A B C

THE TOTAL BEVERAGE SOLUTION: DRAFT BEER LIQUOR CONDUIT Total Beverage Solutions by Easybar: Bulk liquor accountability equipment, draft beer systems, and streamlined beverage conduit systems together in a single package. With over 40 years of experience working with designers, general contractors, and corporate operators in the food and beverage industry Easybar ensures a package that will be best suited to the needs of the client without any excess materials or expense. Easybar simplifies the job with one point of contact and one contract. Because Easybar can combine coordination efforts for all three systems, discounts for contracts including conduit systems, liquor, and beer equipment provide a lower cost for Easybar s industry leading equipment and service. Contact us today and discover the Easybar advantage.

EASYBAR BEVERAGE DISPENSING SYSTEMS 19799 SW 95th Ave Suite A Tualatin, OR 97062 Ph: 503.624.6744 Fax: 503.624.6741 Email: info@easybar.com WWW.EASYBAR.COM