Analog Transmitter AT1000 AT1

Similar documents
Tank Gauge Transmitter AT-5000

Oil Leak Detector NAR300 System

Oil Leak Detector NAR300 System High Temperature

Proservo NMS5- / NMS7-

Process Alarm Module RTA 421

Level gauges Series LS Level indicator, switch and transmitter for liquids

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

PolyGard 2-channel Gas Controller MGC-03

General Specifications

FS-100 Series OUTLINE MAIN APPLICATIONS FEATURES LEVEL SWITCH

Pressure-Resistant and Explosion-Proof Electric Contact Pressure Gauges and Pressure Switches

Models TX-KE and TX-KP Toxic Gas Transmitters

PolyGard Single Point Controller SPC-X3-20XX for refrigerant gases and vapours

Functional Safety Manual Oil Leak Detector NAR300 System

INSTRUCTION MANUAL (ATEX / IECEx)

Figure 1 TWM1000 Electromagnetic Flow Converter. 1. Large, illuminated graphic display with intuitive operation 2. For AC and DC operation

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Sitron s CF Line of Flow Switch Monitors

ESSEX ENGINEERING CORPORATION

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

Alarm Modules Section E

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Micro-DCI 4 Channel Indicator Totalizers Series 53IT5100

OIL FILM DETECTOR (Long-distance correspondence Version)

Instruction Manual Model A

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

02/11/2015

Product data sheet AIRWIN additional modules Accessories AIRWIN

Speed and Frequency Seite 1 von 7

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

02/11/2015

Dust Concentration Meter

ABB MEASUREMENT & ANALYTICS DATA SHEET. C50 1/16 DIN controller / alarm unit

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

DIGITAL INDICATOR JIR-301-M

PH / ORP Analyzers MODEL OPM223/253. Wedgewood Analytical Inc. Liquid Analytical Measurement & Control Specialists DESCRIPTION FEATURES APPLICATIONS

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Danfoss gas detection unit Type GD Heavy Duty

Dräger Polytron 5100 EC Detection of toxic gases and vapors

JIR-301-M No.JIR31E To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

General Specifications

SP-2400 & 2410 Series Smart Valve Positioner (Linear & Rotary)

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

Temperature Controllers

Model 144H. Product Data Sheet , Rev DB February Content

2500 Automatic Tank Gauge

Infrared Detectors. Special-Sensors for. Automation

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

RK-05 Combustible Gas Transmitter Operator s Manual

CN-6000 Series. Features. Ordering information CN C1. Part descriptions. 5 ( key: Used to enter parameter set mode, move to parameters,

for relative humidity and temperature

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

LC1350 Level Controller

85 Uncompensated SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Ultrasonic Level Measurement nivopuls FDU 10 S

SCHMIDT LED Measured Value Display MD Instructions for Use

Micro/Ultra Filtration System StamoClean CAT 430

DICTATOR Hold-Open Systems for Hazardous Areas

Temperature Measurement Transmitters for field mounting

MODEL: 47LT. Digital Panel Meters 47 Series. [3] DISPLAY COLOR R: Red YR: Orange G: Green BG: Bluegreen B: Blue W: White. [4] POWER INPUT AC Power

Differential pressure sensors

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

SHIMADEN DIGITAL INDICATORS

UDC100 Universal Digital Controller Specifications

Hygro/hygrothermal transducers (hygrometric)

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Rotameter series 250 metal tube variable area flowmeter

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Ionizer Basic Fan Type ZJ-FA20. High-speed, High cost performance Ionization

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

Inductive Conductivity Measurement. Simultaneous display of conductivity/ resistance/salinity and temperature; large measurement symbol.

MEAS CAL ALARM WASH CONF APT4000 TC

Safety Instructions Omnigrad S TR/TC6x

Dissolved Oxygen Analyzers

Gas cylinder scale Model GCS-1

ELECTRONIC HUMIDISTAT: H270

User s. Manual) Model VJS7 Potentiometer Converter (Multi-function) (Isolated Single-output and Isolated Dualoutput

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Hygro/hygrothermal transducers (hygrometric)

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

CMT MANUAL 6. NMC SENSORS

Manual for QX0201 Push Button

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

Ionisation single-tube smoke detector for duct mounting

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

Transmitter for O 2 ZD21. Operation Manual

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

Safety vacuum drying oven for flammable solvents

Transcription:

Technical Information Analog Transmitter AT1000 AT1 Alarm Transmitter for Mechanical Level Gauges Application AT1 analog transmitter is designed to be installed to the LT, and LTC series float level gauge. One of the main functions of the transmitter is to transmit the level gauge s signals into voltage, electric current, and resistance output signals. Because this model has a variety of output signal types, it has an extensive connection compatibility with various level setting devices. In addition, the alarm and adjustment contact signals are equipped with up to six points, enabling the operator to direct the valves and pumps with this transmitter alone. This transmitter enhances the capacity of your level gauge by enabling you to operate the device from remote locations. AT1 transmitter can be utilized in wide range of industries. The dependability of this device has been tested and proven over the years in a variety of uses. Application includes: water tanks, sewage plants, oil depots, chemical solvent storage tanks, petroleum refineries, foods, paints, and organic chemicals. Features and Benefits Transmits the tank level by analog signals. Select between voltage and electric current for the output signal according to the the purpose. Easy maintenance due to simple mechanism TI 00460G/08/EN/03.13 71240708

Analog Transmitter AT1000 AT1 Table of Contents Function and System Design......................... 3 Operating System.....................................3 Technical Data.................................... 4 Output............................................4 Accuracy.......................................... 4 Power Supply...................................... 4 Power Consumption..................................4 Load Impedance.....................................4 Ambient Temperature.................................4 Storage Temperature..................................4 Measuring Range....................................4 Hysteresis..........................................4 Cable Entry........................................4 Transmission Line (per one contact)...................... 4 Alarm Contact......................................4 Contact Rating......................................4 Degree of Protection..................................4 Color.............................................4 Weight............................................4 Operating Conditions: Wiring........................ 5 Wire Connection.................................... 5 1. AC: 4-20mA or 10-50mA Output................... 5 2. AC: 0-1mA, 0-20mA, 0-10mV or 0-1V Output........ 5 3. DC: 4-20mA or 10-50mA Output................... 5 4. DC: 0-10mA, 0-20mA, 0-10mV or 0-1V output....... 5 5. With Alarm Contacts............................... 6 External Dimensions............................... 7 Flame Proof........................................ 7 Weather Proof...................................... 7 Cable Entery....................................... 8 Operating Conditions: Installation..................... 8 Installation of Transmitter............................. 8 Certificates and Approval............................ 9 Ex Approval....................................... 9 Protection Class..................................... 9 Ordering Information.............................. 10 AT1............................................ 10 Documentation................................... 11 Technical Information............................... 11 Operating Instructions............................... 11 2 Endress+Hauser

Analog Transmitter AT10000 AT1 Function and System Design Operating System The remote signal is produced by the rotation angle of the brush on the potentiometer, as indicated in the below figure. The brush rotation corresponds to the tank level. The resistance value is determined and transmitted based on the position of the brush. Potentiometer Wiper Resistor Deviation Amounts from Level Gauge Variable Wiper (Brush) Potentiometer (Wiper Resistor Type) Figure 1: Potentiometer It is possible to apply a direct current to this potentiometer, as indicated in the figure below. The resistance value is converted to direct current or direct voltage and is output. Voltage or Current Output Direct Current Output Voltage-to-current Conversion Direct Voltage Output Direct Current Power Supply Potentiometer Figure 2: Voltage and Current of Potentiometer Endress+Hauser 3

Analog Transmitter AT1000 AT1 Technical Data Output 4-20mA, 10-50mA, 0-1mA, 0-20mA, 0-10mV, 0-1V Accuracy Power Supply Power Consumption Accuracy Analog Output 4-20mA, 10-50mA Output: Within ±0.5% 0-20mA, 0-10mV, 0-1V Output: Within ±0.7% 0-1mA Output: within ±1.5% Alarm Contact Output ± 0.5% (for full span) DC24V (DC20~40V valid), AC100V/110V/200V/220V ±10%, 50/60Hz Approximately 5VA Load Impedance Current Output (Max. Impedance) Voltage Output (Min. Impedance) Current Voltage 20VDC 24VDC 40VDC 100VAC 110VAC 200VAC 220VAC 4~20mA 200Ω 400Ω 1100Ω 630Ω 10~50mA 80Ω 160Ω 440Ω 250Ω 0~1mA 18kΩ 22kΩ 38kΩ 25kΩ 0~20mA 900Ω 1100Ω 1900Ω 1330Ω 0~10mV 500Ω 0~1V 30kΩ Ambient Temperature Storage Temperature Measuring Range Hysteresis Cable Entry Transmission Line (per one contact) Alarm Contact Contact Rating Degree of Protection Color Weight Weather proof type: -20 ~ +60 C Flameproof type: -10 ~ +40 C (Accuracy coverage : 0 ~ 40 C) -20 ~ +60 C 0-1.5m, 2.5m, 3m, 3.5m, 4m, 5m, 6m, 8m, 10m, 12m, 14m, 16m, 20m, 25m 30m Within 2% of measuring range Flameproof with cable gland (B): G3/4 TF16-11, G1 TF22-15, G1-1/4 TF28-20 Flameproof (E): G3/4, G1-1/2 Weather proof (W): G3/4, G1-1/2, NPT3/4, NPT1, M25 DC: two or three lines AC: four lines 2, 4, 6 points, Micro switch (SPDT) Select any of the following contact: A contact (normal open) B contact (normal close) C contact (transfer) TIIS Ex d rating: 250V 4.2A, 1050VA, 180W Allowable contact rating: Alarm 2 points (A, B, C contact) 220VAC 2.8A, 125VDC 0.5A Alarm 4 points (A, B contact) 220VAC 2.8A, 125VDC 0.5A Alarm 4 points (C contact) 220VAC 2.2A, 125VDC 0.5A Alarm 6 points (A, B, C contact) 220VAC 2.2A, 125VDC 0.5A Weather proof: IP65 Flame proof : d2g4 Silver Weather proof: approximately 7kg Flame proof: approximately 13kg 4 Endress+Hauser

Analog Transmitter AT10000 AT1 Operating Conditions: Wiring Wire Connection 1. AC: 4-20mA or 10-50mA Output To ensure the accuracy of the transmitter and receiver, it is important to set the wiring and connection of the circuit to be within the accepted range. Because AT1 transmitter has several output signals, be careful of the impedance that is caused by the circuit resistance as a result of electric output (For alarm contact equipped model, refer to 5 also) AC power supply Level indicator Potentiometer Converter Power supply unit Terminal Figure 3: AC Power 1 2. AC: 0-1mA, 0-20mA, 0-10mV or 0-1V Output (For alarm contact equipped model, refer to 5 also) AC power supply Level indicator Potentiometer Converter Power supply unit Terminal Figure 4: AC Power 2 3. DC: 4-20mA or 10-50mA Output (For alarm contact equipped model, refer to 5 also) DC power supply Level indicator Potentiometer Converter Terminal Figure 5: DC Power 1 4. DC: 0-10mA, 0-20mA, 0-10mV or 0-1V output (For alarm contact equipped model, refer to 5 also) DC power supply Level indicator Potentiometer converter Terminal Figure 6: DC Power 2 Endress+Hauser 5

Analog Transmitter AT1000 AT1 5. With Alarm Contacts In case of with contacts in 1, 2, 3, 4, the following circuits are provided. A Contact (Normal Open) Terminal No. 5 6 7 8 9 10 11 12 13 14 15 16 2 points 4 points 6 points Figure 7: A Contact B Contact (Normal Close) Terminal No. 5 6 7 8 9 10 11 12 13 14 15 16 2 points 4 points 6 points Figure 8: B Contact C Contact (Transfer Contact) Terminal No. 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 2 points 4 points 6 points Figure 9: C Contact 6 Endress+Hauser

Analog Transmitter AT10000 AT1 External Dimensions Flame Proof Alarm Contacts: 0, 2, 4, 6 Main Body 266 Locking Clamp Cover Ø136 193 Ø218 Locking Clamp Terminal Box Figure 10: Flame Proof Weather Proof Alarm contacts: 0, 2 In case of Cable Entry G3/4,NPT3/4 266 Main body Ø218 Cover Ø116 203 Terminal Box Figure 11: Weather Proof 1 Alarm contacts: 0, 2, 4, 6 266 Main Body Ø136 Ø218 Cover B A 193 Terminal Box Figure 12: Weather Proof 2 Endress+Hauser 7

Analog Transmitter AT1000 AT1 Cable Entery 070:Cable Entry A B A Thread G 3/4 B Thread G 3/4 Thread G 3/4 C Thread G 1-1/2 D Thread G 1-1/2 Thread G 3/4 E Gland G 3/4 TF16-11 F Gland G 3/4 TF16-11 Gland G 3/4 TF16-11 G Gland G1 TF 22-15 H Thread NPT1 K Thread M25 M Gland G1-1/4 TF28-20 Gland G 3/4 TF16-11 Q Thread NPT3/4 R Thread NPT 3/4 Thread NPT 3/4 Operating Conditions: Installation Installation of Transmitter Terminal box Transmitter B Level Gauge Sideways A Universal Fitting Thick Steel Flexible Fitting with M-type (both ends) Rnion Refer to cable entry for transmitter. Figure 13: Transmitter and Float Tank Gauge Caution! When installing the transmitter with cable grands, ensure to use cable glands which are attached to the transmitter. Select an option for cable glands in the feature 070 of the order structure (refer to "2.2 Ordering Information"). 8 Endress+Hauser

Analog Transmitter AT10000 AT1 Certificates and Approval Ex Approval TIIS, with cable gland TIIS d2g4 TIIS, (Cable entry) TIIS d2g4 Protection Class IP65 Endress+Hauser 9

Analog Transmitter AT1000 AT1 Ordering Information AT1 010 Output: 1 4-20mA 2 10-50mA 3 0-1mA 4 0-20mA 5 0-10mVDC 6 0-1VDC 9 Special version, TSP-no. to be spec. 020 Power Type: 1 AC 2 DC 030 Alarm Output: 0 Not used 2 2 - point 4 4 - point 6 6 - point 040 Approval: B Flame proof d2g4, TIIS + cable gland E Flame proof d2g4, TIIS W Weather proof IP65 Y Special version, TSP-no. to be spec. 050 Function: 0 Basic version 9 Special version, TSP-no. to be spec. 060 Power Supply : 1 100VAC, 50/60Hz 2 110VAC, 50/60Hz 3 200ACV, 50/60Hz 4 220VAC, 50/60Hz 5 24VDC Y Special version, TSP-no. to be spec. 070 Cable Entry: A 1 x thread G 3/4 B 2 x thread G 3/4 C 1 x thread G 1-1/2 D 1 x thread G 1-1/2, 1x G 3/4 E 1 x gland G 3/4, TF16-11 F 2 x gland G 3/4, TF16-11 G 1 x gland G 1, TF22-15 H 1 x thread NPT1 K 1 x thread M25 M 1 x gland G 1-1/4, TF28-20,1x gland G 3/4, TF16-11 Q 1 x thread NPT3/4 R 2 x thread NPT3/4 Y Special version, TSP-no. to be spec. 080 Installation gauge: 1 LT1100/LT1200/LT3100/LT3200 R:300mm low pressure LT version 2 LT1400/LT1600/LT3400/LT3600 R:300mm high pressure LT version 3 LTC2100 L:600mm 4 LTC2230/LTC2240 R:600mm 9 Special version, TSP-no. to be spec. 090 Measuring Range A 1.5m 1 2.5m C 3m D 3.5m E 4m 2 5m F 6m G 8m 3 10m 10 Endress+Hauser

Analog Transmitter AT10000 AT1 090 Measuring Range H 12m J 14m 4 16m 5 20m K 25m 6 30m 9 Special version, TSP-no. to be spec. 100 Alarm Contact 0 Not used 1 A= normal open 2 B= normal closed 3 C= transfer contact 110 Color 0 Silver 9 Special version, TSP-no. to be spec. AT1- Documentation Technical Information TI00458G Float Gauge LT11/LT12/LT14/LT16 TI1121G Float Gauge LTC2230/LTC2240 Operating Instructions BA00414G Analog Transmitter AT10000 AT1 Endress+Hauser 11

Endress + Hauser Yamanashi Co., Ltd. 862-1 Mitsukunugi Sakaigawa-cho Fuefuki-shi Yamanashi, 406-0846 Japan Phone: ++81 55 266 4964 Fax: ++81 55 266 4969 http://www.endress.com TI00460G/08/EN/03.13 71240708 FM+XML/DITA 11.0