SAEY 92 (TOP) WOOD/COAL

Similar documents
MODEL SORDO SORDO SORDO SORDO 80 Flatline

Figure 1 Solid fuel cook-stove KMŠ 70 and KVŠ 90H

Varde Aura. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

Varde Shape. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

Operating and installation instructions for Fire Lotus H586

TECHNICAL MANUAL. Multifuel Stove Model EW1MF. To be retained by the user for future reference. Serial Number. Document EW1MF 0209

Bergen PRPMXXXX. Smoke Control Kit Additional Installation and User Instructions for use in Smoke Control Areas

CE EN13240 ENJOY YOUR STOVE SAFELY. Multifuel Cast Iron Stove INSTRUCTION MANUAL

Quadro 1, 2 & S-31A Insert

SAUNA HEATER INSTALLATION AND OPERATING MANUAL

Installation & Manual. Model T-25

USER S MANUAL, MAINTENANCE MANUAL INSTALLATION INSTRUCTIONS

Page 1. Cube Ref:

MG SERIES - ENERGY CLASS A. Meeting the. MG series 1 / 7

1. Contents Principle General information Parts list Assembly Technical drawing... 18

Troubleshooting and Maintenance: Wood Stoves

Dovre 700CBW Cast Iron Wood Stove INSTALLATION INSTRUCTIONS 700G/1095

Installation and Operating Instructions

Nectre Inbuilt LE. Operating Instructions. Efficient Warm Friendly. Keep instructions in a safe place for future reference.

Nectre N60. Operating Instructions. Efficient Warm Friendly. Keep instructions in a safe place for future reference.

Nectre MK2 LE. Operating Instructions. Efficient Warm Friendly. Keep instructions in a safe place for future reference.

TECHNICAL MANUAL. Multifuel Stove Model MV1MF. To be retained by the user for future reference

TECHNICAL MANUAL. The Buxton. Multifuel Stove Model BX1MF. To be retained by the user for future reference

Technical Specifications Panoramic FX1

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

PER-EKO type KSW & KSW PLUS Instruction Manual

INSTALLATION AND OPERATION MANUAL

Oxford 5. Operation and Installation Manual. Version A 21/06/2017 (MZSOX5SMB) IMPORTANT

Instruction Manual: Le Jurassien Ref 3701

VASKA C11. gas-fireplace user manual. Saturnus 8 NL-8448 CC Heerenveen Postbus 219 NL-8440 AE Heerenveen T. +31(0) F.

PELLET BURNER PV 350

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN

Rocket heater GAMERA

Cooker Hood Instruction Manual

Proper Operation of Masonry Stoves and Furnaces

Novus. Multifuel Stove Model Novus. To be retained by the user for future reference. Thank you for purchasing an ACR Heat Products stove

R 18 E MANUEL D'UTILISATION GEBRAUCHSANWEISUNG INSTRUCCIONES DE USO OPERATING MANUAL ISTRUZIONI D USO GEBRUIKSAANWIJZING

CHARNWOOD COUNTRY 6 FT

Cooker Hood Instruction Manual

LISEO Insert. European Standard Certification UNE EN inserts. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

Oakdale. Multifuel Cast Iron Stove Model FB1MF. To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove

Ashdale. Multifuel Cast Iron Stove Model FB2MF. To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove

LIMOUSIN. Wood stove. Model : Output : 10 kw. Technical manual. to be saved. by the user. for future reference.

LISEO STOVES. European Standard Certification UNE EN stoves. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

Website:

Birchdale. Multifuel Cast Iron Stove Model FB4MF. To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove

INSTRUCTIONS FOR INSTALLATION, SETTING AND USE

CHARNWOOD COUNTRY 8B WOODBURNER OPERATING INSTRUCTIONS

INTRODUCTION TO HITZER STOVES INSTALLATION AND OPERATION

HOMEOWNER'S GUIDE FOR YOUR CONTEMPO FIREPLACE TABLE OF CONTENTS

qüé=`üáãåéó An effective chimney is an important part of any successful wood-burning system.

MANUAL INSTRUCTION Solid fuel cooker for central heating - SUPER-THERMO MAGNUM

INSTRUCTIONS FOR INSTALLATION AND USE OF ZINO 700,900,1100

Troubleshooting Guide

Mendip 5 standard and pedestal stove Multi-Fuel, Wood, Smoke control model 4.8 kw / 5.2kW Space Heating Stove

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

SAVOY MK2 Model : Technical manual STAUB FONDERIE

Malvern II. Multifuel Stove Model MAL2MF. To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove

Installation and Operating Instructions for the following Woodsman models

MANUAL FOR USE AND INSTALATION STOVE MODELS: D11-D17

Camargue. Model : Technical manual. Output : 10 kw. to be saved. by the user. for future reference. Wood stove NF EN 13240

Importance of a Draught Regulator

Gasification boiler PYROLYT INSTRUCTION MANUAL. ver. 1.1

Sauna Heater. Installation and Manual

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

Neo. Multifuel Stove Model Neo 1 / Neo 3. To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove

User Manual Watt Drop-In Induction Range. Model: ID18DB 08/2017. Please read and keep these instructions. Indoor use only.

Firebird Smoke Exempt Inset Stove

HAWK GAS STOVE. Installation and Servicing Instructions

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

INSTRUCTION. for installation and operation of solid fuel fireplace

Furthermore, the fire flaming in your FIREPLACE hearth creates an intimate atmosphere for your family and friends.

DÉCOFIRE. Contemporary CHIMENEA. Assembly, Safety & Operating Instructions FOR OUTDOOR USE ONLY READ INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY OR USE.

SOLID FUEL RANGE COOKER

Exmoor/Exe/Devon. Freestanding Stove. Instructions for fitting Smoke Control Kit. For use in GB & IE (Great Britain & Republic of Ireland).

Studio. Freestanding Cassette Range. Instructions for Use. For use in AU & NZ (Australia and New Zealand)

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

version 1.2 Made by NARVI Oy Finland Aito 16 / 20 / 24 / 16 VS / 20 VS / 24 VS Installation, user and maintenance instructions

Installation and Operating Instructions. Models: T4-12LOW-9IS

Malm Fireplaces, Inc. 368 Yolanda Avenue, Santa Rosa, CA (707) Fax: (707)

SAVOY. Model : Output:8kW Technical manual. to be saved by the user for future reference. Multifuel stove

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE

Fireplace inserts. Model SK1000, SK2000. Installation instructions Care and firing instructions

Installation, operation and care Firewood boiler Vedolux 40 UB

Langdale. Woodburning Cast Iron Stove Model FB6WB. To be retained by the user for future reference

Installation and Operating Manual

User Manual. If you have any issues or questions, please contact us via

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

FM5 Freestanding Multifuel Dry Stove

User Manual. If you have any issues or questions, please contact us via

Ceramic Kettle A INTRUCTION MANUAL. Please note this item is not a teapot and should not be used as such.

Model BR660VA Heat Engine

VASKA B11. gas -fireplace installation guide

Operation instructions

LIMOUSIN. Multifuel stove. Model : DIN EN : Output : 10 kw. Technical manual to be saved by the user for future reference

V-ZUG Ltd. Range hood. Levante. Operating instructions

Main components. Buying all components from same manufacturer or reseller it guarantees better compatible and service if something happens

Course introduction 2. 1 Appliances and fuels 3. 2 Combustion Legislation Air supply Flues and chimneys Commissioning 83

Transcription:

SAEY Home & Garden NV Industrielaan 4 B - 8501 Kortrijk-Heule www.saeyheating.com Documentation addressed to the user and installer Installation and Operation Manual SAEY 92 (TOP) WOOD/COAL 478.0292.XX 478.0392.XX Saey 92 coal Saey 92 TOP coal 1

Contents 1. GENERAL INFORMATION... 3 2. TECHNICAL CHARACTERISTICS... 4 DIMENSIONS OF THE STOVE... 4 3. IMPORTANT... 4 4. INSTALLATION OF THE STOVE... 5 5. CONNECTION OF THE STOVE TO THE CHIMNEY... 5 6. SUITABLE FUEL... 6 7. BEFORE FIRST USE... 6 8. WARNING! PLAYING CHILDREN!... 6 9. STOKING UP OF THE FIRE... 7 10. FILLING WITH COALS... 7 11. STOKING UP THE FIRE WITH BROWN COAL... 7 12. STOKING UP THE FIRE WITH BRECHCOKES... 8 13. REFILL WITH FUELS... 8 14. STOKING UP THE FIRE WITH WOOD... 8 14.1 REBUILD... 14.2 REFILL... 14.3 SERVICE... 14.4 ASH REMOVAL... 15. REMOVAL OF THE ASHES... 9 16. MAINTENANCE... 9 17. INSTRUCTIONS... 9 18. SPARE PARTS... 10 19. FAULTS... 12 20. GUARANTEE... 14 2

1. General information Dear user! When you purchased this SAEY 92, you chose a high class cast-iron combustion and heating appliance. Our warmest congratulations! We devoted a lot of attention to the technology, but also to the materials used, the processing and the compactness of the appliance. This enables us to guarantee problem-free operation. If you wish to achieve maximal performance in terms of ecological and economical considerations, you should comply with this installation and operation manual and carry out its instructions. If the stove is damaged due to non-compliance with the installation and operation manual, the guarantee will no longer be valid. If the stove is built in, the applicable laws and local regulations regarding fire prevention and architecture should be complied with. Are you looking for further information or technical data? Installation problems? Contact your distributor first. Please keep in a safe place! Subject to amendment! Sketches are not contractually binding! 3

2. Technical characteristics TYPE S 92 H/K Maximum heating capacity kw 5-14 Performance class % 1 (h>70) Dimensions of the stove Height stand. type TOP type 765 800 Width 710 Width stand. type TOP type Rear connection Distance middle connect.pipe - floor Stand. type TOP type 550 580 ja 557 557 Outside Ø of the connector pipe Ø 150 Dimensions glass HxWxThickness 461x265x4 Space to heat m 225 Small filler door opening 18.5 x 17 Max. length for wood Type anthracite Weight op the stove 500 20/30 S 92 ca. kg 200 S 92 TOP ca. kg 218 3. Important WARNING! - The user of a stove must read the manual attentively before using the appliance for the first time. - If your stove has been installed in the living room, you must ensure a sufficient supply of fresh air in any case. - The appliance should only be used with closed doors. - When the doors remain open once the stove is functioning, the thermostat function is disabled and the inflow into the stove is no longer being controlled. The danger then arises that the stove will become too hot, so that slag formation takes place and the parts exposed to the flames are damaged. -This kind of damage is not covered by the guarantee. - Shut the stove doors and turn off the thermostat, even when the stove is not in operation. 4

4. Installation of the stove It is only when the appliance was connected by an authorised installer that you can be certain that the installation and fire protection instructions were observed. The most important connection component is the chimney. Make an appointment with a recognised chimneysweeper so that the specific regulations applicable in the country of use in this regard, are also complied with. Also pay attention to the following: The stove is suitable for a chimney with several shafts. For this purpose, the stove must be used with closed doors. The inflow of air must be sufficient in whatever space the appliance has been installed. Tightly closed doors and windows may cause problems in this regard. Preferably place your stove near the chimney (hearth). A heat-resistant, fireproof base (bottom plate) must be placed underneath the stove. These bases (made of cast iron, steel sheeting, ) are available coercially. In any case, ensure that the base is fireproof. Flaable objects such as doors, furniture, woodwork etc. must be at a distance of at least 60 cm. Thanks to the protective plate at the back of the stove, the appliance may be placed up to 30 cm from the wall. 5. Connection of the stove to the chimney A strong chimney draught makes it possible to connect the stove directly to the chimney (with outlet at the back). The diameter of the smoke duct must correspond with that of the connector (150 ). When the draught of the chimney is insufficient, under 0,08 mbar (0,8 WS) the stove must be connected with a perpendicularly smoke duct of 1 till 1,5 m length with the chimney (outlet above). The smoke duct must be sealed at all connection points! Attent ion is specifically drawn to the danger of escaping fumes. False air results in a weaker chimney draught. If the chimney draught is too strong, the installation of a draught regulator is recoended. Take note of the following precautionary measures before the smoke duct is installed: The diameter of the smoke duct may not be reduced, the smoke duct may not be made smaller and it may not be positioned horizontally, but should rise towards the chimney at a slight angle. The stovepipe must fit into the chimney opening to make the discharge of fumes possible. Make provision for a double lining in this regard. Chimney connections of different stoves may not be so positioned opposite one other, i.e. at the same height. This may obstruct the discharge of exhaust fumes. The minimum distance between two outlets for fumes should be at least 30 cm. Do not connect too many stoves to one chimney too many connections hamper the upward draught. Ask you chimney sweeper for advice. The chimney may not conduct any false air. Ensure that the chimney control valves as well as the cleaning openings in the cellar are closed. The smoke duct must be securely attached to the connector. The chimney and the stove must be cleaned once a year by a recognized chimney sweeper. 5

6. Suitable fuel The SAEY 92 stove makes use of the following fuels: * Anthracite, grain structure 20/30 * wood: logs with sticky bark, e.g. cleaved logs with a length of 33 cm. The wood should be stored for about 2 years, and should have a maximum residual humidity level of 20%. Wet wood does not burn well and produces smoke, resulting in condensation and a tar discharge, which makes the stove dirty. Take care: DO NOT burn waste matter. When burning wood a rebuilding of the stove is necessary and some further regulations and air supplies are different to handle. 7. Before first use When used for the first time, the stove must be dried out first. For this purpose, use a little fuel to keep the fire burning for one hour. Thermostat on position Max.Open. Monitor the protection process carefully. In this regard, carefully wipe off any condensation drops before the residue gets a chance to burn into the enamel (e.g. the lacquer). 8. Warning! Playing children! A stove gets hot, especially the covering plate, the casing and the glass pane. Install your stove in a safe place in order to prevent children from touching it. Even if all the safety regulations are observed, there is still a risk of accidents occurring. KEEP SMALL CHILDREN AT A SAFE DISTANCE 6

9. Stoking up the fire When the stove is lit thermostat: on position 8 Open the door with the glass panel and put crumpled newspapers on the fire grating, with a handful of splintered wood (thin wood) on top of it. Alternative: 4 5 firelighters. Pour on that a small amount fuel. After the stove has been lit, the door with the glass panel must be firmly closed. The door of the ash pan must be opened slightly so that the condensation vapours that are released will not be deposited on the cold door with the glass panel. Monitor the combustion process, and close the door of the ash pan after about 10 minutes. IMPORTANT: The door of the ash pan and the door with the glass panel should now not be opened again, except for the purpose of topping up. 10. Filling with coals You may start to fill the stove when the lighting fuel is totally burnt up and if the base is still glowing sufficiently. The filling funnel is filled as it suits you but it has to be at least half full. The stove may only be filled till the mark sign. The above gas slots in the filling funnel must stay free so that the gases, carbonized at a low temperature, could escape. When max. filled the stove can work 14 till 16 hours! When max. filled with lower thermostat position till 24 hours. To stoke: - air drawer: fix closed - thermostat: position 2-8, as you desire IMPORTANT: It is recoended to put the thermostat on a lower position after half an hour. For this purpose are you sure that the burning is carried out correctly. The ignition of the thermostat depends also on other factors: the local circumstances, the condition of the building and the chimney. After a bit experimentation, you will regulate easily and definitely your stove. 11. Stoking up the fire with brown coal The amounts usable fuel (long briquettes 6 7 and little briquettes) is defined by the desired warmth. Only when there is much warmth necessary, the stove has to be filled fully. The smallest position (1-2) is the glow position. For heating in the night, when there is only a small need to warmth, the 3-4 long briquettes are enough or 2 spades briquettes on the burning grid without poking in the ashes. Put the thermostat on minimal air supply (1-2). 7

12. Stoking up the fire with brech-cokes When the burning is weak, the brechcokes needs a bigger amount of burning air. It is not possible to make the stove work with a thermostat in the smallest position, what the case is with other fuels. Above all, the thermostat could only be put gradually on a smaller position. 13. Refill with fuels Coal: with every refilling turn, you have to use a shaking grid. Before opening the filling funnel lid, the thermostat has to be put on position 8 open. So that the outlet gases that are located in the filling funnel or in the burning room, not come on the place where the stove is located. Wood: not poke: (see 14.4) 14.1 Stoking up the fire with wood - Rebuild When you want your stove works with wood, then there is a small rebuild necessary. Following steps need to be done: Remove the filling funnel after you opened the lid Place the wood grid you can buy optionally instead of the coal grid The secundairy air drawer between the 2 front doors must be open (must be closed while using coals) With the 2 air drawers you can find above the fire door, you can fix the air supply. Release the air drawer button by turning ¼ of a turn left. (should be closed while using coals) 14.2 Stoking up the fire with wood - Refill To stoke - thermostat: position 1-2 (base position wood) - air drawer: open max. The logs should be inserted through the right-hand filler door or the door with the glass panel and placed on the still sufficiently glowing base, in no more than 2 layers. Do not overfill. 14.3 Stoking up the fire with wood - Service The burning of wood is accompanied by high flames and heavy smoke production. Wood must be burnt up rapidly and with a constant oxygen supply. The combustion process may not be slowed down under any circumstances. Avoid an excessive amount of fuel in any case, otherwise the energy surge become too great and too much heat will be lost. Negative consequences could be: * smouldering fire, condensation and tar discharge * excessive production of soot * inconvenience caused by smoke (emission of harmful substances) * danger of asphyxiation 8

WOOD PROVIDES INTENSE COMBUSTION OF SHORT DURATION/ Sustained combustion is only achieved through regular top-ups, which means: only when the wood has almost been burnt up and the degassing process completed high flames are reduced to small, low flames and wood is converted into glowing embers can the emission of heat be slowed down by closing the air slider above the glass door (see image). 14.4 Stoking up the fire with wood Ash removal Take note: de not poke the fire when the appliance is in operation. Wood combustion produces little ash. Because of this, the remains of the embers continue to smoulder in the glowing ash. 15. Removal of the ashes The ashes from the stove have to be removed daily 1 till 2 times. Poking happens with a shaking bar that is located on the back, with a closed ash door. From time to time the slag rests has also to be removed. This can happen with a pull grid. The pull grid is located behind the ash door and the handle is pulled away. In this purpose you get an opening and you can easily scrape the ash rests and slag with a poke. The ash pan may be maximally filled with ash to the upper edge. No ash cone may be formed: otherwise cooling of the combustion chamber becomes impossible and the cast iron parts would begin to melt. The ash door should always be closed when the stove is in operation. If this is not done, the stove overheats and is damaged. 16. Maintenance The smoke discharge duct (between the checking-plate and the rear wall) must be cleaned after every heating season at least 1 x a year. By removing the control damper, you will be able to reach the smoke discharge duct. This makes it easy to remove the fly ash from the discharge duct as well as the connector. The control damper must be put back correctly afterwards. It is recoended that, after the feating season (i.e. during the suer months) the flue pipe between the stove and chimney should be removed or sealed in order to prevent condensation and/or corrosion in the stove. This improves the durability of your stove. Before starting again to heat with your stove after a period of not using it is recoended to decrease the tension of the screws on the glass by using a screwdriver. In this case you will raise the lifespan of the glass and avoid possible cracks. 17. Instructions With the luxury appliance you may put just after 1 month in use on the polished filling funnel lid and the carrier water kettle, pans, etc. No water may be spilled on the hot plates, to prevent cracks from forming. 9

18. Spare parts 10

11

19. Faults Malfunctioning Cause Solution The fire is not burning well Glass soon gets dirty A lacquer odour is emitted and smoke develops Wood too moist Check; max. residual moisture 20% Wrong fuel Use only the fuel allowed for the appliance Chimney draught too weak: (Minimal pressure: 10Pa at the heating gas connector pipe) Check the air-tightness of the outlet Light a kindling fire in the chimney Close any open doors of other appliances connected to the chimney. Close the cleaning hatches of the chimney If necessary, clean the connector pipe Not enough combustion air Check the ventilation installation of the residence or cooker hood, and open a window if necessary Wood too moist Check; max. residual moisture 20% Wrong fuel Fuel not small enough max. circumference is 50 cm Use only the fuel allowed for the appliance Too much wood has been added Do not add more than 2 to 3 pieces of wood Not enough combustion air Check the ventilation installation of the residence or cooker hood, and open a window if necessary Curing of the primer used Rapid heating of the heating appliance will result in an odour being given off (see 3.1). This will dissipate after a while Condensation High temperature difference Open the door slightly during the heating phase. Do not leave the appliance unattended during this phase! Inconvenience caused by smoke Chimney draught too weak: (Minimal pressure: 10Pa on the outlet connector pipe) Fuel has not been burnt up completely Check the air-tightness of the outlet Light a kindling fire in the chimney Close any open doors of other appliances connected to the chimney. Close the cleaning hatches of the chimney If necessary, clean the connector pipe In principle, fuel should be topped up only when no more orange flames are visible in the stove. Gradual capacity regulator (thermostat) Service grip 12

Ash pan Base position: open (outside) Base position: open (outside) Mark sign in filling funnel lid (max. filling height coal) Max. stacking height of logs Opening the filling funnel lid take out the filling funnel Take out the cleaning panel 13

20. Guarantee The manufacturer guarantees a. impeccable quality and processing of the raw materials according to the stated requirements b. assembled by an expert The guarantees a. en b. provide for free repairs to the appliance, more specifically to parts declared unfit for use. Such parts are only replaced free of charge when it can be proven that there are flaws in the raw materials or in the workmanship. No further claims may be made. The manufacturer doe s not guarantee Parts that are subject to wear and tear, and damage to and defects in the appliances or their parts, caused by: Chemical or physical influences from outside with regard to transport, storage, incorrect installation and use of appliance (e.g. cooling down with water, overheating). Use of inferior fuels incorrect operation. The manufacturer is not responsible for direct or indirect damage caused by the appliance. No claim can be laid to a full or partial exchange, unless the manufacturer is unable to fix the flaw or damage within a certain time span. Your Saey / Flandria device is guaranteed for two years against any manufacturing defect from the date of purchase provided that it is used according to the user s manual. The till slip or bill indicating the date substitutes for the guarantee. The scope of this guarantee is limited to the repair or replacement of parts that are discovered to be faulty during the course of normal use. This guarantee does not apply to malfunctions due to poor installation, incorrect use, modification of the device, dismantling of the device, wear and tear or lack or maintenance. Claims against guarantee must always be made at your point of sales. 14