Duct Temperature Sensors

Similar documents
Duct Humidity/Temp Sensor

Outside Air Humidity & Temperature Sensor

Room Humidity/Temp Sensor

Web-Enabled Thermostat IP-MT-101

AS570 Chill-Out Combination Sensor Installation and Operating Instructions

OM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.

TL-105 COLUMN HEATER

Potential Applications

Installation and Operating Guide Document No Vacuum Chambers Copyright 2017 Terra Universal Inc. All rights reserved.

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

User s Guide HHAQ-109. Portable Multi-gas Detector. Shop online at omega.com SM

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

CD6102 / CD6102 OC / CD6102-2

Duct Mount. Installation Instructions

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

Installation Guide

OSRAM 8/12/00 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

Inline Heater for Solvent or Gas. Installation and Operation Manual

SKORPION Process Air Heater

Quick-Start Operating Guide Document No Acrylic Vacuum Chambers Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

Ultrasonic Reflective Sensor

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

Quick-Start Operating Guide Document No Series 200 Glove Box Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010

User s Guide. Shop online at. Made in China. Two-wire Display and Control Unit

WATCHMAN Model LBW-WATCHMAN Ammonia Leak Detector

User s Guide. FLSW Series ROTAMETER WITH ALARM. Shop online at omega.com. For latest product manuals:

HIH-4602 A & C Series.

User s Guide. CN606 / 612 AC Series & CN606 / 612 DC Series CONTRONAUTICS INCORPORATED. Table of Contents.

Installation & Maintenance Instructions

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

Original instructions Sense7-series Non-contact coded safety switch

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

Max HT Air Heater FOR SAFETY & LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

Design Criteria. Installation

XT Series Thermostats

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

M7100 Pressure Transducer

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

Custom Products for Research. Kugelrohr Short Path Distillation

Installation Instructions / Warranty. Metris 31060XX XX XX1

GASGUARD LEL 3 OPERATING & INSTALLATION MANUAL

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Installation Instructions / Warranty. Starck 10111XX XX XX1

GASGUARD O 2. Oxygen Sensor OPERATING & INSTALLATION MANUAL

MaxLite LED MICRO-T PANEL

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

The Series LFII (TY3596) Residential

Installation & Maintenance Instructions

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Installation Instructions / Warranty

WDB2 Series Bearing Temperature Sensor

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Air Pump Up to 800 gallons

User s Guide TOTE SERIES. Wrap-Around Tote Tank Headers. TOTE SERIES Wrap-Around Tote Tank Heaters. Shop online at omega.com

BX Series. Installation, Operation, Maintenance Instructions & Spare Parts

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

INSTALLATION INSTRUCTIONS for PULSAR NS-Series Nav/Position or Nav/Position/Strobe Lights

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

Installation Instructions / Warranty

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ultrasonic Reflective Sensor

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

Original instructions JSNY7 Magnetic switch

Installation Instructions / Warranty

Electric Duct Heaters

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

GG-VL-R REFRIGERANT VENT LINE SENSOR. Installation and Operation Manual

Installation and Operations Manual

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Patent Pending invent for New Construction

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

PROOF BOX (All SD,DD, and TD 99 Models)

Hot Air Tool Air Heaters

Vanguard. Toxic & combustible gas detector

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

(HSTAT Series) Instruction Manual

GASGUARD VENT LINE3. Ammonia Sensor OPERATING & INSTALLATION MANUAL

LVCN-302 Set-Up Manual for Sump Model

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

For use with models: BP , BP , BP

Please Read and Save These Instructions.

GTS. User Manual. Gas-to-Steam Humidifier. Affix product label here.

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Installation Instructions PP-AS20 Anti-Scale System

Installation & Operation Manual

GETZ MANUFACTURING PART # CYLINDER DRYER

EQUIPMENT Operation Manual

EQUIPMENT Operation Manual

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-Factor General Description

Installation Instructions

OSRAM 1/25/01 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

Transcription:

Duct s Model TE-701 / 702 RoHS More than 16 types of interchangeable NTC thermistors, precision platinum, nickel or balco RTDs are available for universal compatibility. Five installation options probe with mounting flange or bulkhead fitting, plastic, galvanized steel, or NEMA-4 / IP- 65 steel enclosure offer the industry s most extensive range to satisfy all HVAC, appliance and industrial applications. 304 SS thin wall probe with a cold rolled hermitically sealed end forms a monolithic encapsulation cavity for the sensor and is immune to failures caused by high humidity, contamination, thermal shock and vibration. The flat probe end provides a large thermally sensitive area and the sensor is in direct thermal contact to this surface. As a result, extremely fast response is achieved to changes in temperature. Probe is attached to the enclosure or the flange using a patented process to provide a rugged, reliable and low profile attachment for ease of installation. TE 701/702 temperature sensors offer the industry s most extensive range of enclosure, installation and sensor types to satisfy all HVAC, industrial and commercial applications. These revolutionary sensors incorporate more than twenty five years of product development and experience drawn from millions of installations world wide in all types of applications. This product and process design combined with automated manufacturing processes yields a rugged, reliable, repeatable and stable temperature sensor at a low cost. The only line of temperature sensors offering lifetime warranty against moisture migration related failures. For large volume OEM customers, TE-701/702 temperature sensors are available in many custom configurations. Wire type, length or gage, terminals, connectors, probe lengths, enclosure options or sensor types may be customized based on volume. 8189 Century Boulevard Minneapolis, MN 55317-8002 USA 800-843-5116 952-556-4900 Fax 952-556-4997 sales@mamacsys.com www.mamacsys.com 4200 Waterside Centre Solihull Parkway Birmingham West Midlands B37 7YN United Kingdom 01384-271113 Fax 01384-271114 1 Fullerton Road #02-01 One Fullerton Singapore 049213 65-31581826 Fax 65-31581826 4 Armiger Court, Unit 2 Adelaide S.A. 5088 Australia 08-8395-4333 Fax 08-8395-4433 675 Cochrane Drive East Tower 6th Floor Toronto Ontario L3R 0B8 Canada 905-474-9215 Fax 905-474-0876

TE-701-A/B Flange Mount Incorporate a hermitically sealed 304 SS probe, crimped on to a Steel flange providing a rugged assembly for duct temperature sensing. Two mounting holes are provided for #8 screws and the flange mating surface is fully gasketted to seal off the probe and screw holes. TE-701-A is available with 3 in/75mm wire leads and the TE-701-B has 6 ft/1.8 meter plenum rated cable. TE-701-A/B is an ideal product for a rugged, reliable, quick and easy installation in air handlers, fan coil units, ducts, furnaces, freezers, ovens or any other through the wall temperature sensing application. TE-701-C/D Bulkhead Mount Fast response 304 SS probe with a brass bulkhead fitting and a compression sleeve forms a strong assembly for duct temperature sensing if adjustable insertion depth is desired. The bulkhead fitting is installed in the duct, compression sleeve loosened, probe inserted to the desired length and the sleeve is tightened. Sensor is available with 3 in/75mm leads or 6 ft/1.8 meter plenum rated cable. TE-701-C/D sensors provide a low cost, rugged, quick and easy installation in air handlers, fan coil units, ducts, plenum, furnaces, freezers, ovens or any other through the wall temperature sensing application which requires adjustable insertion length. TE-702-A Polycarb Enclosure Corrosion free 30% glass filled polycarbonate enclosure designed to withstand temperature extremes, mechanical shock and vibration. 304 SS probe crimp attached to the enclosure flange for a low profile mating surface, external mounting bracket to conform to irregular surfaces, single screw cover attachment, are some of the features which improve reliability and lower installation cost. TE-702-A temperature sensors provide a cost effective and reliable solution for air handlers, fan coil units, ducts, plenums, furnaces or any other application which does not require conduit wiring. 2

TE-702-B Galvanized Steel Enclosure Industry standard NEMA-1 / IP-30 galvanized sheet metal enclosure designed for all industrial and commercial duct temperature sensing applications. Hermitically sealed, fast response 304 SS probe crimp attached to the enclosure flange to provide a low profile mating surface, external mounting bracket to conform to uneven surfaces, keyed enclosure cover to swing open without removing the screws, 1/2 conduit opening, are some of the features which improve reliability and lower installation cost. TE-702-C Painted Steel Enclosure Rugged steel enclosure with welded seams, gasketted cover and powder coated finish, rated NEMA-4 / IP-65 for harsh environments. TE-702-C has all the other features including a 304 SS probe, external mounting bracket, conduit opening similar to the TE-702-B series except designed for applications in unconditioned environments where the unit may be subjected to dirt, condensation, oil vapor and other contaminants. SPECIFICATIONS: Platinum RTD sensors: +/- 0.1% @ 0 C, Alpha : 385 per DIN 43760 Nickel RTD sensors: (#2) +/- 0.5 C @ 0 C, 5000 PPM/K T.C.R. Nickel RTD sensors: (#4) +/- 0.5 F @ 70 F / 21.1 C, 6000 PPM/K T.C.R. Balco RTD sensors: +/- 0.5 F @ 70 F /21.1 C, 4300 PPM/K T.C.R. Thermistor sensors: +/- 0.2 C interchangeability @ 77 F/ 25 C Probe Material: 1/4 / 6.3mm O.D, 0.020 / 0.5mm wall 304 Stainless Steel Flange Material: Galvanized Steel Bulkhead Fitting: Brass with poly compression sleeve Plastic Enclosure: Polycarbonate 30% glass filled, rated UL 94V-5-0 Steel NEMA-1 / IP-30: 18 Ga. Galvanized Steel Steel NEMA-4 / IP-65: 18 Ga. Cold Rolled Steel, Baked on Enamel Operating Temp: -40F/-40C to 210F/100C Ambient Temp: -40F/-40C to 160F/70C Warranty: Five Years (Lifetime on Moisture Migration). U.S. PATENT NO. 6457857, 6555748, 7036224 3

TE-701-A/B TE-701-C/D 1/4" (6.3 mm) 1/4 (6.3 mm) 1.50" (37 mm) 2.00" (50 mm) 9/16 Hex TE-702-A TE-702-B/C 1/4" (6.3 mm) 1/4" (6.3 mm) O.D. 3.00" (75 mm) 2.50" (62 mm) 2.00" (50 mm) 4.00" (100 mm) 3.25" (80 mm) 2.50" (62 mm) 1.20" (30 mm) 2.50" (62 mm) 2.00" (50 mm) 4.00" (120 mm) 5.00" (125 mm) 4

ORDERING INFORMATION: TE-701 Installation Sensor* Probe Length A Flange mount 1 100 ohm Platinum RTD A 4 inches/100mm 3 in/175mm wire leads 2 1,000 ohm Nickel RTD (5000 PPM) B 6 inches/150mm B Flange mount 3 1,000 ohm Platinum RTD C 8 inches/200mm 6 ft/1.8m plenum cable 4 1,000 ohm Nickel RTD (6000 PPM) D 12 inches/300mm C Bulkhead mount 5 1,000 ohm Balco RTD 3 in/175mm wire leads 7 10,000 ohm NTC thermistor (Type III) D Bulkhead mount 8 10,000 ohm NTC thermistor (Carel) 6 ft/1.8m plenum cable 10 3,000 ohm NTC thermistor 12 10,000 ohm NTC thermistor (Type II) 13 5,000 ohm NTC thermistor 14 1,035 ohm Silicon PTC 15 100,000 ohm NTC thermistor 16 10,000 ohm NTC thermistor (Eliwell) 17 20,000 ohm NTC thermistor 18 2,252 ohm NTC thermistor 21 1,800 ohm NTC thermistor Example: TE-701-B-10-A: Flange mount with 6 ft cable, 3000 ohm thermistor and 4 inch probe length. ORDERING INFORMATION: TE-702 Installation Sensor* Probe Length A Polycarb Plastic 1 100 ohm Platinum RTD A 4 inches/100mm Enclosure IP-54 2 1,000 ohm Nickel RTD (5000 PPM) B 6 inches/150mm B Galvanized Steel 3 1,000 ohm Platinum RTD C 8 inches/200mm Enclosure NEMA-1 / IP-30 4 1,000 ohm Nickel RTD (6000 PPM) D 12 inches/300mm C Painted Steel 5 1,000 ohm Balco RTD Enclosure NEMA-4 / IP-65 7 10,000 ohm NTC thermistor (Type III) 8 10,000 ohm NTC thermistor (Carel) 10 3,000 ohm NTC thermistor 12 10,000 ohm NTC thermistor (Type II) 13 5,000 ohm NTC thermistor 14 1,035 ohm Silicon PTC 15 100,000 ohm NTC thermistor 16 10,000 ohm NTC thermistor (Eliwell) 17 20,000 ohm NTC thermistor 18 2,252 ohm NTC thermistor 21 1,800 ohm NTC thermistor Example: TE-702-A-3-D: Polycarb plastic enclosure with1000ohm Platinum RTD and12 inch probe length. * For sensor compatibility, please refer to TI.700-10. ** For a complete Resistance vs. Temperature tables, please refer to TI.700-11. 5

MAMAC Systems is the leading global manufacturer of sensors, transducers, control peripherals and web browser based IP appliances. MAMAC products are used for HVAC and environmental controls, remote monitoring, alarming, energy metering and industrial automation. All MAMAC products are manufactured in the USA. WARRANTY: MAMAC Systems, Inc. and its subsidiaries (hereinafter referred to as MAMAC Systems) warrants its products to be free of defects in material and workmanship for a period of five (5) years from date of shipment. If a unit is malfunctioning, it must be returned to the factory for evaluation. A return authorization number (RMA) will be issued by the customer service department and this number must be written or prominently displayed on the shipping boxes and all related documents. The defective part should be shipped freight pre-paid to the factory. Upon examination by MAMAC Systems, if the unit is found to be defective, it will be repaired or replaced at no charge to the customer. However, this warranty is void if the unit shows evidence of being tampered with, damaged during installation, misapplied, misused, or used in any other operating condition outside of the unit s published specifications. MAMAC Systems makes no other warranties or representations of any kind whatsoever, expressed or implied, except that of title. All implied warranties including any warranty of merchantability and fitness for a particular purpose are hereby disclaimed. User is responsible to determine suitability for intended use. LIMITATIONS OF LIABILITY: The remedies of buyer set forth herein are exclusive and the total liability of MAMAC Systems with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the product upon which liability is based. In no event shall MAMAC Systems be liable for consequential, incidental or special damages. MAMAC Systems reserves the right to change any specifications without notice to improve performance, reliability, or function of our products. Every precaution for accuracy has been taken in the preparation of this manual, however, MAMAC Systems neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages that result from the use of the product in accordance with the information contained in the manual. 8189 Century Boulevard Minneapolis, MN 55317-8002 USA 800-843-5116 952-556-4900 Fax 952-556-4997 sales@mamacsys.com www.mamacsys.com 4200 Waterside Centre Solihull Parkway Birmingham West Midlands B37 7YN United Kingdom 01384-271113 Fax 01384-271114 1 Fullerton Road #02-01 One Fullerton Singapore 049213 65-31581826 Fax 65-31581826 4 Armiger Court, Unit 2 Adelaide S.A. 5088 Australia 08-8395-4333 Fax 08-8395-4433 675 Cochrane Drive East Tower 6th Floor Toronto Ontario L3R 0B8 Canada 905-474-9215 Fax 905-474-0876