Instruction manual 640 Securiterre

Similar documents
Installation guide 864 MTT Multi Thermo sensor Thermometer

Instruction manual APU Hard alarm output contacts

Instruction manual ICU Hard alarm output contacts

Instruction manual SPU II Hard alarm output contacts

Installation Guide SmartRadar FlexLine

Installation, operation & service manual. AlarmScout 961/962 loop powered

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

OPTIBAR DP 7060 Supplementary Instructions

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli

Terminal Automation Solutions

OilSET-1000 (12 VDC)

MODEL A18 SOLVENT RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

GAN Electronic 750W/1000W DE EU

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

MANUAL Oil Level Sensor

E-Z Zone Pack 3+1 And 5+1 Boiler Manifold System

Safe Operation Manual. Honeywell IQ Force Gas Detector

Manual Power relay SR853

Installation, operation & service manual. AlarmScout 961/962 line powered

MODEL A5-2 SOLVENT & WATER RECOVERY SYSTEMS (EXPLOSION PROOF UNITS)

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

SET-2000 Hi Level/Oil

SET-2000 Oil/Sludge 12 VDC

Enraf Servo Gauge 854 XTG

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

SET Installation and Operating Instructions. Level switch for one sensor

KM300 Carbon Monoxide Detection System Installation Manual

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Intrinsically Safe Transmitters, Option Code 2n

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

Enraf Servo Gauge 854 ATG

EtherCAT Box Modules (EPxxxx-xxxx)

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

Terminal Automation Solutions

Earth-Rite II PLUS Static Earthing System

Dry Bath Heating Systems

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT FLR TYPE FLAMEPROOF RADIATORS

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

TRASCO ATEX Couplings

Operating Instructions Edition 11/2005. Process monitoring Ex-barrier for Diagnostics Unit SITRANS DA400 7MJ2010-1AA. sitrans

Intrinsically Safe or Explosionproof? Understanding the technology

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

With this symbol Gavita declares that this product complies with legal European requirements.

BLT-999W-2 Item # 60757

Alarm system For oil-water separator

FUNCTIONAL SAFETY MANUAL

ATEX 137. What it means for motor users

Portable Gas Detector Instruction Manual

IECEx Certificate of Conformity

ST1. Mod. USE AND MAINTENANCE MANUAL

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

ABS HOPPER LID SWITCH KIT ASSEMBLY

Functional safety manual Liquiphant M/S with FEL57 and Nivotester FTL325P

Service: to SLK Laboratory Hot Plates glass made of ideas

Operating Instructions for Rotor flow Indicator. Model: DKF

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

JASOPELS ROTATING FLESHING MACHINE 1-BEAM

Advance Optima Continuous Gas Analyzers AO2060-Caldos15, -Caldos17, -Magnos106, -Uras14 Category 2G Analyzer Modules

Int 937. Soldering Station. Instruction Manual. Correct Disposal of this product

SELECTION, INSTALLATION & TESTING OF ELECTRICAL EQUIPMENTS IN HAZARDOUS AREA

Materials Handling and Intralogistics. Industrial Trucks. In accordance with the Directive Equipment for potentially explosive atmospheres (ATEX)

User s Manual YTA610 and YTA710 NEPSI Certification

ATM Lighting sp. z o.o

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

OPTIWAVE X500 Supplementary Instructions

ANNEX GD-CERT-EX-EN SIT

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS EXHEAT INDUSTRIAL FLR & FLRA TYPE FLAMEPROOF RADIATORS

T7100D Microelectronic Conventional Thermostat

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

MANUAL Overflow sensor NVF-104/34-PF

OilMatic Pro / 230 V AC

CONTROL BE MADE CHANGES MAY NOT. Page 1

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

THE READY RACK 2 GEAR PPE DRYING CABINET. Operator s Manual & Installation Guide. Installation/Operation/Maintenance/Part Number I

Rosemount Pipe Clamp Sensor. Reference Manual , Rev BA February 2014

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

LS-JRE OPERATION & INSTRUCTION MANUAL

Instruction manual 878 Panel Indicator

Freightliner Refrigerator Troubleshooting Guide For (TJ18F) (TJ22F) (TJ18FP3)

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

OWNER'S MANUAL. FRY Holding Unit (FHU) MODELS FHU1 FHU2. Duke Manufacturing Company

Bona DCS70/Portable DCS Manual and safety instruction

TD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL SUPPLEMENT. TPM 005 Revision 0.0

DiscovR R134a Refrigerant Identifier

Fisher LCP100 Local Control Panel

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies

Buzzer Unit. TAN-5000 Series. Operating Manual

DICTATOR Hold-Open Systems for Hazardous Areas

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

50M Integrated Single or Two-Stage HSI Integrated Furnace Control Kit INSTALLATION INSTRUCTIONS

TAC Erie VL500. Application. Features. Zone Valve Control Center General Instructions

Transcription:

Instruction manual 640 Securiterre

Instruction manual 640 Securiterre April 2014 Part no. 4417571 Rev. 5 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701100 Fax : +31 15 2701111 E-mail : hfs-tac-support@honeywell.com Website : http://www.honeywellenraf.com Instruction manual 640 Securiterre Page 1

Copyright 2008-2014 Enraf B.V. All rights reserved Reproduction in any form without the prior consent of Enraf B.V. is not allowed. This manual is for information only. The contents, descriptions and specifications are subject to change without notice. Enraf B.V. accepts no responsibility for any errors that may appear in this manual. The warranty terms and conditions applicable in the country of purchase in respect to Enraf B.V. products are available from your supplier. Please retain them with your proof of purchase. Instruction manual 640 Securiterre Page 2

Preface This manual is intended for technicians involved in the commissioning and service of the Honeywell Enraf Series 640 Securiterre. A description preceding the technical procedures provides the technical information necessary to understand its functioning. It is recommended to read this description prior to performing any procedures. For installation of the 640 Securiterre, please refer to the Installation guide of the 640 Securiterre. This manual solely describes the commissioning and service of the basic Securiterre. Legal aspects Safe execution of the procedures described in this manual requires technical skill in the handling of tools and knowledge of safety regulations for working in hazardous areas. The information in this manual is the copyright of Enraf B.V., Netherlands. Enraf B.V. disclaims any responsibility for personal injury or damage to equipment caused by: - Deviation from any of the prescribed procedures - Execution of activities that are not prescribed - Neglect of the safety regulations for handling tools and use of electricity EC declaration of conformity Refer to the declaration of conformity shipped with the instrument Additional information Please do not hesitate to contact Honeywell Enraf or its representative if you require any additional information. Instruction manual 640 Securiterre Page 3

1 Introduction Electrostatic charge can be generated and accumulated during product movement, filtering and loading of tank compartments with non-conducting liquids such as petroleum products and chemicals. As a result, the tank obtains a different potential than the loading equipment. This can lead to sparking when for example the loading arm is brought in, igniting the product vapors. This also applies for movement of powders (barrel version) The model 640 Securiterre is a grounding system for loading gantries that offers improved safety during the transfer of flammable liquids or powders see above. It ensures that reliable grounding has been achieved before any product transfer takes place. It is an indispensable item for every loading facility of flammable non-conducting liquids and powders. 1.1 Principle of operation The measuring circuit of the Securiterre consists of a low power, intrinsically safe digital signal processor that detects the presence of a specific load at the end of the ground clamp. The Securiterre as such can be used for the grounding of trucks, trains or barrels. The impedance of the load (its resistance and capacitance) is measured by the DSP circuit and does not require any tuning. Internal jumpers allow the specific configuration of the operating range to the specific intended application; either truck, train or barrel. Note: Please note that the device can only be used in one predefined application. The device has been configured to your specific requirements in the Honeywell Enraf factory! 1.2 Configurations Truck version The Securiterre type: UAT*640CAA* or UAT*640DAA*, designed specifically for the grounding of trucks, provides a direct earth connection for the carrier. When not mounted the circuit is grounded via a large resistance to reduce the hazard of sparking. Only after connecting the earth clamp to the truck a double check is executed, based on the measured capacitance and resistance. After verification of both values a relay will connect the measuring circuit directly to ground. Another relay switches the signal LEDs to green and switches an extra contact to externally mounted equipment. There are two versions: UAT*640CAA* this version has a coiled cable connected to the grounding clamp UAT*640DAA* this is an optional version with a reel (Securistore) connected to the grounding clamp Refer to Figures 1.1 and 1.2 Figure 1.1 Truck version with coiled cable Instruction manual 640 Securiterre Page 4

Figure 1.2 Truck version with Securistore (optional) The Truck version of the Securiterre is provided with a so called: Quick Break Release. If the truck driver accidently forgets to disconnect the earth clamp and drives away, the clamp releases from the cable, which prevents damaging the cable. In this case, just plug in a spare clamp. If the impedance cannot be measured, in case of a low resistance or a too small capacitance, a magnetically operated bypass can be activated to establish the initial grounding. Please see section 3.2 for proper operation procedures. Train version The Securiterre type: UAW*640CAA* or UAW*640DAA*, designed for the grounding of train wagons, provides a direct earth connection for the carrier. As such it assumes a loop resistance in the circuit loading rack-securiterrecarrier-rail-earth. After verification of the maximum resistance to the ground a relay will connect the measuring circuit directly to ground. Another relay switches the signal LEDs to green and switches an extra contact to externally mounted equipment. There are two versions: UAW*640CAA* this version has a coiled cable connected to the grounding clamp UAW*640DAA* this is an optional version with a reel (Securistore) connected to the grounding clamp Refer to Figures 1.3 and 1.4 Figure 1.3 Train wagon version with coiled cable Instruction manual 640 Securiterre Page 5

Figure 1.4 Train wagon version with Securistore (optional) Barrel version The Securiterre type: UAB*640CAA*, designed for the grounding of barrels and drums, provides a direct earth connection for the carrier. For this purpose a special clamp is used which has two poles connected to the barrel or drum. After verification of the maximum resistance between the two poles in the clamp, a relay will connect the measuring circuit to ground. Another relay switches the signal LEDs to green and switches an extra contact to externally mounted equipment. Refer to figure 1.5. Figure 1.5 Barrel version 1.3 Approvals (ATEX) The Honeywell Enraf 640 Securiterre is an explosion proof instrument, which is designed to meet requirements of ATEX. Instruction manual 640 Securiterre Page 6

2 Safety 2.1 Safety aspects of the 640 Securiterre Warning Do not use the instrument for anything else than its intended purpose. Do not deviate from described procedures The housing of the 640 Securiterre is explosion proof and complies with European ATEX standards which include EN 50.014, EN 50.018, EN 50.020, EN13463 and EN50281-1-1 and is certified as: II 2 (1)/1 G D Ex d [ia] ia IIC T6 Ex td A21 T85 C IP6X LCIE 05 ATEX 6001 X The cover of the Securiterre is removable for installation and modification purposes. However please remind that the device has already been programmed to your specific application. Caution The Securiterre is an explosion proof instrument with an intrinsically safe circuit. Modifications to the instrument may only be carried out by trained personnel, who are authorized by Honeywell Enraf. Failure to adhere to this will invalidate the approval certificates. 2.2 Personal safety The technician must have basic technical skills to be able to safely install the equipment. When the Securiterre is installed in a hazardous area, the technician must work in accordance with the (local) requirements for electrical equipment in hazardous areas. Warning In hazardous areas it is compulsory to use personal protection and safety gear such as: hard hat, fireresistant overall, safety shoes, safety glasses and working gloves. Avoid possible generation of static electricity. Use non-sparking tools and explosion-proof testers Make sure no dangerous quantities of combustible gas mixtures are present in the working area. Never start working before all parties have signed the work permit. Pay attention to the kind of product in the area. If any danger for health exists, wear a gasmask and take all necessary precautions. 2.3 Safety conventions Warnings, Cautions, and Notes are used throughout this manual to bring special matters to the immediate attention of the reader. - A Warning concerns danger to the safety of the technician or user - A Caution draws attention to an action which may damage the equipment - A Note points out a statement deserving more emphasis than the general text, but not requiring a Warning or Caution. Instruction manual 640 Securiterre Page 7

3 Commissioning The specific settings of jumper S1 and S2 define the application, respectively truck, train or barrel, of your Securiterre 640. The Securiterre can as such be (re)configured to your specific needs (please adhere earlier warning and caution notes). These jumpers are located in the top of the main board between the three optocouplers (U8, U9 and U10) and the connector JP4, see figure 3.1. The specific settings for jumper S1 and S2 associated with the Securiterre types UAT*640CAA*/UAT*640DAA*(Truck), UAW*640CAA*/UAW*640DAA*(Train wagon) and UAB*640CAA* (Barrel) are represented in table 3.2. U8 S6 S2 S1 3 2 1 3 2 1 3 2 1 JP4 U9 U10 Figure 3.1 Function/Jumper S1 S2 Truck 2-3 2-3 Train wagon 2-3 1-2 Barrel 1-2 2-3 Table 3.2 Note: S1 position 1-2 means that a jumper is inserted between positions 1 and 2 of S1. Note: The jumper settings have already been adjusted to your specific application in the factory Caution Each version, Truck, Train wagon and Barrel, has its own type of clamp. Hence, when changing the S1 and S2 jumper setting, one must also change the type of clamp on the cable and check/alter the wiring connection (refer to installation guide). Instruction manual 640 Securiterre Page 8

3.1 Checks before starting the application Before any power is applied to the Securiterre 640 check the following: - verify jumper settings for the intended application - verify power fuse and check for label indicating the rated voltage - check for clean wiring, especially between IS and non-is wires - check that all ground connections are made - check that non-used cable inlets are sealed with appropriate blind plugs - close all covers - place clamp in rest position / rest plug - apply power and check whether the red LEDs light as should be Note: Note: Yellow and Red LEDs lighting simultaneously indicates internal auto-test failure: The Securiterre may work but needs repair. Green and Red LEDs lighting simultaneously indicates poor internal relay contact grounding: The Securiterre is unusable and needs repair. 3.2 Proposed procedures Trucks - Place the earth clamp on the clamp holder to start calibration. The LEDs will light up yellow when the calibration process is finished. - Connect the earth clamp to the earth point of the truck, the LED indication should instantly turn to yellow and then to green indicating a safe situation. If the red LEDs remain activated check the clamp for good connection. - When the green LEDs indicate a safe situation other secondary connections, such as overfill alarms, filling attachments, etc., can be connected to the truck. - After loading first disconnect the secondary connections such as overfill alarms, filling attachments, etc. - Then remove the earth clamp and place this back on the clamp holder. Note: The Return point is a brass pin intended to calibrate the clamp. The user should place the clamp on this pin when the clamp is not connected to the truck. Note: To achieve correct grounding conditions the cable clamp must be properly connected. If there is no release after few seconds (red LEDs are on), check the earth connection which should be clean and free from corrosion. Magnetic override Highly sensitive, the Securiterre device will detect even small changes in grounding properties as a result of weather conditions, loading equipment or any other grounding sources that do not impact safety and in rare cases prevent the system switching to green. If, after double checking the grounding, the release remains blocked, the magnetic override can be used to reset the alarm as following: - Connect the earth clamp to the earth point of the truck, the LED indication in this case should remain red. - Briefly place the brine magnet on the red dot located on the top side of the Securiterre, see figure 3.3 below. The instrument should now respond within a couple of seconds indicating successful grounding, do not remove the clamp during use of the brine magnet. Remove the magnet after successful grounding. - Secondary connections, such as overfill alarms, filling attachments, etc., can now be connected to the truck. - After filling first disconnect the secondary connections such as overfill alarms, filling attachments, etc. - Then remove the earth clamp and place this back on the clamp holder. Caution Forced truck grounding requires a careful assessment of the situation. Please check the Securiterre and truck for anomalies; e.g. missing or broken clamp, cut cable, etc. Instruction manual 640 Securiterre Page 9

Warning In case of brine magnet in place; do not remove the clamp from the truck at all times! Figure 3.3 Trains Connect the earth clamp to the earth point of the train, the LED indication should instantly turn to orange and then to green indicating a safe situation. If the red LEDs remain activated check the clamp for good connection. - When the green LEDs indicate a safe situation other secondary connections, such as overfill alarms, filling attachments, etc., can be connected to the train. - After filling first disconnect the secondary connections such as overfill alarms, filling attachments, etc. - Then remove the earth clamp and place this back on the clamp holder. Note: To achieve correct grounding conditions the cable clamp must be properly connected. If there is no release after a few seconds (red LEDs are on), check the earth connection which should be clean and free from corrosion. Use of brine-magnet is not possible. Barrels Connect the earth clamp to the earth point of the barrel, the LED indication should instantly turn to yellow and then to green indicating a safe situation. If the red LEDs remain activated check the clamp for good connection. - When the green LEDs indicate a safe situation other secondary connections, such as filling attachments, etc., can be connected to the barrel. - After filling first disconnect the secondary connections such as filling attachments, etc. - Then remove the earth clamp and place this back on the clamp holder. Note: To achieve correct grounding conditions the cable clamp must be properly connected. If there is no release after a few seconds (red LEDs are on), check the earth connection which should be clean and free from corrosion. Use of brine-magnet is not possible. Instruction manual 640 Securiterre Page 10

4 Service and Troubleshooting The 640 Securiterre does not require preventive maintenance. The instrument has been adjusted in the factory and is carefully tested before shipping. Hence installation without any adjustments is possible after receipt of the instrument. For mechanical and electrical installation details, please refer to the installation guide of the Securiterre 640. Instruction manual 640 Securiterre Page 11

Appendix A Dimensional drawings Instruction manual 640 Securiterre Page 12

Appendix B Spare Parts Part Function Part number Main Board CPU circuits S0640601 Display Board Led display S0640602 Rest Position Plug Metal part S0640102 Coiled Cable + Clamp (Train wagon version) Connection S0640103 Coiled Cable + Clamp (Truck version) Connection S1640872 Coiled Cable + Clamp (Barrel version) Connection S1640892 Clamp (Truck version) Connection S0640104 Brine Magnet Manual override A0186236 Fuses Set Control power surges S0640901 Related publications - Installation guide Securiterre 640 - Brochure Load automation systems, for safety and precision - Safety instructions Instruction manual 640 Securiterre Page 13