LiqTec, V GRUNDFOS INSTRUCTIONS

Similar documents
Comfort Series Instant Hot Water System

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

GRUNDFOS INSTRUCTIONS CMBE. Installation and operating instructions. Drinking Water System Component NSF / ANSI 61 NSF / ANSI 372

GRUNDFOS INSTRUCTIONS UPZCP-3, 4, 6. Multi-zone pump control. Installation and operating instructions

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

GRUNDFOS INSTRUCTIONS MAGNA1. Installation and operating instructions

TYPE LF/LC/LCV END SUCTION PUMPS

Installation Manual. Expansion Module 0100 Version 1.0 EXP HBX Control Systems Inc.

EQUIPMENT Operation Manual

IMPORTANT. World-wide Patents. VIGIA is a trademark of Col-Ven S.A.

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

E C O L O G I C A L C O O L E R S INTELLIGENT

INSTALLATION, OPERATION AND MAINTENANCE

BACKUP BATTERY INSTALLATION INSTRUCTIONS

M1200 Series Limited Warranty Dependability Promise

Sentry LIQUID LEVEL GAUGE MODEL 200 or 200C OWNER MANUAL REV 1.7 SEPT08 PAGE 1 OF 12

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

1500 Watt OIL FILLER RADIATOR INSTRUCTION MANUAL. pure indoor living MODEL BOF2001-CN

THARRINGTON OIL FIRED ROOM HEATERS MODELS 5135, 5160, R35, 10R60, 13R75 FEATURES SAFETY NOTICE

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

Washable HEPA Air Cleaner with PlasmaWave Technology

EQUIPMENT Operation Manual

SWF2000-CN twin TRUSTED FOR OVER 100 YEARS. Window Fan. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Thermostat Remote Control & Receiver

SFH136-CN TRUSTED FOR OVER 100 YEARS. Sunbeam Heater. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Viessmann B1HA Boiler Series

Projection Alarm Clock USER GUIDE

Instruction Leaflet. Read instructions before operating. Retain for future reference.

Panel Mounted Heat Exchangers by Dantherm, Inc.

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL

BIONAIRE HEATER. Instruction Leaflet. pure indoor living MODEL: BCH4130. Read instructions before operating. Retain for future reference.

Expanded Backup Control Installation & Operator s Instruction Manual

ELECTRONIC COMMUNICATING THERMOSTAT COOL AUTO. Hold Prog Mode Fan. Owner's Manual. RC-120 Two Stage Heat/Cool 2 Stage Heat / 2 Stage Cool

TrueClean ToteCleaner

THE BOARD 100IB / 200IB HOME IRONING BOARD INSTRUCTION MANUAL

Duct Mount. Installation Instructions

2-Port alarmcharge Hub - Manual

ELECTRONIC COMMUNICATING THERMOSTAT : P COOL AUTO. Owner's Manual

D E S I G N G U I D E REVISED 10 / 2017

Retro Flip Alarm Clock MODEL: CH1200/1/2

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model COSTAR 24VC-e Single Relay

D E S I G N G U I D E REVISED 9 / 2018

Securitron. Switching Power Supplies

GRUNDFOS PLUMBING & HVAC PRODUCTS

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad

GRUNDFOS PRODUCT GUIDE MAGNA. UPE Series 2000 circulator pumps

Models LBW-420-LEL (24 VDC powered) Ammonia Leak Detector

GG-EM ENTRANCE MONITOR. Installation and Operation Manual


ELECTRONIC COMMUNICATING THERMOSTAT

20 High velocity Air

GRUNDFOS DATA BOOKLET SLC, DLC. Pump controllers

OWNER S MANUAL FOR MODELS DXA (Air-Automatic) DXM (Manual/Non-Air) DXH (Hydraulic Automatic) DXE (Electrical Mechanical Automatic)

DECORATIVE GAS LOG PLACEMENT INSTRUCTIONS

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

MORE DEMAND. than a pump. grundfos MAGNA3

Model 9001, Alarm

PSW112 Owners Manual. Platinum Series Subwoofer. Models. PSW112 Powered Subwoofer

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Model 65 Humidifier Control Owner s Manual

OIL FREE HEATER RADIATEUR SANS HUILE CALEFACTOR SIN ACEITE AQUECEDOR SEM ÓLEO

User's Guide. Pinless Moisture Meter. Model MO257

Operation Manual Vortex mixer unitexer 1

Operating Manual. PRO 1000 Series EFS-01. Non-Programmable Thermostat

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

Features & Benefits. Description. Example of LCD display screen. Functionality. Ordering Information: Model 7600 Boiler Control

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

OM-CP-Cryo-Temp Ultra Low Temperature Data Logger. Shop online at. omega.com For latest product manuals: omegamanual.

TH146-P-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

Operating Instructions READ AND SAVE THESE INSTRUCTIONS

TQ Series. Electronic Control Pump Instruction Manual. 50Hz. ISO 9001 Certified Walrus Pump Co., Ltd.

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Instruction Leaflet 99.97% TRUE HEPA AIR PURIFIER. pure indoor living MODEL: BAP925-CN. Replacement filters: A1230H and A1260C

Warranty. Thanks. Thank you for purchasing the Oliso Smart Iron, a safer, smarter way to iron.

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

TrueClean ToteCleaner

Owner s Manual. PIR-1 IR Learner

INSTALLATION AND OPERATING INSTRUCTIONS FOR Built-in units Blt-in-38, Blt-in-58, Blt-in-36 & Blt-in-62

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

Static Pressure Control

4000IS PROFESSIONAL IRONING SYSTEM INSTRUCTION MANUAL

Instruction Leaflet. Heater with Adjustable Thermostat PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

5+2 Day. up to HEAT COOL

Low Temperature Stainless Steel Panel Series Installation and Commissioning Guide

Henny Penny Blast Chiller/Freezer Models BCC/BCR-140 Models BCC/BCR-175 Models BFR/BCR-350

Installation and Operations Manual

Owner s Manual. 5+2 Day Programmable Digital Thermostat

Sound Cover [ , , , ]

FOR EASY, FAST INSTALLATION AND FOR RESULTS

MCD. Corona Discharge Ozone Generators MANUFACTURED BY Bullock Lane San Luis Obispo, CA

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater


ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Model TWBS.SHE Tempered Water Blending System

Model 9201EFE Tempered Water Blending System

CALIBRATABLE 3-FUNCTION THERMO- HYGROMETER USER S MANUAL

Transcription:

GRUNDFOS INSTRUCTIONS LiqTec, 80-130 V Installation and operating instructions Notice d installation et d entretien Instrucciones de instalación y funcionamiento

LIMITED WARRANTY Products manufactured by GRUNDFOS PUMPS CORPORATION (Grundfos) are warranted to the original user only to be free of defects in material and workmanship for a period of 24 months from date of installation, but not more than 30 months from date of manufacture. Grundfos liability under this warranty shall be limited to repairing or replacing at Grundfos option, without charge, F.O.B. Grundfos factory or authorized service station, any product of Grundfos manufacture. Grundfos will not be liable for any costs of removal, installation, transportation, or any other charges which may arise in connection with a warranty claim. Products which are sold but not manufactured by Grundfos are subject to the warranty provided by the manufacturer of said products and not by Grundfos warranty. Grundfos will not be liable for damage or wear to products caused by abnormal operating conditions, accident, abuse, misuse, unauthorized alteration or repair, or if the product was not installed in accordance with Grundfos printed installation and operating instructions. To obtain service under this warranty, the defective product must be returned to the distributor or dealer of Grundfos products from which it was purchased together with proof of purchase and installation date, failure date, and supporting installation data. Unless otherwise provided, the distributor or dealer will contact Grundfos or an authorized service station for instructions. Any defective product to be returned to Grundfos or a service station must be sent freight prepaid; documentation supporting the warranty claim and/or a Return Material Authorization must be included if so instructed. GRUNDFOS WILL NOT BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSSES, OR EXPENSES ARISING FROM INSTALLATION, USE, OR ANY OTHER CAUSES. THERE ARE NO EXPRESS OR IMPLIED WARRANTIES, INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH EXTEND BEYOND THOSE WARRANTIES DESCRIBED OR REFERRED TO ABOVE. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages and some jurisdictions do not allow limit actions on how long implied warranties may last. Therefore, the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from jurisdiction to jurisdiction.

LiqTec, 80-130 V Installation and operating instructions Page 4 Notice d installation et d entretien Page 6 Instrucciones de instalación y funcionamiento Pág. 9 3

Description The LiqTec protects the pump against dry-running. protects the pump against too high liquid temperature 266 F ±9 F (130 C ±5 C). can monitor the motor temperature if the PTC sensor in the motor has been connected. has a fail-safe design. If the sensor, sensor cable, electronic unit or power supply fails, the pump stops immediately. Functions 12 11 1 2 3 4 10 1. Connection for dry-running sensor Service number of dry-running sensor: 96556427. 2. Connection for external restarting. 3. Motor PTC Green light indicates OK or short-circuited terminals. Red light indicates too high motor temperature. The alarm relay is activated. 4. Connection for PTC sensor A PTC sensor according to DIN 44 082 can be connected to this terminal. If the PTC sensor is not used, the terminals must be short-circuited. 5. Sensor indicator light Red light indicates defective sensor or cable. The alarm relay is activated. 6. Deactivation of the dry-running monitoring function Press the button to deactivate the dry-running monitoring function. Red flashing light. The PTC monitoring function is still active. Press the Restart button to reactivate the dry-running monitoring function. 9 8 5 6 7 TM03 0129 4104 Mounting the LiqTec sensor The LiqTec can be fitted to a DIN rail to be incorporated in a control cabinet. See illustrations on page 12. Electrical connection Example of electrical connection, see page 13. Calibration of sensor and LiqTec Follow the procedure on the next page. 7. High liquid temperature indicator light Red light indicates too high liquid temperature 266 F ±9 F (130 C ±5 C). The alarm relay is activated. 8. Supply voltage 80-130 V, 50/60 Hz. 9. Dry-running indicator light Green light indicates OK (liquid in pump). Red light indicates dry running (no liquid in pump). The alarm relay is activated. 10. Alarm/Run relay output Potential-free changeover contact. Maximum contact load: 250 V, 1 A, AC (inductive load). 11. Auto/Man Changeover between automatic and manual restarting. The default setting is Man. Changeover is carried out by means of a small screwdriver. When Auto has been selected, the alarm indication will automatically be reset 10 to 20 seconds after liquid detection. 12. Restart Press the button to restart the pump. The button has no influence on the PTC monitoring. 4

Calibration of sensor and LiqTec Step Action Result 1 2 3 4 Check that the sensor is correctly connected to the LiqTec, see page 13. Before fitting the sensor in the pump, submerge the sensor into stagnant water. Any kind of container with water can be used. Note: It is important that the water is stagnant as the calibration will be misleading if the sensor is cooled by flowing water. Keep the buttons, pos. 6 and 12, pressed for approx. 20 seconds. When the green indicator lights, pos. 3 and 9, are constantly on, stop pressing the buttons, pos. 6 and 12. All red indicator lights (except pos. 7) start flashing. The calibration is completed. Further information Information related to IEC 60 730-1: Software class A. Pollution degree 2. Type 1. The LiqTec has been curus approved according to UL 508. Maximum pressure: 580 psi (40 bar). Maximum liquid temperature: +266 F ±9 F (+130 C ±5 C). Maximum ambient temperature: +131 F (+55 C). Power consumption: 5 Watt. Enclosure class: IP X0. Disposal Disposal of this product or parts of it must be carried out according to the following guidelines: 1. Use the local public or private waste collection service. 2. In case such waste collection service does not exist or cannot handle the materials used in the product, please deliver the product or any hazardous materials from it to your nearest Grundfos company or service workshop. Maximum cable length: 65.6 feet (20 m). Standard cable: 16.4 feet (5 m). Extension cable: 49.2 feet (15 m). Product number: 96443676. Subject to alterations. 5

TM03 0092 4004 OFF ON TM02 2175 3801 TM02 2176 3801 TM03 0093 4004 TM03 0094 4004 TM03 0095 4004 TM03 0096 4004 OFF ON TM03 0097 4004 TM02 2182 3801 12

L1 L2 L3 N Sensor K1 External restart T+ T+ T+ M 3 Brown/Black Blue White K1 TM03 0130 4104 13

U.S.A. GRUNDFOS Pumps Corporation 17100 West 118th Terrace Olathe, Kansas 66061 Phone: +1-913-227-3400 Telefax: +1-913-227-3500 Canada GRUNDFOS Canada Inc. 2941 Brighton Road Oakville, Ontario L6H 6C9 Phone: +1-905 829 9533 Telefax: +1-905 829 9512 Mexico Bombas GRUNDFOS de Mexico S.A. de C.V. Boulevard TLC No. 15 Parque Industrial Stiva Aeropuerto Apodaca, N.L. 66600 Mexico Phone: +52-81-8144 4000 Telefax: +52-81-8144 4010 Addresses revised 18.04.2002

Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence 96562443 0105 61 www.grundfos.com