TDB3105 Terreon 36" Circular, 7-1/2" Deep Bowl Washfountain

Similar documents
TDB3104. Terreon 54" Semi-Circular, Deep Bowl Washfountain

WF3204. Extra Height 54" Terreon Semi-Circular Washfountain. Specifications

WF2613 Classic Corner Washfountain with 9" Deep Bowl

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

SS-3N Express Lavatory System SS-Series

SN2013, SN2033 Sentry Corner Shallow Bowl Washfountains

SN2005, SN2008 Sentry Circular Shallow Bowl Washfountain

FL-2H, FL-2L Frequency Lavatory System FL-Series

SN2003, SN2023, SN2004, SN2024 Sentry Semi-Circular Shallow Bowl Washfountain

WF2613 Classic Corner Washfountain with 9" Deep Bowl

AV30 Advocate Lavatory System AV-Series

WF2503, WF2504, WF2505, WF2508 Terreon Classic Washfountains

SS-1N Express Lavatory System SS-Series

AV60 Advocate Lavatory System AV-Series

SN2003, SN2023, SN2004, SN2024

Express Lavatory System SS-Series

LD-5010 OmniDeck with WashBar 5000 Series

SS-2N Express Lavatory System SS-Series

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

AV60 Advocate Lavatory System AV-Series

AV90 Advocate Lavatory System AV-Series

FL-1H, FL-1L Frequency Lavatory System FL-Series

WF2603, WF2604, WF2605, WF2608 Terrazzo Classic Washfountains

WF Model Classic Washfountains Pre-Assembled Semi-Circular and Circular with 9" Deep Bowl

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

DISCONTINUED. LA75 Advocate Lavatory System LA-Series. Specifications. Code Compliance and Certifications. Construction

WF2803, WF2804, WF2805, WF2808 Bradstone Classic Washfountains

Express Lavatory System MG-Series

Express Lavatory System MG-Series

FL-3H, FL-3L Frequency Lavatory System FL-Series

AV60 Advocate Lavatory System AV-Series

BRADLEY CORPORATION WASH FOUNTAINS Page 1 of 8

Washfountain Application Guide

Installation. SS-2N TouchTime (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Installation. SS-3N Infrared (Standard and Wall-Hung) Table of Contents. Express Lavatory System SS-Series

Installation TDB3104 WF3204. Table of Contents. Terreon 54" Semi-Circular Deep Bowl Washfountain with TouchTime

For Service Only. Installation Instructions EXD-2/STD EXD-2/JUV. Express Deck Lavatory System EXD Series

For Service Only. Installation Instructions SS-3/IR/WH97. Express Lavatory System SS-Series

Model Z TAS. Standards Compliance. Sundara Drift Double Basin Hand Washing System

For Service Only. Installation Instructions. SS-3/AZ/WH97 Express Lavatory System SS-Series

Installation TDB3103 WF3203. Table of Contents. Terreon 36" Semi-circular Deep Bowl Washfountain with TouchTime Control

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

LVSD2 Verge Wash Basin LVS-Series

LVQD3 Verge with WashBar Technology LVQ-Series

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

For Service Only. Installation Instructions EXD-3/WH97. Express Deck Lavatory System EXD Series

Installation Instructions OBSOLETE

LVSD2 Verge Wash Basin LVS-Series

Installation TDB3105 IMPORTANT! Table of Contents. Terreon 36" Circular Deep Bowl Washfountain with Infrared Control

LVQD3 Verge with WashBar Technology LVQ-Series

Terreon WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

School Solutions Ideabook

LVQD1 Verge with WashBar Technology LVQ-Series

Installation Instructions

Installation. MG-2 TouchTime. Express Lavatory System - MG Series with TouchTime Metering. Table of Contents

Installation MG-2/IR. Express Lavatory System - MG Series with Adaptive Infrared Control. Table of Contents

LC500. Patient Care Unit, 29", Fixed Water Closet. Specifi cations Standard Equipment

LA45 DISCONTINUED IMPORTANT!

Model Z Sundara Reef Triple Basin Hand Washing System

Installation Instructions

Installation SS-3N/IR/STD SS-3N/IR-WH. Express Lavatory System SS-Series. Table of Contents

WAW-2311 WAW-2322 WAW SERIES LAVATORIES

WARNING. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi.

TABLE OF CONTENTS. BARIATRIC SINKS & TOILETS Specially engineered fixtures designed to withstand loads typical in bariatric care environments.

PAT BASIN MODEL 9121, 9131, & 9141

LA90 DISCONTINUED IMPORTANT!

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

LA60 DISCONTINUED IMPORTANT!

DISCONTINUED. Installation. SS-2N/ndt/STD SS-2N/ndt/WH. Express Lavatory System SS-Series. Table of Contents

? Teflon Tape? 9/16 Fixture Wall Anchors and. ? 9/32 Fixture Wall Anchors and

HL45, HL80 Thermostatic High-Low Valves

Installation Instructions

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

Terreon Lav Decks WARNING

Model Z Sundara Float Double Basin Hand Washing System

Installation Instructions

BRADLEY HALO EMERGENCY PLUMBING FIXTURES

Installation Instructions

BRADLEY HALO EMERGENCY PLUMBING FIXTURES (Short Form Version)

Installation Instructions

MERIDIAN MODEL# 3793

Installation Instructions

Installation LVRD1 IMPORTANT! Verge Lavatory System LVRD-Series with Evero Natural Quartz Material. Table of Contents

LVRD3. Verge Lavatory System LVRD-Series with Evero Natural Quartz Material WARNING

Durability within reach

1a Installing Optional Soap Dispenser for A/O Drain Units. A Place the upper tie bar on top of the. B Insert the tie rod assembly through the

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

Commercial washroom innovation. 90 years as the leading source of innovative solutions for all washroom design challenges. bradleycorp.

A. All fixtures shall meet the requirements of ANSI A117.1, ANSI Z124.2 and the State of Texas Accessibility Standards (TAS).

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

Ligature Resistant Sensor Faucet Patent # US D635,386 #SAL-5011/SF370

A. Section Joint Sealants: Seal fixtures to walls and floors.

Installation LVSD2. Table of Contents. Verge Lavatory System LVS-Series with Evero Natural Quartz Material

S19361HF - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

BRADLEY CORPORATION DOMESTIC WATER PIPING SPECIALTIES Page 1 of 9

Partitions. Accessories. Lockers. No-Touch Washroom Accessories

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

Ligature Resistant. ADA Compliant

Transcription:

cupc Certified ADA and TAS Compliant Suitable for Heavy Duty Hand Washing Reliable Air, TouchTime or Infrared Vandal Resistant Easy to Clean Three Different s (Including Juvenile and Intermediate s) Specifications Size and Capacity Accommodates up to five users at a time, using less water, energy and space than lavs equipped with conventional faucets. The Classic Sprayhead (non-sectional) is controlled by an infrared sensor, electronic pushbutton or piezo switch or air activated pushbutton. The operating range is 20-80 PSI. Construction Bowl Materials Constructed of Terreon, a densified solid surface material composed of bio-based resin, or Terreon RE, a densified solid surface material composed of a bio-based resin and preconsumer recycled granules. Terreon and TerreonRE are resistant to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit abrasives. Terreon and TerreonRE are Home Innovation Lab certified to meet CSA B45.5/ IAPMO Z124. Terreon and TerreonRE are GREENGUARD certified as low-emitting materials. Trap Enclosure/Pedestal The elliptical, tapered pedestal is fabricated from reinforced, gel-coated fiberglass with a stainless steel trim piece or kick plate to prevent damage. A large access panel is provided for ease of installation and maintenance. Vandal Resistance The infrared sensors, pushbuttons or switches are secured to the unit from inside a heavy gauge stainless steel module to prevent tampering. If a vandal attempts to trigger constant operation by covering the sensor or placing a stationary object in the sensor s detection area, the adaptive infrared sensor will automatically shut off the water flow after 30 seconds. All valves, water supplies and waste connections are concealed inside the pedestal/trap enclosure. The Terreon and TerreonRE bowls are resistant to stains, burns and impact; surface damage is easily repaired and repair work is virtually undetectable. Standard Equipment Valves and Fittings In addition to the bowl and pedestal, the following valves and fittings are standard: sprayhead with stainless steel support tube and bowl gasket; drain and tailpiece with strainer; sprayhead supply tubing; Navigator thermostatic mixing valve; flexible stainless steel supply hoses; stops, and adjustable volume control valve. Activation Controls Infrared Hands placed within the bowl are detected by an infrared sensor module which activates a flow of tempered water from the classic non-sectional sprayhead. Shut-off is automatic after hands are removed from the detection area. The infrared sensor uses a conicalshaped transmitting beam, having a detection area adapted to, but not exceeding, the bowl perimeter. The infrared sensor automatically adapts to the bowl after power is turned on. The infrared sensor is not affected by varying color tones or darkness. Direct sunlight or bright washroom lights will not activate the system. Infrared models also include solenoid valves and a 12V plug-in adapter as standard equipment: Solenoid 12VDC, 3/8" NPT. Few moving parts, and resistant to most chemicals, minerals, and impurities often present in municipal water supplies. Low-Voltage Adapter A UL/CSA listed 120VAC/12VDC plug-in adapter plugs into a standard GFCI protected electrical outlet. Location of transformer per local electrical code. TDB 3105 TouchTime Each low-voltage mechanical pushbutton or piezo switch actuates a non-hold-open, slowclosing anti-hammer solenoid valve that is timed from an electronic potted assembly. Each push button activates a flow of tempered water from the classic non-sectional sprayhead. TouchTime controls water flow through the use of solid state, digital circuitry. Timing is factory set at 12 second run time but is field adjustable to pre-set timeout periods and optional auto-flush function. The 24 hour flush function will activate water flow for a period of 60 seconds any time there has been no activation within the past 24 hours. Push button and piezo switch requires less than five pounds of pressure. Air Each push button pneumatically actuates a non-hold-open, air metering, singletemperature valve with field adjustable timing from 0 45 seconds. Factory preset at 12 seconds. Each pushbutton activates a flow of tempered water from the classic nonsectional sprayhead. Push button requires less than five pounds of pressure. Code Compliance and Certifications cupc Approval Terreon and TerreonRE Deep Bowl Washfountains are Uniform Plumbing Code (cupc), International Plumbing Code (IPC) and National Plumbing Code of Canada certified through the International Association of Plumbing and Mechanical Officials (IAPMO). Manufactured in compliance with IGC 156-2012, CSA B45 Series-2002 (R2013) & ASME A112.18.1-2012/ CSA B125.1-12. ANSI Standards Terreon and TerreonRE are certified by Home Innovation Lab to meet CSA B45.5/IAPMO Z124. Standard Mounting The TDB3105 at standard height is designed to comply with all ADA guidelines on reaches, clearances and operation. may not comply with all ADA dimensional Juvenile Mounting The TDB3105 is designed to mount at different heights to comply with guidelines on reaches, clearances and operation for various codes including ADA Accessibility Guidelines for Buildings and Facilities (ADAAG) and TAS (Texas Accessibility Standards). Always check your local and state codes. Standard product selections contained within this document are third party CERTIFIED to NSF/ANSI 372 meeting the Lead-Free content requirement. Any product configured with custom options will be COMPLIANT with NSF/ANSI 372 meeting the Lead-Free content requirement. Page 1 of 5 4/2/2018 Certified to NSF/ANSI 372

Standard Selections (Must select one from each category) Drain Type (select one) O Off-line vent with supplies from above B Centrally rising vent with supplies from above A Off-line vent with supplies from below H Centrally rising vent with supplies from below Mounting Type (select one) STD Standard 34" Rim JUV Juvenile 30" Rim TAS Intermediate 32" Rim Sprayhead Type (select one) CLC Classic Sprayhead (entire sprayhead activates) Activation Type (select one) IRP Infrared AST4 Air Pushbutton Water Supply Type (select one) TL Tempered Line TMA Thermostatic Mixing Valve Soap Dispenser Type (select one) LSD Liquid Soap Dispenser* MPSD PSD Powdered Soap Dispenser* MLSD Metal-Clad Liquid Soap Dispenser* NSD SA Cube Adapter for Individual Soap Dispensers (dispensers sold separately) Color of Terreon Bowl (select one) Standard Colors ALP-WHT Alpine White AVALANCHE Avalanche BONE Mesa Bone CHAR Charcoal Gray COBBLE Cobblestone DRIFT Driftwood DS-WHT Designer White DUNE Sand Dune E-GRAY Empire Gray GLACIER Glacier GRAPH Graphite LANNON Lannonstone TTPA TouchTime Pushbutton TTPB TouchTime Piezo Switch LONDON MOONSTONE O-TAUPE PEBBLE PEP-WHT POLAR SAND S-CREEK S-MIST WHT-SAND Designer Colors** (available at an additional charge) ARC-CHIP COFFEE Arctic Chip Coffee Bean RIVER TerreonRE Colors** (available at an additional charge) BIRCH-BARK Birch Bark MOONDUST DUSK Dusk OAT Metal-Clad Powdered Soap Dispenser* No Soap Dispenser London Gray Moonstone Organic Taupe Pebble Beach Peppered White Polar Ice Sandtrap Stone Creek Silver Mist White Sand Riverstone Moondust Oat Optional Selections Shroud Type SH Stainless Steel Shroud (Conceals overhead plumbing)** NONE No Shroud Support Tube Reinforcement Type TA 1-1/2" Tie Pipe Assembly (not required when SH is selected)** NONE No Tie Pipe Assembly Towel Dispenser Type CFTD (3) C-Fold, Multi-Fold Dispenser* SFTD (3) Single Fold Dispensers* NONE No Towel Dispenser * may not comply with all ADA guidelines ** Non-cancellable, non-returnable. This color contains large, randomly distributed chips. Towel Dispenser with SA soap option is non-cancelable, non-returnable. TTPA and TTPB valves require a low-voltage UL/CSA listed 120VAC/12VDC plug-in adapter. Page 2 of 5 4/2/2018

Dimensions - Standard 34" (864) 4 (1057) TDB3105 45-1/4" (1149) Standard 34" (864) 4 (1057) 45-1/4" (1149) 53-5/8" (1362) 61-1/2" (1562) 53" (1346) Dimensions - TAS 25-1/2" (648) 32" (813) 41-1/8" (1045) 44-3/4" (1136) TAS may not comply with all ADA or TAS dimensional 44-3/4" (1136) 53-1/8" (1349) 61" (1549) 52-1/2" (1334) 25-1/2" (648) 41-1/8" (1045) 32" (813) Dimensions - Juvenile Juvenile may not comply with all TAS dimensional 42-3/4" (1085) 59" (1499) 50-1/2" (1283) 30" (762) 39-1/8" (994) 30" (762) 39-1/8" (994) 42-3/4" (1085) 51-1/8" (1299) Page 3 of 5 4/2/2018 may not comply with all ADA or TAS dimensional

Rough-Ins Type A - Off-line vent with supplies from below. through Floor: Stub Up 2-1/2" (64) 4-1/8" (105) 2" (51) 8-1/2" (216) 4-3/4" (121) Type B - Centrally rising vent with supplies from above. from Above 1-1/2" NPT Vent to ceiling 1-1/4" (32) 4-1/8" (105) 8-1/2" (216) Page 4 of 5 4/2/2018

Rough-Ins Type H - Centrally rising vent with supplies from below. TDB3105 Through Floor: Stub Up 2-1/2" (64) 4-1/8" (105) 2" (51) 8-1/2" (216) 1-1/2" NPT Vent to ceiling 4-3/4" (121) Type O - Off-line vent with supplies from above. from Above 1-1/4" (32) 4-1/8" (105) 8-1/2" (216) Page 5 of 5 4/2/2018