High Efficiency Condensing Wall Hung Boiler Heating Only RK 50 Suitable for Cascade Systems SEDBUK BAND A CE 069 CE 069 RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY TA0E0.A005 ENGLISH TA05E0.D0905 ENGLISH
INDEX Introduction pag. Product information Overall Dimensions 2 Main components 3 Operating Diagram Specification text 5 Technical Data 6 Electric Wiring 8 Installation information Single Boiler installation 9 Single boiler + storage cylinder installation 0 Cascade installation 2 Flue Information Flue Kit options for a single boiler installation Flue Kit options for cascade installations 5 Controls Temperature control systems 6 System information Single boiler installation system 7 Cascade installation system 9 Approvals 22 Accessories 23
Introduction High flexibility of installation! model: RK 50 Self-Diagnostic Combustion chamber type: ROOM SEALED Output: 50 kw Premix and condensing Stainless Steel Condensing Exchanger High Efficiency (07,9 %) Single or cascade installation Compact Dimensions: mm. 90x70x700 CE Approval: no. 069BP06 Sedbuk BAND A High Efficiency Condensing wall hung boiler mod. RK 50, with a premixed combustion exchanger system for heating only. It can work as a single boiler or as an independent unit in a cascade system. The right solution for specification designers due to its flexibility of installation. The right product for installers due to the wide variety of accessories for simple and trouble free installation. Advantage for the final user energy saving, environmentally friendly suitable for both individual and multiply boiler installations.
Overall Dimensions 700 R SC G A 70 20 20 70 280 20 336 3 70 36 R G VS A 98 65 70 52 5 SC 07 90 78 23 08 270 2 KEY 90 A HEATING FLOW Ø "/ R HEATING RETURN Ø "/ SC CONDENSE CONNECTION Ø 25 G GAS Ø 3/" VS SAFETY VALVE DISCHARGE Ø 3/" 2
Main Components 25 9 9 7 2 2 22 5 2 6 2 2 22 5 2 2 9 0 3 8 25 3 23 7 6 20 3 5 2 2 RIGHT SIDE FRONT POS. DESCRIPTION CONDENSATE PIPES CONNECTION 2 FLUE EXHAUST BUSH 3 PUMP WITH AIR VENT FAN 5 CONDENSING EXCHANGER 6 MANIFOLD FLOW 7 MANIFOLD RETURN 8 (SIPHON) OR WATER TRAP 9 FLUE EXHAUST DUCT 0 BURNER OUTLET RUBBER HOSE CONDENSATE OUTLET RUBBER HOSE 2 AIR COMBUSTION INTAKE PIPE 3 BAR SAFETY VALVE ELECTRONIC GAS VALVE VK5V 5 (VENTURI) MIXING GROUP 6 HEATING SAFETY THERMOSTAT (HIGH LIMIT THERMOSTAT) 7 FLUE SAFETY THERMOSTAT 8 HEATING SENSOR 9 ELECTRONIC IGNITION BOARD 20 BOILER DRAIN POINT 2 IGNITION ELECTRODE 22 FLAME IONISATION PROBE 23 CONDENSATE OUTLET HOSE 2 WATER PRESSURE SWITCH 25 EXHAUST TEST SOCKET LEFT SIDE 8 3 3
Operating Diagram 6 3 2 5 5 6 7 3 0 9 7 KEY R SC G A - HEATING RETURN - CONDENSATE DRAINING POINT - GAS - HEATING FLOW 2 8 9 8 R G SC A POS. DESCRIPTION PUMP HEATING SAFETY THERMOSTAT 2 AIR VENT 2 FLUE SAFETY THERMOSTAT 3 FAN 3 HEATING SENSOR CONDENSING EXCHANGER BOILER DRAINING TAP 5 BURNER 5 IGNITION ELECTRODES (X2) 6 FLUE EXHAUST DUCT 6 FLAME IONISATION PROBE 7 AIR COMBUSTION INTAKE PIPE 7 CONDENSATIE OUTLET HOSE 8 BAR SAFETY VALVE 8 SIPHON) WATER TRAP 9 ELECTRONIC GAS VALVE VK5V 9 WATER PRESSURE SWITCH 0 (VENTURI) MIXING GROUP
Specification Text Wall hung high efficiency condensing boiler main components specification: : Premixed stainless steel combustion exchanger system with stainless steel radial gas burner equipped with 2 ignition electrodes and flame ionisation probe; Condensing exchanger with primary coil type exchanger gas/water in AISI 36L stainless steel material; Room sealed combustion chamber with separate air intake and flue exhaust connections. Variable speed Exhaust fan; System temperature flow sensor; High limit thermostat; Circulating pump with automatic air vent; Water pressure switch; Condensate draining circuit including trap (siphon) and flexible pipe; Control Panel with microprocessor controlled electronic printed circuit board for a continuous modulation; possibility of outside temperature sensor connection, dhw production priority control. Short cycling device in heating mode, frost protection, pump inactivity protection, chimney sweeper (test function); External casing panels; Operational parameters setting through touch pads and monitoring of operation mode through the digital display; Digital display showing the self-diagnostic function through error codes, the operating temperatures and settings; Safety Features: Self-diagnostic; Water pressure switch: water deficiency control and boiler lock-out in case of low or zero water pressure. High limit thermostat: high temperature control across the primary exchanger; Flue safety thermostat: high temperature control across the flue exhaust; bar safety valve primary circuit; Frost protection; Suitable for: Operation in a cascade installation system (up to boilers); Operation in a single boiler installation and connection to a remote storage cylinder through an external 3-way valve and domestic hot water temperature sensor, for the domestic hot water production; Operation in a cascade installation controlled by a cascade regulator system, heating flow sensor and outside temperature sensor. Technical specification Device Gas Category II 2H3+ Gas: Natural Gas or L.P.G.. Modulation range: 2 5 kw; Output (80-60 C): 9.90 kw Output (50-30 C): 5.50 kw Heating temperature setting: 25 85 C Dimensions: 90x700x70 Electrical protection: IPXD CE Approval Sedbuk Band A 5
technical data Technical Data CE certification no. n 069BP06 Flue category (UNI062) B23, C3, C33, C3, C53, C63, C83 Heat Input max kw 5 Heat Input min kw 2 Heat Output max (80/60 ) kw 9,88 Heat Output max (50/30 ) kw 5,7 Heat Output min (80/60 ) kw,65 00% Efficiency 00% (80/60 ) % 97,8 Efficiency 00% (50/30 ) % 06,8 Efficiency 30% (80/60 ) % 0,8 Efficiency 30% (50/30 ) % 07,9 Gas Directive 92/2/ECC - Efficiency marking stars Sedbuk band A Heating circuit Central heating water temperature setting (min-max) C 30-80 / 25-0 Max. heating temperature C 90 Max. working pressure (heating) bar 5 Primary circuit water content litres 3.5 Dimensions Width mm 90 Height Height 700 Depth mm 70 Weight kg 80 Hydraulic connections Flow connection Ø / Return connection Ø / Gas connection Ø 3/ Flue systems Horizontal single pipe flue system - KIT AK50 Ø mm 25/80 Max. flue length m 5 Vertical-Coaxial flue system - KIT CK50 Ø mm 25/80 Max. flue length m 5 Gas Supply Natural Gas G 20 Inlet pressure mbar 20 Gas consumption m3/h 5,0 Liquid Butane Gas G 30 Max. Inlet pressure mbar 30 Gas consumption kg/h.20 Liquid Propane Gas G 3 Max. Inlet pressure mbar 37 Gas consumption kg/h 3.96 Electrical supply Power Supply V/Hz 230/50 Electrical power consumption W 95 Electrical protection IP XD 6
technical data Combustion specification Combustion Efficiency % 97.9 Flue efficiency losses with burner on (00% Output) % 2. Flue efficiency losses with burner on (Min. Output) % 2.9 Casing efficiency losses (00% Output) % 0. Casing efficiency losses (Min. Output) % Fumes temperature at nominal output C 65.6 Fumes temperature at minimum output C 60 Fumes flow rate at Nominal Output kg/h 80 Fumes flow rate at minimum Output kg/h 9.7 CO 2 value at nominal output % 9.66 CO 2 value at minimum output % 9.2 CO value at nominal output ppm 0 CO value at minimum output ppm 5 NOx ppm 20 NOx mg/kwh 35 NOx class (European Standard UNI EN 297 pr A5 stars 5 PUMP PERFORMANCE CHART Head kpa 70 60 RSL 5/7 50 0 30 20 0 0 0 200 00 600 800 000 200 00 600 800 2000 2200 200 2600 Flow rate litres/h 7
+ps electric wiring P.C.B. PLUG S565PD2020 P.5 bar SS (WITH REMOTE BOILER) SR brown light-blue red 8 9 M 5 6 7 TA orange orange black 8 9 50 M8 59 50 Hz light-blue brown orange white brown brown black M9 55 56 57 58 60 6 orange black black L N POWER SUPPLY LINK IG light-blue 5 6 7 8 M2 9 2 3 M 5 52 53 5 5 6 7 8 brown light-blue white red brown 3 0 2 M PWM 2 3 -V HS +V MOD RV CM +5V GND P2 P R56A +20V 9 M2 TP CM2 FAN PRINTED CIRCUIT BOARD SK00 COD. 76658LA yellow green white black brown 230V Hz ps - pwm Hs ps + 5 3 2 brown 2 0 9 8 7 6 light-blue N L 230 V AC TS light-blue brown black M3 5 6 7 ps - pwm Hs PRINTED CIRCUIT BOARD CVI-M SM 2005 COD. 76655LA M0 M9 brown black M M0 M2 70 7 72 73 7 M8 grey light-blue grey black SE M2 M3 M7 M6 M5 M M3 M2 M FAN tipo RG28/300-362 ELECTRONIC IGNITION BOARD S565PD2020 - cod. 76657LA DISPLAY DIGITAL BOARD 2000 SKO6206 (COD. 7665LA) 2 0 9 8 7 6 5 3 2 L N LM KEY - LINE - NEUTRAL L N PAC - WATER PRESSURE SWITCH IG - MAIN SWITCH SR - HEATING SENSOR P - PUMP TS - SAFETY THERMOSTAT SE - OUTDOOR SENSOR TEMPERATURE TA - ROOM THERMOSTAT EA - IGNITION ELECTRODE ER - IONISATION ELECTRODE EV - FAN 8
single boiler installation A wide choice of accessories has been designed to ensure the highest flexibility of installation. The solution described below allows to manage different flow rates between the primary and the secondary with the use of a compensator. 70 85 55 700 260LP 5 6 7 2625LP RI MI 0 360 HYDRAULIC CONNECTIONS MI HEATING FLOW Ø 2" RI HEATING RETURN Ø 2" G GAS Ø 3/" SI TUNDISH Ø 3/" SC CONDENSE DRAIN POINT Ø 25 ACCESSORIES 2625LP HYDRAULIC COMPENSATOR KIT FOR SINGLE BOILER INSTALLATION Ø2" 260LP CONNECTION KIT KEY EXPANSION VESSEL CONNECTION (Ø3/") 2 BAR PRESSURE SAFETY VALVE 3 TUNDISH ISOLATING VALVE 5 STRAINER 6 WATER PRESSURE GAUGE CONNECTION SOCKET (Ø/8 ) 7 FILLING LOOP CONNECTION (Ø/2") 9
single boiler + DHW storage cylinder installation A single boiler installation connected to a storage cylinder for the DHW production with the use of a 3-way valve Kit 70 85 250 55 700 260LP RB 5 2 3 6 7 MB 2625LP 26097LP 0 360 RI MI HYDRAULIC CONNECTIONS MI HEATING FLOW Ø 2" RI HEATING RETURN Ø 2" MB EXTERNAL CYLINDER FLOW Ø " RB EXTERNAL CYLINDER RETURN Ø " G GAS Ø 3/" SI TUNDISH Ø 3/" SC CONDENSE DRAIN POINT Ø 25 KEY EXPANSION VESSEL CONNECTION (Ø3/") 2 BAR PRESSURE SAFETY VALVE 3 TUNDISH ISOLATING VALVE 5 STRAINER 6 WATER PRESSURE GAUGE CONNECTION SOCKET (Ø/8 ) 7 FILLING LOOP CONNECTION (Ø/2") ACCESSORIES 2625LP HYDRAULIC COMPENSATOR KIT FOR SINGLE BOILER INSTALLATION Ø2" 26097LP 3-WAY VALVE KIT FOR REMOTE CYLINDER CONNECTION (code 329LA - " DHW SENSOR " INCLUDED) 260LP CONNECTION KIT 0
accessories - single boiler installation Connection Kit - code 260LP For a direct connection to the boiler. On the return connection a strainer has been included to protect the boiler from eventual impurities that can cause obstructions. Key. strainer 2. isolating valve 3. expansion vessel connection (Ø3/ ). water pressure gauge connection (Ø/8 ) 5. filling loop connection (Ø/2 ) Ø"/2 2 Ø"/2 2 2 3 5 Ø"/2 Ø"/2 Hydraulic compensator Kit - code 2625LP The use of a compensator is recommended when there is a primary circuit with its own circulating pump and a secondary circuit with one or more circulating pumps. The compensator will negate situations whereby the different pumps of the circuit will interact one with another creating abnormal flow variations. The compensator will create a low pressure loss zone so that the primary circuit (of the boiler) will become independent from the secondary circuit to guarantee flexibility of installation and on systems with several pumps, high flow rates and high pump heads. 3 Ø"/2 2 Ø"/2 Key. washers (x2) Ø /2; 2. washers (x2) Ø2 /2; 3. hydraulic compensator. Ø2 /2 => Ø2 adapter Ø2" Ø2" 2 3-Way valve Kit - code 26097LP It is possible to connect the boiler to a remote storage cylinder for the domestic hot water production by installing the 3-Way valve Kit. The kit includes a 3- Way valve (to be fitted onto the return), a cylinder DHW temperature sensor (8 metres length) that will be connected to the boiler main pcb to enable the correct setting and data display (DHW temperature) Key. flow manifold Ø /2; 2. return manifold Ø /2; 3. 3-Way valve;. Storage cylinder DHW temperature sensor EXTERNAL CYLINDER RETURN Ø" Ø"/2 2 Ø"/2 HEATING RETURN Ø"/2 Ø"/2 HEATING FLOW EXTERNAL CYLINDER FLOW Ø" 3
cascade installation 8203LP 820LP SI 26099LP 2600LP KEY HYDRAULIC CONNECTIONS 2 3 ISOLATING VALVE RM EXTERNAL CYLINDER FLOW Ø "/2 5 BAR PRESSURE SAFETY VALVE CM HEATING FLOW MANIFOLD DN 65 PN6 TUNDISH CR HEATING RETURN MANIFOLD DN 65 PN6 STRAINER NON-RETURN VALVE RR EXTERNAL CYLINDER RETURN Ø "/2 G GAS SI TUNDISH Ø 3/" Ø 3/" ACCESSORIES 26099LP HYDRAULIC MANIFOLD KIT FOR 2 BOILERS CASCADE INSTALLATION 2600LP HYDRAULIC MANIFOLD KIT FOR ADDITIONAL BOILER IN CASCADE 8203LP 820LP FLUE MANIFOLD KIT D.25 FOR CASCADE INSTALLATION FLUE MANIFOLD KIT D.25 FOR ADDITIONAL CASCADE INSTALLATION HEATING FLOW HEATING RETURN 2
accessories - cascade installation Hydraulic manifold Kit for cascade installation For the installation of or more boilers in a cascade installation up to a maximum of boilers: Hydraulic manifold Kit for no.2 boilers in cascade installation (cod. 26099LP); Hydraulic manifold Kit for additional boiler in cascade installation (cod. 2600LP); Hydraulic manifold are equipped with: Isolating valves to guarantee ease of maintenance or a the temporary exclusion of boiler without interrupting the operation of the whole cascade installation. Non-return valve for every single boiler to prevent any circulation when boiler is OFF; Line Strainer to protect the boiler from eventual obstruction created by impurities of the hydraulic circuit. 8 2 3 6 DN 65 PN6 HEATING FLOW 5 7 DN 65 PN6 HEATING RETURN 26099LP 2600LP Key. Strainer 2. 3-Way isolating valve 3. Isolating valve. Hydraulic connector to the flow manifold Ø /2 5. Hydraulic connector to the return manifold Ø /2 6. Flow manifold Ø2 /2 7. Return manifold Ø2 /2 8. Non-Return valve Ø /2 3
flue kit options (polypropylene) The RK 50 boiler has been approved for an indoor and also outdoor installation. For the correct operation of the unit it is highly recommend to use only original Radiant flue kit, flue accessories and parts. Flue Kits are in polypropylene material to guarantee the highest mechanical resistance to the chemical action of the condensate and an easy installation. Flue Kit Options for SINGLE BOILER INSTALLATION Max Flue Length: kit EK50 - Horizontal single pipe flue kit Ø80 code 8207LP; depending by flue system data kit FK50 - Vertical single pipe flue kit Ø80 code 8206LP; 3 metres kit AK50 - Horizontal-Coaxial flue kit Ø25/80 code 8209LP; 5 metres kit CK50 - Vertical-Coaxial flue kit Ø25/80 code 820LP; 5 metres Kit EK50 code 8207LP; Kit FK50 code 8206LP; Kit CK50 code 822LP; Kit AK50 code 8209LP;
flue kit options (polypropylene) Flue Kit systems for cascade installation With cascade installation combustion emissions have to be discharged in only one flue duct through the installation of flue manifolds. Available flue manifolds: Kit MK50 - Flue Manifold Kit for no. 2 boilers in cascade installation Kit SK50 - Flue Manifold for additional boiler in cascade installation cod. 8203LP; cod. 820LP; Flue Parts are in polypropylene material to guarantee the highest mechanical resistance to the chemical action of the condensate and an easy installation. The Flue Manifold Kit allows to connect the boiler to the main flue duct through a supplied connector with a mechanical non-return damper to avoid a flue return in cases where one or more boilers are not in operation. 8203LP 820LP 5
system controls / regulators The purpose of a high efficiency condensing boiler installation is to have a thermal system supplying exactly the right amount of power in the most efficient way. In order to satisfy the various system requirements for either single or cascade installations, radiant offers a wide choice of controls that optimize the system temperature regulation according to the boiler operation. Single Boiler Installation Single Zone if the boiler operates within a single zone it is recommended to use a chronostat (Remote Control LCD code 52535LP) and an outside temperature sensor (code 73506LA) or a standard type chronostat: Multiple Zones it is necessary to use the Cascade systems regulator (76669LA) together with a zone control room thermostat (76670LA) for each zone; Cascade Installation: Cascade systems regulator (76669LA) together with the zone control room thermostat (76670LA) for each zone; Cascade system regulator Zone control room thermostat Heating flow sensor Electronic regulator for cascade installation control Room thermostat for the single zone control code: 76669LA code: 76670LA code: 3276LA Heating flow sensor for the regulation of system temperature External sensor D.H.W. storage cylinder sensor Remote Control LCD External sensor for the heating flow Dhw sensor for the storage cylinder Total boiler control temperature control temperature control code: 3277LA code: 3278LA code: 52535LP External sensor (for Remote control LCD) External sensor for the heating flow temperature control to be use combined with Remote Control LCD code: 73506LA 6
system example individual boiler + DHW storage cylinder NOTE THERE IS A STRAINER ON THE HEATING CIRCUIT.. THE INSTALLATION OF AN ADDITIONAL STRAINER ON THE SECONDARY CIRCUIT IS RECOMMENDED. STORAGE CYLINDER DHW TEMPERATURE SENSOR code 329LA REMOTO LCD code 52535LP EXTERNAL SENSOR code 73506LA GAS CONDENSATION OUTLET HEATING FLOW HEATING RETURN 7
system example individual boiler + DHW storage cylinder KEY RK 50 2 CASCADE SYSTEM REGULATOR 3 ZONE CONTROL ROOM THERMOSTAT EXTERNAL SENSOR 5 MANIFOLD FLOW SENSOR 6 HEATING FLOW SENSOR 7 D.H.W. STORAGE CYLINDER SENSOR 8 3-WAY MIXING VALVE NOTE THERE IS A STRAINER ON THE HEATING CIRCUIT. THE INSTALLATION OF AN ADDITIONAL STRAINER ON THE SECONDARY CIRCUIT IS RECOMMENDED. FILLING LOOP WALL EXPOSED TO NORTH GAS CONDENSATION OUTLET 2 6 5 3 Zone n 8 6 3 Zone n 2 7 8
system example cascade installation KEY RK 50 2 CASCADE SYSTEM REGULATOR 3 ZONE CONTROL ROOM THERMOSTAT EXTERNAL SENSOR 5 MANIFOLD FLOW SENSOR 6 HEATING FLOW SENSOR 7 D.H.W. STORAGE CYLINDER SENSOR 8 3-WAY MIXING VALVE CONDENSATION OUTLET GAS NOTE THERE IS A STRAINER ON THE HEATING CIRCUIT. THE INSTALLATION OF AN ADDITIONAL STRAINER ON THE SECONDARY CIRCUIT IS RECOMMENDED. FILLING LOOP WALL EXPOSED TO NORTH 2 6 5 3 Zone n 8 3 Zone n 2 7 9
system example cascade installation KEY RK 50 2 CASCADE SYSTEM REGULATOR 3 ZONE CONTROL ROOM THERMOSTAT EXTERNAL SENSOR 5 MANIFOLD FLOW SENSOR 6 HEATING FLOW SENSOR 7 D.H.W. STORAGE CYLINDER SENSOR 8 3-WAY MIXING VALVE NOTE THERE IS A STRAINER ON THE HEATING CIRCUIT. THE INSTALLATION OF AN ADDITIONAL STRAINER ON THE SECONDARY CIRCUIT IS RECOMMENDED. CONDENSATION OUTLET GAS FILLING LOOP WALL EXPOSED TO NORTH 2 9 6 5 3 3 Zone n Zone n 2 8 3 Zone n 3 6 8 6 8 3 Zone n 7 20
system example cascade installation CONDENSATION OUTLET GAS 2 5 WALL EXPOSED TO NORTH 3 3 Zone n Zone n 2 6 8 KEY RK 50 2 CASCADE SYSTEM REGULATOR 3 ZONE CONTROL ROOM THERMOSTAT EXTERNAL SENSOR 5 MANIFOLD FLOW SENSOR 6 HEATING FLOW SENSOR 7 D.H.W. STORAGE CYLINDER SENSOR 8 3-WAY MIXING VALVE NOTE THERE IS A STRAINER ON THE HEATING CIRCUIT. THE INSTALLATION OF AN ADDITIONAL STRAINER ON THE SECONDARY CIRCUIT IS RECOMMENDED. 7 2
CE Approval 22
System Controls / Regulators Cascade system regulator Zone control room thermostat Heating flow sensor Electronic regulator for cascade installation control Room thermostat for the single zone control Heating flow sensor for the regulation of system temperature code: 76669LA code: 76670LA code: 3276LA External sensor D.H.W. storage cylinder sensor Remote Control LCD External sensor for the heating flow Dhw sensor for the storage cylinder Total boiler control temperature control temperature control code: 3277LA code: 3278LP code: 52535LP External sensor (for Remote control LCD) External sensor for the heating flow temperature control to be use combined with Remote Control LCD code: 73506LA 23
hydraulic accessories Hydraulic manifold kit for 2 boilers cascade installation Kit for 2 boilers installation: it includes isolating valves, non-return valve, srainer for each boiler. Hydraulic manifold kit for additional boiler in cascade For additional boiler: it includes isolating valves, non-return valve, srainer for additional boiler 3-way valve kit for remote cylinder connection (DHW sensor included) For a remote storage cylinder installation. It includes 329LA DHW temperature sensor code: 26099LP code: 2600LP code: 26097LP Hydraulic compensator kit for single boiler installation System full control also with non-constant water flow rates. Connection Kit for single boiler installation It includes: isolating valves, srainer. code: 2625LP code: 260LP 2
flue accessories cascade installation Flue manifold kit MK50 Ø25 for 2 boilers in cascade installation For 2 boilers in cascade installation: complete with no return dampers and condensate trap. Flue manifold kit SK50 Ø25 for additional boiler in cascade Equipped with no return damper for cascade installation Extension Kit for flue manifold Ø25 L = m code: 8203LP code: 820LP code: 8205LP Extension Kit for flue manifold Ø25 L = 0.5 m 90 flue bend Ø25 MF extension kit in PP 5 flue bend Ø25 MF extension kit in PP code: 823LP code: 829LA code: 8220LA 25
flue accessories single boiler installation Kit AK50 - Horizontal-coaxial flue kit Ø25/80 (PP inside) For the exhaust of combustion products and air intake through the coaxial pipes. Kit CK50 - Vertical-Coaxial flue system Ø25/80 (PP inside) mt. extension Ø25/80 MF (PP inside) L = m code: 8209LP code: 822LP code: 828LA 5 flue bend Ø25/80 MF extension (PP inside) 90 flue bend Ø25/80 MF extension (PP inside) Kit EK50 - Flue kit Ø80 single pipe in PP To exhaust combustion products into a flue duct. code: 27088LA code: 27089LA code: 8207LP Kit FK50 - Vertical single pipe flue system Ø80 in PP 90 flue bend Ø80 MF extension kit in PP 5 flue bend Ø80 MF extension kit in PP code: 8206LP code: 27055LA code: 27056LA mt. extension Ø80 MF in PP code: 82090LP 26
RADIANT BRUCIATORI s.p.a. Via Pantanelli, 6/66-6025 Loc. Montelabbate (PU) Tel. +39 072 9079. fax. +39 072 9079279 e-mail: tecnico@radiant Internet: http://www.radiant.it DATI TECNICI E MISURE NON SONO IMPEGNATIVE. LA DITTA SI RISERVA IL DIRITTO DI EVENTUALI VARIAZIONI SENZA L'OBBLIGO DI PREAVVISO. DECLINIAMO OGNI RESPONSABILITÀ PER EVENTUALI INESATTEZZE CONTENUTE NEL PRESENTE OPUSCOLO, SE DOVUTE AD ERRORI DI STAMPA O DI TRASCRIZIONE. E+OE TUTTI I DIRITTI SONO RISERVATI. NESSUNA PARTE DI QUESTO DOCUMENTO PUÒ ESSERE RIPRODOTTA, MEMORIZZATA IN SISTEMI D ARCHIVIO, O TRASMESSA IN QUALSIASI FORMA O MEZZO ELETTRONICO, MECCANICO, FOTOCOPIA, REGISTRAZIONE O ALTRI, SENZA LA PREVENTIVA AUTORIZZAZIONE SCRITTA DELLA DITTA. TA05E0.D0905