Wet ElectroStatic Precipitator

Similar documents
Providing State-of-the-Art Fine Particulate Control Through Advanced High Energy Ionization

[1] Lecture 2 Particulate emission control by mechanical separation & wet gas scrubbing

Lecture 5 Particulate emission control by electrostatic precipitation

M O D U L E IV C O N T R O L T E C H N I Q U E S

ELECTRO STATIC PRECIPITATOR [ESP]

Sludge Dryer Wet Scrubber Used to Produce Renewable Energy

Enviro International Corporation. WET SCRUBBER

our technology Electrostatic Precipitators esp plus maintenance features Electrostatic Precipitators

SPRAY DRYING SYSTEMS INC.

Division III Process Gas Treatment Equipment

ecodry Figure 1 - Process Diagram ecodry B General Process Description

KPR SOLVENT CONCENTRATING SYSTEMS

SCHEUCH ELECTROSTATIC PRECIPITATORS INNOVATIVE TECHNOLOGIES FOR DEDUSTING FLUE GASES

AEROSOL SEPARATION PARTICLE CHARACTERISTICS 27/11/2010

CHAPTER 5 ELECTROSTATIC PRECIPITATORS. Operating Principles. Precipitator Energization

C H A P T E R 9 ENVIRONMENTAL PROTECTION AGENCY. APTI 413: Control of Particulate Matter Emissions. Student Manual Chapter 9.

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business

Hurricane Cyclones To Reduce Emissions of Dryer Cyclones in Glowood Pellet Plant April 2016

TRION Air Purification systems

FACILITY PROFILE ARBEC FOREST PRODUCTS INC. PRODUITS FORESTIERS ARBEC INC. Oriented Strand Board Mill Miramichi, N.B. Prepared by:

Modern Blast Furnace Gas. Cleaning Practices

CLEAN AIR SYSTEMS DIVISION. An ISO 9001 Certified Company. Nan Technical Trading W.L.L P.O.Box Manama Kingdom of Bahrain

Evaporation The process in which a liquid dissipates or emits vapor, fumes, or invisible minute particles.

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

Electrostatic Precipitator Systems

LOCK H M L REPLACE SLEEPING ANTI-POLLEN IONIZER UV-LAMP. User Manual

Mist eliminators for Flue Gas Desulphurization

Section 2. Product overview & label familiarisation

Chemistry Instrumental Analysis Lecture 29. Chem 4631

Kitchen Exhaust Air Cleaning Systems

Evaporation System: Types and Design Aspects

Venturi wet scrubber VDN Separation of combustible, explosive, humid and adhesive dusts

PSH Series. Modular ESP Mist Collectors

There are a number of factors in a process which may result in liquid entrainment. Some of the commonly observed causes are discussed below.

The Enviro-Clean Air Scrubber keeps the Atmosphere Clear and Creates Clean Air

Solid and Liquid Pollutants

Für Compacting alle Einsatzgebiete. Raumlufttechnik. High Pressure Humidifier and Airwasher Type HPH. Power Screw Type CPS. der dischargeoffinedust

Gulf Perlite L.L.C: Perlite Filter Aid Technical Brochure

Commercial Kitchen Air Cleaner. UL Standards 867 and 710 Intertek File # Air Purification Systems

ECONOMIC IN ECOLOGY. Innovative environmental technologies

DESIGN AND FABRICATION OF ELECTRO STATIC PRECIPITATON IN AUTOMOBILE

The best technical solution for high powder concentrations High level filtering surface and compact design Heavy duty construction for long life in

A WASHABLE POROUS METAL HEPA FILTER

Electrostatic Precipitator

Shyam Enterprises 9 PACKAGE UNIT

Instruction Manual FEEL THE ENERGY. FEEL THE FRESHNESS.

COMPOSITEOMPOSITE MESHESH PADAD (CMP)

LTG High Pressure Humidifier and Airwasher

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

DFE T ECHNOLOGY. At Conceptronic, the design and management process for reflow soldering systems is called Dynamic Flow Engineering, or DFE.

Heat exchangers in Thermo Plate-design Type XPT. + variable + cleanable + efficient + safe FULLY WELDED

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

UralActiv. manufacturer of products from polypropylene GAS WASHERS. UralActiv Ltd +7 (343)

PUBLICATION ICAC-EP-1 NOVEMBER 2000 TERMINOLOGY FOR ELECTROSTATIC PRECIPITATORS

Ashirwad Carbonics (India) Private Limited

Electrostatic Precipitator

CLEACOM Engineered System Solutions. Established 24/7 technology for the separation of dust and fume during compounding processes

Supplying Clean Air to Industry

How is the heat transfer?

Membrane Dryer. Air inflow rate KMM Series to m 3 /min

Filter cleaning in hot gas applications PENTAIR 1

Tri-Mer Packed Bed Tower Scrubbers

PSH SERIES. Modular ESP Mist Collectors

GRAVITY SCREEN FILTER

As we discussed early in the first chapter that heat can transfer through materials and the surrounding medium whenever temperature gradient exists

OPERATION & MAINTENANCE MANUAL MODEL SC SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

DISCHARGING. electrostatic innovations. Top-Class Discharging

PET Drying Technology

Air Purification Systems. Clearing the Air. Air Purification Systems. Air Purification Systems

DRAFT. Electroplating Tip Sheet Drag-Out Reduction. Background

SUNOCO Heat Transfer Fluids

Heat Exchangers. Heat Exchangers 1

TMCI Padovan Evaporators

Boiler MACT Deadline Is Here, Are You In Compliance? Sponsored by

Commercial Kitchen Ventilation Services. Ventilation Systems. Canopies. Ductwork. Gas Interlock Systems

HEAT EXCHANGE IN GENERAL

Publication ICAC-EP-10W. January 2008 BID SPECIFICATION INFORMATION REQUIREMENTS AND BID EVALUATION FORM FOR WET ELECTROSTATIC PRECIPITATORS

A Project of Cleaning Smog and Particulates by Using Smog Cleaner with Negative-Ion Generator

Air Quality Control System

SNC1D PHYSICS 3/9/2013. THE CHARACTERISTICS OF ELECTRICITY L Static Electricity (P.396, ) Static Electricity. Static Electricity

White paper Compressed air drying

WHAT IS A BOILER? BOILER IS AN EQUIPMENT WHICH PRODUCES STEAM AT THE REQUIRED PRESSURE AND TEMPERATURE. BOILER DESIGN, MANUFACTURE & INSTALLATION ARE

APPLICATION PROFILE EXPLOSIONS IN CEMENT PLANTS EXPLOSIONS IN CEMENT PLANTS CEMENT PLANT EQUIPMENT WITH HIGHEST EXPLOSION POTENTIAL. Form No.

IN THE PULP AND PAPER INDUSTRY

EU Air Handling Units with SEMCO EXCLU-SIEVE

Fire Detection System: An Overview

AIR SCRUBBER X-3400, X-3500, X-3700

Type N RotoClone. Hydrostatic Precipitator. Better Air is Our Business

COMPOSITE MESH PAD (CMP) DRY SCRUBBERS ENFORCER III TM III

CARE GUIDANCE. Local Exhaust Ventilation (LEV) Systems for High Temperature Insulation Wool (HTIW) LEVEL 2 RECOMMENDATIONS ON BEST PRACTICE

Volume 10 Summer Understanding Terminology Key to Treatment Program Success

Clean Air Optima Plasma Ionizer Air Purifier CA-267

Effect of the Electro Breeze Air Filter on Airborne Particles in a Recirculating Air Duct

HFID Heated Total Hydrocarbon Analyzer Module

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

Air Pollution Control Systems. Air Pollution Control Systems.

WAS STARTED BY CARLOS BAHAMONDES MASAFIERRO

Precipitator Solves Dryer Problem

The leader in gas dehydration & filtration

DOWNDRAFT BENCH SERIES

Transcription:

Wet ElectroStatic Precipitator

2 WESP WET Electrostatic Precipitator Wet Electrostatic Precipitators (WESP) offer efficient emissions control for sub-micron particulate, heavy metals, acid mist, oil mist. The WESP is recommended because of its proven performance, compactness, robust design, automatic operation, and low operating costs. Operation principles and basic design HIGH VOLTAGE SYSTEM AIR PURGE SYSTEM INSULATORS CLEAN GAS OUTLET FAN COOLING JACKET COLLECTOR SECTION ELECTRODES WATER MAKE UP SCRUBBER SECTION RAW GAS INLET BLEED Waste incinerator Conductive GRP WESP (Tessenderlo Group) Field of application Textile processing Veneer and particle board dryers Phosphorous furnace emission Silicon manufacturing Hazardous waste incinerator Plastics and gasket manufacturing Biomass drying Sulphuric acid plants Food drying Pollutants removal Scrubber section RECYCLE PUMP Hotcontaminatedgasfromtheproductionlinesarecooledtofull saturation and pre-cleaned from all particles larger than 2 microns in a special un-clogging scrubber. The scrubber creates a turbulent layer of fine mist which accomplishes the mass transfer of toxic gases and the capture of large particles onto the mist bubbles. The turbulent layer provides good mass transfer and offers efficient gas cooling below adiabatic saturation together with good absorption of soluble compounds. HCl, HBr, HF, H 2 S, NH 3 SO 2, SO 3, SiO 2 Oil mist, sub-micron particulate, VOCs Aldehyds, phenol Rod Scrubber details with non-clogging washing system

3 Collector section Sizing In the vertical design, the evenly distributed saturated gas flows upward through the electrostatic section of the WESP. An ionizing electrode runs down the centre of each tube. A strong electrical field is generated between the central discharge electrode and the collecting tube. Thevelocitycomponentatwhichtheparticlesmoveinthegas stream towards the collecting electrodes is called migration velocity. It is the most important empirical factor for the WESP sizing: it is correlated to the particle efficiency removal with the Deutsch-Anderson formula: Where: η = collection efficiency A = collection area Wc = particle terminal electrostatic velocity V = gas flow rate Operation principle Electrons are emitted from the discharge electrodes which are charged with a rectified negative high voltage. Due to the high voltage difference, these electrons migrate towards the collecting electrodes: as particles pass through the gap between the discharge electrodes and the tube walls, they are intercepted by negatively charged gas molecules. These negatively charged gas molecules or negative ions accumulate on the particles surface and become fully saturated with negative charge. As the gas with charged particles passes up the tube, it enters the collection section where there are strong repelling forces. The strong electrical field causes the charged particles and entrained droplets to migrate to the inner surfaces of the tube and consequently to be removed from the gas flow. Equation indicates that the electrostatic precipitator should have the following characteristics: high collector surface area (A) optimum gas velocity to allow enough time for particles to deposit (Q/A) high migration velocity (Vt) AWSisabletooptimizealltheseparametersinordertoreachthe best performance needed by the process. Technical features AWS engineers industrial grade, heavy-duty, low-maintenance design WESP s. High voltage frame The high voltage discharge system consists of a rigid frame suspended with ceramic insulators located outside the flue gas stream in order to avoid contamination caused by condensation and particle deposits. Ceramic insulator and insulator frame

4 High voltage and current control Automatic high voltage power generation. Solid state microprocessor control with variable inductance system. New models with high frequency mono-phase high voltage system. WESP Model Depending on the application AWS. can choose the most efficient and cost-effective WESP model. We can choose from different technology: A) Condensing tubular WESP B) Tubular WESP C) Honeycomb WESP D) Horizontal plate WESP Ionizing electrodes Heavy duty, rigid electrodes provide long life and no maintenance or adjustments. Sharp point design provides high intensity charging fields. Rigidly supported for greater reliability with no maintenance. Air purge system The insulators compartments are purged with filtered, heated air to keep the insulators clean and dry. A) Condensing tubular WESP In the Condensing WESP, which is the best available technology, thewallsofthecollectingtubesarecooledontheoutsidesurface by a water jacket, causing a film of condensed moisture from the saturated gas to gather on the inner surface of the tubes. The water film created on the walls of the tubes flushes the collected particles down and out of the tubes. No further cleaning is necessary. It also reduces clean water usage, minimizing flushing requirements. CLEAN GAS OUT COLD WATER IN WATER OUT PARTICLES RAW GAS IN WATER Condensing WESP self cleaning principle and view of the collecting section Safety interlocks To ensure personal safety, the WESP is provided with mechanical interlocks that require the complete shut down of the plant before entering the system. Liquid effluent treatment (oil separators, chemical- physical treatments, filtration technologies,...) can be integrated into the design to achieve liquid discharge close to zero.

5 B) Tubular WESP Inthoseapplicationswheretheparticulatetobecapturedisnotso sticky, the Condensing WESP model can be replaced by a simple tubular WESP where the walls of the collecting tubes are not cooled on the outside by water jacket. This solution allows costs reduction ensuring a good gas purification at the same time. CLEAN GAS OUT D) Plate WESP In many applications it is preferred to save space in elevation and to design a gas treatment directly in line with the process. In other cases it is necessary to combine the gas treatment with a heat recovery. In all these applications the solution with horizontal plate WESP is preferred. AWS can satisfy all client s requests choosing the most costeffective solution. PARTICLES RAW GAS IN WATER Tubular WESP: collecting principle and view of the collector section Plate WESP: general assembly and internal view C) Honeycomb WESP For larger applications or where it is necessary to minimize the plant space it is possible to design a WESP with hexagonal honeycomb clusters. This solution offers the largest precipitation surface in the smallest space. Honeycomb WESP: detail of the collector section Example of application in the chemical sector

Main office AWS Corp. srl Vicolo Scuri, 123 24059 Urgnano (BG) - ITALY Phone +39 035 4819906 / +39 035 6014844 Fax +39 035 19967687 info@awscorp.it - www.awscorp.it B02 WESP R05