HOTLINE:

Similar documents
Thank you for choosing EnviroVent

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

energisava 200 WALL & FLOOR MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

energisava 200 CEILING MOUNTED VERSION INSTALLATION GUIDE FOR ENGINEER / INSTALLER

Thank you for choosing EnviroVent

Thank you for choosing EnviroVent

November This product has been reconfigured Please read these instructions

Wiring the fan correctly...

01 Safety. IMPORTANT Be sure to have read and understood these instructions before beginning the installation process.

Wiring the fan correctly...

HOTLINE:

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

MODEL: DV72 R & L. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual

ECo 2 Wall USER GUIDE FOR RESIDENT

ECo 2 Wall INSTALLATION GUIDE FOR ENGINEER / INSTALLER

230V & SELV INSTALLATION GUIDE FOR ENGINEER / INSTALLER IPX4 IPX5

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

PIV & MIV Loft Mounted Unit INSTALLATION GUIDE FOR ENGINEER / INSTALLER

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems

Installation and Maintenance

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

energisava 200 High performance in a compact unit High Efficiency Whole House Heat Recovery System

Installation and Maintenance

Installation and Maintenance Instructions for the Installer. Please refer to the User Manual for instructions on how to operate the system

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Installation and Maintenance

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Installation and Maintenance

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Installation and Maintenance

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

ECO dmev Decentralised MEV

Installation and Maintenance

Intake air from outside. Supply air to house. Extract air. from house. Extract air from house. Exhaust air from house to outside

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

Watch the heatsava video

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

KUDOS. Instruction leaflet

Introducing the RetroVent

MRXBOX95-WH1. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Bracket

WHHR Midi & Midi Lite

Residential Carbon Friendly Ventilation SAP Q Eligible. ventilation

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

MRXBOX95-WM2H. Mechanical Ventilation Unit with Heat Recovery and Integral Humidistat for Wall Mounting Installation and Maintenance

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

Installation and Maintenance

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

Centrif Duo & Centrif Duo Plus

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

Lo-Carbon Quadra Centrifugal Fan

Fusion HRV2 Mechanical Ventilation with Heat Recovery User / Homeowner Guide

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

MRXBOX95-WM2. Mechanical Ventilation Unit with Heat Recovery for Wall Mounting Installation and Maintenance. Intake air from outside

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

Lo-Carbon SELV Tempra

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

Building Regulations 2010: What it means to you.

Code of Practice - Ventilation- Mechanical Extract Ventilation (MEV) + Mechanical Ventilation with Heat Recovery (MHVR)

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

HRX-aQ Range. Mechanical Ventilation with Heat Recovery appliances. Installation and Operating Instructions

MRXBOX95AB-WH1. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Wall Mounting. Installation and Maintenance

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

WHHR125DC - Aera. Whole House Mechanical Ventilation with Heat Recovery - MVHR

Itho Advance heat recovery ventilation unit. comfortable. indoor climate

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

Simply Silent Contour 4 (100mm) Axial Extraction Fan

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Lo-Carbon Sentinel Kinetic Horizontal

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

Green Line HRX. Mechanical Ventilation with Heat Recovery appliance. Installation and Operating Instructions

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

MODEL: BV400 Part No:

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

HR200WK Through the wall Heat Recovery Ventilator

SPECIFICATION casing manufactured from aludip steel in white low energy DC external motor aluminium plate heat exchanger

Xpelair Simply Silent TM DX100 Fan

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

Warnings, Safety Information and Guidance

Lo-Carbon Quadra SELV

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

100 FLUEBOOST

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

ART cm Island Curved Glass

Filterless Infinity Designed to Perform. Built to Last. WC, Bathroom & Kitchen

Lo-Carbon Quadra Centrifugal Fan

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

CLASSIC-100. Instruction leaflet. Instruction leaflet

Xpelair Simply Silent TM Contour Fan

Transcription:

You are about to install a product that is designed to outlast the life-cycle of the building. Once installed the unit will operate continuously for 5 years and beyond without a major service. Please therefore ensure that this product is treated with care and installed properly i.e. for the life of the building. If the unit is mishandled you might break it! This invalidates the warranty. And remember, if you have any problems please call our dedicated Technical Team. We are always pleased to help and in an emergency will come out to site quickly, completely free of charge. HOTLINE: Due to our policy of continuous innovation and improvement EnviroVent reserves the right to alter products specification and appearance without notice.

ABOUT THE UNIT The is a whole house heat recovery unit which works by continuously extracting stale, moisture-laden air from the Wet Rooms of the apartment or a house - the kitchen, bathroom and en-suite rooms - and ducts this to a central unit. This extracted air passes through a high efficiency counterflow heat exchanger before being ducted to the outside. Fresh air is drawn into the unit from outside, which is warmed by the heat exchange cell and delivered into the living, dining and bedroom areas. EXPLODED VIEW Spigot Mounting plate Heat recovery cell Fixing rods Front cover Motor assembly Front shell Drain Filter & Filter plugs

INSTALLATION INSTRUCTIONS IMPORTANT Be sure to have read and understood these instructions before beginning the installation process. PRE-INSTALLATION CHECK LIST Make sure that the unit can physically fit in to the desired location. The unit should be situated so that access for maintenance or replacement of parts is possible. Make the ductwork runs as short as possible. Having the most direct route and using as few bends as possible will reduce air resistance and improve the efficiency of the unit. SAFETY AND RECOMMENDATIONS All wiring must comply with Building Regulations and the current I.E.E. Wiring Regulations (BS7671) or the equivalent standards for your country. The final installation should be examined and tested by a qualified electrician. Precautions must be taken to avoid the backflow of gases into the dwelling from the open flue of gas or other fuel-burning appliances. Make sure the mains supply complies with the rating label for voltage, frequency and phase. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.

INSTALLATION INSTRUCTIONS FIRST FIX - Installing ductwork and electrical supply 1. Locate external terminations (supply and extract) in accordance with the latest addition of the Domestic Ventilation Compliance Guide. 2. Ductwork within house Ø125mm - maximise duct size where possible. Make sure that the ductwork is insulated in unheated spaces. Minimise flexible duct. 3. Locate the mains supply within 1m of the location of unit. The position of the electrical power supply or unit (a fused switched isolator) must not be mounted above or closer than 1m to a cooker where it could be affected by excessive heat or moisture. 4. Make sure that there is room for the MVHR unit. The unit is designed to be vertically mounted in a kitchen or utility cupboard (on the wall). It can also be floor mounted in a loft space with an additional drainage kit. EnviroVent Part number KIT-CONDENSATE-ES250. 5. Also make sure that there is a free space at the front of the appliance for cleaning the filter and carrying out maintenance on the appliance. Ducting Configuration See page 7 for duct connections to the unit/airflow directions Installed example, RH unit shown. A No exhaust within 2m of air inlet B Inlet duct from atmosphere C Outlet duct to atmosphere D MVHR E Ducts to and from property F Condense Drain

INSTALLATION INSTRUCTIONS SECOND FIX - Installing the unit 1. Fixing the unit. 3. Carefully remove the top foam moulding by pulling it straight forward. Foam mouldings must remain parallel. Take care not to damage the sealing gaskets. 2. Remove the front cover...held on with Velcro pads. Do not pull from one edge as this may damage the internal fixing rods. Laying the unit down on a stable surface remove retaining screws and washers x 4, store safely.

INSTALLATION INSTRUCTIONS SECOND FIX - Installing the unit 4. Fixing the unit. 6. Fix the mounting plate to the wall or joists with supplied fixings mounts and plugs. 4 5. Remove mounting rods and washers x4, store safely. Ensure that there is enough space for the condensate drain to be fitted and ducts to be connected. 4 tilt recommended. 7. Reassemble the case assembly unit to the mounting plate. Steps 5 and 4. 8. Prepare the drain. All MVHR units produce condensate. The condensation drain should be located at the lowest point in the foam moulding as shown overleaf. The drain can also be prepared before the case assembly is mounted. Stand the unit upright on a stable surface and carefully separate the case assembly from the back plate, leaving the fixing rods attached. Pull out the heat cell and decide drain location, see next page.

INSTALLATION INSTRUCTIONS SECOND FIX Airflow and drain fitting - LH Airflow and drain fitting - RH To Atmosphere From Atmosphere Extract from dwelling Supply to dwelling Supply to dwelling Extract from dwelling From Atmosphere To Atmosphere Wall mount Wall mount Ø20mm Saw Drill into the bottom of the case as shown Drill into the bottom of the case as shown

INSTALLATION INSTRUCTIONS SECOND FIX Connect 22mm PCV drain fitting The unit can be floor mounted in a loft space with an additional drainage kit. EnviroVent Part number KIT-CONDENSATE-ES250. When fitting the unit on its back make sure there is a minimum 4 down slope to ensure proper drainage of condensation. Foam casing Drill Ø20mm hole, removing plug and cleaning edges. Screw in the supplied drain fitting and silicon as appropriate to create a watertight seal. The drainage from the unit may be connected to an internal waste water system or soil pipe with an appropriate non-return device. One way valve device is recommended. Insulate pipes in an unheated loft space. U Bend One way valve IMPORTANT NOTE this unit is for Wall or Floor mount only. Ceiling mounting unit is configured differently and should be ordered separately. Floor mount Floor mount LH Drain Ø20mm Saw RH Drain Drill into the back of the case as shown Drill into the back of the case as shown

COMMISSIONING Electrical connections The appliance must be earthed. All wiring must completed by a qualified electrician. This appliance is suitable for 230v ~ 50Hz single phase supply fused at 3 amps. The appliance is supplied with a mains flexible cable (PVC sheathed, 6-core blue 1, yellow 2, white 3, green 4, black 5, and red 6) See next page. A double pole switch having a minimum contact separation of 3.0mm must be used to provide isolation for the unit. Typical settings It is recommended that Low (R1) is set as the base or trickle rate. Medium (R2) and High (R3) may be set as required. Unit airflow rates must meet Building Regulations Approved Document F. Settings must be recorded at commissioning for future reference. See page 11 for how to commission an MVHR Unit The fan speed control must not be mounted above or closer to 1m to the cooker where it could be affected by excessive heat or moisture. Fan speed controllers are supplied separately. Switch Positions Low (R1) Medium (R2) High (R3) Function 100% adjustable 100% adjustable 100% adjustable Remote Switch Positions (R4) (R5) 100% adjustable 100% adjustable

COMMISSIONING Wiring diagram Typical settings The adjustment panel can be found inside the control box. The potentiometer s range of movement is 270. Use an appropriately sized screwdriver to alter the potentiometer. Commissioning adjustments made to R1, R2, R3 affect both supply and extract fans simultaneously. See Pg 11 for how to commission an MVHR Unit.

COMMISSIONING Commissioning of a continuous running ventilation system - MVHR Commissioning of the system is necessary to provide adequate ventilation to the dwelling, as stipulated in Approved Document F (ADF) of the Building Regulations* Conditions All maintenance and development works should be completed prior to the commissioning of the unit, this is to avoid high levels of dust being drawn into the system and general disturbance to the setup. The unit should only be commissioned when fully installed, with power, ductwork, valves and vents in place. See Domestic Ventilation Compliance Guide. Equipment required Anemometer which is capable of measuring l/s or m³/hr. Commissioning method Once the previous conditions are met, High and Low rates need to be set. These should be set as outlined in the commissioning guide (page 10). Extract and Supply (Flow rates should be balanced on boost and trickle) Commissioning guide Boost rate (minimum high rate) Determine the whole building ventilation rate. See ADF of the Building Regulations. Open ceiling/wall valves. Measure all extract points summing the individual room rates. Measurements to be carried out with an appropriate anemometer. Adjust using fan speed using R1, R2, R3 until the total extract rate is met. See the individual product s instruction guide for method (page 10). When the desired overall rate is achieved, the individual valves should then be adjusted to draw the appropriate volume of air from each room, typically starting with the largest extract requirement first: kitchen, bathroom, utility room, en-suite and WC. It may be necessary to adjust the fan unit slightly to account for increased pressure. When adjustments are completed the valves should be locked into position to maintain settings. Trickle rate This should be set around about 75% of the Boost rate. See ADF of the Building Regulations. As the valves have been commissioned at high they will not need to be altered further, the Low rate should be adjusted up or down, until the lower extract rate is met. See the individual product s instruction guide for method on page 10. For guidance on good installation practice for MVHR systems see the latest edition of the latest edition of the Domestic Ventilation Compliance Guide*. This guide provides in depth information on all aspects installation, inspection, testing and commissioning. * Applicable in England and Wales. For other countries please refer to your local building regulations.

Checklist to ensure Guaranteed Installed Performance Installation instructions have been understood Ductwork is Ø125mm or larger with no more than 10% flexi used (90% ridged) All ducts, vents and diffusers are securely connected & sealed, with supply and extract filters in place The unit is securely fixed into position with enough space left for servicing Condense drain is tight, drains to a suitable location and has been water tested All major building works have been completed prior commissioning Supply and extract have been commissioned to meet Part F of the Building Regulations with a calibrated anemometer Commissioning data has been recorded Inform building owner/user on how to operate and maintain the system These checks are required to ensure the proper function of this unit. For EnviroVent Technical help call 01423 810 810

MAINTENANCE Filters x 2 Part number FILTERES250 Filter cover Front cover General advice It is recommended that airflows at the diffusers are periodically checked by the resident or home owner. Filter Maintenance - to be checked as required. 6 months recommended 1. Switch off the power supply 2. Remove front panel 3. Remove filter covers 4. Remove the filters 5. Vacuum the outside of the filter 6. After cleaning replace filters at same side 7. Replace filter covers and front panel 8. Always ensure that the date is recorded on the reverse of the front cover. Major service This is to be carried out at five years by EnviroVent or approved maintenance company.

TECHNICAL DATA Maximum Flow Rate Heat Exchanger 250m 3 /hr Counter Flow (Plastic) Efficiency 91% Fans SFP Electrical Supply Max Power Consumption Protection Class Supply Filter Extract Filter Spigot ø Dimensions Weight EC (Electronically Commutated DC) 0.60 W/I/s 230V / 1PH / 50Hz 140W IPX2 G3 G3 125mm 560 x 635 x 260mm 14kg PERFORMANCE CURVE

SOUND DATA Kitchen + Additional Wet Rooms +1 +2 +3 +4 +5 Airflow Volume (I/s) 15.0 21.0 27.0 33.0 39.0 Breakout Noise Level db(a) @3m 21 24 28 32 36 Inlet Noise Level db(a) @3m 21 22 24 26 30 Outlet Noise Level db(a) @3m 30 34 37 41 44 APPROVALS Applied Standards Low Voltage Directive (2006/95/EC) EMC Directive (2004/108/EC) EN 60335-1:2002 EN 600335-2-80:2003 EN 55014-1:2006+41:2009 EN 61000-3-2:2006 EN 61000-3-3:2008

Warranty CONDITIONS AND EXCLUSIONS The EnviroVent is covered by a full 5 year warranty which will benefit the occupier over many years. In the event that the product requires servicing, maintenance or reaches the end of its useful life, the quick, simple component replacement programme will ensure minimal disruption - no re-wiring, no drilling or dust. What should I do if I have a problem? If, after thoroughly reading this booklet, you feel that your unit is not working correctly, you can telephone the number shown at the bottom of this page (operational from 9:00am to 5:00pm Monday to Friday), and ask for technical assistance. We appreciate you choosing this quality EnviroVent product, which is designed and manufactured to the highest specification in Harrogate, North Yorkshire. We are confident that you will be delighted with the performance of the system and the resulting improvement in air quality in your home after the installation of the unit. However, it is important that you register your purchase (see overleaf). This will ensure the prompt and efficient handling of any communication in the event that your unit requires attention during the 5 year warranty period. Your warranty covers any defect or break down that arises due to faulty materials or construction. The system must be correctly installed and operated according to the instructions contained in the user guide supplied. The warranty will be rendered invalid if the system has been serviced, maintained, repaired, taken apart or tampered with by any person not authorised by EnviroVent Ltd. The warranty will be rendered invalid if the unit is turned off. Turning the unit off can damage it. The warranty does not cover accidental damage, misuse or abuse. The warranty is in addition to your statutory or legal rights. The warranty will only be honoured from approved suppliers.

GUARANTEE REGISTRATION FORM AND 5 YEAR WARRANTY Our Warranty Statement If within 5 years of installation, the unit breaks down, we will repair it - free of charge. Please sign and return this form to register your warranty. Dear Customer, You have an unit installed in your home. It is designed to give you many years of trouble free use. Nothing on this form will affect your statutory rights. Name of occupier: Address of property: Date of installation: Type of unit installed: Serial number of unit: Postcode: Signature: Type of property (detached etc): Telephone number (if available): Delivering innovative and sustainable ventilation solutions worldwide Please read carefully to ensure simple installation and a long trouble free life for the user. AFTER INSTALLING THIS FAN PLEASE PASS ONTO END USER - DO NOT THROW AWAY EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate HG2 8PA T 01423 810 810 F 01423 810 910 E info@envirovent.com www.envirovent.com

Please read carefully to ensure simple installation and a long trouble free life for the user. AFTER INSTALLING THIS FAN PLEASE PASS ONTO END USER - DO NOT THROW AWAY EnviroVent Ltd EnviroVent House Hornbeam Business Park Harrogate HG2 8PA T 01423 810 810 F 01423 810 910 E info@envirovent.com www.envirovent.com E&OE MKT ENV270-V1-17.09.13 Due to our policy of continuous innovation and improvement EnviroVent reserves the right to alter products specification and appearance without notice.