SAFETY, STRUCTURES AND FIRE DEPARTMENT Reaction to Fire REACTION TO FIRE CLASSIFICATION REPORT No. RA140063 ACCORDING TO THE EUROPEAN STANDARD NF EN 135011+A1:2013 Notification by the French Government to the European Commission under no 0679 Seule la version française fait foi The French version is legally acceptable Product standard ETA Guide no. 034 (2012): Kits for external wall claddings Owner: Commercial brand(s): Manufacturing unit(s): ALCOA ARCHITECTURAL PRODUCTS S.A.S. 1 rue du Ballon 68500 MERXHEIM FRANCE (riveted system and cassette system) The manufacturing unit appears in the associated tests report Brief description: Cladding made of composite panels (see detailed description in paragraph 2) Date of issue: April 03 rd, 2014 The indicated classification does not prejudge the conformity of marketed materials with the samples submitted to the tests and under no circumstances, this document should not be considered as type approval or certification of the product in the sense of the L 11527 to L 11533 and R 1151 to R 1153 articles of the consumption s code. If this report is being issued by email and/or on an electronic medium, only the hard copy of the report signed by CSTB shall prevail in the event of a dispute. The reproduction of this classification report is only authorised in its integral form. It comprises 5 pages.
2/5 Classification report No. RA140063 1. Introduction This classification report defines the classification assigned to the abovementioned product(s) in accordance with the procedures given in the NF EN 135011+A1:2013 standard. 2. Product description Cladding system. Composite panel consisting of two precoated aluminium sheets thermally bonded together with a polyethylene film. Tested systems: riveted on metal substructure and cassette on metal substructure. Finishes: 35 µm or PVDF 70/30 35 µm. Nominal thickness of the aluminium facings: 1.47 mm. Overall nominal thickness: 3 mm. Colour: beige.
3/5 Classification report No. RA140063 3. Tests reports and tests results in support of this classification 3.1 Tests reports Name of laboratory Name of sponsor Test identification Test report No. Test method CSTB ALCOA ARCHITECTURAL PRODUCTS S.A.S. 1 rue du Ballon 68500 MERXHEIM FRANCE ES541130441 RA140063 EN 13823:2002 EN ISO 1716:2002 3.2 Tests results Results Test method Product Number of tests Parameters Continuous parameters Mean values Compliance parameters Riveted system finish 35 µm thick 3 FIGRA 0.2MJ (W/s) FIGRA 0.4MJ (W/s) LFS THR 600s (MJ) SMOGRA(m²/s²) TSP 600s (m²) 0.4 11.5 Not reached EN 13823 Cassette system finish 35 µm thick 1 Flaming droplets or debris FIGRA 0.2MJ (W/s) FIGRA 0.4MJ (W/s) LFS THR 600s (MJ) SMOGRA(m²/s²) TSP 600s (m²) None 0.4 22.2 Not reached Flaming droplets or debris None EN ISO 1716 External nonsubstantial component 3 Internal nonsubstantial component (per component) PCS (MJ/m 2 ) 0.8 PCS (MJ/m 2 ) 3.5 Product on its whole (worst case: 35 µm finish) PCS (MJ/kg) 0.6 () means: not applicable
4/5 Classification report No. RA140063 4. Classification and direct field of application 4.1 Reference of the classification This classification has been carried out in accordance with clauses 11.7.3, 11.9.2 and 11.10.1 of the NF EN 135011+A1:2013 standard. 4.2 Classification Fire behaviour Smoke production Flaming droplets or debris A2 s1, d0 Classification: A2 s1, d0 4.3 Field of application This classification is valid for the following product parameters: The system described in paragraph 2. An overall nominal thickness of 3 mm. 35 µm thick and 35 µm thick PVDF 70/30 finishes. This classification is valid for the following end use conditions: Riveted or screwed system and cassette system on metal substructure. Without insulating material or with any A1 or A2s1,d0 class mineral wool insulating material behind the metal substructure With or without air gap. Without substrate or with any A1 or A2s1,d0 class substrate with a density 652 kg/m 3.
5/5 Classification report No. RA140063 5. Limitations The present document does not represent type approval or certification of the product. The classification assigned to the product in this report is appropriate to a declaration of performance by the manufacturer within the context of system 3 attestation of conformity and CE marking under the European Construction Products Regulation (regulation UE no. 305/2011). The manufacturer has made a declaration, which is held on file. This confirms that the products design requires no specific processes, procedures or stages (e.g. no addition of flameretardants, limitation of organic content, or addition of fillers) that are aimed at enhancing the fire performance in order to obtain the classification achieved. As a consequence the manufacturer has concluded that system 3 attestation is appropriate. The test laboratory has, therefore, played no part in sampling the product for the test, although it holds appropriate references, supplied by the manufacturer, to provide for traceability of the samples tested. ChampssurMarne, April 03 rd, 2014 The Technician Responsible for the test The Head of Reaction to Fire Unit Maxime BAUER Gildas CREACH..END OF THE CLASSIFICATION REPORT