INTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

Similar documents
ADVANCED EXTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

SOUTHERN AFRICAN EMERGENCY SERVICES INSTITUTE NPC Registration No. 2014/162285/08. Interior Industrial Fire Brigade Member- NFPA 1081, 2007

AIRPORT FIRE FIGHTER ID#: STANDARD:

INCIPIENT FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

FIREFIGHTER II MANIPULATIVE SKILL OBJECTIVES

Pro Board Assessment Methodology Matrices for NFPA 1001

Additional Materials: Instructor s PowerPoint, Question Files

Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition.

Based on NFPA 1003: Standard for Airport Fire Fighter Professional Qualifications 2015 Edition

SPEARFISH FIRE DEPARTMENT POLICIES AND PROCEDURES

FIRE PROTECTION BUREAU ACCREDITATION AND CERTIFICATION PO Box Olympia WA (360) FAX: (360) AIRPORT FIREFIGHTER

FIREFIGHTER II: FIRE DEPARTMENT COMMUNICATIONS COMMUNICATIONS: SKILL SHEET #2 Define and Demonstrate Fire Department Radio Procedure

Cumru Township Fire Department 4/27/10 Standard Operating Guidelines Page: 1 of 6 Section 15.07

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

FIREFIGHTER 1 COMPETENCY EVALUATION

Essentials of Fire Fighting, Fourth Edition Transition Guide. Chapter 1: The History of the Fire Service (Essentials, Chapter 1)

Required Materials For complete material(s) information, refer to

Skill Sheet 17-I-1. Suppress an interior structure fire Direct, indirect, or combination attack. (NFPA 1001, , )

EASTERN ARIZONA COLLEGE Fire Department Operations II

Rapid Intervention Team

NFPA Fire Fighter I (Including Entry Level Fire Fighter) Task Book

Standardized Curriculum Form Ontario, Canada

FIREFIGHTER 1 COMPETENCY EVALUATION

I. It shall be the responsibility of the department officers to implement this operating guideline.

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

Second Revision No. 1-NFPA [ Section No. 2.2 ] Submitter Information Verification. Committee Statement

San Joaquin County Office of Education Career & Technical Education Fire Fighter Technology CBEDS#: 5833

Structural Firefighting Policy

FRS 101 INTRODUCTION TO FIRE SERVICE 45 CLOCK HOURS 3 CREDIT HOURS. Course Title Lecture/Skill Total Fractional Credit

SOUTHERN AFRICAN EMERGENCY SERVICES INSTITUTE NPC Registration No. 2014/162285/08. Fire Fighter 1 - NFPA 1001, 2008

EASTERN ARIZONA COLLEGE Fire Department Operations I

9S / 9E Inspection Worksheets. The fire department should complete the following sheets prior to inspection date

CHAPTER 05 - OFFICE OF STATE FIRE MARSHAL SUBCHAPTER 05A - FIRE AND RESCUE SECTION.0900 PUBLIC PROTECTION CLASSIFICATIONS FOR FIRE DISTRICTS

S Fire Fighter II. Supplementary Material: Performance Test. Air Force Institute for Advanced Distributed Learning

BROWNSVILLE VOLUNTEER FIRE DEPARTMENT

SUBJECT FIRE OPERATIONS GUIDELINE (F.O.G.) #F510 Issued: 1/2014 Last Revision: 1/2014 Pages: 9 By Order Of: J.S. Thompson, Fire Chief

Excerpted from NFPA 1403 Standard on Live Fire Training Evolutions

Length of Course: 32 Hours Lecture/Lab Breakdown: 14/18

CENTRAL CALAVERAS FIRE AND RESCUE TRAINING DIVISION CAREER TRAINING AND DEVELOPMENT FIREFIGHTER II STANDARDS

MASTER COURSE OUTLINE

DEPARTMENTAL GUIDELINES CHAPTER 6 TACTICAL OPERATIONS

Career Fire Fighter Dies While Exiting Residential Basement Fire - New York

First Revision No. 1-NFPA [ Section No ] Submitter Information Verification. Committee Statement 4/15/ :08 AM

Summary. firefighter training in Since that time the firefighter had attended semi-annual

FIRE FIGHTER I. Fire Fighter I Training Record Page 1. July 2001 NAM E: APPROVED INSTRUCTOR INITIALS and DATE UNIT A

FRS 201. Firefighters Advanced Skills I. 45 clock hours 3 credit bouts

STANDARD: 5.2.1(B) TASK:

FREDERICK COUNTY / WINCHESTER FIRE AND RESCUE DEPARTMENTS BASIC FIRE ACADEMY #15 CERTIFICATION COURSE SEPTEMBER 2015 APRIL 2016

Program of Instruction Course Syllabus

ATTIC FIRES. Part 2 LIGHT SMOKE SHOWING

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 High Rise On Scene Revised

1 Pre-Burn Plan Mandatory. 2 Pre-Burn Inspection Mandatory. 3 Pre-Burn Briefing Mandatory. 4 Instructor In Charge Mandatory

Enactment Date: Rapid Intervention Team and RIT Officer

Elko County Human Resources Employment Opportunity Announcement

VOLUNTEER FIRE FIGHTER Certification Training Record

Lassen Community College Course Outline

FIRE FIGHTER II NFPA 1001, Chapter 6, 2013 Edition

Airport Firefighter Recertification Core Competency Task Book

Travis County Emergency Services District #1 Standard Operating Guidelines

ATTIC FIRES. Part 3 HEAVY SMOKE SHOWING

Carbon Monoxide Poisoning

Lamorinda CERT - Unit 2 09/15/2016

PATTERNS OF FIREFIGHTER FIREGROUND INJURIES

Dawson Creek Fire Department A Street BC V1G 3V7 PH : (250) FAX : (250)

SKILL VERIFICATION BOOK FIREFIGHTER I MODULE II FIRE PROTECTION BUREAU. Assigned to: Name:

MATRIX TO DETERMINE YOUR PRESENT POSITION IN MEETING N.F.P.A. 1720

Chapter 3 FF II Fire Department Communications

Fire Department Orientation / Organization

Centers for Regional Excellence. Downriver Fire Authority. Organization Committee Objective. Operations Committee Report 2007

Talking about NFPA History of NFPA NFPA Standard 1710: Organization and Deployment of Fire Suppression Operations, EMS

Rescues individuals in danger from fire, vehicle accidents, industrial accidents and other situation requiring extraction.

Fire Fighter I Certification Training Standards Guide [Month Year]

San Ramon Valley Fire Protection District GREEN SHEET

COMMISSION ON FIRE PROTECTION PERSONNEL STANDARDS AND EDUCATION COMMONWEALTH OF KENTUCKY FIREFIGHTER 2 COMPETENCY EVALUATION

DCN: ENGINE COMPANY OPERATIONS CHAPTER 4 March 15, 1997 FIRE SCENE OPERATIONS

INSTRUCTOR GUIDE COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 1 TOPIC: ORIENTATION AND FIRE BEHAVIOR LEVEL OF INSTRUCTION:

Township Of Jackson, Fire District 3, Station 55 Standard Operating Guidelines FIRE GROUND STRATEGY

Chapter 18 Test. Directions: Write the correct letter on the blank before each question.

I. INTRODUCTION. A. Purpose: To provide procedures and guidelines for personnel responding to and operating at working structure fire incidents.

Death in the line of duty

Prerequisite/Co-requisite: Pass the reading and writing portions of COMPASS or other accepted testing instrument.

ADDISON COUNTY FIREFIGHTERS ASSOCIATION MUTUAL AID SYSTEM STANDARD OPERATING GUIDELINES

GREEN SHEET. Los Angeles Fire Department. Informational Summary Report of Serious LAFD Injuries, Illnesses, Accidents and Near-Miss Incidents

Saskatchewan Evaluation and Certification Guide. Appendix D

Massachusetts FD Fire Fighter Task Survey Analysis Fire Fighter Essential Tasks: COMMONWEALTH OF MASSACHUSETTS FIRE FIGHTER TASK LIST

1.1.0 Protocols for the response to fires involving MRI Machines

Program of Instruction Course Syllabus

CHAPTER 1 ADMINISTRATION AND ORGANIZATION

RE: BASIC FIRE SAFETY PROCEDURES AND OPERATION OF FIRE EQUIPMENT

COUNTY OF BERGEN DEPARTMENT OF PUBLIC SAFETY LAW AND PUBLIC SAFETY INSTITUTE POLICE, FIRE & EMS ACADEMIES 281 Campgaw Road Mahwah, N.J.

LEBANON COUNTY FIRE SCHOOL STRUCTURAL BURN BUILDING USAGE MANUAL

Public Comment No. 3-NFPA [ Chapter 7 ]

VOLUSIA COUNTY FIRE CHIEFS ASSOCIATION MODEL OPERATING GUIDELINE

Travis County Emergency Services District #1 Standard Operating Guidelines

Public Safety Institute Fire & Rescue Course Fee Catalog

71717 SERIES FLAMMABLE MATERIAL LOCATIONS

3330 N Clayton. C - Side Date: 11/18/2017 Time: 21:48 Incident Number: Address: 3330 N Clayton

FIRE AND FIRE FITTING By Mr. Prashant Sansare

FIRE FIGHTER I/II CERTIFICATION COURSE SYLLABUS

Travis County Emergency Services District #1 Standard Operating Guidelines

Transcription:

INTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL 1- Utilize a pre-incident plan so that the industrial fire brigade member implements the responses detailed by the plan. NFPA 1081, 2012 Edition, 7.1.2.3, 7.2.7, 7.3.9 Given pre-incident safety plan(s) and an assignment. Identify the following on a pre-incident plan - Water supply - Extinguishing agents (systems) - Site specific hazards - Automatic fire suppression systems - Radio communications, dispatch channel - Radio communications, tactical channel - Rapid Intervention Crew (RIC) - Incident management System structure Identify the following Mutual Aid recourse as part of the preincident safety plan. - Responding team off-site - Response time from off-site - Public or private organizations responding - Interface Personnel Accountability System Plan Louisiana Emergency Responder Certification System 18

MANUAL FIRE SUPPRESSION 2- Identify components of thermal protective clothing and demonstrate the donning, doffing and maintenance of equipment. NFPA 1081, 2012 Edition, 7.1.2.1 Given thermal protective clothing; hood, boots, gloves, coat, and pants. Don hood (hood maybe rolled down around collar of coat) Don and fasten all closures on pants/boots and coat Collar turned up on coat/hood rolled down on collar Don helmet and tighten chin strap (helmet ear flaps down) Don gloves Doff protective clothing and place back in-service 1:00 Minute to Don (No time limit for doffing) 3- Demonstrate the donning of a Self-Contained Breathing Apparatus (SCBA). NFPA 1081, 2012 Edition, 7.1.2.1 Given thermal protective clothing (Donned) and SCBA. Crouch or kneel at SCBA (if donned from ground) Check SCBA cylinder pressure gauge (verbalize pressure) Open cylinder valve fully Don Backpack and fasten/tighten all straps (over-the-head or coat method) Don facepiece, adjust head harness, check seal and exhalation valve Don protective hood Connect regulator to facepiece or low-pressure hose to regulator Turn on or ensure PASS is active Don helmet, gloves 2:00 Minute Louisiana Emergency Responder Certification System 19

4- Demonstrate emergency procedures in the event of SCBA failure by conserving air by skip-breathing technique and controlled breathing technique. NFPA 1081, 2012 Edition, 7.1.2.2, 7.1.2.2(a)(b) Wearing full protective clothing and SCBA. Inhale normally (as during regular breathing) Holds breath (as long as it would take to exhale) Inhale again Exhale slowly 1:00 Minute 5- Demonstrate routine maintenance procedures for an in-service SCBA: Inspect, clean, and sanitize an SCBA system. NFPA 1081, 2012 Edition, 7.1.2.2, 7.1.2.2(a)(b) Given an SCBA and cleaning solution specified by manufacturer Inspection and cleaning of SCBA and Facepiece: Inspect SCBA and facepiece Wash facepiece and sanitize (verbalize sanitation procedure) Rinse in fresh water, hang to dry Wash/rinse backpack (keep water from entering regulator) Replacement of SCBA Cylinder on SCBA Frame: Place SCBA on ground, close cylinder valve Obtain full cylinder Disconnect regulator from facepiece or low-pressure hose from regulator Relieve excess pressure from regulator Release clamp on bottle and remove cylinder from frame Check pressure on new bottle (verbalize pressure reading) Place new cylinder in frame and secure clamp or closure Check high-pressure hose O-ring Connect high-pressure hose to cylinder Open cylinder valve and check for leaks Check cylinder and regulator gauges-should read within 100 psi of each other Close cylinder valve and relieve excess pressure from regulator, listen for low-pressure alarm Fully extend all straps on SCBA backpack Fully extend all straps on facepiece Louisiana Emergency Responder Certification System 20

6- Attack an INTERIOR STRUCTURE fire operating as a member of a team so that team integrity is maintained and the fire is brought under control and all hidden fires are exposed and extinguished. NFPA 1081, 2012 Edition, 7.2.1, 7.2.1(a)(b), 7.2.2, 7.2.2(a)(b), 7.2.6, 7.2.6(a)(b), 7.2.3, 7.2.3(a)(b), 7.2.4, 7.2.4(a)(b), 7.2.5, 7.2.5(a)(b), 7.3.7, 7.3.7(a)(b) Given a water source, 1½- handline, PPE, SCBA, forcible entry tools or access keys/cards, and an assignment. Operate as a member of a team Establish a water supply from hydrant, or other source Deploy attach line for advancement Access is gained to the fire area Nozzle is operated in safe manner Appropriate fire stream is applied to situation Appropriate fire attack is used: direct, indirect, combination Fire is extinguished Ventilation is performed to remove fire gases and improve visibility Search for hidden fires using; sight, touch, sound, or electronic sensors. With appropriate tool open walls, ceilings, and floors to expose hidden fire. Expose void spaces without compromising structural integrity. Use water as needed to extinguish hidden fires as found. Fire cause evidence is preserved Team integrity is maintained during evolution 7- Conduct a search and rescue operation as a member of a team so that all victims are located and removed and team integrity is maintained. NFPA 1081, 2012 Edition, 7.2.8, 7.2.8(a)(b), 7.3.7, 7.3.7(a)(b) Given PPE/SCBA, forcible entry tools, flashlight, 1½- handline and an assignment. Operate as a member of a team Select correct forcible entry tool(s), force entry as needed Enter hazardous area Begin primary search pattern (left or right hand) Maintains contact with team by sight, hearing or physically Maintain contact with IC, notify command of progress Locate and remove victims Exit hazardous area as a team Louisiana Emergency Responder Certification System 21

8- Conserve property while operating as a member of a team so that exposed property and the environment are protected from further damage. NFPA 1081, 2012 Edition, 7.2.9, 7.2.9(a)(b), 7.3.7, 7.3.7(a)(b) Given special tools, salvage covers, and an assignment. Conserve property by using salvage covers deployed over items, building openings covered, automatic sprinkler systems or special protection systems disabled after fire is extinguished 9- Operate as a member of a rapid intervention crew (RIC) during firefighting operations in an IDLH or possible IDLH environment exist. NFPA 1081, 2012 Edition, 7.2.10, 7.2.10(a)(b), 7.3.7, 7.3.7(a)(b) Given PPE/SCBA, radio, forcible entry tools, flashlight, and an assignment. Operate as a member of a RIC Conduct size-up of incident and determine equipment needs Select correct tools Determine staging area Monitor operations of IC and interior crews Maintains contact with IC Initiate rescue operations of down/lost firefighter if needed Enter hazardous area Conduct rescue operations as needed Rescue firefighter and exit hazardous environment to safe area Exit hazardous area as a team Louisiana Emergency Responder Certification System 22

SITE-SPECIFIC 10- Perform a fire safety survey of a facility so that fire and life safety hazards are identified, recommendations for their correction are made and unresolved issues are referred to the proper authority. NFPA 1081, 2012 Edition, 7.3.10, 7.3.10(a)(b) 7.1.2.3, 7.1.2.3(a)(b) Given an assignment, survey forms and procedures. Obtain correct form(s) to conduct fire survey and identify the following information on form: - Building area, exterior and interior - Fire protection systems - Life safety issues - Flammable liquids storage area - Electrical sources and shut offs - Built in fire protection barriers - Method of access to all areas of facility 11- Utilize master stream appliance so that the agent is applied to the fire as assigned. NFPA 1081, 2012 Edition, 7.3.3, 7.3.3(a)(b), 7.3.7, 7.3.7(a)(b) Given an assignment, a master stream device and an extinguishing agent. Correctly identify type of master stream device (wagon pipe, deluge set, monitor pipe, ladder pipe) Operate master stream device by adjusting water flow, nozzle pattern, angle of stream and location as needed based on assignment Open and close appropriate valves and not cause water hammer Louisiana Emergency Responder Certification System 23

12- Extinguish an ignitable liquid fire operating as a member of a team so that the correct proportioned foam is selected for the given fuel, applied and the fire is extinguished. NFPA 1081, 2012 Edition, 7.3.4, 7.3.4(a)(b), 7.3.7, 7.3.7(a)(b) Given an assignment, PPE, handline, foam proportioning device, nozzle, foam concentrate, water source and a 4-member team. Select nozzle, hose, foam, and water source (Includes proper foam selection for hydrocarbon or polar solvent) Positions attack and backup line for suppression activities Establish water source Assemble foam stream components Prepare foam concentrate, verifying type and percentage Checks flow of water and removes air in line (Includes flowing until foam appears and matching nozzle gpm setting with eductor gpm requirements) Approach fire from upwind position in a safe manner Apply agent in method that extinguishes fire, creating foam blanket Retreat from the fire/spill in a safe manner maintaining team integrity Maintain team communication and integrity 13- Control a flammable gas fire operating as a member of a team so that crew integrity is maintained, contents are identified, flammable gas source is controlled or isolated. NFPA 1081, 2012 Edition, 7.3.5, 7.3.5(a)(b), 7.3.7, 7.3.7(a)(b) Given an assignment, PPE, handline, nozzle, water source and a 4- member team. Identify emergency exit routes Selects nozzle, hose and adequate water source capable of supplying two 250-gpm lines Positions attack and backup lines for suppression activities Checks flow of water and removes the air in the line Approach fire from upwind position if possible Uses fire streams to control fire spread and cool tank Operates tank control valves to shut off fuel Extinguishes fire (only if gas flow is shut off) Continues cooling tank while exiting area as a team Louisiana Emergency Responder Certification System 24

14- Extinguish an exterior fire using special extinguishing agents (other than foam) while operating as a member of a team so that fire is extinguished. NFPA 1081, 2012 Edition, 7.3.6, 7.3.6(a)(b), 7.3.7, 7.3.7(a)(b) Given an assignment, PPE, SCBA, handline, nozzle, special agent (dry chemical, dry powder of carbon dioxide) and a 2-member team. Conduct size-up of scene Choose correct extinguisher Activate the extinguishing system Tests extinguisher prior to approaching fire Back-up team in place before proceeding to extinguish fire Approach fire in a safe manner (up wind if possible) Apply agent in manner that extinguishes fire Fire is extinguished and re-ignition prevented Exits area as a team, observing conditions 15- Interpret alarm conditions so that the alarm condition is correctly interpreted and a response is initiated. NFPA 1081, 2012 Edition, 7.3.1, 7.3.1(a)(b) Given an alarm signaling system, a procedure and an assignment. Identify detection system Interpret type of alarm; Emergency or Trouble or Supervisory Alarm or Fixed Gas Detection Initiate response following procedures of facility 16- Activate a fixed fire suppression system so that the correct steps are followed and the system operates. NFPA 1081, 2012 Edition, 7.3.2, 7.3.2(a)(b) Given PPE, a fixed fire protection system, a procedure and an assignment. Identify fixed fire suppression system Operate controls to monitor, activate, or shutdown system as assigned Louisiana Emergency Responder Certification System 25

17- Extinguish a Class C (electrical) fire as a member of a team so that the correct agent is used and the fire is extinguished. NFPA 1081, 2012 Edition, 7.3.11, 7.3.11(a)(b), 7.3.7, 7.3.7(a)(b) Given an assignment, PPE, SCBA, a Class C fire-extinguishing appliance/extinguisher, and a 2-person team. Conduct size-up of scene Verify correct extinguisher De-energize electrical equipment involved (lock-out/tag-out) Tests extinguisher prior to approaching fire Approach fire in a safe manner (up wind if possible) Apply agent in manner that extinguishes fire Fire is extinguished and re-ignition prevented Exits area as a team, observing conditions 18- Demonstrate the proper carry, position, raise and lower of straight (roof) or 24 ft. or 35 ft. extension ladder. NFPA 1081, 2012 Edition, 7.3.8, 7.3.8(a)(b), 7.3.7, 7.3.7(a)(b) Given an assignment, PPE, Roof Ladder or 24 ft. extension ladder (2-Firefighter team) or 35 ft. extension ladder (4-Firefighter team). Start 50 ft. from structure Leader gives prepatory commands Team lifts with legs Proper carry to structure Check for overhead obstructions (must verbalize) Determine structure stability (must verbalize) Raise fly section to proper height Determine locks are engaged (must verbalize) Tie off halyard Check climbing angle Lower ladder to ground 3:00 Minutes (Lowering ladder not included in time) Louisiana Emergency Responder Certification System 26

19- Demonstrate procedure for climbing, working from, and descending a ladder. SAFETY ALERT: NFPA 1081, 2012 Edition, 7.3.11, 7.3.11(a)(b) Given an assignment, PPE, Roof Ladder or 24 ft. extension ladder (2-Firefighter team) or 35 ft. extension ladder (4-Firefighter team). LADDER HEELED BY SECOND FIREFIGHTER OR TIED OFF Check climbing angle of ladder Climb with arms straight, body perpendicular to the ground Climb smoothly and rhythmically Maintain three points of contact with ladder while climbing Carry tool properly Lock-in around rung or use safety harness Lock-in on opposite side from the working side 2:00 Minute Louisiana Emergency Responder Certification System 27