RAM GENE / RAM GENE-1

Similar documents
RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

Nuclear Associates

Dosimeters/Survey meters

Contamination Meter Users Manual

Identify the following features and specifications for the ESP1

LUDLUM MODEL and PANCAKE CLUSTER DETECTORS. June 2016

LUDLUM MODEL ALPHA, BETA, GAMMA HAND DETECTOR. June 2016 Serial Number and Succeeding Serial Numbers

LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR. February 2010 Serial Number PR and Succeeding Serial Numbers

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

LUDLUM MODEL AND LUDLUM MODEL ALPHA, BETA, & GAMMA DETECTORS

LUDLUM MODEL 44-7 Alpha, Beta, Gamma Detector. July 2012 Serial No. PR and succeeding Serial Numbers

LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL. October 2014 Serial Number and Succeeding Serial Numbers

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

Ranger EXP RADIATION A L E R T

LUDLUM MODEL 26-1 FRISKER USER S MANUAL. April 2017 Serial Number PF and Succeeding Serial Numbers

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

Portable Survey Instruments NISP-RP-01

TRACERCO T402 and T402HR USER MANUAL

LUDLUM MODEL 26 FRISKER USER S MANUAL. December 2016 Serial Number PF and Succeeding Serial Numbers

Radioactivity dosimeter RD01. User's Manual

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

LUDLUM MODEL 52 PORTABLE PORTAL MONITOR. November 2011 Serial No and Succeeding Serial Numbers

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

DIGITAL AREA RADIATION MONITOR

MODEL OX-07 Type A INSTRUCTION MANUAL FOR RIKEN PORTABLE OXYGEN MONITOR PT0E-0860

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

ATOMLAB XENON TRAP MONITOR OPERATION AND INSTALLATION MANUAL FN: /12

SENSIT HXG-2d Combustible Gas Detector

Kata products Kata DGM-1500 Turva

TRACERCO Radiation Monitor

HIn3550 Magnetic Field Monitor User's Manual

Surface Contamination Monitor. Operation Manual

MINI-RADIAC INTRODUCTION

LUDLUM MODEL 3276 SERIES FRISKER/AREA MONITOR USER S MANUAL. November 2017 Serial Number: and Succeeding Firmware: 49830n30 and Higher


DOE 2.17 Contamination Monitoring Instrumentation Study Guide. 00ICP330 Rev. 0 Page 1 of 23

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

Radiation Alert Frisker INTERNATIONAL

WBGT Heat Stress Meter

SGA71. Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

Using the GammaRAE II Personal Radiation Detector

TRACERCO Radiation Monitor. Instruction and Maintenance Manual for Model No. T202

MODEL AND MODEL GAS PROPORTIONAL DETECTORS. December 2016 Serial No and Succeeding Serial Numbers

LUDLUM MODEL 35 SERIES DIGITAL SURVEY METER USER S MANUAL

Controls Surface mounted pushbuttons Suitable for gloved use. Buttons Side - On/Off Front Menu Scroll Pin Hole Setup access

RadEye B20 RadEye B20-ER Multi-Purpose Survey Meter

Radioactive Contamination Monitor

Personal Radiation Alarm Dosimeter LK Operating Instruction Manual. Contents

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

Victoreen Primalert 35 Area Radiation Monitor

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

MicrOTDR. Optical Fault Locator. User Manual

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

USER GUIDE Heat Index Psychrometer

Caliber Series LED Edgelit Exit Sign EXPORT AC Only or Emergency Operation READ AND FOLLOW ALL SAFETY INSTRUCTIONS

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

PERSONAL COMBINED RADIATION DETECTOR/DOSIMETER РМ1703МО-1 OPERATION MANUAL

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

RD99 REFRIGERANT GAS LEAK DETECTOR WARNING!

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Counting Scales. HC-i Series.

testo 316-EX gas leak detector Instruction manual

Area Monitor/Frisker Count Rate Meter Victoreen

Leak-Seeker I Refrigerant Leak Detector

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

MODEL 951 RADIATION DETECTOR

Portable Oxygen Monitor OX-07. (Type A) Operating Manual

T82. Instruction Manual. Single Gas Monitor GUARANTEED. FOR LIFE. P/N REV 0 PRINTED ,000 Specifications Subject to Change

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

PRELIMIN INTERNATIONAL

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

Operation Guide 3408

KANE-ALERT-CO 2 Monitor with Temperature

Operating Instructions

Model ATD Refrigerant Gas Leak Detector. User Manual. Detects all CFC, HFC, HCFC, HFO Refrigerants including blends

Radiation Monitoring Systems

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Sirius Technologies, Inc.

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

COMPASS S3 S2 CALIBRATION

LD-5000 REFRIGERANT LEAK DETECTOR

FlameGard 5 UV/IR HART

EVac II Programmable Digital Vacuum Gauge

FOR BOTH CONVENTIONAL AND HEAT PUMP SYSTEMS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT!

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

Dual-Diode Dosimeter Patient Dose Monitor

ANALOX 101 D2 PORTABLE OXYGEN MONITOR USER MANUAL

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

RAD-60 USER GUIDE (ALSO FOR THE RAD-50 MODEL AND ISOTRAK DOSIMETERS)

LD920. User Manual. H2/N2 Tracer Gas Leak Detector. Detects 5% H2 in 95% Nitrogen Tracer Gas. Made in U.S.A. LeakDetectors-LD920-UserManual.

HOBO U14 Data Logger User Manual

Transcription:

RAM GENE / RAM GENE-1 Radiation Meters Operating Manual Document #PRIR69N0.DOC Version 6.1 - December 2000 ROTEM INDUSTRIES LTD. ROTEM Industrial Park P.O.Box 9046, Beer-Sheva 84190, ISRAEL Tel: 972-8-6571312/6568652 Fax: 972-8-6555984/6568005 E-Mail: sales@rotemi.co.il Web Site: http://www.rotemi.co.il

Version / Revision Log: RAM GENE / RAM GENE-1 - Operating Manual Ver./Rev.# Date Revised Pages Comments 6.0 June 1996 Doc. # BM9420.WP (N14) 6.1 November 2000 Doc. # PRIR69N0.DOC (WORD issue) 1-3 Updated ROTEM address, addition of this log, updated table of contents 10-11, 16 Segment replaced with LCD s This manual is not to be considered a public document, and is not available for general distribution. Its distribution is limited to company employees and customer consultants of RAM GENE radiation meter, for the sole purpose of the RAM GENE operation. The contents of this manual may not be disclosed to other persons in any form, or reproduced wholly or partially, without the prior written consent of Rotem Industries. WARNING: For air delivery, the detector should be placed in a sealed container to ensure gradual changes in pressure, which otherwise may cause irreparable damage to the GM tube. ROTEM Industries Ltd. reserves the right to change specifications without advance notice. RAM GENE / RAM GENE-1 Operating Manual Page 2

Table of Contents 1. RAM GENE... 4 1.1 General Description... 4 1.2 Ordering Information... 5 2. Specifications... 6 3. Operating Instructions... 9 3.1 Preparation for Use... 9 3.2 Starting-up... 9 3.3 Collimators usage... 9 3.4 General functions... 9 3.5 Threshold Selection... 10 3.6 Alarms... 11 3.7 Battery Replacement... 12 4. Calibration... 13 4.1 Calibration with a Contamination Source... 13 Appendix 1 - Operating Instructions and Technical Data for RAM GENE-1... 15 Appendix 2 - RAM GENE-1 from Version 950725-5899... 16 RAM GENE / RAM GENE-1 Operating Manual Page 3

1. RAM GENE 1.1. General Description The RAM GENE radiation contamination meter is designed to detect very low levels of alpha, beta and gamma surface radiation contamination. RAM GENE-1 can be switched to measure radiation field in mr/h or ìsv/h units. Two versions of instruments are available for RAM GENE: cps and cpm. Four versions of instruments are available for RAM GENE- 1: cps + mr/h, cpm + mr/h, cps + ìs/h, cpm + ìs/h. The RAM GENE meter is a state-of-the-art microprocessor based instrument, equipped with a recessed internal GM pancake detector of 1.75" effective diameter, with a thin mica window covered by a protective stainless steel wire mesh screen. The meter is a one-hand-operation instrument, portable, lightweight and compact. Only three pushbuttons are needed for operation: ON/OFF, RESET for accurate measurement of low level contamination, and SPEAKER push-button for audible indicator volume control. Changing of the units in RAM GENE-1 (cps to mr/h) is performed by pressing the RESET and SPEAKER pushbuttons simultaneously. Three ways of indications enable the RAM GENE user to monitor and survey surface contamination rapidly and accurately: a large four 7-segment LCD, an audible click whose rate varies directly with count rate, and a LED indicator that flashes with each incident radiation pulse. The sophisticated software offers special features and optimal performance. A wide dynamic range of up to 42,000 counts per second or 999,000 counts per minute in RAM GENE / GENE-1, and background to 700 mr/h (7000 ìsv/h) in RAM GENE-1, is obtained by the automatic dead time correction, according to the preset calibration. A special averaging function softens the readout and maintains fast response time, while keeping the standard deviation at a minimum. An automatic self-diagnostic procedure continuously checks both, meter and detector, and reports any case of detector failure. The meter also alarms in any case of a reading exceeding threshold value, reading overflow or low battery. Threshold can be selected from a range of 10 preset threshold values. When the meter is turned off, the last threshold value and the calibration factor are kept in memory. The RAM GENE meter can be placed in a holder. The detector surface is covered with a cap for protection against mechanical damage. A set of four detector s collimators: 5, 10, 15, and 25 mm in diameter, is available upon request (See Figure 1-1). Inserting a collimator plate between the detector and its cover decreases the effective diameter, and consequently the count rate reading. For the RAM GENE-1 an additional aluminum disk is supplied, and it is placed at the front of the detector for radiation field measurement. RAM GENE / RAM GENE-1 Operating Manual Page 4

Figure 1-1. RAM GENE Detector View and Collimators Set 1.2. Ordering Information Item Description Model No. RAM GENE [cps] (including holder and cover cap) 4-0010 RAM GENE [cpm] (including holder and cover cap) 4-0010-01 RAM GENE-1 [cpm + mr/h] 4-0015-01 RAM GENE-1 [cpm + ìs/h] 4-0015-02 RAM GENE-1 [cps + mr/h] 4-0015-03 RAM GENE-1 [cps + ìs/h] 4-0015-04 Holder A-0100 Pancake wire mesh protective screen A-0140 Pancake hexagonal protective screen A-0141 GM pancake detector cover cap A-0060 Set of detector collimators A-0050 Aluminum disk for RAM GENE-1 A-0210 Detector tester A-0070 Belt hanger for RAM GENE / GENE-1 A-0180 Case for RAM GENE / GENE-1 A-260 RAM GENE / RAM GENE-1 Operating Manual Page 5

2. Specifications Display LED Audio Measuring unit Controls Power source Detector Window thickness Background reading Sensitivity ( 137 Cs) Count rate range Accuracy Temperature range Humidity range LCD readout showing: - four digits for accurate and easy readout - detector failure - low battery - overflow - threshold Count rate indication Internally mounted piezo-electric element RAM GENE: cps or cpm RAM GENE-1: cps or cpm, mr/h or ìsv/h - ON/OFF push-button - RESET push-button - SPEAKER push-button One 9-volt cell battery - 50 hours minimum continuous operation, using an alkaline battery (speaker off) - Automatic battery check under full load Pancake GM tube (LND 73118 or equivalent) Effective diameter 1.75" Mica, 1.5 to 2 mg/cm² protected by a stainless steel wire mesh 0 to 1 cps 50 cpm Approx. 5.8 cps/ìsv/h (58 cps/mr/h) Approx. 350 cpm/ìsv/h (3500 cpm/mr/h) 0 to 42,000 cps 0 to 999,000 cpm ±15% of reading Operation: -10 C to +50 C (15 F to 122 F) Storage : -20 C to +60 C (-5 F to 140 F) 40% to 95% RH (non condensing) RAM GENE / RAM GENE-1 Operating Manual Page 6

Casing High impact plastic Dimensions Width 6.7 cm (2.6") Length 11.0 cm (4.3") Height 7.4 cm (2.9") Weight 340 g (0.75 lb) Surface sensitivity (in contact) for cps units: Isotope Energy E or Emax kev Sensitivity kcps/ìci Surface Sensitivity cps cps 10-4 ìci/cm² Bq/cm² Minimum Detectable level* pci/cm² Bq/cm² 14 C (β) 156 0.67 1 0.25 250 9 35 S (β) 167 1.64 2.5 0.65 100 3.7 147 Pm (β) 224 3.1 4.8 1.25 55 2 99 Tc (β) 290 4.22 6.5 1.75 40 1.5 90 Sr+ 90 Y (β) 580+2280 20.56 30 8.5 8 0.3 36 Cl (β) 714 8.7 13 3.5 20 0.7 210 Pb (β) 1160 9.97 15 4 17 0.6 32 P (β) 1710 13.25 20 5.5 13 0.5 51 Cr (ã) 325 0.0424 0.06 0.017 4000 150 99m Tc (ã) 140 1.12 1.7 0.45 150 5.5 125 I (ã) 35 0.097 0.15 0.04 1700 63 131 I (β) 610 7.56 11 3 22 0.8 230 Th (á) 4600 2.7 4 1 60 2.5 241 Am (á) 5400 2.7 4 1 60 2.5 * Minimum detectable level calculations are based on background reading of 1 cps, and the confidence level is 99%. RAM GENE / RAM GENE-1 Operating Manual Page 7

Surface sensitivity (in contact) for cpm units: Isotope Energy E or Emax kev Sensitivity kcpm/ìci Surface Sensitivity cpm cpm pci/cm² Bq/cm² Minimum Detectable level* pci/cm² Bq/cm² 14 C (β) 156 40 0.6 15 125 5 35 S (β) 167 95 1.5 40 50 1.9 147 Pm (β) 224 180 2.8 75 28 1 99 Tc (β) 290 253 3.9 105 40 0.75 90 Sr+ 90 Y (β) 580+2280 1230 18 500 4 0.15 36 Cl (β) 714 520 7.8 200 10 0.35 210 Pb (β) 1160 590 9 240 9 0.3 32 P (β) 1710 790 12 330 7 0.25 51 Cr (ã) 325 2.5 0.036 1.0 2000 75 99m Tc (ã) 140 65 1.02 25 75 2.8 125 I (ã) 35 5.8 0.09 2.4 850 32 131 I (β) 610 450 6.6 180 11 0.4 230Th (á) 4600 160 2.4 60 30 1.3 241 Am (á) 5400 160 2.4 60 30 1.3 Minimum detectable level calculations are based on background reading of 50 cpm, and the confidence level is 99%. RAM GENE / RAM GENE-1 Operating Manual Page 8

3. Operating Instructions 3.1. Preparation for Use Remove the instrument from the shipping container and check for physical damage. In case of damage, report it immediately to the carrier. Do not attempt to install or operate damaged equipment since safety and performance may be affected 3.2. Starting-up Press the ON/OFF push-button. When the meter is turned on, it carries out a short selftest procedure indicated by displaying all the segments on the display, and emitting a beep for a short period. Now the meter is ready for use. 3.3. Collimators usage The detector collimators set includes four plates of different hole diameter: 5, 10, 15, and 25 mm. Choose one plate from the collimators set and insert it between the detector surface and its cover; count rate will be decreased. 3.4. General functions a. Readout: The measuring units are counts per second or counts per minute. Values through 9999 cps or cpm are expressed in 1 to 4 digits. For higher values, up to 42,000 cps or 999,000 cpm, a factor of 1000 will be indicated by displaying E. For example: 10,400 = 10.4E 127,000 = 127E b. LED: A LED indicator, located above the LCD, flashes with each incident radiation pulse. c. Reading reset: To reset the reading press the RESET push-button. The reset function provides a rapid means of discharging the display and enables accurate measurement of low level contamination. d. Audible indication: When the meter is turned on, the audible indication is activated at its high volume, so that the rate and trend of measurement are noticed. To turn the speaker off, press the SPEAKER push-button. This volume control is sounded especially at low rates of measurement. RAM GENE / RAM GENE-1 Operating Manual Page 9

3.5. Threshold Selection Threshold value can be selected from a range of 10 threshold values. The selected value is also kept in memory after the meter is turned off. The following threshold values may be selected: 3, 4, 5, 6, 7, 70, 80, 200, 300, 42.000 [cps] 200, 250, 300, 350, 400, 1000, 5000, 10.000, 20.000, 999.000 [cpm] To choose the required threshold value, proceed with the following steps: 3.5.1. Enter threshold mode by pressing the RESET push-button for two seconds. The reading will be zero, and later on the thr. LCD s will be displayed to indicate that the threshold setting mode is activated. 3.5.2. Pressing the SPEAKER push-button displays the existing threshold value. 3.5.3. Each additional press on the SPEAKER push-button displays the next threshold value, according to the order described in section 3.4. 3.5.4. To exit set threshold mode and to save the new threshold value, press the RESET pushbutton for 2 seconds. Saving will be verified by an audible beep and blinking of the threshold value. 3.5.5. To exit the set threshold mode without saving new values (cancel threshold change), press RESET push-button for a very short period (less than 2 seconds). Threshold value blinks and no beep will be sounded. RAM GENE / RAM GENE-1 Operating Manual Page 10

3.6. Alarms a. Detector alarm: If the detector is defective or disconnected, the Err. LCD s blinks on the display and an interrupted audible alarm is activated. To mute the audible alarm, press the SPEAKER push-button. b. Battery alarm: If battery voltage decreases below 6.2V, the bat. LCD s blinks on the display, and an interrupted audible alarm is activated. To display the measured readings and mute the audible alarm, press the SPEAKER pushbutton. After the SPEAKER push-button is pressed, the bat. LCD s will reappear every five minutes for 2 seconds, and every 30 minutes accompanied by an audible beep to remind of low battery condition. c. Overflow alarm: If the displayed count rate is over 42.0E (42.000 cps) or 999E (999.000 cpm), the OFLO LCD s blinks on the display and an interrupted audible alarm is activated. To mute the audible alarm, press the SPEAKER push-button. d. Threshold alarm: If the reading exceeds threshold value, the ALr. LCD s and the reading are displayed alternately, accompanied by an audible beep. Pressing the SPEAKER push-button mutes the audible alarm, but the ALr. LCD s and the reading are continuing to be displayed alternately, until the reading decreases to 0.75 from threshold value. In case the reading exceeds threshold value and then decreases below 0.75 of threshold value, the ALr. LCD s and the beep sound are automatically canceled, even though the SPEAKER push-button has not been pressed. RAM GENE / RAM GENE-1 Operating Manual Page 11

3.7. Battery Replacement The battery compartment is located at the back of the instrument. To replace the battery, slide out the battery compartment cover carefully. Use one 9-Volt alkaline battery; be sure to connect it with the right polarity. Figure 3-1. RAM GENE Battery Compartment RAM GENE / RAM GENE-1 Operating Manual Page 12

4. Calibration 4.1. Calibration with a Contamination Source Calibration should be performed by an authorized technician. To calibrate the RAM GENE meter, use dip-switch U9 on PC #1803. 4.1.1. Expose the detector to a 99 Tc * source whose activity is 50 to 250 Kdpm. 4.1.2. Check the RAM GENE reading and compare it with the expected reading. For example: 100 Kdpm 99 Tc should give 15000 cpm for copper beryllium screen and 10000 cpm with stainless steel wire mesh screen. If the difference is lower than 10%, the detector is calibrated. If the difference is higher than 10%, perform the following steps: a. Loosen the 4 screws located on the meter's back. b. Open the case and turn the internal switch to the calibration position. (Turn dip-switch 1 to ON position). The Cal. LCD s will be displayed. c. Press the SPEAKER push-button once, the reading and factor values will flash alternately on the display (the factor is indicated by the letter F, e.g. F 1.23). d. Expose the unit to a known radiation field and calculate the new factor. Old factor * Radiation field New factor = ------------------------------------! Instrument reading e. Press the SPEAKER push-button to increase the factor value (meter reading) and the RESET push-button to decrease the factor value (meter reading). The display will return to the alternate mode only when either SPEAKER or RESET push-button is not pressed for more than 3 seconds. f. When the required reading (factor) is obtained, turn the internal switch back to the measuring position and the meter will enter the measuring mode. The calibration factor is a value between 0.60 to 1.40 stored in the EEPROM. g. Check again the meter reading in the above radiation field. RAM GENE / RAM GENE-1 Operating Manual Page 13

Figure 4-1. CPU Card * If a different source is used, other than 99 Tc, the meter has to be calibrated against a known expected value based on detector efficiency for the specific isotope. RAM GENE / RAM GENE-1 Operating Manual Page 14

Appendix 1 Operating Instructions and Technical Data for RAM GENE-1 1. The operating instructions for RAM GENE-1 are identical to those of RAM GENE, except for the following points: 1.1 On switching on the RAM GENE-1, the measuring unit is cps or cpm (for measuring radiation contamination). 1.2 Change-over to mr/h or ìsv/h units (for measuring the radiation field) is done by pressing the RST and SPK keys simultaneously. 1.3 Change back to cps units is done by pressing RST and SPK simultaneously. 2. Measuring the radiation field should be done with the aluminum disk at the front of the detector. Place the disk inside the plastic cover and attach it to the front of the instrument. 3. Field radiation measurement range: 0.001mR/h to 700mR/h (0.01ìSv/h to 7000ìSv/h). Figure 1. RAM GENE-1 Radiation Meter RAM GENE / RAM GENE-1 Operating Manual Page 15

Appendix 2 RAM GENE-1 from Version 950725-5899 Updated Changes and Additions for Previous Versions: 930504, 930217, 930218 Thresholds Threshold Selection Threshold value can be selected from a range of 10 threshold values. The selected value is also kept in memory after the meter is turned off. The following threshold values may be selected: 3, 4, 5, 6, 7, 70, 80, 200, 300, 42.0E [cps] 200, 250, 300, 350, 400, 1000, 5000, 10.0E, 20.0E, 999E [cpm] To choose the required threshold value, proceed with the following steps: 1. Enter threshold mode by pressing the RESET pushbutton for two seconds. The reading will be zero, and later on the thr. LCD s will be displayed to indicate that the threshold setting mode is activated. 2. Pressing the SPEAKER push-button displays the existing threshold value. 3. Each additional press on the SPEAKER push-button displays the next threshold value, according to the order described above. 4. To exit set threshold mode and to save the new threshold value, press the RESET push-button for 2 seconds. Saving will be verified by an audible beep and blinking of the threshold value. 5. To exit the set threshold mode without saving new values (cancel threshold change), press RESET push-button for a very short period (less than 2 seconds). Threshold value blinks and no beep will be sounded. Threshold alarm If the reading exceeds threshold value, the ALr. LCD s and the reading are displayed alternately, accompanied by an audible beep. Pressing the SPEAKER push-button mutes the audible alarm, but the ALr. LCD s and the reading are continuing to be displayed alternately, until the reading decreases to 0.75 from threshold value. In case the reading exceeds threshold value and then decreases below 0.75 of threshold value, the ALr. LCD s and the beep sound are automatically canceled, even though the SPEAKER pushbutton has not been pressed. RAM GENE / RAM GENE-1 Operating Manual Page 16

Merging All the RAM GENE-1 Versions Four versions of RAM GENE-1 were available: cps + mr/h, cpm + mr/h, cps + µs/h, cpm + µs/h. Until now each version included a separate EPROM. The RAM GENE-1 new version is adequate for all the four versions. Setting the Units Perform a long press (for 10 sec.) on the SPEAKER push-button. One of the following readings will be displayed, each defining the instrument s operating units: U11 - cps + mr/h U12 - cps + µs/h U21 - cpm + mr/h U22 - cpm + µs/h A short press on the SPEAKER push-button enables transition between the units. An additional long press (for 10 sec.) returns the instrument to the measurement mode. Data Storage When turning off, the meter s data including threshold value, factor value and units code, is stored in the EPROM. Hardware In order to apply this new version, the following changes should be performed on the standard micro board (PC #1803): 1. Insert the U1-X24C04 component. 2. U9 dip-switch mode should be as depicted below: jmp 5 4 3 2 1 5 6 7 8 jmp 5 - open 4 and 5 - short 2 and 7 - open 2 and 6 - short 1 and 8 short for calibration Note: Do not change dip-switches position (2-7, 3-6, 4-5). Any change in one of the dip-switches will interrupt the meter's correct operation. Reminder: 1. To pass between the contamination units and field units, press the RESET and SPEAKER push-buttons simultaneously. 2. Maximum readings: 42,000 cps 999,000 (999E) cpm 700 mr/h 7000 ìsv/h RAM GENE / RAM GENE-1 Operating Manual Page 17

RAM GENE / RAM GENE-1 Notes: RAM GENE / RAM GENE-1 Operating Manual Page 18