The following is a University standard specification and shall be reviewed and edited by the Design Professional to be project specific.

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

SECTION WATER-SOURCE UNITARY HEAT PUMPS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

SECTION ROTARY-SCREW WATER CHILLERS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer

MINI-ROOM COOLERS, FREEZERS & COMBINATIONS

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

AIR COOLED PACKAGED CHILLER

DeCA DESIGN CRITERIA HANDBOOK PRODUCT REFRIGERATION SYSTEM

SECTION AIR COOLED WATER CHILLERS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

NOR-LAKE, INCORPORATED 727 Second Street Hudson, Wisconsin 54016

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Commercial High-Efficiency Condensing Units

Liebert CSU3000 Chiller

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

.2 Section Waste Management and Disposal.

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

MAC-120HE-03 Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

Wall mount refrigeration systems available. PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations. KaTom Restaurant Supply, Inc.

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

NFZP Variable Refrigerant Flow Guide Specification

Wall mount refrigeration systems available. PRS-2 SERIES Packaged Refrigeration Systems & Walk-in Combinations

SECTION ROTARY SCREW WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

SECTION CENTRIFUGAL WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

roof finish is 26 gauge acrylic coated stucco galvanized steel.080 textured aluminum interior floor finish, where required

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

PACKAGE AIR CONDITIONER

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

10-Bilt. Walk-In Coolers & Freezers With Matching Refrigeration Systems FEATURES OPTIONS

INSULATED COLD STORAGE ROOMS (FOAMED IN-PLACE INSULATED PANELS)

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

MAC N-407 Air-Cooled Chiller

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

30GT FLOTRONIC AIR-COOLED CHILLERS

Walk-Ins & Refrigeration Systems

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Environmental Chamber Specifications

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

water to water heat pumps

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

INSULATED COLD STORAGE ROOMS (FOAMED IN-PLACE INSULATED PANELS)

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

"N-Width" Reach-In Refrigerator-Freezer Models/Self-Contained. Project Quantity Item # Model Specified: CSI Section 11400

Kold Locker Walk in Standard walk in stocked for IMMEDIATE SHIPMENT

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

StableClimate Stability Chambers

EQUIPMENT SNOW DOMES / SKI DOMES

QUICK SHIP Walk-In Coolers & Freezers With Matching Refrigeration Systems SEE INSIDE

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

MEDICAL CHILLER SYSTEMS

commercial refrigeration products

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION

SECTION ROTARY SCREW WATER CHILLERS. B. Removal of Existing Refrigerant in Existing Chiller:

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

30GN FLOTRONIC II AIR-COOLED CHILLERS

Standard Model Coolers, Freezers and Combination Cooler/Freezers In Stock for SAME DAY SHIPMENT

C. Samples for Initial Selection: For units with factory-applied color finishes.

WALL-MOUNT HEAT PUMPS - (60HZ)

SpaceKeeper Console (SKC)

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

User s Information and Installation Instructions

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

DES MOINES PUBLIC SCHOOLS MADISON WALK-IN COOLER/FREEZER PROJECT. 806 E. Hoffman Street Des Moines, IA ADDENDUM NO.

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

1.1 This section applies to air handling units for HVAC Systems.

Installation 50% Service 20% Components 20% Applied Knowledge 10%

Transcription:

13 12 00 FOUNTAINS A. Due to water conservation efforts and the high maintenance requirements of fountains, new interior and / or exterior fountains are not allowed. B. If a variance is granted for a fountain, it shall be connected to the sanitary sewer system and shall not connect to the storm sewer system. FOUNTAINS APRIL 30, 2018 13 12 00-1

13 21 00 A. Related sections: i. 23 00 00 General Mechanical Requirements (HVAC) ii. 26 00 00 General Electrical Requirements B. Intent: i. The guide is for the purpose of assisting the design engineer with specifying environmental rooms, walk-in coolers and / or freezers used in research or for educational purposes. This guide specification is not intended for food storage walk-in coolers. ii. The unit shall be provided by a single-source manufacturer and the manufacturer shall be ISO 9001 registered. 2. PRODUCTS A. Acceptable manufacturers are: i. Nor-Lake, Inc. ii. Harris Environmental iii. Thermmax Scientific Products B. Insulated Panels / Walls / Roof i. The environmental room shall be pre-fabricated and field assembled and shall consist of modular, interlocking, pre-insulated panels. The panel insulation shall be polyurethane rigid foam and the thickness shall be sized to prevent condensation on the exterior and shall be no less than 4 inches thick. Sufficient gasketing shall be provided to stop moisture migration. ii. Floor panels shall be designed to withstand 600 pounds per square foot pressure minimum. iii. Adjoining environmental rooms operating at different conditions shall not share panels, but shall be independent of one another. (No shared roof, floor or wall panels). C. Doors i. The door shall have an anti-sweating heater wire around the perimeter to prevent sweating, an observation window and a kick-plate. D. Ramps i. Discuss with UGA project manager whether a ramp is needed and if so should it be internal or external to the unit. E. Interior floors shall be provided with tread plate covering to reducing slipping. F. Condensing units shall not be mounted atop the cooler unless it is water-cooled. If mounted atop unit, a minimum of 36 inches clear from the top of the unit to structure is required. In addition, adequate clearances for access and maintenance shall be provided. Air-cooled units shall be installed remotely outdoors unless specifically approved by Project Manager. G. Electrical: i. The environmental room shall have a single point of power connection in a NEMA 1 cabinet containing circuit breakers for lights, outlets and cooler located directly above the controls. APRIL 30, 2018 13 21 00-1

ii. Lighting shall be designed to maintain to provide 70 foot candles. Lights shall be gasketed and all associated hardware designed to operate in a damp location without rusting. All wiring shall be concealed in conduit inside the panels. iii. Provide 2 duplex receptacles per wall minimum unless otherwise instructed. Discuss locations with Project Manager. H. Controls: i. Discuss with Project Manager to ensure what design conditions are needed. Many environmental rooms are designed for 4 degrees Celsius, but others may vary depending upon the department. Others may require dehumidification and / or dehumidification. ii. Programmable microprocessor controls for temperature and humidity control shall be encased in a lockable panel with an acrylic cover. Temperature and humidity shall be displayed via a liquid crystal alphanumeric display. iii. The controllers shall have sufficient outputs and inputs to interface with alarms or other devices as required. iv. The controller shall be provided with the capability of generating e-mail or text messages to identified individuals via the internet in the case of the cold room operating outside set parameters. a. Coordination with the FMD IT Department will be required for installation of associated software and for programming of individual text and e-mail addresses. b. Coordination with campus EITS to provide data cable drop for transmission of alarm text or e-mail. v. Provide low and high limit safeties to prevent over cooling or over-heating and shall generate audible and visual alarms. High and low safeties shall be provided with automatic resets rather than manual resets. vi. Paper chart recorders are generally not desired. vii. Product sample temperature sensors shall be provided with protective cover. I. Alarms: i. Provide audible and visual alarms. J. Water-Cooled Condensing Units: i. The condensing unit shall be indoor type. ii. The compressors shall be hermetic. iii. Indoor water-cooled condensing unit accessories include: iv. Water regulating valve for head pressure control v. Coaxial condenser selected for the proper EWT, and condensing temperature. K. Outdoor Condensing Units: i. The condensing units shall include pre-painted galvanized cabinet, compressor, condenser, fan motors, liquid receiver with fusible plug, compressor service valves and waterproof electrical control panel. The assembly shall be designed for outdoor use. ii. The compressors shall be serviceable semi-hermetic or scroll type iii. Outdoor condensing unit accessories shall include: a. Head pressure control valve b. Crankcase heater c. Compressor contactor APRIL 30, 2018 13 21 00-2

d. Dual pressure switch e. Liquid shut-off valve and charging port f. Liquid line filter / drier & sight glass g. Suction filter h. Defrost timer iv. Condenser coil constructed of copper tube with plate type, die formed aluminum fins. v. Condenser fans to be propeller fans arranged for horizontal discharge, the fans shall be statically and dynamically balanced. vi. Accessories common to all evaporators: a. Electric heat for defrosting copper tubes and aluminum fins b. heavy gauge textured aluminum casing c. Sweat connection d. Schrader valve for suction pressure measurement e. Thermally protected PSC motors f. Thermostatic expansion valve g. Liquid line solenoid for automatic pump down. L. Accessories: i. If the cold room is provided with a sink (not recommended), then all water lines and drain lines shall be heat traced and insulated. M. Acceptable manufacturers are: i. Nor-Lake, Inc. ii. Harris Environmental iii. Thermmax Scientific Products 3. EXECUTION: A. The installing technicians shall provide proof of experience in installing pre-fabricated environmental rooms. Provide proof of installation of at least 10 similar units. B. The installing Contractor shall verify that the floor upon which the environmental room shall sit is level before constructing the room and that all walls are plumb. C. The Contractor shall provide a minimum of 30 days of trend data indicating stable control of design parameters (temperature and humidity). D. A factory employee or factory designated individual shall be present at start-up. E. Warranties: i. Warranty shall become effective following the acceptance date and cover the following items for the noted duration: a. Five-year compressor warranty b. One-year parts warranty c. 18-month labor warranty APRIL 30, 2018 13 21 00-3

13 34 19 METAL BUILDING SYSTEMS A. Introduction: Metal Building Systems are generally used in rural or agricultural settings, and the design intent is for the metal building form to emulate the shape of a barn. B. The roof shall be a gable form with a minimum 6 in 12 slope. C. Overhangs of at least 12 inches are required on all sides of the building. D. Vinyl soffits are not allowed. E. The roof color and material shall be equal to Galvalume (55 percent aluminum-zinc alloy coated sheet steel). F. The siding color shall be a medium gray and color samples shall be submitted to the Project Manager for approval. G. All roof penetrations shall utilize a pre-manufactured boot and / or sleeve that is specifically designed for a metal building roof system. METAL BUILDING SYSTEMS APRIL 30, 2018 13 34 19-1