RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Similar documents
RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

ETL Testing Laboratories, Inc.

The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

PERFORMANCE TEST REPORT. Rendered to: VELUX America, Inc. PRODUCT: SUN TUNNEL Acrylic Dome

Flammability Test Results

CAN/ULC-S109 Flame Resistance of "Argo" Fabric

CAN/ULC-S109 Flame Resistance of "Xanadu" Material

Technical Training International Textiles Training September 2018 Ellen Roaldi Instructor

TECHNICAL BULLETIN Weston Parkway, Cary, North Carolina, Telephone (919) FLAMMABILITY TESTING: A REVIEW BY COTTON INCORPORATED

Global flammability standards.

National Fire Protection Association

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

Test Method of Specified Requirements of FTTS-FA-015. Flame-Resistant Textiles

We Identify and S.T.O.P. Your Noise Problems

PERFORMANCE TEST REPORT. Rendered to: PALRAM AMERICAS, INC. PRODUCT: Clear Palsun TYPE: Polycarbonate

FIRE RETARDANT ARCHITECTURAL WOOD COATING FIRE SHIELD FS020 FIRE-SHIELD SEALER. FS021 FIRE-SHIELD TOP COAT Available in different gloss

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process

Analysis Report

Illuminating Label Laws 2015 Manufacturing Summit Franklin Furniture Institute Mississippi State University

BCTC CARPET TECHNICAL CENTRE

Demolition Permit Application (Please print and complete ENTIRE form)

TEST REPORT. Report No.: D Rendered to: 3M COMPANY St. Paul, Minnesota

PRODUCT PERFORMANCE TEST REPORT. Report No.: D Test Date: May 29, Rendered to: Natural Light Energy Systems Phoenix, Arizona

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

Contents Page No. Page 1 of Introduction Specimen verification Description of supporting constructions...


Report Of Surface Burning Characteristics Tests On Fire Retardant Coating As Submitted By Contego International

Report Test Report

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

BURNING BRAND PERFORMANCE TEST REPORT. Rendered to: VELUX AMERICA, INC. SERIES/MODEL: TGF/TGR (Acrylic Dome) VELUX SUN TUNNEL

UL 94 Flammability Ratings: Introduction

SOLI VINYL. Type II. Photo: Wallcovering Soli ACW Tequila Sunrise #14

Public Comment No. 1-NFPA [ Section No ]

Report Of Surface Burning Characteristics Tests On Samples As Submitted By Ebrille SRL

EXIT ROUTES, EMERGENCY ACTION PLANS, AND. FIRE PREVENTION PLANS. PART 1: INTRODUCTION

First Revision No. 2-NFPA 90B-2012 [ Section No. 1.3 ] Submitter Information Verification. Committee Statement and Meeting Notes

EnviroScape Mural. pre-pasted printable wallcovering material. Choose your GREEN resource from a leading solutions provider.

Benefiting Government, Industry and the Public Through Innovative Science and Technology. Barry L. Badders, Jr. P.E.

Flame Retardant Science and the Furniture Industry: A Success Story. February 2015

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

REGULATIONS FOR OUTDOOR GATHERINGS AND EVENTS TENTS & MEMBRANE STRUCTURES

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU TENANT IMPROVEMENT GROUP A FIRE PLAN REVIEW CHECKLIST

Los Angeles International Airport Rules and Regulations SECTION 08 FIRE AND SAFETY

EXTINGUISHMENT AND BURNBACK TESTING OF FIRE FIGHTING AGENTS

FORM MUST BE SIGNED AND RETURNED FOR VENDOR PARTICIPATION

ASTM E 662 Rate of Smoke Generation of OXIFREE TM198"

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

Test Report No. AJD Date: JUN.09, 2013 Page 1 of 6

DEMYSTIFYING FR CLAIMS: AN ERGODYNE WHITE PAPER

1303 Trans Canada Way SE Medicine Hat, AB T1B 3Z9 Phone

(h) Pesticide Application.

DUAL MIRROR ALUMINIZED FABRICS. Protection You Can Count On. Value You Can t Beat.

FIRE TESTING SERVICES FIRE TESTING SER

ARTICLE 25. FUEL GAS CODE

Fire Safety in a Laser Lab

Contents: 4. Report of Surface Burning Characteristics Tests on LP FlameBlock/BlazeGuard (30-minute test) Updated April, 2010

RECYCLED GREEN BASE CLOTHS

~ 0."0... DESCRI PT ION OF TEST SAM PLE

Test Report: ICL/H18/9039 Rev 1

FABRICS. Messenger 4 Revive 1 Revive 2

UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS

SHAW CONTRACT DESCRIPTION OF TEST SAMPLE

CENTRAL STATE HOSPITAL PLAN SAFE USE HANDLING AND STORAGE OF FLAMMABLE AND COMBUSTIBLE LIQUIDS

Flame Resistant Clothing: Statistics, Standards and Safety

HAWAII ADMINISTRATIVE RULES DEPARTMENT OF LABOR AND INDUSTRIAL RELATIONS DIVISION OF OCCUPATIONAL SAFETY AND HEALTH GENERAL INDUSTRY STANDARDS

CEC CODE COMPLIANCE SEMINAR FOR ICC CHAPTER 8 INTERIOR FINISHES & DECORATIVE MATERIALS

A comprehensive systems-level approach in cabin design minimizes fire potential and helps ensure passenger safety. aero quarterly qtr_04 11

Note To The User: This product has updated features not yet mentioned in the product manual.

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

GUIDELINES FOR INSPECTING GROUND BASED SPARKLING DEVICE (GBSD) RETAIL SALES FACILITIES

Report Of Surface Burning Characteristics Tests On Coated Louvered Door Panels As Submitted By Contego International Inc.

FABRITRAK SYSTEMS, INC. FIRE TEST REPORT

ASTM E84-99 ADHERED SURFACE BURNING CHARACTERISTICS

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

DEPARTMENT OF DEFENSE DESIGN CRITERIA STANDARD

The Cannabis Industry: Fire Department Requirements

FIRE PREVENTION IN THE USE OF CUTTING OR WELDING PROCESSES

Report Of Surface Burning Characteristics Tests On Felt Material As Submitted By Rieke Office Interiors

Flame retardant. Protectivewear fabrics by Klopman International

Residential Water Heater Alteration or Replacement Requirement Per the 2016 California Energy Code (CEC)

TEST REPORT. Report No.: E Test Date: May 6, Rendered to: FUNDERMAX GMBH A-9300 St. Veit an der Glan, Austria

PLASTICS WORKSHOP ENGINEERED. Learn About Thermoplastics Connect with Experts WESTBOROUGH / MASSACHUSETTS (BOSTON AREA)

Life Safety Code Potpourri

50A Integrated Furnace Control

SECTION REGULATORY REQUIREMENTS. A. Relationship between Code, Ordinances, Standards and Contract Documents

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

UNDERSTANDING THE CHANGES TO CALIFORNIA TB ON FLAME RETARDANCE OF RESILIENT FILLING MATERIALS USED IN UPHOLSTERED FURNITURE

RENDERED TO. Radial Engineering Limited 1588 Kebet Way Port Coquitlam, B.C. V3C 5M5

Vescom bv Sint-Jozefstraat AV Deurne Nederland

OCFEC Fire Marshal Summary Report

HIGH-RISE RETROFIT ORDINANCES - NO and NO

Report on the Fire Testing of a Roofing System with a Synthetic Underlayment in Accordance with ASTM E a. Trinity ERD Columbia, SC

Understanding and Managing Fire Safety in Housing Accommodation

Product Guide North & South America

JOINT CODE INTERPRETATION

Report of Surface Burning Characteristics Tests on Samples As Submitted By Eco-Sol Ltd

State of California Department of Consumer Affairs Green Science Policy Workshop for Manufacturers and Retailers

Second Revision No. 5-NFPA [ Section No ] Supplemental Information. Submitter Information Verification. Committee Statement

Transcription:

EST. 1860 RetardantsInc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318 952-448-7377 FAX:952-448-2613 Fire Retardant HOT LINE 1-800-913-9385 e-mail: info@fireretardantsinc.com Visit Our Web Site at www.fireretardantsinc.com United States Testing Company, Inc. California Division 5555 TELEGRAPH ROAD LOS ANGELES, CALIFORNIA 90040 213/723-7181 & 722-0608 REPORT OF TESTING NUMBER CLIENT: 6/24/80 SUBJECT:- One (1) sample polyester fabric submitted and identified by Client as: (b) Polyester fabric with BURN BARRIER C.P. applied by C. Talcott Co. REFERENCE Client's confirmation dated June 6, 1980 to Mr. Ted Narahara. TEST REQUEST AND METHODS: 1. Flammability per Federal Test Method Standard No. 191, Method 5903.2 for Flame Resistance of Cloth; Vertical. Conditioning: 70+5 F and 65±5% relative humidity Flame temperature: 1700±20 F (Gas Mixture B) 2.Flammability per NFPA NO. 701, Standard Methods of Fire Tests for Flame Resistant Textiles and Films, Small Test Procedure. The fabrics were tested in their original (as received) condition only. Conditioning: 140±5 F - l-l/2 hrs. prior to test Flame time: 12 seconds 3.Flammability per Boston Fire Dept., Test 11.2, Vertical Flaming Ignition Test for Treated Fabrics and Plastic Coated Fabrics. Conditioning: Ambient Flame applied: 10 seconds Flame temperature: 2200+20 F SIGNED FOR THE COMPANY K. Karr Tech BY C. Macaluso Pg, 1 6 ml Laboratories in: New York Chicago Los Angeles Houston Tulsa Memphis Reading Richland THIS REPORT APPLIES ONLY TO THE STANDARDS ON PROCEDURES IDENTIFIED AND TO THE SAMPLE(S) TESTED. THE TEST RESULTS ARE NOT NECESSARILY INDICATIVE OR REPRESENTATIVE OF THE QUALITIES OF THE LOT FROM WHICH THE SAMPLE WAS TAKEN OR OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS. NOTHING CONTAINED IN THIS REPORT SHALL MEAN THAT UNITED STATES TESTING COMPANY. INC. CON- DUCTS ANY QUALITY CONTROL PROGRAM FOR THE CLIENT TO WHOM THIS TEST RE-PORT IS ISSUED. UNLESS SPECIFICALLY SPECIFIED. OUR REPORTS AND LETTERS ARE FOR THE EXCLUSIVE USE OF THE CLIENT TO WHOM THEY ARE ADDRESSED AND THEY AND THE NAME OF THE UNITED STATES TESTING COMPANY. INC. OR ITS SEALS OR INSIGNIA. ARE NOT TO BE USED UNDER ANY CIRCUMSTANCES.

TEST REQUEST AND METHODS (Cont.) 4. Flammability per City of New York Board of Standards and Appeals; Cal. No. 294-40-SR. Conditioning: 70±5 F and 40±5% relative humidity Flame temperature: 1700±20 F (Gas Mixture B) 5. Flammability per California Administrative Code, Title 19, Public Safety Article 3, Section 1237, Small Scale vertical testing. Sample tested in original (as received condition only. Conditioning: One (1) hour at 140 F 6. Flammability per FAA, FAR Air Worthiness. Standards Part 25, Section 25.853, para. (h) and applicable Appendix F, para. (d), vertical Test. Conditioning: 70±5 F and 50±5% relative humidity

RESULTS: FTMS 191/5903.2 Flame Resistance of Cloth Vertical Afterflame, sec. Afterglow, sec. Char Length, inches Warp: 0 0 2.1 0 0 3.7 0 0 4.7 0 0 5.5 0 0 3.5 Avg. 0 0 3.9 Filling: 0 0 5.1 0 0 4.8 0.3 0 4.7 0 0 5.0 0 0 5.5 Avg. 0.1 0 5.0 NFPA NO 701 Afterflame, sec. Char Length, inches Dropoff, sec. Warp: 0 5.7 0 0 4.7 0 0 5.5 0 0 4.9 0 0 5.4 N* Avg. 0 5.2 0 Filling: 1.1 4.3 0 0 4.9 N* 0 5.5 0 0.4 4.2 0 0 3.6 0 Avg. 0.3 4.5 0 *Legend: N - No drips, residue or flaming dropoff observed.

RESULTS (Cont.) 1. Afterflame shall not exceed two (2) seconds. 2. Any residue falling to the bottom of the test chamber shall not continue to flame. 3. Char length Average, maximum - 5-1/2 inches Individual specimen, maximum - 6-1/2 inches Comments: The submitted sample was observed to drip residue which extinguished while dropping to the chamber floor. The sample meets the requirements of this test. Boston Fire Dept Test 11.2 Afterflame, sec. Afterglow, sec. Dropoff * Avg. *Legend: Yes Flaming dropoff observed. Requirement: Afterflame - 2 seconds maximum for any specimen. Afterglow - 40 seconds maximum for any specimen. No specimen shall produce any faming dropoff during or after ignition.

RESULTS (Cont.) New York Board of Standards and Appeals Flashing Afterflame, sec. Afterglow sec. NF* 0 0 NF 0 0 NF 0 0 Avg. NF 0 0 *Legend: NF - No flashing was observed at any time during administration of test. Flashing No flashing permitted. Afterflame Average 3 seconds maximum. Duration of Glow - Average 20 seconds maximum. Glow confined to charred area may be disregarded. Comments: The submitted sample meets the requirements of this test. California Administrative Code Title 19 After flame, sec Char Length inches Warp: 0 5.8 0 4.2 0 4.8 Avg. 0 5.3 Filling: 1.2 5.2 0 4.1 0 3.5 Avg. 0.4 4.3 After-flame Two (2) seconds maximum. Char Length Average 3.5 inches. Maximum for any specimen 6 inches.