Lighting Proposal Memo. Lighting Proposal. Angela Nudy Lighting/Electrical Dr. Mistrick Lighting Proposal Memo 1

Similar documents
Center for Health Research and Rural Advocacy

Lighting Existing Conditions and Design Criteria Report

[Lighting Proposal Memo ] Hotel and Conference Center Virginia, USA

Hawthorn Building. Penn State Altoona Campus Altoona, PA. Walter Nichols. Lighting/Electrical Option Faculty Advisor: Dr.

Dorrance H. Hamilton Building

University Park, PA. The Pennsylvania State University Architectural Engineering Lighting and Electrical Faculty Advisor: Dr.

Lighting Existing Conditions and Design Criteria Report Brian Regan Ltg./Elect. Virginia Historical Society 10/8/03

University of California Santa Barbara. Student Resource Building

Thesis Proposal. Brian Regan The Virginia Historical Society Building West Wing Addition RICHMOND, VIRGINIA

SMEAL COLLEGE OF BUSINESS BUILDING University Park, PA

Jamie Devenger Senior Thesis Princeton University Sherrerd Hall 1 Lighting Proposal Memo September 11, 2009

Lighting Existing Conditions and Design Criteria Report EXECUTIVE SUMMARY

Lindsey Beane. Executive Summary

HARRY RANSOM HUMANITIES RESEARCH CENTER

Schematic Design Ideas for the Westlake Recreation Center. Presented by: Summer Padgett At Lutron Electronics On December 9, 2003

University of California, San Diego Cal IT 2 Brian Smith. Schematic Design Presentation 06 December 2005

HARRY RANSOM HUMANITIES RESEARCH CENTER

Towson West Village Commons

LIGHTING EXISTING CONDITIONS SUMMARY EXECUTIVE SUMMARY Sara Lappano Ltg./Elec. Corron Cultural Center Middletown, VA

Jennifer Mers. Rio Hondo Library and Learning Resource Center. Executive Summary. General Building. Lighting/Electrical Option

Schematic Design Proposal Presentation

Thesis Proposal Update #2

Holy Cross Hospital North Addition. Fall 2005 Phil Mackey

Lighting Proposal Memo

Lighting Existing Conditions and Design Criteria Report

TECHNICAL ASSIGNMENT #3: SCHEMATIC LIGHTING DESIGN

New LED Product Offerings

Surface Materials. Surface Material Reflectance. Acoustic Ceiling 80% Tile. Painted Gypsum 75% Wall Board. Vinyl Composition 32% Tile

Lord Stirling Community School

Lighting Depth: Courtyard Franklin Care Center, Franklin Lakes, NJ

UNIVERSITY OF PENNSYLVANIA NEURAL AND BEHAVIORAL SCIENCES BUILDING 415 University Ave, Philadelphia, PA 19104

Eric Anderson. Technical Report 1. Existing Lighting Conditions

Advanced Lighting For Office

Franklin Square Hospital Center

A Guide for Applicants and Lighting Designers

Shepherd University Wellness Center AE 481 Revised Thesis Proposal

Technical Report One

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

Technical Assignment I

Code Compliance. Lightcloud. Guides for California Title 24 & ASHRAE

Lighting Existing Conditions and Design Criteria Report

Chandler City Hall Chandler, Arizona

Shepherd University Wellness Center AE 481 Thesis Proposal

The New York University Concourse Project. New York City. Existing Conditions and Design Criteria

Lighting System Conceptual Design

GENERAL ASSIGNMENT CLASSROOM DESIGN STANDARDS

Tech Report 1, Part 1: Lighting Proposal Memo TO: Shawn Good

CLEVELAND HEIGHTS UNIVERSITY HEIGHTS CITY SCHOOL DISTRICT MONTICELLO & ROXBORO MIDDLE SCHOOLS INTERIOR DESIGN

Existing Area Description: The area is an angle around the North point of the building. It is a wide patio wrapping the façade of the building.

Café DUSON- Overview

Lighting Depth CAL IT 2. Brian Smith. Introduction

Duke University Medical School. Duke School of Nursing

2.0 Lighting Depth Introduction

Tech Report. September 9,

Lobby Lighting Redesign

THE AUGUST WILSON CENTER FOR AFRICAN AMERICAN CULTURE PITTSBURGH, PENNSYLVANIA. PERKINS + WILL chematic Design Presentation MICHAEL P.

Main Lobby Area (North Vestibule thru South Vestibule):

Lighting Depth Part 1: Exterior Space

3.2.4 OFFICE FACILITIES

student National Lighting Design Competition Winners 2010

Nu Skin Innovation Center. Location: Provo, Utah Lot Size: 435,600 GSF Building Size: 168,000 GSF Project Type: Commercial LEED Gold Certified

Lobby Lighting Design

Lighting Control Strategies. to meet code requirements save energy and improve building performance

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

The Bahen Centre for Information Technology. Meeting Room Lighting Redesign. Introduction. University of Toronto ~ Toronto, Ontario, Canada

2 Main Office Building BLDG-955A Building Purpose Building Area Administration offices. Training room 7,610 SF Inspection Date August 16, 2016 Inspect

SF LINEAR FLOURESCENT T5 WITH HALOGEN MR 16 SAJ HALOGEN DOWNLIGHT FULLY ADJUSTABLE. Sept [Type text] Page 1

Gathering Space. Function and Orientation. Space Characteristics Gregory Wolfe 2004 Senior Thesis Lighting / Electrical

RIVERSIDE DESIGN CD-1 GUIDELINES. Adopted by City Council August 9, 1983

LIGHTING NORTH FAÇADE AND PLAZA

Executive Summary. CNBC Global Headquarters Christine Cajilig

California s 2008 Building Energy Efficiency Standards for Residential and Nonresidential Buildings

Senior Thesis Presentation

GARCIA GALUSKA DESOUSA Consulting Engineers

Momo Sushi. Robert Blecker ABS 643

Advanced Lighting Control for High Building Performance

1.0 Introduction to Lighting Depth. 1.1 Hotel Tower Facace and Porte Cochere

Overview. The Reading Room

Project Proposal The Sterling and Francine Clark Art Museum 225 South Street, Williamstown, MA

Lighting Depth Study. Exterior Departure/Canopy Area

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

Duke Tower Main Entrance Lobby Overview

B. It is recognized that these standards are updated irregularly and lighting technology is changing rapidly.

LIGHTING CONTROLS

Division VI Community Mixed Use (CMU) Architectural Guidelines and Standards

Lighting Design Thought Process

INDEPENDENCE VISITOR CENTER PHILADELPHIA, PA

Thesis Proposal Sherrerd Hall, Princeton University, NJ

DAYLIGHT AS A VISUAL EXPERIENCE

University of Pennsylvania, Neural and Behavioral Sciences Building

H107 Video Conference Room

Technical Report 1 Part 2

Lighting Design Criteria: Codes and Standards

Seating Arrangements

Multipurpose Room. Existing Conditions General Overview. Mark W. Miller Sibley memorial Hospital Grand Oaks Washington, DC

ASHRAE October 18, 2013

WSA120: New Energy Codes and Lighting Controls

Oregon Non-Residential Building Energy Code

Technical Assignment 1 Existing Lighting Conditions and Design Criteria

RHBL 7325 ENVIRONMENTAL ANALYSIS. By: Whitney Musick

Transcription:

Lighting Proposal Angela Nudy Lighting/Electrical Dr. Mistrick 12.16.2006 Lighting Proposal Memo 1

Executive Summary I have chosen to redesign the lighting for four interior spaces and one exterior space in the Center for Health Research and Rural Advocacy (CHRRA). The first space is the first floor open office. The space consists of cubicles and filing storage and is enclosed by an insulated glass curtain wall on the southwest façade. Reading, writing, filing and circulation will take place in this area of the building. There is a great opportunity in the open office for daylight harvesting and photosensor dimming. The second proposed redesign area is the 300 seat ellipsoidal auditorium. The auditorium is on the ground floor of CHRRA and is one of the main spaces for visitors to enter when coming to the building. Its main uses are: lectures, presentations, and group discussions. Having a flexible system implemented in this area is critical to its multiple functions. The third interior space is the double height main entrance lobby. This is the first area that a patron entering the building will see. The north facing façade is a curved glass curtain wall, which lets a great deal of natural light enter the space. The main lobby does not have any tables or chairs; therefore, it is used as mainly a circulation, meeting area. Facial modeling is important in this space. The final interior space is the multipurpose room. The space is located on the ground floor and is intended to be used as both a presentation space and also a banquet space. The room has two moveable partitions that can create three smaller multipurpose rooms. The room will be used for presentations, group discussions, lectures, and dining. For the exterior redesign, I have decided to focus on the entrance to the building, the pedestrian pathway to the main entrance, and the terrace on the south side of the building. The exterior of CHRRA is mainly glass so it is difficult to light the façade of the building from the exterior without creating glare. Therefore lighting the façade will come from within. Lighting Proposal Memo 2

1. First Floor Open Office Work Space The first floor open office is located on the west side of the building along the south facing glass curtain wall. The remainder of the open area is surrounded by private offices and conference rooms. The office consists of partial height cubicle workstations with PC s for each employee. There is also an area of circulation space directly adjacent to the glass curtain wall that is separated from the workstations by partitions and filing cabinets. This circulation area acts as a buffer for direct sunlight entering the space in order to help minimize the impact the direct sunlight has on the workstations. The space is constructed of dark carpeting, off white paint, and some fabric accent wall-coverings. The current lighting system is an array of recessed linear fluorescent fixtures that are 4 wide by 8 long. Each 4 section of the luminaire houses one T8 32W fluorescent lamp. Over the circulation area are compact fluorescent downlights. The lighting system is controlled by three photocells which are placed at different step backs from the curtain wall. There was also a proposal for automated shades to be installed along the south facing wall in order to maximize energy efficiency and minimize the heat and direct sun effects. Tasks performed in the space: Extensive VDT use Reading Writing Filing Circulation Conversation with other employees Impromptu meetings Lighting Proposal Memo 3

First Floor Open Office Lighting Plan Lighting Proposal Memo 4

First Floor Open Office Section- North/South First Floor Open Office Section- East/West Lighting Proposal Memo 5

2. Auditorium The entrance to the auditorium is located on the ground floor of the Center for Health Research and Rural Advocacy (CHRRA); occupants enter at the top of the space and then walk down the stadium seating to the projector screen and speaker area. The space spans vertically between the lower level and the ground floor. The auditorium is ellipsoidal in plan view with an architectural cove built around the entire perimeter of the space. The space is equipped with over 400 auditorium seats with pull up desks, a front projection system, and a stage area for speakers to stand. There is a control room in the back of the auditorium where the projector hardware is located. The space is constructed of acoustic ceiling tile, dark carpeting with rubber treads for the stairs, off white wall paint with acoustical fabric wall coverings. The current lighting system consists of different zones of light. Over the audience seating, there is an array of recessed linear fluorescent 4 wide by 8 long luminaires which are dimmable and on one control leg. Over the speaker area, there are two rows of compact fluorescent downlights where are also dimmable and on their own control leg. Lastly, there is the accent cove lighting made up of biax lamps which are slightly elevated in order to create a curved cove luminaire. These fixtures are also dimmable and controlled separately from the rest of the space. Tasks performed in the space: Presentations Reading/Writing in the audience seating Reading from the speaker podium Reading off the projector screen Facial Identification Group Discussions Visual Demonstrations VDT usage Lighting Proposal Memo 6

Auditorium Lighting Plan Lighting Proposal Memo 7

Auditorium Section- North/South Auditorium Section- East/West Lighting Proposal Memo 8

3. Main Entrance Lobby The double height lobby is located on the North side of the building where the glass façade begins to curve and the ceiling height beings to slope downward. On both the North and South sides, the lobby is surrounded by curved glass curtain wall. The double height portion of the lobby is surrounded by break out space on the ground level and first floor. This area includes tables and chairs for casual reading, writing, eating, or personal breaks. The lobby includes an open staircase from the ground level to the first floor. The lobby is constructed of different colors of ceramic tiling, and wood accent wall coverings along with off white wall paint. The existing lighting system is made up of a combination of lamp sources. In the double height space, there are recessed induction downlights. In the break out areas, compact fluorescent semi recessed downlights with a frosted glass cone were used. Neither system of lighting is dimmable. Tasks performed in the space: Reading Writing Eating Conversations Circulation Facial Recognition Lighting Proposal Memo 9

Main Entrance Lobby Lighting Plan Main Entrance Lobby Section- East/West Lighting Proposal Memo 10

4. Multipurpose Room The multipurpose room is located in the interior of the east side of the building on the first floor. The space is completely enclosed without any daylight component. The multipurpose room is one large area with two moveable partitions giving it the versatility to be broken up in to three smaller spaces. There are architectural coves built into the walls of the three small spaces on the northwest and southeast walls. The perpendicular walls do not have cove lighting. The space has a variety of furniture set ups including banquet tables and chairs, and long desk worktables with conference room chairs. The area is constructed of brown carpeting, off white walls, and acoustical ceiling tile. The existing lighting system is made up of the same linear fluorescent recessed luminaires used in the open office and auditorium. These fixtures are all dimmable and can be controlled as one large zone or as three separate zones depending on the moveable partitions. The accent wall lighting is linear fluorescent wall washer cove luminaires. These are also dimmable and controlled separately from the task lighting system. Tasks performed in the space: Reading Writing Facial Recognition VDT use Dining Receptions Conferences Tutorials Meetings Lighting Proposal Memo 11

Multipurpose Room Lighting Plan Lighting Proposal Memo 12

Multipurpose Room Section- East/West Multipurpose Room Section- North/South Lighting Proposal Memo 13

5. Exterior Façade and Site Lighting The exterior façade of CHRRA is primarily a curved glass curtain wall including the use of bother spandrel and tempered insulated glazing. Around the entrance to the lobby and the lower level of the building is CMU block. Aluminum metal paneling is incorporated into the glass curtain wall façade design. Because of the large amount of glass, the façade is not lit from the exterior but at the entrances to the building. Around the site, there are pole mounted fixtures varying in height from 10 to 18 which are all dark sky compliant. The fixtures on the site are metal halide while the roadway lighting is high pressure sodium to match the existing fixtures used on the campus. Efforts were made to use minimal light only where necessary in order to minimize spill light on the site for the dark sky LEED credit. There is also an extensive roof top garden outside of the first floor open office. There is no lighting in this area. I have decided to focus my redesign on the pedestrian pathway to the main entrance, the canopy over the main entrance, and the terrace on the south side of the building. Tasks performed in the space: Facial Recognition Car Recognition Circulation Reading Pedestrian/Automobile interaction Driving Important to incorporate safety from lighting in this area. Photographs of the CHRRA Model Exterior Lighting Proposal Memo 14

CHRRA Site Lighting Plan Lighting Proposal Memo 15

CHRRA Exterior Elevation- South/West CHRRA Exterior Elevation- East/North Lighting Proposal Memo 16