Aircraft Hangars DESCRIPTION. A single fire area not larger than 40,000 sq. ft. (3,716 sq. m) per hangar construction type as defined by NFPA 409

Similar documents
Aircraft Hangers. ft. (3,716 sq. m) per hangar construction type as defined by NFPA 409


WILLIAM HICKS. MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI. Associate Professor Eastern Kentucky University

HIGH-EXPANSION FOAM GENERATORS

Technical Article. Foam Systems - Low Expansion, Medium Expansion, High Expansion. Martin Workman, Product Manager Special Hazards Division

Distribution Restriction Statement

AIRCRAFT HANGARS, AIRCRAFT MANUFACTURING AND ASSEMBLY FACILITIES, AND PROTECTION OF AIRCRAFT INTERIORS DURING ASSEMBLY.

PLAN REVIEW CHECKLIST

Technical Article. High Expansion Foam Systems. Martin Workman Viking Product Manager. September,

Foam Products ENGLISH

SECURITY BLANKET Foam Fire Protection Products

TECHNICAL DATA OBSOLETE

A.U.P.C.I ASOCIACIÓN URUGUAYA DE PROTECCION CONTRA INCENDIO AUPCI

The Next Generation of Foam Fire Suppression. Automatic CAF Fire hose reel system FEATURES

Module 3. Water-Based Suppression Systems (WBSS) Part II: Highlights of Code Requirements

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

Second Revision No. 11-NFPA [ Section No. 2.4 ] Submitter Information Verification. Committee Statement

Foam Systems U.S. Quick Reference Guide

The development Of the new CEN standard For fire fighting foam systems EN13565 Part 2

MODULE 2. Water-Based Suppression System Basics

Public Input No. 79-NFPA [ Section No. 1.1 ] Additional Proposed Changes. Statement of Problem and Substantiation for Public Input

MSC Guidelines for Foam Fire Suppression Systems

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

M E M O R A N D U M. According to the final ballot results, all ballot items received the necessary affirmative votes to pass ballot.

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

MAINTENANCE AND SERVICE OF AUTOMATIC FIRE EXTINGUISHING SYSTEMS

An Overview Of Fluorinated Firefighting Foams: Past, Present & Future Presented by: Jerry Back, JENSEN HUGHES FOAM SYSTEM SYMPOSIUM

FIXED PROTECTION FOR OIL AND CHEMICAL PLANTS

Enhanced MRO Hangar Fire Protection

A HISTORICAL REVIEW OF FLUORINATED FOAM FIREFIGHTING AGENTS, PERFORMANCE REQUIREMENTS/ ENVIRONMENTAL SAFEGUARDS REVIEW

Staff Liaison: Mark T. Conroy Committee Scope: This Committee shall have primary responsibility for documents on fire safety for the construction and

ommercial and military aircraft MRO operations play a huge role in keeping modern aircraft in service by taking on new tasks and

How it may affect the future of your school. Michael France Director, Regulatory Affairs National Air Transportation Association

The metering orifice is sized according to the type and percentage of concentrate used and is also secured with a stainless steel retaining ring)

Storage Sprinkler. Model LP-46 (SIN) V4603, K25, Standard Response Storage Upright Sprinkler, Patent Pending

Special Occupancy Requirements

Design & Construction Standards, Revised January

Sprinkler System Installer Level 2

Significant Advancements in Water Based Fire Suppression for Storage Occupancies

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Portable Fire Extinguishers

FIRE SPRINKLER SYSTEMS POLICY

TECHNICAL DATA OBSOLETE

CHAPTER A-6 FIRE PROTECTION

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

GUIDELINES FOR THE APPROVAL OF HELICOPTER FACILITY FOAM FIRE-FIGHTING APPLIANCES

When it Really Matters

WATER POWERED OSCILLATING MONITOR

FIRE SPRINKLER SYSTEMS POLICY

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;

Fire Protection in High-rise Buildings

CITY OF MADISON FIRE DEPARTMENT (MFD) FIRE PROTECTION SYSTEM PLANS

Contren Learning Series Apprenticeship Training Program for Fire Sprinkler Fitters

AUTOMATIC FIRE SPRINKLER SYSTEM STANDARDS Development Standard #4.1 (Commercial Installations)

Sprinkler System Installer Consultation Discussion Guide

Building Description Applicable Codes & Standards Prescriptive Requirements. Performance Based Design

Irrigation Tech II HYDRAULIC TROUBLESHOOTING

FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES

TECHNICAL DATA 3% AR-AFFF

AMENDMENTS NO. 3/2012 to

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

TN-25 Tunnel Fire Protection System. Safer. Smarter. Tyco.

WHITE PLAINS SMOKE CONTROL CODE PART 1. GENERAL REQUIREMENTS

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011

& Fire Extinguisher Training

FIRE SPRINKLER SHOP DRAWING SUBMITTAL REQUIREMENTS

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA

Skill Sheet 17-I-1. Suppress an interior structure fire Direct, indirect, or combination attack. (NFPA 1001, , )

culus Listed: Category VNIV Refer to the Approval Chart on page 3. VK697 Attic Upright Sprinkler Specifications:

GEPRO PROTECTIA LA INCENDIU

Large Family Daycare Guideline

AUTOMATIC FIRE SPRINKLER SYSTEMS

Public Comment No. 2-NFPA [ Section No ]

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

Twin-Agent Fire Fighting/Securing Systems Specifications

contents iii Drilling Tools 27 Adjustable Choke 27 Automatic Drillers 29 MWD and LWD Tools 30 How They Work 30 Uses 30

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

Fire Suppression Introduction Contact Information

TECHNICAL DATA OBSOLETE

Safe Schools: A Health and Safety Check


DEPARTMENT OF DEFENSE HANDBOOK COVERED STORAGE 1. THE FOLLOWING PAGES OF MIL-HDBK-1032/2 HAVE BEEN REVISED AND SUPERSEDE THE PAGES LISTED:

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

freedom residential horizontal sidewall lead free sprinkler VK4840 (k4.2)

Tire Storage. Michigan Fire Inspectors Society Fall Conference

FIRE PROTECTION SYSTEMS

Hot Work Permit. Can this job be avoided? Is there a safer alternative? Permit No.:

OCFA Planning and Development Section Fees Effective September 28, 2015

Fire Suppression Performance of Manually Applied CAF and Other Water Based System

Revision May All designs must be submitted to FM Global for review and approval prior to issuing such for bids.

1.2 To ensure the safety of all persons working in or occupying a building where a hot work operation is performed.

Committee Input No. 28-NFPA 13R-2013 [ Global Input ]

NFPA 418. Standard for. Heliports Edition. Copyright 2006, National Fire Protection Association, All Rights Reserved

FIRE PROTECTION SYSTEMS IN BURJ KHALIFA. By NAFFCO Fire Protection

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

Transcription:

Aircraft Hangars DESCRIPTION Considering the value of commercial and military aircraft, it has become extremely important to have a reliable fixed fire protection system in aircraft storage, servicing, maintenance and paint facilities. This fire protection system is designed to give reasonable control and extinguishment of any Class A or B type fire in the facility. Most fire protection systems for aircraft handling facilities are designed in accordance with NFPA 409 (2001) Aircraft Hangars, or the Airforce ETL 02-15 (Engineering Technical Letter) Fire Protection Engineering Criteria for Aircraft Maintenance, Servicing and Storage Facilities. Per NFPA 409 there are four basic aircraft hangar designs that have been classified: GROUP I AIRCRAFT HANGAR A hangar having at least one of the following features and operating conditions: An aircraft access door height over 28 ft. (8.5 m) A single fire area in excess of 40,000 sq. ft. (3,716 sq. m) Provision for housing an aircraft with a tail height over 28 ft. (8.5 m) Provision for housing strategically important military aircraft as determined by the Department of Defense GROUP II AIRCRAFT HANGAR A hangar having both of the following features: An aircraft access door height of 28 ft. (8.5 m) or less A single fire area not larger than 40,000 sq. ft. (3,716 sq. m) per hangar construction type as defined by NFPA 409 Single Fire Area Type of Equal or Greater Than But Not Larger Than Construction Sq. Ft. (M 2 ) Sq. Ft. (M 2 ) Type I (443) and (332) 30001 (2787) 40000 (3716) Type II (222) 20001 (1858) 40000 (3716) Type II (111), Type III (211), and Type IV (2HH) 15001 (1394) 40000 (3716) Type II (000) 12001 (1115) 40000 (3716) Type III (200) 12001 (1115) 40000 (3716) Type V (111) 8001 (743) 40000 (3716) Type V (000) 5001 (465) 40000 (3716) GROUP III AIRCRAFT HANGAR A Group III hangar may be a freestanding unit for single aircraft, a row hangar housing multiple aircraft that has a common structural wall, roof system and openings for each aircraft or an open bay hangar capable of housing multiple aircraft with the following features: An aircraft access door height of 28 ft. (8.5 m) or less A single fire area that measures up to the maximum square footage permitted for specific types of construction per NFPA 409 Maximum Type of Single Fire Area Construction Sq. Ft. (M 2 ) Type I (443) and (332) 30000 (2787) Type II (222) 20000 (1858) Type II (111), Type III (211) and Type IV (2HH) 15000 (1394) Type II (000) 12000 (1115) Type III (200) 12000 (1115) Type V (111) 8000 (743) Type V (000) 5000 (465) Building construction types are defined in NFPA 220, Standard on Types of Building Construction. CHEMGUARD INC. 204 S. 6 th Avenue Mansfield, Texas, USA 76063 (817) 473-9964 FAX (817) 473-0606 Rev: 09/2003 Page X - 1

GROUP IV AIRCRAFT HANGAR A Group IV hangar may be a member-covered, ridge, steel frame structures limited to single story height, a single fire area, used for storage and service of aircraft. FIRE PROTECTION OPTIONS Once the aircraft hangar classification has been determined, a suitable fire protection system/ requirement can be established. There are four types of foam fire protection systems suitable for the protection of an aircraft hangar. These systems may be used separately or they may be combined. Overhead foam water sprinkler system Foam monitor system Foam hand hose line system High Expansion foam system The overhead foam water sprinkler system can be: Closed head pre-action Standard wet pipe Deluge system If used with either Protein or Fluoroprotein type foam concentrate, the foam water sprinkler heads must be air-aspirating. When used with AFFF, the sprinkler heads can be standard non air-aspirating. When using Protein or Fluoroprotein foam use an application rate of 0.20 of gpm per sq. ft floor area, AFFF systems shall use an application rate of 0.16 gpm per sq. ft of floor area. Monitor Systems: May be of the oscillating or fixed nozzle type. Oscillating Monitor Systems consist of monitors that automatically oscillate from side to side when discharging foam onto the hangar floor. They are normally preset to oscillate over a given arc to provide a flow rate over a specific area. Fixed Monitor Systems have nozzles that are typically mounted on a manifold or as single units approximately 3 feet above the hangar floor. They are preset for angle of elevation and discharge pattern to achieve the best possible stream pattern and range while keeping the stream low enough to flow under the wing of any aircraft. This type of monitor system is often used where aircraft or maintenance equipment in the hangar could interfere in the normal operation of the oscillating type monitor. Foam Hand Lines: These systems are required as supplementary protection in Group I and II aircraft hangars. High Expansion Systems: These systems are designed to discharge an expanded mass of foam bubbles over the protected area to a depth of at least 3 ft. within 1 minute and flow for a minimum of 12 minutes. GROUP I HANGAR FIRE PROTECTION DESIGN REQUIREMENTS Protection of Group 1 aircraft hangars, other than those housing unfueled aircraft, shall be one of the following options: A. A foam water overhead deluge system. If the hanger houses single aircraft having wing areas greater than 3000 Sq. Ft. A supplementary protection system consisting of either a low level oscillating monitor system or a low level high expansion foam system shall be provided covering the floor area beneath the aircraft being protected. Both AFFF systems designed for 10 min. operation. The system shall achieve control of the fire within the protected area within 30 seconds of system actuation and extinguishment of the fire within 60 seconds. B. A combination of a closed head water sprinkler system* AND an automatic low level low expansion foam system designed per the requirements of NFPA 409. C. A combination of a closed head water sprinkler system* AND an automatic low level high expansion foam system designed per the requirements of NFPA 409 (see high expansion foam system worksheet for details). CHEMGUARD INC. 206 S. 6 th Avenue Mansfield, Texas, USA 76063 (817) 473-9964 FAX (817) 473-0606 Rev: 04012001 Page X - 2

*Note: The water sprinkler system for Group 1 hangars is to be designed for 0.17. Gpm per sq. ft over any 15,000 sq..ft area. If the foam-water sprinkler system is also used for column fire protection within the hangar in lieu of the column having a fire resistive rating of not less than 2 hours, allowances must be made for the required additional foam concentrate. A reserve supply of foam concentrate must be directly connected into the system and be readily available if required. Foam-water hand hose systems shall be installed if the aircraft DO NOT have drained and purged fuel tanks. High Expansion Foam System The generators should only be mounted at the ceiling or on exterior walls of the hangar where outside air only is used to generate the foam. It is recommended that the high expansion generators be installed so that the flow of foam on the floor is directed to areas immediately adjacent to, but not directly onto the aircraft. GROUP II HANGAR FIRE PROTECTION REQUIREMENTS The fire protection requirements of a Group II hangar may be one of the following. A. In accordance with the requirements for a Group I hangar B. A combination of a closed head water sprinkler system* AND an automatic low level low expansion foam system designed per the requirements of NFPA 409. C. A combination of a closed head water sprinkler system* AND an automatic low level high expansion foam system designed per the requirements of NFPA 409 (see high expansion foam system worksheet for details). D. A closed head foam water sprinkler system based on the same design requirements as option as A above. GROUP III HANGAR FIRE PROTECTION REQUIREMENTS A. Fixed fire protection systems are not normally required. B. If any hazardous operations such as fuel transfer, welding, painting, torch cutting, etc. is performed in a Type III hangar, the hangar should be protected as per a Type II aircraft hangar. GROUP IV HANGAR FIRE PROTECTION REQUIREMENTS Where the hangar fire area housing unfueled aircraft is greater than 12,000 sq. ft. A. A low expansion foam system providing 0.10 gpm/sq. ft. over the entire storage and service areas. B. A high expansion foam system providing 3 cu. ft./min. per sq. ft. over the entire storage and service areas. C. An automatic water sprinkler meeting the following: Closed head sprinkler meeting NFPA 13 Quick response water sprinkler heads A design application rate of 0.17 gpm/sq. ft. over any 5000 sq. ft. Additional Requirement for all Type aircraft hangars. Fire extinguishers must be distributed throughout the aircraft hangar per NFPA 10 Standard for Portable Fire Extinguishers. Foam System Application Information Overhead primary protection systems. Discharge duration - 10 minutes Application rate - 0.16 gpm per sq. ft. / AFFF through standard sprinkler heads 0.20 gpm per sq. ft. / Protein, Fluoroprotein or AFFF through air aspirating sprinkler heads A reserve supply of foam concentrate CHEMGUARD INC. 206 S. 6 th Avenue Mansfield, Texas, USA 76063 (817) 473-9964 FAX (817) 473-0606 Rev: 04012001 Page X - 3

should be directly connected to the system and be readily available. If the foam concentrate is injected into the water supply by a foam pump, there are to be two pumps (one main, one reserve), either of which can provide the necessary supply of foam concentrate at the design rate. When using a 1% foam concentrate, multiply the total foam solution required by.01 to obtain the quantity of foam concentrate required. Multiply by.03 when using a 3% concentrate and by.06 when using 6%. If more than one aircraft is located within any drainage system, it is recommended that the supplementary foam monitor system be capable of effectively covering the complete floor beneath all aircraft. Minimum flow rates through supplementary monitor systems for the area of coverage is to be 0.10 gpm per sq. ft. when using AFFF and 0.16 gpm per sq. ft. when using Protein or Fluoroprotein foam concentrates. It is recommended that a control valve be installed at the base of each oscillating monitor or fixed nozzle system. SUPPLEMENTARY PROTECTION SYSTEMS Monitors Each supplementary fixed foam fire protection system is to be designed to achieve control of the specified floor area within 30 seconds of activation and to extinguish any fire within 60 seconds. The specified floor area is the area under the wing and the wing center section of the aircraft. The different configurations of aircraft and their positioning within the hangar must be considered for effective fire protection when positioning the monitors. Foam Hand Line Protection System Provisions are to be made in water flow calculations for operating a minimum of two foam hand line systems. Each system must flow a minimum of 60 gpm at sufficient nozzle pressure with a foam solution discharge duration of 20 minutes. CHEMGUARD INC. 206 S. 6 th Avenue Mansfield, Texas, USA 76063 (817) 473-9964 FAX (817) 473-0606 Rev: 04012001 Page X - 4

CHEMGUARD INC. 206 S. 6 th Avenue Mansfield, Texas, USA 76063 (817) 473-9964 FAX (817) 473-0606 Rev: 04012001 Page X - 5

CHEMGUARD INC. 206 S. 6 th Avenue Mansfield, Texas, USA 76063 (817) 473-9964 FAX (817) 473-0606 Rev: 04012001 Page X - 6

CHEMGUARD INC. 204 S. 6 th Avenue Mansfield, Texas, USA 76063 (817) 473-9964 FAX (817) 473-0606 Rev: 09/2003 Page XI - 7

CHEMGUARD INC. 204 S. 6 th Avenue Mansfield, Texas, USA 76063 (817) 473-9964 FAX (817) 473-0606 Rev: 09/2003 Page XI - 8