USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

Similar documents
IN-LINE CENTRIFUGAL FAN VENTS VKP PS 125. User`s manual.

READ AND SAVE THESE INSTRUCTIONS

USER S MANUAL. Heat Recovery Ventilator. Vents Brig HRV 200 Vents Brig HRV 300

(3 plastic wire connectors,blade balancing kit, 2 extra mounting screws #10-32 for outlet box.)

READ AND SAVE THESE INSTRUCTIONS

Bentley II 13 in Ceiling Fan Owner s Manual. Bentley II Ventilador de Techo de 33 cm Manual del Propietario

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

breeze easytm model # F100-1W

Roanoke 48 in Ceiling Fan Owner s Manual. Roanoke Ventilador de Techo de 1,22 m Manual del Propietario

Installation & Maintenance Instructions

User s Manual and Operating Instructions

Torrena 42 Ceiling Fan

Hawkins 44 in Ceiling Fan Owner s Manual. Hawkins Ventilador de Techo de 1,12 m Manual del Propietario

Camarillo 52 Ceiling Fan

e Bath Fan with Light User s Guide

e Bath Fan with Light User s Guide

LIMITED LIFETIME WARRANTY

e Heater/Exhaust Fan/Light User s Guide

LIMITED LIFETIME WARRANTY

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

User s Manual and Operating Instructions

LIMITED LIFETIME WARRANTY

15-Year Limited Warranty

Lifetime Limited Warranty

HI Industrial Utility Heater HI Soleus Air International

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

LIMITED LIFETIME WARRANTY

e Bath Fan with Light User s Guide

L I F E T I M E W A R R A N T Y L I F E T I M E W A R R A N T Y 52 VERANDA

Glendale 52 in Ceiling Fan Owner's Manual. Glendale Ventilador de Techo de 1.32 m Manual del Propietario

22In. Oscillating Pedestal Fan. Owner s Manual

IMPORTANT SAFETY INFORMATION

Lifetime Limited Warranty

52 SAN LUCAS CEILING FAN

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

Florentine IV 56 in Ceiling Fan Owner s Manual Florentine IV Ventilador de Techo de 1,42 m Manual del Propietario

BX600. CLASSIC ColleCtion. Specifications. Model Colour Venting Size. Air Flow Volume: Electrical Consumption:

Instruction Manual. MODEL: FD1603 POWER SUPPLY: VAC, 60Hz or VAC, 50Hz POWER CONSUMPTION: 250W

SPACESAVER INSTRUCTION MANUAL WARRANTY CERTIFICATE

52 BARSTOW CEILING FAN

1 HP Air Mover. Owner s Manual

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

Bathroom Exhaust Fan/Fluorescent Light Combination

52 STRATHMERE CEILING FAN

Panel Fan Series Operators Manual (Galvanized and Polymer)

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

R Series B & T2 Model

LIMITED LIFETIME WARRANTY

52 CEILING FAN. Owner s Manual Models #50336, 50337

High-Velocity Floor Fan

60In. Ceiling Fan. Owner s Manual

FLCH4R Garage and Utility Electric Heater

Operating Instructions & Parts Manual Models 99533, 99532

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

30-YEAR LIMITED WARRANTY

SUNCOURT RADON FAN MODEL: RDN04 & RDN04-3, RDK04 & RDK04-3 INSTALLATION INSTRUCTIONS

ALUMA INSTRUCTION MANUAL WARRANTY CERTIFICATE

ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

Bathroom Exhaust Fan/Fluorescent Light Combination

INSTALLATION USE & CARE MANUAL ALL WEATHER SL-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER

READ AND SAVE THESE INSTRUCTIONS

MAYFIELD CEILING FAN LISTED E ITEM # MODEL #BTH44ABZC5C BTH44BNK5C Español p. 20 ATTACH YOUR RECEIPT HERE.

52 BAYTOWNE CEILING FAN

Lifetime Limited Warranty

48 TAYLOR CEILING FAN

24 & 30 Quiet Design Oscillating Wall Mount Fan

52 BERKSHIRE CEILING FAN

Panel Fan Series Operators Manual (Galvanized and Polymer)

ELECTRIC FIREPLACE HEATER WITH SINGLE GLASS DOOR

Instruction Leaflet. Read instructions before operating. Retain for future reference.

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

Lifetime Limited Warranty

Integra Family. Operations Manual. Models: Integra TX SS, Integra HD, Integra DS, Integra DS LA, Integra UHS, Machine Name: Serial Number:

Universal Fan and Light Remote Control

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

ARMITAGE CEILING FAN ITEM # MODEL #CC52WW5L. Español p. 17 ATTACH YOUR RECEIPT HERE. Purchase Date

SSF1610B-CN TRUSTED FOR OVER 100 YEARS. 16 inch (40cm) Oscillating. Stand Fan. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

PANEL FAN SERIES OPERATORS MANUAL (Galvanized and Polymer)

Eliza 56 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

TILGHMAN CEILING FAN. LISTED For Damp Location E ITEM # MODEL #WCK52LMW5N WCK52NWZ5N. Español p. 20 ATTACH YOUR RECEIPT HERE

OPERATING MANUAL Gfp 255C Please read this manual carefully before operating!

harborbreezeoutlet.com

Lifetime Limited Warranty

XT Series Thermostats

Stand Fan. English. Owner s Guide. Model F R

ULTRA SILENT VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE OPERATION CAUTION!

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

Larson by Hampton Bay

Insulated Ventilators. Operating Instructions & Parts Manual

OWNER S MANUAL FINLEY FIREPLACE. Product code: UPC code: Date of purchase: / /

INSTALLATION AND OPERATION GUIDE

USER MANUAL. Frigate HRV 120 SR Frigate ERV 120 SR. Heat (energy) recovery ventilation unit

OmniDry 2.9 Amp Centrifugal Air Mover

B.I.C.A Built-In Coffee Appliance

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

Irene READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Air Storm Fans. Air Storm 18 Fiberglass Fan Installation and Operation Manual

Laing Thermotech. Autocirc The Instant Hot Water Pump Models E1-BCANCT1W-06 and E1-BCANRT1W. Installation & Operating Manual

Lynwood 52 in Ceiling Fan Owner s Manual. Lynwood Ventilador de Techo de 1,32 m Manual del Propietario

Transcription:

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES Bucket Fan 420 Bucket Fan 1055 Bucket Fan 1460 420 1055 1460

2 Bucket Fan CONTENT INTRODUCTION 3 USE 3 WHAT S INCLUDED IN THE BOX 3 DESIGNATION KEY EXAMPLE 3 SIZE RANGES 3 SAFETY REQUIREMENTS 4 MOUNTING AND INSTALLATION GUIDELINES 5 BUCKET FAN PARTS 7 MAINTENANCE 8 WIRING THE FAN 8 TROUBLESHOOTING 11 STORAGE 11 WARRANTY 12

Bucket Fan 3 INTRODUCTION This manual will provide you with installation, operation, and service instructions, as well as technical data of the Bucket Fan series and series. USE Bucket Fans are used for equalizing the floor-to-ceiling temperature. This provides a more comfortable thermal environment for occupants, while at the same time reducing energy costs. In the cold months the overheated air at the roof is gently directed to the floor where it is needed and wanted. During the warm months for buildings that are air conditioned, Bucket Fans help push the cold air coming from the registers at the ceiling to occupant level. One Bucket Fan or One Users Manual One set of Hanging/Safety Gripples Controller (if ordered) WHAT S INCLUDED IN THE BOX DESIGNATION KEY EXAMPLE Bucket Fan 420 air destratification fan producing 420 CFM 420 air destratification fan with isolated casing producing 420 CFM SIZE RANGES Model Dimensions [inches] Weight A H H1 D D1 [lbs] Bucket Fan 420 15 3/16 20 3/16 15 3/16 13 7/16 10 3/16 12 Bucket Fan 1055 17 1/4 23 7/8 17 15/16 15 7/16 12 3/16 15.2 Bucket Fan 1460 19 3/16 27 5/16 20 5/16 17 3/8 14 3/16 20.3 420 17 15/16 24 5/8 18 7/16 15 1/8 11 7/8 24.3 1055 19 15/16 27 5/8 20 3/8 17 1/16 13 7/8 32 1460 21 7/8 30 9/16 22 3/8 19 1/16 15 13/16 37.5 Model Bucket Fan 420 420 Bucket Fan 1055 1055 Bucket Fan 1460 1460 Volts [V / 60 Hz] 120 120 120 Max. watts 60 94 162 Max. Amps 0.51 0.8 1.38 Air flow [CFM] 420 1055 1460 RPM 1700 1675 1685 Max.operating temp.[ 0 F] 140 140 140

4 Bucket Fan BUCKET FAN WHISPER BUCKET FAN Fig. 1 SAFETY REQUIREMENTS READ AND SAVE THESE INSTRUCTIONS. WARNING: RISK OF ELECTRIC SHOCK, DISCONNECT POWER BEFORE SERVICING ; WANRING: TO REDUCT THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE CAUTION: THIS UNIT HAS AN UNGUARDED IMPELLER. DO NOT USE IN LOCATIONS READILY ACCESSIBLE TO P EOPLE OR ANIMALS During installation and operation, observe all codes and safety standards for your locale. Always make sure the electricity is disconnected at the main power source prior to connection, adjustment, servicing and/or repair operations. Electrical connections should only be done by a qualified electrician. Before connecting and powering up the Bucket Fan make sure that the unit is free of visible damage and there are no foreign objects inside the unit that can damage the motor and/or impeller blades. Misuse of the Bucket Fan and/or any unauthorized design alterations or modifications voids the warranty. VENTS US assumes no liability for misuse or and/or any unauthorized design alterations or modifications. Under no circumstances should the Bucket Fan be operated in an environment with temperatures exceeding the specifications indicated on the motor name plate. The fan should never be operated in area where there are hazardous and/or explosive vapors. Make sure power is off before attempting installation. Whenever a Bucket fan is first installed, serviced, moved, or repaired the unit must be disconnected from the main power source.

Bucket Fan 5 MOUNTING AND INSTALLATION GUIDELINES Prior to Installation: Read and understand this entire manual. Should you have any questions before, during, or after installation please call your seller or contact VENTS at 888-640-0925 or install@ventsus.com. Check the product for any damage that may have occurred during shipping. Rotate the impeller by hand to ensure it turns smoothly. Mounting The Bucket Fan comes with a set of Hanging/Safety Cables with Gripples. The set consists of two Gripples and two cables with a toggle on one end. NOTE: The Hanging and Safety Cables are the exact same, so there is no need to worry about which one is which. NOTE: The toggle ends are the ones that are inserted into the handle. WARNING: Both the Hanging and Safety cables MUST be installed as directed. Fig. 2. Attaching the Bucket Fan with the Hanging Cable and Gripple.

6 Bucket Fan Tip: It is easier to attach the Hanging Cable and Gripple to the structure first and then attach the fan with the toggle. 1) Insert the cable into one of the openings in the Gripple 2) Place the cable over the I-beam, truss, or other structure from which it is being hung. 3) Insert the end of the cable into the other opening in the Gripple. 4) Adjust to desired height 5) Insert toggle into the top hole on the handle. Attaching the Safety Cable 1) Insert the cable into one of the openings in the Gripple 2) Place the cable over the I-beam, truss, or other attaching structure at a 40 0 to 50 0 angle 3) Insert the end of the cable into the other opening in the Gripple. 4) Insert toggle into the top hole on the handle. 5) Take the slack out of the safety cable by pulling the cable through the Gripple. NOTE: The cable should not be so tight as to be pulling the fan to one side. The cable should not be so loose that the cable could get caught or tangled in the motor. Hanging Cable Safety Cable Fig. 3

Bucket Fan 7 The Bucket Fan can be angled if needed. All it takes is a 13 mm socket wrench. Loosen the bolts on either side of the fan, place at the angle you want, then re-tighten the bolts. Fig. 4 1 2 3 Bucket Fan 4 5 BUCKET FAN PARTS 1) Electrical junction box on protective grille. 2) Vibration absorbing mount 3) Metal case 4) Handle 5) Handle bolts 6) Casing 7) Sound-Insulation Layer 8) Airflow Straightener 9) Wing Head bolt 6 7 8 9 Fig. 5 The destratificator (see Fig. 5) consists of an axial fan attached to the casing via the vibration mounts. The destratificator has a polymer coated steel casing. The destratificator is equipped with a singlephase asynchronous motor with an external rotor and an axial impeller. The motor is equipped with built-in thermal protection enabling its automatic restarting and utilizes rolling-element bearings. The motor protection class is IP 44. The casing has special perforation and a sound-insulating layer of mineral wool to reduce the noise generated by the axial fan. The destratificator has a flow straightener at the discharge which ensures direct air flow and maximum air throw distance. The destratificator is mounted by means of the bow bracket ( can be fixed with 15 steps) as well as the mounting and the safety cables with threaded joints.

8 Bucket Fan MAINTENANCE BEFORE PERFORMING ANY MAINTENANCE ALWAYS ENSURE THAT THERE IS NO POWER TO THE FAN, YOU MUST DISCONNECT THE ELECTRICITY AT THE MAIN POWER SOURCE! Annually: 1) Check to make sure the bolts are tight. 2) Check impeller for dirt or other matter. Clean if necessary. To clean, remove the four screws that secure the grille to the metal case. Remove the grille from the case and clean the blades with warm, soapy water. Avoid splashing water on the motor. Wipe surfaces dry. Also clean the inside of the metal case while you are at it. Re-attach the grille to the case. WIRING THE FAN Electrical wiring should only be done by a qualified electrician. Warranty will not cover equipment damage or failure that is caused by improper installation. If the fan did not come pre-wired or if a new wire is to be used, wire the fan as shown in the Figure 6 below. Use 18 AWG or greater wire. Bucket Fan 420 420 1.0 A Bucket Fan 1055 1055 1.0 A Bucket Fan 1460 1460 2.0 A All set screws must be checked, and retightened where necessary, before installation. Motor terminal box Motor run capacitor C1 X1 BLACK (LINE) GREEN (PROTECTIVE EARTH) WHITE (NEUTRAL) Fig. 6 ~120 VAC 60 Hz

Bucket Fan 9 CONTROLLER WIRING AND INSTALLATION The following is for the installation of one controller for one fan. Contact VENTS US if you need to operate two or more fans with one controller. Refer to Figure 7 for electrical connections. Use 18 AWG or greater wire. It is important that the controller be properly grounded for effective fan operation and personnel safety. Always install the controller in sight of the fan it controls. CAUTION: Incorrectly installed fan(s) and/or controller(s) may damage the equipment and void the warranty. From Fan ~120 VAC 60 Hz WHITE GREEN BLACK SPEED CONTROLLER RED BOX FOR SPEED CONTROLLER (pre-installed by user) WHITE GREEN TO POWER SOURCE ~120 VAC 60 Hz RED BLACK Fig. 7

10 Bucket Fan 1. Application a) Motor Type Shaded Pole, P.S.C. and Universal. b) Required Load Fans, Blowers and Speed Dependent Loads. 2. Wiring Warning! Power must be turned off before wiring. Connect control in series with motor and line voltage; never connect control across line. Ground (Earth)** Be sure to ground the control using the green wire. **Some models do not require grounding, therefore, a ground wire is not provided. 3. Mounting a) Use 2 deep standard electrical box. b) Secure control with outer bracket tabs. 4. Minimum Speed Adjustment Important: If this option is not supplied, disregard Step 4 and continue to Step 5. This control was designed to operate on motors used in diverse applications. A minimum speed adjustment is provided to allow independent control of the minimum speed setting. Minimum speed adjustment ensures motor runs with sufficient torque to prevent stalling. a) Motor must be in actual operating condition to achieve proper speed adjustment. Motor will not slow down unless proper load is applied. b) Turn main control knob to lowest speed position. c) Locate and adjust minimum speed setting on front plate with screw driver (rotate clockwise to decrease minimum speed; counter-clockwise to increase minimum speed). Special Note: For 2.5 and 3.0 Amp models, adjustment of minimum speed is reversed. Rotate clockwise to increase minimum speed; counter-clockwise to decrease minimum speed. On some models minimum speed adjustment hole is located on side of control. d) Motor will now operate from this preset minimum speed to full speed.

Bucket Fan 11 Connection Diagram for 2-Wire* Controls (Switch Models) Connection Diagram 2-Wire* Controls for No Switch Model (NS) L1 L1 Switch Triac Triac AC Line Green Ground (Earth)** Motor AC Line Green Ground (Earth)** Motor L2 L2 L1 AC Line Connection Diagram for 3-Wire* Controls (Switch Models) Black Green Ground (Earth)** Switch Triac Red Auxiliary Load Blue*** Motor Full Voltage L1 240 Volt L2 Connection Diagram for 4-Wire* Controls Red Red Green Black Black Variable Voltage Motor L2 *** Wire may be white in some applications Ground (Earth)** * Ground wire is not counted when designating 2,3 or 4 wire controls. ** Be sure to ground control using the green wire. Some models do not require grounding, therefore, a ground wire is not provided. *** Wire may be white in some applications. Fig. 8 TROUBLESHOOTING The fan does not start Model Possible reason Remedy The fan does not start (possibly with humming noise) Loud noise, vibration No power Object stuck in blades Loose screw Dirty impeller Have a qualified electrician check connections and power source. Turn off power. Remove object. Restart fan. Tighten screw Clean the unit according to directions in this manual. Please call Customer Service at 888-640-0925 with any other problems encountered. Should you need to store the fan for any length of time: STORAGE Store the fan in its original packaging in a ventilated area. Temperatures should not be below 41 or higher than 104 F. Humidity should not be above 80%. The fan must be stored in a non-corrosive environment. Avoid storing the fan in an area where it may be hit by a forklift, where it will have to be moved a number of times, etc.

12 Bucket Fan WARRANTY VENTS US warrants to the original purchaser of the Bucket Fan Series series fan that it will be free from defects in materials or workmanship for a period of 60 months from the date of original purchase. If the fan is installed with the speed controller the warranty period is decreased to 24 months. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During the stated warranty period, VENTS US will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service. This warranty does not cover (a) normal maintenance and normal service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by VENTS US), faulty installation or installation contrary to recommended installation instructions. Labor to remove and replace products is not covered. The duration of any implied warranty is limited to the time period specified for the express warranty. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. VENTS US OBLIGATION TO REPAIR OR REPLACE, AT VENTS US OPTION, SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. VENTS SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitations of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. This warranty supersedes all prior warranties. V96EN-03-1(USA_120)