Battery charger modules

Similar documents
Notification Appliance Circuit Module

Annunciators, 8 LED. D7030X, D7030X-S2, and D7030X-S8. Installation Manual

Duct smoke housing, 2-wire D340/D340P

Duct smoke housings, 4-wire D341/D341P and D342/D342P

D250A/D253/D261AW/D280A/D290 Series

Photo Beam 5000/3000 Series Heater. en Installation Guide

D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

F220-B6PS/M. Installation Guide. Addressable Detector Bases

Addressable NAC Output Module D327A

Control Panel. D9412GV4/D7412GV4 v2.00. en UL Installation Instructions

Control Panels D9412GV4/D7412GV4/D7212GV4. Approved Applications Compliance Guide

D9412GV2/D7412GV2. Approved Applications Compliance Guide. Control Panels

Remote NAC Power Supply D7038

DS7465i. Installation Instructions. Input/Output Module

Multiplex Eight Input Remote Modules

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

D7052. Installation Instructions Multiplex Dual Input Module

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

D7053. Installation Instructions Multiplex Input/Output Module

Fire Control/Communicator

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface

D7044. Installation Instructions Multiplex Single Input Module

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

FMR Installation Instructions. Addressable Fire System Controller

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Installation Guide. Control/Communicator

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

Installation Guide for models:

Model 17A00 Expansion Enclosure

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

D7212GV2. Operation and Installation Guide. Control Panel

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Fire Alarm Control Panels FPD-7024

FireNET Plus Wiring Instructions

Series. Access Power Controllers. Installation Guide

Bosch EVAX System - High-rise Applications

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

TECHNICAL DATA OBSOLETE

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

AL600ULX Series. Power Supply/Charger. Installation Guide

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

Installation Guide for models:

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

Commercial Series TriTech Motion Detector. Reference Guide

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

D2412 Control / Communicator Installation Manual

TrueAlert Addressable Notification

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

D720 and D1255 Command Centers

Control Panels B5512/B4512/B3512. en UL Installation Instructions

DS7400Xi Addressable Control/ Communicator

July 14, 1999 DF C-100.

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

MODEL B2 INSTALLATION MANUAL

Greentrol Automation, Inc.

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

AL800ULADA. NAC Power Extender. Installation Guide

D2071A. Operation & Installation Guide Fire Alarm Control Panel

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

D7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector

/9308 External Battery Chargers Installation Instructions

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

AL600ULADA. NAC Power Extender. Installation Guide

June 10, 2002 DF C S2424

RELEASE DEVICE CONTROLS

XR10/XR20 Command Processor Panels Installation Guide

Public Safety DAS Annunciator Panel

Operation and Installation Guide. Zone Expansion Module D8125

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

PSN-1000 & PSN 1000(E) Installation Manual

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

D7212 Control/Communicator Operation and Installation Manual

/5121/5122 TrueAlert Power Supply Installation Instructions

These instructions detail procedures to follow in order to avoid damage to equipment.

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Specification/ Data Sheet

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

D1255RB/D1256RB/D1257RB

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

I TS-12 1 Y K DO WHAT THEY DON T. Model. INSTALLATION lnstrljctlons. FIRE BURGLARY lnstrumentsrn INC.

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

Transcription:

Battery charger modules D8132 and D8132LT en Installation manual

Battery charger modules Notices en 3 1 Notices These instructions cover the installation of the D8132 Battery Charger and the D8132LT Battery Charger Less Transformer modules in an alarm system supervised by a fire alarm control panel (FACP), an intrusion alarm panel, or a combination Burglary/Fire control panel. These modules are UL Listed for use in Central Station, Household Fire and Burglary Alarm, Police Connection, and Electrically Actuated Transmitter applications. They can also be installed as non-ul Listed, 12 V, 1 A, standalone power supplies. To obtain any of the documents referenced in this document, download them from the Bosch website (www.boschsecurity.com). Install, test and maintain the module according to these instructions, NFPA codes, local codes, and the authority having jurisdiction (AHJ). Failure to follow these instructions can result in failure of a detector to initiate an alarm event. Bosch Security Systems, Inc. is not responsible for improperly installed, tested or maintained devices. Before installing the module, become familiar with the Installation and Operation Guide for the control panel you are using.! Warning! Follow these instructions to avoid personal injury and damage to equipment. NFPA 72 requires that you perform a complete system wide functional test following any modifications, repair, upgrades or adjustments made to the system s components, hardware, wiring, programming and software/firmware. Copyright This document is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved. Trademarks All hardware/software product names used in this document are likely to be registered trademarks and must be treated accordingly. Bosch Security Systems, Inc. Installation manual 2018.05 4.0 F.01U.036.305

4 en Description Battery charger modules 2 Description The module, combined with external batteries, increases the standby time and provides additional power to the auxiliary output of the compatible control panels listed in the following table. Control Panels See section: Active products: GV4 and GV3 panels 1 Wiring, page 6 Legacy products: GV2 and G panels 2 D6412 and D4412 panels D9412, D7412, D7212, D7212B1 See control panel s documentation on the Bosch website (http:// www.boschsecurity.com) D9112B1, D9112, D8112, D6112 D9124 2000-series panels 3 1 GV4 = D9412GV4, D7412GV4, & D7212GV4; GV3 = D9412GV3, D7412GV3, & D7212GV3 2 GV2 = D9412GV2, D7412GV2, & D7212GV2; G = D9412G, D7412G, & D7212G 3 2000-series = D2812, D2412, D2212, D2212B, D2212BE, & D2012 In addition to the batteries that can be installed with the control panel, two additional 12 V, 7 Ah batteries (D126) or up to two 12 V, 13.5 Ah batteries can be installed with the module. The module is ideal for systems requiring extended battery standby time, such as UL Bank Safe and Vault applications, and systems requiring additional auxiliary current output. In addition to providing increased standby time and auxiliary power, the batteries also filter the AC power supply. The amount of ripple that appears on the control panel outputs is dependent on the condition of the batteries. Notice! Bosch does not recommend using the module to power devices that are sensitive to excessive ripple. A 16.5 V, 40 VA transformer (D1640, supplied with the D8132) is required to power the module. A green LED on the module lights to indicate the presence of AC power. Provided with the D8132LT are two cables, and two sets of lockwashers, nuts, screws, and terminal lugs. The cables connect the module to the transformer, two batteries, and the control panel. The hardware is provided for connecting the battery cable to 12 V, and up to two 13.5 Ah batteries (this hardware is not used when connecting 12 V, 7 Ah batteries). 2018.05 4.0 F.01U.036.305 Installation manual Bosch Security Systems, Inc.

Battery charger modules Installation en 5 3 Installation The module and additional batteries are typically mounted inside a separate enclosure (such as, the D8103, the D8108A, or the D8109) adjacent to the control panel s enclosure. Figure 3.1: Module installation 1 Enclosure 3 Mounting locations 2 Module 4 Mounting screws (3) Install the module in one of the vertical mounting locations. The upper mounting location is recommended if two 12 V, 13.5 Ah batteries will be installed. Fasten the module in place with the three mounting screws provided. The green AC power LED on the module can be viewed if a knock-out is removed on the front door of the enclosure. Bosch Security Systems, Inc. Installation manual 2018.05 4.0 F.01U.036.305

6 en Wiring Battery charger modules 4 Wiring 4.1 Wiring for extending battery standby time and providing additional auxiliary current output If the module is to be connected to a control panel to increase stand by time, refer to the appropriate control panel s Installation and Operation Guide to calculate the total battery Ampere-hours (Ah) required for your system. The recharge time cannot exceed 48 hours for UL listed applications. Once satisfactory recharge time, standby time, Ampere-hour, and auxiliary current values are identified, determine the combination of batteries required for your application using the following table. 24 standby hours 60 standby hours 72 standby hours Total Aux current load Recharge time (hrs) Aux current load Recharge time (hrs) Aux current load Recharge time (hrs) battery Amp-hrs 430 ma 9 N/A N/A N/A N/A 12 550 ma 10 50 ma 7 10 ma 7 15 680 ma 11 100 ma 9 50 ma 9 18 800 ma 14 150 ma 10 90 ma 10 21 930 ma 17 200 ma 12 130 ma 12 24 1050 ma 21 250 ma 14 180 ma 13 27 Tab. 4.1: Battery requirement (Ah) Figure 4.1: Wiring for extended battery standby time and providing additional auxiliary current output 1 AC circuit common to both transformers 2 Transformers* 3 Control panel 4 D122 Dual battery harness 2018.05 4.0 F.01U.036.305 Installation manual Bosch Security Systems, Inc.

Battery charger modules Wiring en 7 5 Control panel batteries (as needed) 6 D8132 module 7** Additional batteries (as needed) 8 Gray wires connecting the D8132 module and the D1640 transformer 9 Red wires from positive battery terminals to the D8132 and the control panel and from the D8132 to the control panel 10 Black wires from negative battery terminals to the D81132 and the control panel and from the D8132 to the control panel * GV3 and GV4 panels require a D1640 transformer. For legacy products refer to the control panel documentation. ** The D8132 can support up to 27 Ah of backup battery. If two batteries are used they must have the same Ampere-hour (Ah) rating. Two cables are provided with the module for connections to the control panel and additional batteries. 1. Connect the black wire of the four pin connector cable to the control panel s battery negative terminal. 2. Connect the red wire of the four pin connector cable to the control panel s battery positive terminal.! Warning! Do not short these wires! 3. Plug the four pin connector cable into J1 on the module. 4. Connect the two grey wires to a separate 16.5 V, 40 VA transformer (D1640).! Warning! Do not connect the grey wires to the control panel s transformer terminals. 5. Connect the D1640 transformer to an unswitched 110-120 VAC 60 Hz outlet. Notice! Connect the D8132 and the control panel transformers to the same AC branch circuit. Do not share the transformers with any other devices. 6. Plug the six pin connector cable into J2 on the module. 7. Connect a red wire to the positive battery terminal, and a black wire to the negative battery terminal of each auxiliary battery. (One or two auxiliary batteries can be installed.) 4.2 Wiring for standalone power supply The D8132 module can operate as a 12 V standalone power supply. Standalone operation does not have battery supervision or load shed, and therefore is not recommended for critical loads requiring supervision. Bosch Security Systems, Inc. Installation manual 2018.05 4.0 F.01U.036.305

8 en Wiring Battery charger modules Notice! The D8132 Module is not UL Listed for standalone operation, and cannot be used in this configuration for UL applications. To determine the appropriate batteries for use with the module, see the table which displays auxiliary current and battery recharge values for various battery Ampere-hour combinations in the section Wiring for extending battery standby time and providing additional auxiliary current output, page 6. (These values will vary depending upon the condition of the batteries installed.) For standalone power supply operation, install the module as shown in the following figure. Figure 4.2: Wiring D8132 as standalone power supply 1 AC branch circuit (unswitched) 5 Devices 2 D1640 transformer 6 Gray wires connecting the D8132 module and the D1640 transformer. 3 D8132 module 7 Red wires from positive battery terminals to the D8132LT module. 4 Batteries 8 Black wires from negative battery terminals to the D8132LT module. 2018.05 4.0 F.01U.036.305 Installation manual Bosch Security Systems, Inc.

Battery charger modules Wiring en 9 Figure 4.3: Wiring D8132 to follow control panel indicators for AC power failure and restoral 1 AC circuit common to both transformers 2 Transformers* 3 Control panel 4 D122 D battery harness 5 Control panel batteries 6 D8132 module 7** D8132 batteries 8 Devices 9 Gray wires connecting the D8132 module and the D1640 transformer 10 Red wires from positive battery terminal to the D8132 and the control panel, and from the D8132 to the device loop. 11 Black wires from negative battery terminals to the D8132 and the control panel, from the D8132 to the device loop, and from the device loop ground to the control panel earth ground. * GV3 and GV4 panels require a D1640 transformer. For legacy products refer to the control panel documentation. ** The D8132 can support up to 27 Ah of battery backup. If two batteries are used, they must have the same Ampere-hour (Ah) rating. When the control panel and the module are connected to the same AC branch circuit, AC power failures and restorals which affect the control panel and the module will be indicated by the control panel. The standalone power supply standby time should be greater than that of the control panel system. The standalone power supply and the control panel must share a common ground. For this type of standalone power supply operation, install the module as shown in the following figure. Bosch Security Systems, Inc. Installation manual 2018.05 4.0 F.01U.036.305

10 en Troubleshooting Battery charger modules 5 Troubleshooting The LED on the module is used to indicate the operational status of the Battery Charger. The following table describes the different states of the LED. Symptom Diagnosis Remedy/description LED color LED status Green ON AC transformer power present No action OFF AC transformer power not present Check if the Transformer is plugged into a nonswitched outlet. Check 120 VAC supply to outlet. Check if transformer has a faulty secondary; fuse may be blown. Tab. 5.2: LED status troubleshooting To insure the module is not faulty, meter the battery leads of the module. A reading of 13.80 VDC or higher indicates the unit is functioning normally. 6 Specifications Electrical Float Voltage 1 Supplied Voltage Supplied Current Ampere-hours 13.9 VDC maximum 16.5 VAC, 40 VA supplied by D1640 plug in transformer 1.2 A 27 Ah maximum 1 measured with batteries in circuit Mechanical Dimensions (HxWxD) 0.75 in. x 3.0 in. x 5.0 in. (1.9 cm x 7.6 cm x 12 cm) 2018.05 4.0 F.01U.036.305 Installation manual Bosch Security Systems, Inc.

Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450 USA www.boschsecurity.com Bosch Security Systems, Inc., 2018 Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany