Bulletin FH05 FUME EXHAUST

Similar documents
A. Codes and Standards that are Standard at the University:

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Bulletin ZC05 ZEPHYR CABINET FANS. Models: ZC, ZCC Single and Twin Unit Belt Drive Cabinet Fans

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Product Handbook. Moving Your Way. Our Complete Product Offering. PennBarry Manufacturer of Ventilation Products

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

PRODUCT HANDBOOK A Complete Product Overview

Turning Air Into Solutions. TUBEAXIAL PAINT SPRAY BOOTH EXHAUST FANS. Model TCBS

MXI Mixed Flow Inline Fan

Selecting the Correct Fan

SECTION (15833) - HVAC POWER VENTILATORS

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Introduction to Fans. The Basics of Fan Principles and Terminology

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Direct Fired Heater Model AD Specification

PENNBARRY COMMERCIAL AND LIGHT INDUSTRIAL FANS

Installation & Maintenance Instructions

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

SECTION AXIAL FANS

University of Houston Master Construction Specifications Insert Project Name

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Twin City Fan & Blower

User s Manual and Operating Instructions

Propeller Fans. Industrial And Commercial Fans Belt And Direct Drive. Your Clean Air Source!

Belt Driven Mixed Flow Fans

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

Industrial Fans & Blowers

SECTION AIR HANDLING UNIT

Evase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

SECTION AIR DUCT ACCESSORIES

MaxLite LED MICRO-T PANEL

Indirect Gas-Fired Make-Up Air

INSTRUCTION MANUAL HS-229G

CVS Model Inline Multi-Port Ventilators

1.1 This section applies to air handling units for HVAC Systems.

"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

M Series Fan Filter Units

Installation & Maintenance Instructions

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

Design Criteria. Installation

Modular Supply Make-Up Air Unit

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

Fans: Features and Analysis

DBF 4XL Dryer Booster Fans

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

Quest Power Electric Heat EHS 62 Pro

User s Manual and Operating Instructions

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

IMPORTANT SAFETY INFORMATION

User s Manual and Operating Instructions

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

e Bath Fan with Light User s Guide

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Preaction Fire Protection Package General Description

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Honeywell Garrett Drop-in Intercooler for 2.3L Mustang EcoBoost IMPORTANT INFORMATION - PLEASE READ CAREFULLY

BESF Box Ventilator. Installation & Operating Manual USA CAN READ AND SAVE THESE INSTRUCTIONS

Glossary of Terms Laboratory & Fume Exhaust Fans

Installation, Operation, and Maintenance Manual

Easy installation in both new construction and retrofit

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

CML Northem Blower Inc. Air Movement Equipment

Easy installation in both new construction and retrofit

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

GASGUARD H 2-1% Hydrogen Sensor OPERATING & INSTALLATION MANUAL

e Bath Fan with Light User s Guide

MH70230AS MH70236AS MH70248AS

Model DV-5 Red-E Cabinet 1-1/2 thru 8 Inch (DN40 thru DN200), 250 psi (17,2 bar) Integrated Deluge Fire Protection Package General Description

5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

Energy Guide. Fan Efficiency Grades. FEG Ratings. July

Compact Equipment Warranty Policy

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

Owner s Manual Phoenix Aquadry TX 200

Ducted Propeller. Airflow Volume

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

SECTION DIRECT GAS-FIRED INDUSTRIAL HEATING AND VENTILATING UNITS

e Bath Fan with Light User s Guide

DEDPV-705, DEDPV-705 Hi Alt Dryer Exhaust Duct Power Ventilator (DEDPV)

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

USER GUIDE. This manual covers the description, cautions, operation and maintenance of Super Vac confined space electric ventilators CONTENTS

INSTALLATION AND OPERATING MANUAL

Electric Duct Heaters

Modular Heating & Ventilating Unit Model IGX-HV

Breezex (BX) Heavy Duty Reversible Supply/Exhaust Fans with Reversing Switch. IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

Transcription:

Bulletin FH05 FUME EXHAUST Models: FH, FHL Curb Mounted Centrifugal Fans

Fume Exhaust Systems - FH/FHL Introduction The PennBarry FH fans are designed to meet the various requirements for fume exhaust systems. PennBarry s exclusive discharge venturi design allows the selection of the discharge velocity to meet the code requirements for high velocity discharge to atmosphere. Discharge velocities from 1250 FPM to 4000 FPM can be obtained by fan selection as required for the particular application. To obtain the required discharge velocity it is necessary to accelerate the air flow from the fan outlet velocity up to the required discharge velocity. Some static pressure will be required to accelerate the air which will need to be added to the system pressure requirements in order to determine the fan performance requirements. The PennBarry FH Series fans accomplish the required acceleration with a minimum pressure loss. Features and Capabilities Roof curb mounted Backward inclined centrifugal fans Class I and II duty Flow capacities from 350 to 80,000 CFM System pressures up to 8 inches w.g. The standard FH fans have a discharge height 7 feet above the roof level, and can be supplied with discharge heights up to 20 feet. The FHL fans have a lower discharge height for applications requiring only a minimum of 40 inches discharge height. The PennBarry FH systems are supplied with an integral gravity backdraft damper for weather protection of the system and elimination of backdrafts caused by the wind, or building negative pressures when the fan is not operating. Standard FH fans are suitable for continuous operation with exhaust air temperatures up to 150 F. For exhaust temperatures up to 300 F, the FH fans are available with an optional forced air ventilation system to cool the bearing and motor compartment. FH Fan The FH fan has a discharge height of 7 feet as standard, and is available with an extended stack for up to 20 feet discharge height. Stack heights greater than 10 feet will require guy wires for support. The venturi discharge allows for selection of the discharge velocity required for the application. FHL Fan The FHL fans have all of the features of the FH fans, but are designed to have a lower discharge height. FHL fans can be used in applications where only 40 inches of discharge height is required. FANSIZER Product Selection Software FanSizer software allows you to select the best centrifugal or axial unit for your application. Input CFM and static pressure, and FanSizer will make the optimum selection. It allows you to complete job schedules which you can store, modify and print in seconds. Features include: on-line help, on-screen product drawings and dimensions, and complete text specifications. In addition, you can convert job schedules to ASCII code for use with other programs like word processing. Due to the large number of available configurations the selection of this fan is accomplished with PennBarry s product selection software. Consult your representative or our factory if you need assistance. 2005 PennBarry All rights reserved. Following publication of this catalog changes may have been made in standard equipment, options and the like that would not be included. We reserve the right to make changes at any time, without notice, to models, specifications, options, availability, etc. This bulletin illustrates the appearance of PennBarry products at the time of publication and we reserve the right to make changes in design and construction at anytime without notice. Your local sales representative is the best source for current information. PENNBARRY 1

Options and Accessories FH/FHL - Fume Exhaust Systems Discharge Cap and Damper PennBarry FH fans have a unique discharge cap with a deep spun steel discharge venturi sized to control the discharge velocity as required by the application with minimum pressure loss. The discharge cap features a gravity operated damper to prevent backdrafts when the fan is not operating. The damper is protected by an encircling windband. The damper is furnished with large hinge pins that rotate in oil impregnated bronze bearings for maintenance free operation. Backward Inclined Centrifugal Wheel PennBarry's high efficiency, non-overloading backward inclined wheel provides desirable performance characteristics for exhaust application. Precision formed blades are welded to the spun shroud for a very rugged wheel construction. Wheels are statically and dynamically balanced. Fan Housing FH fans utilize an inline centrifugal fan design. The housing is of heavy gage steel and all-welded construction. The bearing assembly is contained in a tapered tube that is completely welded. PennBarry s unique flow conversion vanes efficiently convert the flow from the wheel to an axial direction and maximize static regain. A deep, spun inlet cone provides for close running clearance at the wheel inlet with a minimum of turbulent losses. Bearings and Shaft FH fans are equipped with cast iron, self-aligning pillow block bearings. Lubrication lines are extended to the outside of the fan for ease of maintenance. Bearings are sized for long trouble-free life, and the shafts are precision ground for precise fit with bearings. The fan wheel and drive pulley are securely fastened to the shaft with keys and set screws. Drives All units up to 7-1/2 horsepower are furnished with adjustable pitch drives, providing speed adjustments to meet the application. All drives are based on a minimum 1.2 service factor for long life. Two belt drives are available as an option. Sheaves are precision machined, cast iron construction. Belts can be changed from the exterior of the fan. Galvanized Curb Caps FH fans are provided with heavy gage steel, all welded curb caps that are HOT DIP GALVANIZED after fabrication to provide a leakproof design, and exceptionally long life. The curbs have a WIRING POST to facilitate running of conduit to the motor. A slip-fit duct connection collar is built into the curb cap for connection of the system ductwork. The use of a flexible duct connector is recommended to reduce noise transmission to the ductwork. Prefab Curbs Heavy gage galvanized prefab roof curbs, sized to match the fan are available. Standard curbs are 12 inches high and are also available in single or double pitch. Weather Cover The FH fans are equipped with a galvanized weather cover to protect the motor and drive from the elements. The cover is easily removed for access to the motor and drive. Belts can be replaced from the exterior of the fan. Motors FH fans are furnished with open drip proof, totally enclosed or explosion proof motors to meet specification requirements. Special duty motors are available upon request. Finish FH fans are painted with a high grade grey industrial enamel which is attractive and functional. The windband is made of galvanized steel and the curb cap is hot-dip galvanized after fabrication. Shaft Steel FH fans can be provided with a Teflon, minimum leakage shaft seal as an option, (not gas-tight). Shaft seals are recommended on applications handling corrosive or toxic fumes, and are furnished as standard on AMCA B and C, spark resistant construction. Access Door A gasketed access door can be provided for access to the wheel. The PennBarry access door is provided with a nut and pawl hold down for quick opening. Extended Stack The FH fans can be provided with discharge heights up to 20 feet above the roof level. Discharge heights over 10 feet will require guying furnished by the user. Guy lugs are provided. Specify desired discharge height. Discharge heights are based on installation on a 12-inch high roof curb. Disconnect Switches Nema 3R or Nema 4 disconnect switches are available as an accessory. Switches are factory mounted and can be furnished wired when specified. Drain Threaded drain connections can be provided, located at the lowest point of the fan housing. Drain plugs are not furnished. AMCA B or C Spark Resistant Construction FH fans are available in AMCA B or C spark resistant construction as defined in AMCA Standard 99-0401-82. Shaft seals are standard on AMCA B or C construction. The user is required to electrically ground all fan parts. Special Protection Coatings PennBarry FH fans can be provided with Teflon-P* coating in the air stream. Teflon-P* is inert to almost all chemicals and provides the widest range of corrosive protection of any coating. Contact Penn Ventilation for information on a wide range of special paints and coatings are available for corrosion protection. * Registered trademark of E.I. DuPont Co. 2 PENNBARRY

Dimensional Data Fume Exhaust Systems - FH/FHL FH and FHL Series (Sizes 90-245) FH Series (Sizes 270-490) PennBarry maintains a policy of continuous improvement. Specifications and dimensions may be changed without notice. Dimensional Data MODEL NUMBER A BFH B FHL C D E F APPROX. WT. (lbs.)* FH90-50 30 86 407/8 125/8 14 5 153/16 270 FH90-60 30 86 407/8 125/8 14 51/2 153/16 270 FH105-50 30 86 441/2 145/8 16 51/2 1511/16 315 FH105-60 30 86 441/2 145/8 16 6 1511/16 315 FH105-65 30 86 441/2 145/8 16 61/2 1511/16 315 FH105-70 30 86 441/2 145/8 16 7 1511/16 315 FH122-60 30 89 511/2 167/8 181/4 6 199/16 360 FH122-65 30 89 511/2 167/8 181/4 61/2 199/16 360 FH122-70 30 89 511/2 167/8 181/4 7 199/16 360 FH122-80 30 89 511/2 167/8 181/4 71/2 199/16 360 FH122-90 30 89 511/2 167/8 181/4 83/4 199/16 360 FH122-10 30 89 511/2 167/8 181/4 93/4 199/16 360 FH122-11 30 89 511/2 167/8 181/4 11 199/16 360 FH135-10 33 91 553/4 185/8 21 10 199/16 430 FH135-11 33 91 553/4 185/8 21 11 199/16 430 FH135-12 33 91 553/4 185/8 21 12 1911/16 430 FH135-13 33 91 553/4 185/8 21 13 1911/16 430 FH150-12 33 91 583/4 205/8 23 12 203/16 480 FH150-13 33 91 583/4 205/8 23 13 203/16 480 FH150-16 33 91 583/4 205/8 23 16 203/16 480 FH150-18 33 91 583/4 205/8 23 171/2 203/16 480 FH165-16 38 91 611/2 223/4 251/8 16 211/8 560 FH165-18 38 91 611/2 223/4 251/8 171/2 211/8 560 FH165-19 38 91 611/2 223/4 251/8 19 211/8 560 FH182-19 38 91 643/4 251/8 271/2 10 237/16 630 FH182-21 38 91 643/4 251/8 271/2 201/2 237/16 630 FH200-21 40 91 677/8 271/2 297/8 201/2 2611/16 715 FH200-22 40 91 677/8 271/2 297/8 22 2611/16 715 FH222-22 44 91 731/2 303/4 331/8 22 2611/16 790 FH222-24 44 91 731/2 303/4 331/8 231/2 2611/16 790 FH245-24 44 91 781/4 333/4 361/4 231/2 2611/16 850 FH245-26 44 91 781/4 333/4 361/4 251/2 2611/16 850 FH245-28 44 91 781/4 333/4 361/4 271/2 2611/16 850 FH245-30 44 91 781/4 333/4 361/4 30 2611/16 850 FH270** 50 911/2-371/2 42 363/8 2611/16 1025 FH300** 54 101-415/8 48 363/8 2615/16 1350 FH330** 58 113-453/4 48 427/16 2815/16 1500 FH365** 63 1191/2-501/2 54 481/2 2815/16 1800 FH402** 68 1303/4-555/8 54 549/16 2915/16 2460 FH445** 74 1461/4-611/2 66 605/8 3313/16 3200 FH490** 80 1511/2-673/4 66 605/8 3313/16 3850 * Less motor and drive. ** Consult factory for performance, price and availability. PENNBARRY 3

One Year Limited Warranty Fume Exhaust Systems - FH/FHL What Products Are Covered PennBarry Commercial and Industrial Fans (each, a PennBarry Product ) One Year Limited Warranty For PennBarry Products PennBarry warrants to the original commercial purchaser that the PennBarry Products will be free from defects in material and workmanship for a period of one (1) year from the date of shipment. Exclusive Remedy PennBarry will, at its option, repair or replace (without removal or installation) the affected components of any defective PennBarry Product; repair or replace (without removal or installation) the entire defective PennBarry Product; or refund the invoiced price of the PennBarry Product. In all cases, a reasonable time period must be allowed for warranty repairs to be completed. What You Must Do In order to make a claim under these warranties: 1. You must be the original commercial purchaser of the PennBarry Product. 2. You must promptly notify us within the warranty period of any defect and provide us with any substantiation that we may reasonably request. 3. The PennBarry Product must have been installed and maintained in accordance with good industry practice and any specific PennBarry recommendations. Exclusions These warranties do not cover defects caused by: 1. Improper design or operation of the system into which the PennBarry Product is incorporated. 2. Improper installation. 3. Accident, abuse or misuse. 4. Unreasonable use (including any use for non-commercial purposes, failure to provide reasonable and necessary maintenance as specified by PennBarry, misapplication and operation in excess of stated performance characteristics). 5. Components not manufactured by PennBarry. Limitations 1. In all cases, PennBarry reserves the right to fully satisfy its obligations under the Limited Warranties by refunding the invoiced price of the defective PennBarry Product (or, if the PennBarry Product has been discontinued, of the most nearly comparable current product). 2. PennBarry reserves the right to furnish a substitute or replacement component or product in the event a PennBarry Product or any component of the product is discontinued or otherwise unavailable. 3. PennBarry s only obligation with respect to components not manufactured by PennBarry shall be to pass through the warranty made by the manufacturer of the defective component. General The foregoing warranties are exclusive and in lieu of all other warranties except that of title, whether written, oral or implied, in fact or in law (including any warranty of merchantability or fitness for a particular purpose). PennBarry hereby disclaims any liability for special, punitive, indirect, incidental or consequential damages, including without limitation lost profits or revenues, loss of use of equipment, cost of capital, cost of substitute products, facilities or services, downtime, shutdown or slowdown costs. The remedies of the original commercial purchaser set forth herein are exclusive and the liability of PennBarry with respect to the PennBarry Products, whether in contract, tort, warranty, strict liability or other legal theory shall not exceed the invoiced price charged by PennBarry to its customer for the affected PennBarry Product at the time the claim is made. Inquiries regarding these warranties should be sent to: PennBarry, 1401 North Plano Road, Richardson, TX 75081. 4 PENNBARRY

OTHER PENNBARRY PRODUCTS CENTRIFUGAL PRODUCTS Domex Centrifugal Roof Exhausters Fumex Fatrap Kitchen Hood Centrifugal Roof Exhausters Zephyr Ceiling and Inline Fans Dynamo Centrifugal Blowers Centrex Inliner Centrifugal Inline Fans LC Dynafan Low Contour Centrifugal Roof Exhausters ESI Efficient Silent Inline Fan Fume Exhaust Curb Mounted Centrifugal Fans AXIAL / GRAVITY PRODUCTS Breezeway Propeller Wall Fans HI-EX Power Roof Ventilator Tubeaxial Inline Fans Vaneaxial Inline Fans Powered Airette Axial Roof Ventilators Airette Gravity Intake/Relief Hood Domex Axial Axial Roof Ventilators Axcentrix Bifurcator Fan For more information contact your local PennBarry Sales Manufacturer Representative or visit us at www.pennbarry.com 2005 PennBarry All Rights Reserved. February 2005