CENTRO-MATIC - 278B. Model Controller Series C JAN Section - C8. Form Page. Indicates change

Similar documents
Centro-Matic Automated Lubrication Systems System Controls

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

INSTALLATION INSTRUCTIONS

Power Supply Display Module PSDM. Installation and Operation Manual

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Operating Instructions. For. Alarm Control Module. Model SSR 500

OPERATING INSTRUCTIONS

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

SAFETY INFORMATION AND WARNINGS

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

EATON DFDAP-M / FDAP-M Remote Alarm Panels

Motogard. Over Temperature Protection System. Installation Instructions

DEMA TITAN EP II WAREWASH CONTROL TE.812 & TE.813 SERIES

POWERFOIL X3.0 ELECTRICAL SPECS & DIAGRAMS

vibration switch

Owner s Manual RD432-0 Chemical Controller

Corning LSE 6L Digital Water Bath

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

EHA Hoffmann International GmbH

AL600ULADA. NAC Power Extender. Installation Guide

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

DIESEL Engine Fire Pump Controllers Features

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

"VIP 2" ADVANCED LUBRICATION CONTROLLER

ELP21LU3-LF-HLOL THREE CHANNEL

ClimaGuard Outdoor Heat Exchanger All Models

Operations Manual. Motion Detector Module Model ZS10

Cable Actuated Sensor Industrial User Scalable VDC Output

OPERATION AND MAINTENANCE MANUAL ELC-810 AUTOMATIC WATER LEVEL CONTROLLER. AquatiControl Technology

Flopurge TS. Operation Manual

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

DIESEL Engine Fire Pump Controllers Features

LMA LINE MONITOR ALERT USER S MANUAL

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Open Protocol Data Communications

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

Beacon 800 Gas Monitor Operator s Manual

STEAMPRO. Steam Generator Troubleshooting and Service Guide

CADDY CORPORATION. Utility Distribution Systems

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS

MODEL UC1 INSTALLATION INSTRUCTIONS

NEWGATE TECHNOLOGIES, INC.

Pump-Down Controller MODEL 4052

Model 4001 Series Single Channel Controller

AL800ULADA. NAC Power Extender. Installation Guide

Transfer Switch Features

IMR 5000 Operating Manual S/N: SAMPLE For information only! IMR Environmental Equipment Inc.

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Ramsey Motion Monitoring Systems

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

OPERATIONS MANUAL DALPH1002, DALPH1503 PELLET HEATERS PALPH1002, PALPH1503 PLATE HEATERS. Alliance Products, LLC Murfreesboro, TN

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

M790 ph/orp Controller. Owner s Manual

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Transfer Switch Features

INTRODUCTION / TABLE OF CONTENTS

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

Installation, Operating and Maintenance Manual

Noran Tel. FUSE PANEL Technical Practice N NCY 2/2 KLM and 4/4 GMT NEBS Level 3 Certified

Table of Contents. T538 Instruction Manual Rev # 6 June R6T538 June rtf E L Switchgear and Control Inc

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

Installation Instructions

Field Start-Up Sheet Direct Fired Gas Equipment

Cable Actuated Sensor Industrial User Scalable 4 20mA

FUSE PANEL. Technical Practice N N/L33 10/10 GMT Front Access NEBS Level 3 Certified

Safety Photo Beam UL MONITORED DEVICE

Carbon Monoxide (CO) Detecting Ventilation Fan Controller Model 120VC Single Relay (100/25 PPM) (200/35 PPM)

SP-1000X. Panic Device Power Controller Installation Guide. Rev

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Installation/Owner s Manual Models 1504 / 1506

SEC 2000 Millenium Infrared Gas Detector

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

RATIO:GUARD Model E-1S EC Monitor

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

AM1 alarm module. RESOL AM1 alarm module * * Mounting Connection Function. Manual

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

Unfired Steam Generators (Series RB) Installation, Operation and Maintenance

FUSE PANEL. Technical Practice N N/0803 5/5 GMT Front Access NEBS Level 3 Certified

ERD97P21-U Receiver. Installation/ Operation Manual C939M-D (7/00)

B-40/B-41 Modulating Temperature Controller

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

OPERATION AND INSTALLATION MANUAL

Operating Manual SEVi 160 Series

GAS MONITOR Model Model

Transcription:

Model 85535 Controller Series C JAN - 06 Section - C8 Page - 278B

Table of Contents Safety...2 Controller Operation...2 Description...2 Field Connections...3 Wiring Diagram...3 Contoller Components and Setting the Controller...4 Repair Parts List...4 Dimensions...5 Troubleshooting...6 Safety Read and carefully observe these operating instructions before unpacking and operating the controller! The controller must be operated, maintained and repaired exclusively by persons familiar with the operating instructions. Local safety regulations regarding installation, operation and maintenance must be followed. Operate this controller only after safety instructions and this service manual are fully understood. Page Number - 2 This symbol identifies the potential for a hazardous situation. If this warning is not followed, a serious injury could occur. Controller Operation The time between lube events is determined by the setting of the rotary switch, which selects the numeral setting, and the dipswitch, which selects the units in either minutes or hours. When used in the timer mode, the pump will remain on for the amount of time that was selected by the dipswitch. Time will be either 30 seconds or 2 minutes (see Timer Mode). When used in the controller mode, the amount of time that the pump is on is determined by the closing of a pressure switch in the lube supply line (see Controller Mode). Failure of the pressure switch to close within the time setting of the dipswitch, either 30 seconds or 2 minutes, will result in an alarm condition. The alarm LED will turn on and the alarm contact will close. The controller will continue to initiate lube cycles while in alarm. When the low-level switch closes, the alarm LED will turn on and the alarm contact will close. The controller will continue to initate lube cycles while in alarm. Alarm condition will remain until low-level switch opens. Pressing the manual lube button on the enclosure cover will always initiate a lube event. The memory feature will work as follows: Dipswitch set to Memory Off Will result in a lube cycle each time power is turned on. Lube cycle will start at the beginning of the on time setting. Dipswitch set to Memory On 1. Power is turned off during the off time (time between lube cycles). When turning power back on will cause the lube cycle to continue from the point of interruption. 2. Power is turned off during the on time or pumping time. Turning power back on will cause the lube cycle to start at the beginning of the on time setting. Timer Mode When the dipswitch is set to the timer mode, amount of time that the pump is on will be determined by the setting of the dipswitch. Time will be either 30 seconds or 2 minutes. Controller Mode When the dipswitch is set to the controller mode, a pressure switch must be installed in the lube supply line. This will provide pressure-monitoring capabilities. The pressure switch will reset the controller when the set pressure is detected. The controller will initiate an alarm when the pump fails to develop sufficient pressure to actuate the pressure switch within the dipswitch setting of 30 seconds or 2 minutes. Description General Description Model 85535 controller is used to program the cycle frequency of a lubrication pump. Lube cycles are determined by the setting of internal switches. The cycles times are selected to meet system requirements. During the ON time, the air to the pump solenoid will be energized. Appropriate Use Model 85535 is exclusively designed for use in a Centralized Lubrication System. The maximum ratings given should not be exceeded. Any other use not in accordance with the instructions will result in loss of claim for warranty and liability. Product Specification: Input Voltage: 21 VDC to 30 VDC Current Consumption: 100 MA (less external load) Load Relay Contact: 2 amps inductive load at 30 VDC Alarm Relay Contact: 2 amps inductive load at 30 VDC Enclosure: NEMA 12 Temperature Range: -40 F to 150 F (-40 C to 65 C) Net Weight: 4 lbs. Off Time (adjustable): 30 seconds minimum 30 hours maximum On Time: 30 seconds minimum 2 minutes maximum Lubrication System: Centro Matic

Field Connections Terminal Strip 1 through 8 Terminal Strip 1 through 4 Terminal 1 Bat + Terminal 2 Bat - Terminal 1 Terminal 2 Low level switch (closes to indicate an alarm) Terminal 3 Terminal 4 24 VDC source for external air to pump solenoid. Terminal 3 Terminal 4 System pressure switch (closes to end lube cycle). Only used in the Controller Mode. Terminal 5 Terminal 6 Dry alarm contact (contact closes on fault) Observe correct polarity for Terminals 1, 2, 3 and 4. Terminal Strip AB Terminal A Remote Normally Open Terminal B Manual Lube Switch Illustration 1 Wiring Diagram 1. Incoming Power: 24 VDC. 2. 24 VDC Air Solenoid Valve. 3. Optional Alarm wired by customer. 4. Keypad with indicator lights and manual lube push button. 5. Optional Low Level Switch wired by customer. 6. Pressure Switch wired by customer. Not needed if used in the timer mode. 7. Remote Manual Lube Switch. Page Number - 3

Controller Components and Setting the Controller Mode Switch Identification - See Illustration 2 30 seconds or 2 minutes - Select the maximum amount of On Time. Timer or Controller - Select Timer Mode or Controller Mode. Hours or Minutes - Select units for the Off Time used with the Rotary Switch. Memory Off or Memory On - Select memory feature. Off Time Switch - See Illustration 2 Using the Rotary Switch you can select.5, 1, 2, 4, 8, 15, 24 or 30. The units are either minutes or hours as determined by the mode switch setting. Enclosure Cover - See Illustration 2 Green LED - Indicates that power is applied to the controller. Green LED - Indicates that the pump is on. Red LED - Indicates an alarm condition. Manual Lube - Pressing will initiate a lube cycle. Repair Parts List Item Quan. Description Part Number 1 1 Timer Board 250599 2 1 Keypad Ass y 249695 1 2 Illustration 2 Page Number - 4

3 1/2 (89 mm) 5/16 (8 mm Dia. Mtg. Holes) (4 places) 7-1/2 (191 mm) 6-3/4 (171 mm) Conduit Hole 2 (51 mm) 4-15/16 (125 mm) Dimensions Conduit Plug Page Number - 5

Lube System without Alarm Monitoring Condition Possible Cause Corrective Action Controller does not operate. No electric power to controller. Turn on electric power to pump. Power L.E.D. should light, PUMP ON L.E.D. should light when MANUAL LUBE is pressed. PUMP ON L.E.D. lights, but load Printed circuit board failure. Remove and replace. connected to terminals 3 & 4 will not energize. Load connected to terminals 3 & 4 Printed circuit board failure or Remove and replace. energized, but PUMP ON L.E.D. keypad failure. does not light. Bearing points are over lubricated. Timer/Controller memory mode Turn on memory mode of timer/controller. is set to off. Injector output adjustment setting Readjust to lower setting. too high. Bearing points are under Timer/Controller cycle time Set to longer cycle time or reevaluate lube lubricated. setting too low. requirements. Injector output adjustment setting Readjust to right setting. too low. Timer/Controller cycle timer Set to shorter cycle time or reevaluate lube setting does not deliver lubricant requirements. often enough. System too large for pump output. Calculate system requirements per planning manual. Additional Troubleshooting when Alarm Monitoring is used Some, but not all, of the injectors Timer/Controller is set to Timer. Set Timer/Controller to Controller Mode. are delivering lubricant. There is Pressure switch setting is too low. Adjust pressure setting to setting high enough for no alarm condition. all injectors to cycle. Lube Alarm L.E.D. turns and Bad electrical connection between Check all wiring between Pressure Switch and stays on. Pressure Switch and Timer/ Timer/Controller. Controller. Pressure switch setting is too Adjust pressure switch to setting high enough for high. all injectors to cycle. Pressure Switch is defective. Repair or replace. Printed circuit board is defective. Replace printed circuit board. Low level switch wired incorrectly. Check low level switch wiring and correct if necessary. Contact closure must be on low level condition. Low system air pressure. Increase air pressure. Americas: One Lincoln Way St. Louis, MO 63120-1578 USA Phone +1.314.679.4200 Fax +1.800.424.5359 Europe/Africa: Heinrich-Hertz-Str 2-8 D-69183 Walldorf Germany Phone +49.6227.33.0 Fax +49.6227.33.259 Asia/Pacific: 51 Changi Business Park Central 2 #09-06 The Signature Singapore 486066 Phone +65.6588.0188 Fax +65.6588.3438 Copyright 2006 Printed in USA Web site: www.lincolnindustrial.com Page Number - 6