CDP 40T SWIMMING POOL DEHUMIDIFIER FEATURES

Similar documents
CDP 40 SWIMMING POOL DEHUMIDIFIER

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

RAMIRENT CDT 30. Applications Damage service Building drying Water works Dry storing FEATURES

Applications Damage service Building drying Water works Dry storing FEATURES

Pool dehumidification for comfort and wellness

PRODUCT RANGE DEHUMIDIFIERS. For domestic and commercial garages and car storage facilities

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

PRODUCT RANGE RESIDENTIAL. Hot water heating, dehumidification, residential ventilation

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

LAF 50 / 100 / 150. Condensing dehumidifiers for professional use. Accessories. Design. Approvals LAF

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

DEHUMIDIFIERS & VENTILATORS

CAIRfricostar CAU Controller with Remote Control SUPPLEMENT TO OPERATION MANUAL

DEHUMIDIFIERS FOR SWIMMING POOL. International. ET INTERNATIONAL S.r.l. Via Circonvallazione Est, 32/R Castelfranco Veneto - TREVISO - ITALY

POOL HEATING. Making Heat something Cool

GHE Dehumidifiers for radiant cooling systems with heat recovery

TECHNICAL INFORMATION DanX Swimming Pool Air Management

Technical Information HXV - HRV Ventilation

Just feel well. 2017/2018 Air conditioning

SWIMMING POOL SWIMMING POOL DEHUMIDIFICATION

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

PRODUCT RANGE DEHUMIDIFIERS. For water damage and restoration

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

SPECTRACOOL INDOOR/OUTDOOR

TECHNICAL INFORMATION HCC 2 Home ventilation unit for suspended ceiling

FHE. Dehumidifiers for radiant cooling systems with heat recovery. Display. Versions

5736 N. Michigan Road Indianapolis, IN 46228

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

HT V2 HT Split

FH - GH Dehumidifiers for radiant cooling systems

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

5736 N. Michigan Road Indianapolis, IN 46228

FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

nemo 5,4 30,5 kw 6,4 37,4 kw R410A PLATE water cooled chillers / heat pumps and motoevaporating units COOLING HEATING

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

DSR SERIES DEHUMIDIFIERS ENGLISH GENERAL INFORMATION EXPLODED VIEWS DSR-20 DSR-12 PARTS LISTS ATTENTION!

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

G /6000 BTU/Hr. 1172/1758 Watt

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

TopVent Design Handbook

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

G /6000 BTU/Hr. 1172/1758 Watt

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

SPECTRACOOL Indoor & Outdoor Air Conditioners

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

LZT High efficiency air to water heat pumps with E.V.I. compressors

G E N E R A L C ATA L O G Dehumidif ers

COLDPACK_. water cooled chillers / heat pumps and condenserless chillers

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

SPECTRACOOL Indoor & Outdoor Air Conditioners

TECHNICAL INFORMATION DanX XD & DanX HP Swimming pool air management

VA G 052 S

High temperature air-to-water heat pumps

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

EBAC MODEL CD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

AIR CONDITIONING & VENTILATION PLANTS

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

POOL HEATING CATALOGUE 2017 YEAR WARRANTY

SILENT 12 PORTABLE AIR CONDITIONER USER MANUAL

Küba SG commercial

Multi Inverter Air Conditioning Condensing Units - Summary

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

N Volt 1800 BTU/Hr. 527 Watt

VENTILATION. Effective heat exchange and fresh air ventilation

Air Curtains. For a better working environment. Tel:

PRODUCT OVERVIEW. Dehumidifiers

ASTRALPOOL HEAT PUMP CATALOGUE

SWIMMING POOL HEAT PUMPS

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

Installation and Operation Guide For

Concealed Ducted Split Series R-407C MBH

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

SDU A. SDU A Loops. (available in 3, 4, 5 loops) Water Based Systems. Standard Distribution Unit assembled with: A Blank Port (capped)

Conditioning your ambient, maximising your comfort.

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

PRODUCT RANGE POOL HEATING AND COOLING. Swimming pool heat pumps, heat cool systems and water chillers

FRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY

Air Conditioners. Summer

SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

Owner Installation Manual for PROPAC 30/45/70/90/140 M/MY AIR/WATER HEAT PUMPS (SD ISSUE 28) 18/03/11 CONTENTS

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CD35 / CD35P INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Hi - Wall Split Systems 12K - 18K - 24K

Heating in residential pools

Transcription:

CDP 40T SWIMMING POOL DEHUMIDIFIER Function The CDP 40T is an energy efficient and quiet pool dehumidifier. It works in accordance with the condensation principle. A fan draws the humid air into the dehumidifier and through an evaporator coil. When passing through the evaporator the air is cooled down to below its dew point temperature, and its content of water vapour is condensed into water, which falls into the drip tray and then is led from the drip tray to a drain. The cold, dry air is then passed over the condenser coil where it is re-heated, before leaving the unit at a temperature, which is approx. 5 C higher than at the inlet. Applications: Indoor swimming pools, private or hotels Therapy pools Spas Gymnasias FEATURES Dehumidifier Built into a strong and robust powder coated hot galvanized sheet metal cabinet Evaporator and condenser coils are epoxy-coated for high corrosion resistance Fixed to the wall by means of a wall mounting strip supplied with the unit Condensate outlet located at the bottom. Outlet stub can be connected to a ¾ hose Outside connection to mains Control Built in electronic hygrostat and thermostat To establish ideal ambient sensor point (RH/t) the fan(s) run 1 minute each hour Integrated ON/OFF control of humidity and temperature (electric or water heating coils as accessories) 0-VOLT connection for alarm 230 V for control valve, exhaust fan and pump/boiler RS 485 gate for BMS (Modbus) Diodes BLUE: Power connected, standby mode GREEN: Compressor ON, deicing YELLOW: Remote pairing mode RED: Errors Defrosting Active, demand-controlled defrosting is incorporated into the electronic control. Service For easy service the refrigerant circuit is supplied with a service valve. The PCB has a USB gate for history data logging for easy fault finding.

TECHNICAL DATA Model CDP 40T Operating range humidity 40 100% RH Operating range temperature 10 36 C Air volume 400 m 3 /h Power supply 1x230/50 V/Hz Max. ampere consumption 3,8 A Max. power consumption 0,9 kw Refrigerant R407C Quantity of refrigerant 0,7 kg Compressor Rotary Fan Radial Sound level (in pool room 1 m from the wall) 43 db(a) Weight 57,5 kg Filter G3 PPI 15 Colour (Cabinet) RAL 7035 Protection class IPX4 Corrosion protection in accordance with EN/ISO 14-2 C4 CAPACITY CURVES Temp. o C 40 CDP 40T 40% RH 60% RH 80% RH 35 30 25 20 15 10 5 0 0 0,5 1,0 1,5 2,0 2,5 Specific energy consumption (SEC): 0,47 kwh/l at 28 C & 60% RH L/H INSTALLATION CDP 40T, 50T and 70T are designed for installation in an adjacent room and are supplied with a through-the-wall duct kit with supply and return air grills (accessory).

DIMENSIONS CDP 40T CDP 70 998T 1483 Drain outlet position 50,6 430,7 Duct kits CDP 40T c 80 235 73 146 106 CDP 70 T 1483 CDP 50 T 1148 CDP 40 T 998 The duct kit includes an extension for wall thickness from 70 to 366 mm. A B C Wall opening Accessories Wireless remote control DRC1 Water heating coils Control valve for water heating coils Electric heating coils Exhaust fans Through-wall duct kit with filter, extension kit and alu grill Duct lead-in adapter CDP 40T 465 998 642 610 x 110 Linear dimensions without tolerances according to Sheetme DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1 process MATERIAL: THICKNESS: "Thickness This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S. All designs originated by Dantherm Air Handling A/S are the property of said Company and will be protected by Patents. SCALE: NOT TO SCALE All dimensions are in mm.

CDP 50T SWIMMING POOL DEHUMIDIFIER Function The CDP 50T is an energy efficient and quiet pool dehumidifier. It works in accordance with the condensation principle. A fan draws the humid air into the dehumidifier and through an evaporator coil. When passing through the evaporator the air is cooled down to below its dew point temperature, and its content of water vapour is condensed into water, which falls into the drip tray and then is led from the drip tray to a drain. The cold, dry air is then passed over the condenser coil where it is re-heated, before leaving the unit at a temperature, which is approx. 5 C higher than at the inlet. Applications: Indoor swimming pools, private or hotels Therapy pools Spas Gymnasias FEATURES Dehumidifier Built into a strong and robust powder coated hot galvanized sheet metal cabinet Evaporator and condenser coils are epoxy-coated for high corrosion resistance Fixed to the wall by means of a wall mounting strip supplied with the unit Condensate outlet located at the bottom. Outlet stub can be connected to a ¾ hose Outside connection to mains Control Built in electronic hygrostat and thermostat To establish ideal ambient sensor point (RH/t) the fan(s) run 1 minute each hour Integrated ON/OFF control of humidity and temperature (electric or water heating coils as accessories) 0-VOLT connection for alarm 230 V for control valve, exhaust fan and pump/boiler RS 485 gate for BMS (Modbus) Diodes BLUE: Power connected, standby mode GREEN: Compressor ON, deicing YELLOW: Remote pairing mode RED: Errors Defrosting Active, demand-controlled defrosting is incorporated into the electronic control. Service For easy service the refrigerant circuit is supplied with a service valve. The PCB has a USB gate for history data logging for easy fault finding.

TECHNICAL DATA Model CDP 50T Operating range humidity 40 100% RH Operating range temperature 10 36 C Air volume 680 m 3 /h Power supply 1x230/50 V/Hz Max. ampere consumption 6,6 A Max. power consumption 1,5 kw Refrigerant R407C Quantity of refrigerant 0,9 kg Compressor Rotary Fan Radial Sound level (in pool room 1 m from the wall) 44 db(a) Weight 66 kg Filter G3 PPI 15 Colour (Cabinet) RAL 7035 Protection class IPX4 Corrosion protection in accordance with EN/ISO 14-2 C4 CAPACITY CURVES Temp. C 40 35 30 25 20 15 10 5 40% RH CDP 50T 60% RH 80% RH 0 0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 Specific energy consumption (SEC): 0,48 kwh/l at 28 C & 60% RH L/H INSTALLATION CDP 40T, 50T and 70T are designed for installation in an adjacent room and are supplied with a through-the-wall duct kit with supply and return air grills (accessory).

DIMENSIONS CDP 50T CDP 1148 70 T 1483 Drain outlet position 50,6 430,7 Duct kits CDP 50T c 80 235 73 146 106 CDP 70 T 1483 CDP 50 T 1148 CDP 40 T 998 The duct kit includes an extension for wall thickness from 70 to 366 mm. A B C Wall opening Accessories Wireless remote control DRC1 Water heating coils Control valve for water heating coils Electric heating coils Exhaust fans Through-wall duct kit with filter, extension kit and alu grill Duct lead-in adapter CDP 50T 616 1148 791 760 x 110 Linear dimensions without tolerances according to Sheetme DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1 process MATERIAL: THICKNESS: "Thickness This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S. All designs originated by Dantherm Air Handling A/S are the property of said Company and will be protected by Patents. SCALE: NOT TO SCALE All dimensions are in mm.

CDP 70T SWIMMING POOL DEHUMIDIFIER Function The CDP 70T is an energy efficient and quiet pool dehumidifier. It works in accordance with the condensation principle. A fan draws the humid air into the dehumidifier and through an evaporator coil. When passing through the evaporator the air is cooled down to below its dew point temperature, and its content of water vapour is condensed into water, which falls into the drip tray and then is led from the drip tray to a drain. The cold, dry air is then passed over the condenser coil where it is re-heated, before leaving the unit at a temperature, which is approx. 5 C higher than at the inlet. Applications: Indoor swimming pools, private or hotels Therapy pools Spas Gymnasias FEATURES Dehumidifier Built into a strong and robust powder coated hot galvanized sheet metal cabinet Evaporator and condenser coils are epoxy-coated for high corrosion resistance Fixed to the wall by means of a wall mounting strip supplied with the unit Condensate outlet located at the bottom. Outlet stub can be connected to a ¾ hose Outside connection to mains Control Built in electronic hygrostat and thermostat To establish ideal ambient sensor point (RH/t) the fan(s) run 1 minute each hour Integrated ON/OFF control of humidity and temperature (electric or water heating coils as accessories) 0-VOLT connection for alarm 230 V for control valve, exhaust fan and pump/boiler RS 485 gate for BMS (Modbus) Diodes BLUE: Power connected, standby mode GREEN: Compressor ON, deicing YELLOW: Remote pairing mode RED: Errors Defrosting Active, demand-controlled defrosting is incorporated into the electronic control. Service For easy service the refrigerant circuit is supplied with a service valve. The PCB has a USB gate for history data logging for easy fault finding.

TECHNICAL DATA Model CDP 70T Operating range humidity 40 100% RH Operating range temperature 10 36 C Air volume 900 m3/h Power supply 1x230/50 V/Hz Max. ampere consumption 8 A Max. power consumption 1,8 kw Refrigerant R407C Quantity of refrigerant 1,2 kg Compressor Rotary Fan Radial Sound level (in pool room 1 m from the wall) 47 db(a) Weight 77,5 kg Filter G3 PPI 15 Colour (Cabinet) RAL 7035 Protection class IPX4 Corrosion protection in accordance with EN/ISO 14-2 C4 CAPACITY CURVES Temp. C 40 CDP 70T 40% RH 60% RH 80% RH 35 30 25 20 15 10 5 0 0 1 2 3 4 5 6 Specific energy consumption (SEC): 0,43 kwh/l at 28 C & 60% RH L/H INSTALLATION CDP 40T, 50T and 70T are designed for installation in an adjacent room and are supplied with a through-the-wall duct kit with supply and return air grills (accessory).

DIMENSIONS CDP 70T CDP 1483 70 T 1483 Drain outlet position 50,6 430,7 Duct kits CDP 70T c 80 235 73 146 106 CDP 70 T 1483 CDP 50 T 1148 CDP 40 T 998 The duct kit includes an extension for wall thickness from 70 to 366 mm. A B C Wall opening Accessories Wireless remote control DRC1 Water heating coils Control valve for water heating coils Electric heating coils Exhaust fans Through-wall duct kit with filter, extension kit and alu grill Duct lead-in adapter CDP 70T 950 1483 1126 1095 x 110 Linear dimensions without tolerances according to Sheetme DS/EN 22768-1 medium. Angular dimensions without tolerances: ± 1 process MATERIAL: THICKNESS: "Thickness This Drawing is furnished with the understanding that the essence there of will not be reproduced in whole or in part without written authorization by Dantherm Air Handling A/S. All designs originated by Dantherm Air Handling A/S are the property of said Company and will be protected by Patents. SCALE: NOT TO SCALE All dimensions are in mm.