R-GAGE QT50R-AF2W Sensor

Similar documents
R-GAGE QT50R-AF2W Sensor

R-GAGE QT50R-AF2 Sensor

R-GAGE QT50R-AFS Sensor

QT50RAF Radar-Based Sensor

MINI-BEAM Expert Series

R-GAGE Radar Sensor bannerengineering.com.

Door/Window Sensor Installation Instructions

M12 Class 1 Laser Emitter

M12 Class 2 Laser Emitter

Pet Immune SAW PIR Motion Sensor

ShockLink. Important Product Information.

Optima ZigBee Thermostat

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

with motion sensor ITM. / ART Model: LM55811 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY

GARAGE DOOR OPENER KIT

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator

Wireless Outdoor Air Reset Adaptor PN:

PreView Sentry ST82 & ST87 Series Sensor Operating Manual

Automatic Dimming Mirror with HomeLink

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

Quick Start & Setup Guide

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

Compatibility. Contents. Necessary Tools

VX SERIES Wireless Thermostat with Occupancy Sensor

Yale Real Living Key Free Push Button Deadbolt B1 with Installation and Programming Instructions

2 x screws. 2 x wall plugs

PreView Side Defender SDR8503 & SDL8503 System Operating Manual

PreView Side Defender

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

PreView WorkSight. WS6220 WS6215 WS6210 Sensor Operating Manual.

Intelli-Time Alarm Clock model 13041RM

IMPORTANT. 3-in-1 Weather Sensor model SAVE THIS MANUAL FOR FUTURE REFERENCE. Package Contents

Yale Real Living Assure Lock Push Button Deadbolt Installation and Programming Instructions (YRD216)

Smart Home Outdoor Siren

Rev D 3/20/17

with Wi-Fi and local API Quick start and setup guide

Wi-Fi DOOR/WINDOW SENSOR

Nest x Yale Lock Programming/Troubleshooting Guide

Draft - develop and review

WorkZone PreView Sensor Manual

SZ-PIR04N ZigBee Motion Detector Installation Guide

EL-TSTAT Owner s Manual

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

Humidity Monitor model 01080

Limitless Wireless Din-Rail Receiver. WDRR Series. Datasheet

Thermometer model 02059

Contents. User Manual GA-U-1. VultureNet: Long Range System

PET IMMUNE PIR MOTION DETECTOR

Atomic Digital Office Clock

TX3 Series. TX3 InSuite. User Guide

TrueClean ToteCleaner

IMPORTANT. Questions? Contact Customer Support at (877) or visit 5-in-1 PRO+ Weather Sensor model

ADT. Pulse 2017ADT LLC

Universal Wireless Thermostat Kit. * Wireless Humidity Control requires accessory model 7330.

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

LV-S-5. Instruction Manual DIRECT CONTACT STRAY VOLTAGE DETECTOR GENERAL DESCRIPTION HOW IT WORKS

3M Benchtop Air Ionizer 963E. User s Guide

User Guide. Alert. Locate. Respond. A Mobile Worker Safety Device Complementing Loner Mobile. SureSafe Safety Monitoring confirmation light

Wireless Panel-Mount Monitor

Digital Refrigerator/Freezer Thermometer model 00986

Thermometer with Wired Sensor

Ultrasonic Reflective Sensor

IFS Fiber Module Installation & Operation Instructions

IMPORTANT. Display for 5-in-1 Weather Sensor model 06005RM/1010RX SAVE THIS MANUAL FOR FUTURE REFERENCE. Package Contents

Yale Real Living Push Button Deadbolt Installation and Programming Instructions (YRD210)

Caught a critter in the act?

Room Monitor SAVE THIS MANUAL FOR FUTURE REFERENCE.

DEHUMIDIFIER. User Manual 50BT, 70BT

IFS Fiber Module Installation & Operation Instructions

Wireless External Alarm

INTRODUCTION. Industry Canada: Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee)

Yale Real Living Push Button Lever Installation and Programming Instructions (YRL210)

INSTALLATION INSTRUCTIONS for PULSAR NS-Series Nav/Position or Nav/Position/Strobe Lights

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

TrueClean ToteCleaner

Installation Instructions

Immunity. P/N: ver.b

User s Guide Wireless Doorbell for IWATCHALARM (Add-On) Model: SM-105DB

Smoke Bridge Owner s Manual

RK-05 Carbon Monoxide Detector Operator s Manual

Remote Relay Module (RRM)

CLIP PG2 PowerG Wireless, Curtain, PIR Motion Detector

User s Guide Home Automation Wall Socket for IWATCHALARM (Add-On) Model: SM-001SK

INSTRUCTION MANUAL P Heating and 1 Cooling

IFS Fiber Module Installation & Operation Instructions

THB4002. GoTemp Food Infrared Thermometer With Laser Sighting And Thermocouple Jack User Guide. Measuring Temperature The Smart Way.

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

Smart Hub THERMOSTAT. Installation Manual

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

CD6102 / CD6102 OC / CD6102-2

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

EcoView Thermostat. Product Description. Installation. Product Number. Caution Notations. Required Tools. Expected Installation Time.

Long-Range Barrier Sensors

Thermometer with Probe model 00891A

Transcription:

Datasheet Radar-Based Dual-Zone Narrow-Beam Sensors for Detection of Moving and Stationary Targets Fourth generation FMCW (true-presence) radar detects moving and stationary objects Narrow beam pattern Two independent, adjustable sensing zones Easy setup and configuration of range, sensitivity, and output with simple DIP switches Sensing functions are unaffected by wind, falling rain or snow, fog, humidity, air temperatures, or light Sensor operates in Industrial, Scientific, and Medical (ISM) telecommunication band Rugged IP67 housing withstands harsh environments Protected by US patents CAUTION: Make No Modifications to this Product Any modifications to this product not expressly approved by Banner Engineering could void the user's authority to operate the product. Contact Banner Engineering for more information. WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Models Models Maximum Range Connection Supply Voltage Telecom Approval 2 Output QT50R-US-AF2W QT50R-EU-AF2W QT50R-KR-AF2W 2 m (78 ft) 5-wire 2 m (6.5 ft) Integral cable 2 to 0 V dc 2 to 2 V dc Telecom approved for US, Canada and Brazil Telecom approved for Europe, UK, Australia, New Zealand, China, and Japan Telecom approved for South Korea DIP-switchselectable NPN or PNP and N.O. or N.C. QT50R-TW-AF2W 2 to 0 V dc Telecom approved for Taiwan Cabled models only are listed. For integral 5-pin Euro-style (M2) quick-disconnect fitting, add suffix "Q" to the model number (for example, QT50R-xx-AF2WQ). QD models require a mating cordset; see Quick Disconnect (QD) Cordsets on page 6. 2 For additional countries, contact Banner Engineering. Original Document 6260 Rev. F 7 August 206 6260

Overview The R-GAGE sensor emits a well-defined beam of high-frequency radio waves from an internal antenna. Some of this emitted energy is reflected back to the receiving antenna. Signal processing electronics determine the distance from the sensor to the object based on the time delay of the return signal. The sensor can be configured to two independent sensing zones. The two sensing zones are factory pre-set to default distances; they can be reconfigured for different distances using the DIP switches on the back of the sensor. The sensor is plug-in ready for immediate operation. The sensitivity was precalibrated at the factory, assuming that the sensing field will be clear of obstacles. The sensitivity can be adjusted using the DIP switches on the back of the sensor. Figure. R-GAGE features D Zone Zone 2 X Y A Figure 2. R-GAGE setpoint distances B. Power LED: Green (power ON) 2. Signal Strength LED: Red (flashes in proportion to the signal strength). Output LEDs: Yellow (output energized); Red (configuration) Access the DIP switches behind the threaded cap on the sensor back (not shown) EU, KR Models TW, US Models X Minimum Zone setpoint distance m (9.8 ft).5 m (.5 ft) Y Maximum Zone setpoint distance 2 m (9. ft) 2 m (9. ft) A Minimum Zone 2 setpoint distance 8 (26.2 ft) 8 (26.2 ft) B Maximum Zone 2 setpoint distance 2 (78.7 ft) 2 (78.7 ft) D Dead Zone Sensor Configuration The sensing zone distance, sensitivity, and output configuration can be selected via the DIP switches on the back of the sensor. Use the included spanner to open the screw-off cover on the back of the sensor and access the DIP switches. Important: Tighten the DIP switch cover a full quarter turn after contact to maintain the watertight seal. DIP Switch Functions Switch Function, 2, Zone and Zone 2 distance pairs, 5 Sensitivity 6 Dual NPN/PNP output functionality 7 Normally Open/Normally Closed output functionality 8 Response Speed DIP switch is on the left and DIP switch 8 is on the right. Typical dead zone: 0. m (. ft) for moving and.0 m (. ft) for stationary targets, but varies with target reflectivity. 2 www.bannerengineering.com - Tel: +-76-5-6 P/N 6260 Rev. F

Distance Settings Switch Switch 2 Switch EU, KR Models TW, US Models All Zone Zone Zone 2 0 0 0 m (9.8 ft).5 m (.5 ft) 8 m (26.2 ft) 0 0 m (. ft) m (. ft) 0 m (2.8 ft) 0 0 6 m (9.7 ft) 6 m (9.7 ft) 2 m (9. ft) 0 8 m (26.2 ft) 8 m (26.2 ft) 6 m (52.5 ft) * 0* 0* 8 m (26.2 ft) 8 m (26.2 ft) 20 m (65.6 ft) 0 0 m (2.8 ft) 0 m (2.8 ft) 20 m (65.6 ft) 0 0 m (2.8 ft) 0 m (2.8 ft) 2 m (78.7 ft) 2 m (9. ft) 2 m (9. ft) 2 m (78.7 ft) NOTE: Highest sensitivity is achieved only if sensing distance is 8 m (26.2 ft) or less Sensitivity Selection Switch Switch 5 Sensitivity 0* 0* (Highest) 0 (High) 0 2 (Medium) (Low) Output Configuration Switch 6 NPN / PNP Switch 7 NO / NC 0* NPN PNP 0* NO NC Response Speed Switch 8 On Total Off Total Total 0 0 70 00 * 50 00 50 P/N 6260 Rev. F www.bannerengineering.com - Tel: +-76-5-6

Specifications Range The sensor is able to detect a proper object (see Detectable Objects) from to 2 m (. to 78.7 ft), depending on target Detectable Objects Objects containing metal, water, or similar high-dielectric materials Operating Principle Frequency modulated continuous-wave (FMCW) radar Operating Frequency US, TW Models: 2.075 2.75 GHz, ISM Band EU, KR Models: 2.050 2.250 GHz, ISM Band Supply Voltage 2 to 0 V dc, less than 00 ma, exclusive of load For KR models: 2 to 2 V dc, less than 00 ma exclusive of load Supply Protection Circuitry Protected against reverse polarity and transient overvoltages Delay at Power-up Less than 2 seconds Output Configuration DIP switch 6 selects dual NPN (default) or dual PNP operation; DIP switch 7 selects N.O. (default) or N.C. operation; 50mA each Zone output: white wire Zone 2 output: black wire Output Protection Protected against short circuit conditions Response Time DIP switch 8 selects ON/OFF response time IndicatorsInicators Power LED: Green (power ON) Signal Strength LED: Red, flashes in proportion to signal strength. Steady on at x excess gain. Only indicates signal amplitude, not target distance. Output LEDs: Yellow (output energized) / Red (configuration) See Figure on page 2 Adjustments DIP-switch-configurable sensing distance, sensitivity, response time, and output configuration Construction Housing: ABS/polycarbonate Lightpipes: Acrylic Access Cap: Polyester Operating Temperature 0 C to +65 C ( 0 F to +9 F) Environmental Rating IEC IP67 Connections Integral 5-wire 2 m (6.5 ft) cable or M2 Euro-style QD fitting. QD models require a mating cordset Certifications ETSI/EN 00 0 FCC part 5 RSS-20 ANATEL Category II CMIIT Category G ARIB STD T-7 KC mark - MSIP/RRA NCC for others, contact Banner Engineering Country of Origin: USA FCC ID: UEQT50RUS This device complies with Part 5 of the FCC Rules. Operation is subject to the following two conditions: () this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. IC: 70A-QR50RCA This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: () this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme aux CNR exempts de licence d'industrie Canada. Son fonctionnement est soumis aux deux conditions suivantes:() Ce dispositif ne peut causer des interférences; et(2) Ce dispositif doit accepter toute interférence, y compris les interférences qui peuvent entraîner un mauvais fonctionnement de l'appareil. Este equipamento opera em caráter secundário, isto é, não tem direito à proteção contra interferência prejudicial, mesmo de estações do mesmo tipo e não pode causar interferência a sistemas operando em caráter primário. SRD2-IOB200.2TR0. South Korea Class A Certification A 급기기 ( 업무용방송통신기자재 ) 이기기는업무용 (A 급 ) 으로전자파적합기기로서판매자또는사용자는이점을주의하시기바라며, 가정외의지역에서사용하는것을목적으로합니다. www.bannerengineering.com - Tel: +-76-5-6 P/N 6260 Rev. F

Dimensions 259 mm 0.2" 208 mm 8.2" mm.6" mm 0." 20 mm.7" 05 mm." Ø68 mm 2.7" 89 mm.5" 66 mm 2.6" 5 mm 2." X Ø5 mm 0.2" 2 mm 0.9" Beam Pattern Typical Beam Pattern (with BRTR-CC20E Radar Target, Radar Cross Section = 50 m 2 ) 0 m Left-Right Beam Pattern Typical Beam Pattern (with different targets) at highest sensitivity level 0 m Left-Right Beam Pattern 5 m Sensitivity 5 m Sensitivity 0 2 0 2-5 m -5 m -0 m 0 5 m 0 m 5 m 20 m 25 m -0 m 0 5 m 0 m 5 m 20 m 25 m Distance Distance : Indicates sensitivity level : Weak Object (Radar cross section = 0.25 m 2 ) 2: Car (Radar cross section = m 2 ) : Large Truck (Radar cross section = 50 m 2 ) : Passenger Train (Radar cross section = 00 m 2 ) NOTE: The effective beam pattern depends on the sensitivity level and target properties. Windows The R-GAGE sensor can be placed behind a glass or a plastic window, but the configuration must be tested and the distance from the sensor to the window must be determined and controlled prior to installation. There is typically a 20% signal reduction when the sensor is placed behind a window. P/N 6260 Rev. F www.bannerengineering.com - Tel: +-76-5-6 5

Polycarbonate at mm thickness performs well in most situations, but the performance depends on filler materials. Thinner ( to mm) windows have high reflection. The amount of reflection depends on the material, thickness, and distance from the sensor to the window. Locate the sensor in a position of minimum reflection from the window, which will repeat every 6. mm of distance between the sensor and the window. The positions of maximum reflection from the window repeat between the minimums, and decrease in effect until the window is approximately 50 mm (5.9 in) away. Consult the factory for pre-tested window materials which can be used at any distance without issue. Additionally, the face of the window should be protected from flowing water and ice by use of a flow diverter or hood directly above the window. Falling rain or snow in the air in front of the window, light water mist, or small beads on the face of the window are typically not an issue. However, a thick, continuous surface of water or ice directly on the face of the window can be detected as a dielectric boundary. Weather The R-GAGE sensor can be used in the extreme weather conditions found in port harbors and near oceans. The water in the air does not affect the radar beam, but thick water or ice on the face of the radome can affect performance. In heavy rain or ice conditions, to prevent build-up of water or ice on the radome, use the SAQT50R-96 accessory. This is a hydrophobic end cap that is easily attached over the sensor radome. This end cap, which is field-replaceable, will take the regular wear and tear from port operation to protect the sensor radome and prolong the life of the radar sensor. Wiring Wiring Key: 2 5 Load Load 2 shield (QD cordset) + 2-0V dc = Brown 2 = White = Blue = Black 5 = Gray (Do not connect NOTE: Banner recommends that the shield wire (quick disconnect (QD) fitting cordsets only) be connected to earth ground or dc common. Shielded cordsets are recommended for all QD models. Accessories Quick Disconnect (QD) Cordsets 5-Pin Threaded M2/Euro-Style Cordsets with Shield Model Length Style Dimensions Pinout (Female) MQDEC2-506 MQDEC2-55.8 m (6 ft).57 m (5 ft) Typ. MQDEC2-50 MQDEC2-550 MQDEC2-506RA MQDEC2-55RA MQDEC2-50RA 9. m (0 ft) 5.2 m (50 ft).8 m (6 ft).57 m (5 ft) 9. m (0 ft) Straight Right-Angle 2 Typ. [.26"] M2 x 2 ø.5 5 0 Typ. [.8"] = Brown 2 = White = Blue = Black 5 = Gray MQDEC2-550RA 5.2 m (50 ft) M2 x ø.5 [0.57"] 6 www.bannerengineering.com - Tel: +-76-5-6 P/N 6260 Rev. F

NOTE: Pin 5 is not used. Mounting Brackets All measurements are in mm SMB0SC Swivel bracket with 0 mm mounting hole for sensor Black reinforced thermoplastic polyester Stainless steel mounting and swivel locking hardware included 58 29 67 A B SMB0MM 2-ga. stainless steel bracket with curved mounting slots for versatile orientation Clearance for M6 (¼ in) hardware Mounting hole for 0 mm sensor 57 70 A B C 57 Hole center spacing: A=ø 50.8 Hole size: A=ø 7.0, B=ø 0.0 Hole center spacing: A = 5, A to B = 25. Hole size: A = 2.6 x 7, B = ø 6., C = ø 0. Weather Deflector SAQT50R Coated to help repel water and maximize signal strength Mounts using screws for easy application and replacement Required if the R-GAGE is exposed to rain or snow Prevents buildup of water or ice interfering with sensor performance x -0 UNC 76.2 mm 0.5 mm 27.5 mm Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. For the most recent version of any documentation, refer to: www.bannerengineering.com. Banner Engineering Corp. All rights reserved