AWE Manhole size 500mm - mounted at pharmaceutical vessel

Similar documents
Hakki Pilke Raven spare parts manual

High Pressure Manways CODAP 2000 & PED 96/23/CE

SPARE PARTS LIST - VTA 6S - 400V 50Hz 3~ Version 2.1

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Sheet Ref. CSCONTENTS May Revision 0

ENRGY CURB APPLICATION GUIDE FOR TPO ROOFING SYSTEMS

Power sweeper 2+2. Operating instructions

FRAME AND CONSOLE PARTS

FOF INDUSTRIAL SATURATED STEAM STERILIZERS

Deluxe Welding Tool Chest

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

FAN ENGINEERING. Sealing of Fan Housings

CONDITIONS OF SALE AND WARRANTY

Standard Parts in Hygienic Design

150T Electric Shop Press

ZETA MAGNETIC AGITATORS

Illus. Part No. No. DESCRIPTION

High pressure cleaning heads cleanliness all around

Drain Cleaning Machine K-39

4-1 1 / 2 " Tees / 2 " hole saw w/ 1/4" drill bit / 2 " Male slip plugs

STONE TROUGH CONSOLE SINK

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

CM24T, CM24P Coffee Systems

VIBRA SCHULTHEIS. Vibrating Spiral Conveyors.

ASEPTIC SAMPLING VALVES SANITARY SAMPLING VALVES SANITARY SAMPLING BOTTLE TANK BOTTOM ASEPTIC VALVE

Quality Heat Exchangers

Operating Instructions

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

Remote Water Quality System Standard Equipment (supplied by EPI) Remote Water Quality System Optional Equipment (supplied by EPI)

STOURFLEX. Technically Advanced Flexible Solutions. A Guide to the Selection of STOURFLEX Pump Connectors

SC250X FLOOR GRINDER OPERATIONS MANUAL

50 Disassembly and assembly Cab and its attachments

Operating instructions

Operating Instructions

Centurion Society of Model Engineers. Boiler Handbook

JUST FOR CIP CLEANING

We think the lines DD...and TDA.. can do this job to satisfy your customers And your workshop.

TS-49 PART # DPEC DATE: REVISED:

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

Operating Instructions. Boilermag XL Filter. High Intensity Magnetic Separator

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

REVERSING DRUM MIXER

CEN/TC 33 - Doors, windows, shutters, building hardware and curtain walling. EN 107:1980 Methods of testing windows - Mechanical test 89/106/EEC

Hydrotherapy Jets (Remote Water Quality System)

MODEL 4246 MIXER-GRINDER

Cameo White January (first two digits indicate the month of expiration, 01 12)

hygienic design CLEANLINESS MADE TO MEASURE: HYGIENIC DESIGN FANS

OWNERS INSTRUCTION MANUAL

Oil burners fuel unit with solenoid valve

MEGABAND MICA INSULATED BAND HEATERS

TECHNICAL INSTRUCTIONS FOR AFTER SALES ULTRA ELECTRIC PASTA COOKER

Curb Inlet Filter INSTALLATION MANUAL. Bio Clean Environmental Services, Inc. 398 Via El Centro Oceanside, CA 92058

OPERATING MANUAL CDP 115 Peltier cooling unit for waterbaths

Motor/Frame Assembly. Drain Cleaning Machine K Position Fan as Shown. Fan Mounting Detail

UNDERCOUNTER DISHWASHER

Liquid Samplers. Powders. Tel: +44 (0)

Smoke extraction duct of sheet steel

The plant meets the requirements of the current FSS 5 Checklist for Vessel Process Plants

Ampco s Complete Line of AC SERIES PUMPS AC, AC+, IC+

Centrometal d.o.o. - Glavna 12, Macinec, Hrvatska, tel: , fax: THE BOILER PelTec 12 WITH SPARE PARTS LIST

Frontier. Self Contained Carpet Extractor. Operator and Parts Manual. Model No.: Rev. 00 (09-99)

FRAME AND CONSOLE PARTS

COMPONENT SOLUTIONS for the lighting industry

Installation, Operation and Maintenance Instructions Electric Flow Heater OM009

Quality Heat Exchangers

OPERATING MANUAL. BAK Thermoplastic Welding Technology AG 1

An ibuy Stores Company

Flow Control for Fire Protection

Tumbler Screening Machines TSM / tsi. Maximum screening quality for fine and ultra-fine products

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

P-60 and 60 Special. Popcorn Machine Instruction Manual Model #1866, #2085, #2086 and #2656. Cincinnati, OH USA

MSMCR. Counter-Rotating Blenders. I Application. I Principle of operation

DIN /DIN Aseptic Flange Union for ISO 1127 Schedule Pipe

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

TW Compact Accessoires-Carpet tool, 2-nozzles. As at: 01/18/10 Time:18:16

F-P, F-L, FT-P AND FT-L SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL

Exploded View - Model J-7020M/J-7040M Miter Cut-off Saw Base

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

NEOTeCHA Reactor Sampling Type PV

WASHER/DRYER CONTROL PANEL PARTS

Part 2: Installation Instructions cl

IntaKlean Installation & Servicing Instructions IKMF22 and IKMF28

kemutec MIXERS AND BLENDERS kemutec POWDER MIXING TECHNOLGOY FOR THE FOOD, PHARMACEUTICAL AND CHEMICAL INDUSTRIES

MARK-COSTELLO WASTE STERILIZER SPECIFICATION SHEET

Part 3: Service manual, class

BAGI - MIXER. Magnetically Driven Bottom Mounted Mixers. Sealless ZERO LEAKAGE Design. CIP / SIP Capable. Non Contaminating Mixing

pushing the tube into the rear of the water outlet housing with a slight twisting motion to evenly distribute the adhesive. After cleaning off any ext

AUTOMATIC WASHER MODELS: 7MMVWC100DW1 (White) 02/26/ Maytag Part No. W Rev. B

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Zehnder ZIP Radiant Ceiling Panels

MC MC MC MC MC833130

ZETA Magnetic Agitators. For sterile liquid processing.

LP30 High Integrity Low Level Alarm Probe Installation and Maintenance Instructions

PARTS MANUAL. Standard Nagel M2 Bookletmaker

Mechanical seals external, single or double, to DIN EN 12756

TECHNICAL DATA. Wet 26a. February 22, 2009

Summary of Chapters NFPA 1911: Standard for the Inspection, Maintenance, Testing, and Retirement of In- Service Automotive Fire Apparatus

Guide book ASPIMAX 32. Im Geer 20, Isselburg. Type No.: 403. Serial No.:...

CR A-F-A-E-HQQE 3x400/ HZ

Transcription:

AWE MANHOLE Central fast locking device Acc. AD - 2000/H5 and AWE Standards AWE - GmbH D - 87600 Kaufbeuren Am Riederloh 8 Tel: +49 (0) 8341-96400; FAX: +49 (0) 8341-964040 Central Fast Locking devises (Manholes) serve the purpose of work facilitation by rational technique, that enables a rapid and safe opening and locking of vessel inlets and outlets. AWE Manhole size 500mm - mounted at pharmaceutical vessel Although the construction has been well-tried and time-tested, it has been continuously improved by AWE. This has resulted in diverse variants as to size, pressure rating and connecting facilities. The designs range from carbon-steel to stainless-(austenit)-steel in standard, as well as sterile or pharmaceutical quality. Ordinarily our devices are operated by hand, there are, however, also automatically functioning AWE Manholes available. Every Manhole supplied by AWE is tested and checked by german TÜV (Technischer Überwachungsverein = Association for Technical Inspection)

Safety facilities of the hand-operated AWE Manhole fixed cover but not fully opened In contrast to traditional manholes with separately functioning locking elements, the hand-operated AWE-Manhole has a centrally functioning adjustable locking lever, which enables shorter opening and locking times. Consequently, it falls into the category of manholes according to German standard AD 2000 Memorandum A 5. Cover stopped by hydraulic system The individual components are mechanically tooled at the power transmission points and guarantee a constant distribution of loaddispatching based on the tolerances provided. The cover is evenly pressed on the sealing by the ball-bearing suspension of the locking lever. A plane assembly between cover, sealing and locking-ring is also ensured by the adjustable, slightly elastic bearing in the hinge. The insertion of all lock levers can be visually checked, since there is a sufficient distance between locking-ring and lidcovering. The insertion depth of all lock levels can Closed AWE - Manhole additionally be checked by means of a visual indication. In a closed position this may measure a maximum of two millimetres. The milling-machine-cut edges of the locking lever effect an additional centring of the cover in the locking-ring. On the outside there is a final switch which meets the requirements of VDE 0116 and is set off by a locking lever when it reaches the final position OFF.

As long as the locking position is not reached, the process operation must not be started or a pressure build-up commenced. Safety Precaution against Opening under Pressure. Pressure warning device (electrically operated) After release by the facilities triggered off by the internal pressure an electrical-magnet, the star-shaped handle then is set off in the opening direction (i.e. anticlockwise) Pressure warning device (by means of a ball-switch) By means of a hand-operated ball-switch whose operational lever reaches into the stars-shaped handle of the locking device. Before setting the Manhole into motion it must be checked whether the pressure vessel is under no pressure. The ball-switch can only be operated in the open position of the star switch. The electrical warning system Opening and Locking procedure The locking levers of the Manhole are shaped in such a way that in the process of opening the cover is moved 2 millimetres from the locking ring and thus causes a pressure adjustment. This aperture is created by about two turns of the Manhole and by a probably existing remaining pressure.

Operational stages of opening and locking During the first turning the locking level remains completely inside insertion device, only the adhesion power of the cover is reduced. The next two turns cause a total power relief, but still prevent the lid from being removable. Only some further turns withdraw the locking lever completely. The locking procedure takes place in a reverse order. The adhesive pressure necessary for making the device air-tight can be set infinitely variable. The necessary locking power is minimal. Catching device (Optional). (Prevents the cover from being ejected by a probably remaining pressure) Function: If in the process of opening the Central Locking the cover is pressed in the opening direction, the catching device engages in the locking ring. Even if the locking devices are no longer in the insertion position the catching device prevents the cover from striking against something. Only when after the release of the remaining pressure the cover rests on the washer by its own weight the catching device is released by turning the star-shaped handle twice to the right. Thus the latches of the catching device are debarred; the stars-shaped handle must be turned left and the opening process is finished.

Return Flow Prevention (Optional) Prevents the handling of the star-handle if there is a remaining pressure of more than 0,2 bar. Function: A diaphragm presses a saw tooth axle in the opposite saw-teeth of the thread screw (in the presence of remaining pressure). The axle is connected with the central nut by a square-headed bolt and is thus prevented from turning in the opening direction. The turning in the locking direction, however, is possible by means of the saw-teeth. Only if the remaining pressure is lower than 0,2 bar, a spring releases the engagement of the teeth. Safety Precaution of the automatically operating AWE Manhole (Optional) In case of the automatically functioning AWE Manhole the central nut is run by an electric power source. It must be safeguarded by at least two devices steered by the internal pressure that the pressure balance with the atmosphere has been achieved. After the release of the devices steered by the internal pressure the operation of an electrical-magnet (that operates without electricity) effects the central nut. After that the electric motion of the Central Locking takes place. Switching off in the position ON by means of the position switch. In the position OFF by means of the adjustable torsion switch. The cover is opened by a pneumatic power source. The process of locking In the process of locking the final position is controlled by the end switch which is placed outside and operated by a locking lever in the position OFF. As long as the locking position is not indicated the process steering must not be put into operation or the pressure build-up set in motion. Standard Mode Material and material evidence. Pressure bearing components of the Manhole (cover, locking ring, thread screw, locking lever, case, flange and thread screw nut) are made of austenit materials according to standard industrial norm regulation 17440. Evidence of the quality characteristics according to german standard AD W 2 Table 2 Sealing Round cord 8 millimetres optionally geared to the pertinent medium, made of silicon rubber, Viton, Perbunan, PTFE and PTFE-coated. Special sealing by the company GDF Sealing reference 6 N / mm

welding data Welding components meant or pressure bearing parts are guaranteed weldable. Welding procedure, additional materials and heat-treatment are geared to the raw material and component geometry employed. Special surface treatment are dealt with in accordance with customer specifications. (Glasbead-blasting, dipping and grinding.) Checking procedure Welder test: in accordance with DIN 8560 / EN 287. Procedure test: in accordance with AD-2000 HP / EN 288. Weld joint factor: 0,85 Length welds: Round seams and others : Stubs: Delivery regulations: X-ray or fluoroscopic examination of 2% of the weld. to be checked along with the length seams. spot checking of dye-colour penetration testing. according to pressure vessel regulations. Instructions Taking-over and Acceptance test: According to AD-2000 Memorandum A5, TRB 402, TRB 404 Putting into operation: Only in line with assembly instructions. Maintenance a) Abration limit for the thread screw nut in an axial direction: 1 mm b) Abration limit for ball suspension of the locking lever in all directions: 1 mm c) Aperture between the locking ring and the locking lever in the position OFF : maximal 2 mm d) Cover hinge spring check for cracks. If the spring breaks, there is an increased danger of an accident, because the locking will strike unbraked. Repairs Should only be performed by trained specialists. If the present information (descriptions and drawings) should prove to be insufficient, please phone our Service Department who will be delighted to assist you.