AX51 with Munters Drive

Similar documents
Motor Kit for SW Shutter. Instruction Manual. Motor Kit for SW Shutter. Models: FA2685. Munters Corporation, November 2013 QM1017r6

Flatsided Discharge Cone Models: 54GC & 54GCX

BA2702-P Linear Actuator

RC Series Discharge Cones

FM Munters Drive. Instruction Manual. Munters Drive * Motor Replacement Kit. Motor Replacement Kit for AX and VX Fans

BA4000 Series Curtain Machine

MD Munters Drive. Instruction Manual. Munters Drive * Motor and Controller Replacement Kit. Motor & Controller Replacement kit for AX and VX Fans

BI28SP Ceiling Inlet. Instruction Manual. BI28SP Ceiling Inlet. Bi-Flow, Spring Actuated. Models: BI28SP BI28SP-01

IA Inlet Actuator. Instruction Manual. IA Inlet Actuator Models: IA0090 IA0090P. Munters Corporation, March 2017 QM1235r1

VX51 and VX55 with Munters Drive 51 and 55 Exhaust Fan

14" - 24" CLASSIC Direct Drive Fans

WDP. Installation manual WDP. Gutter system. Ag/MIT/UmEN /14 rev 1.0

AIR HEATING PRODUCTS

MFS. Manual for use and maintenance. + CE Declaration of conformity MFS. Air circulation fan. Models: MFS36 - MFS52. Ag/MIT/UmGB /13 rev1.

Manual for use and maintenance. + CE Declaration of conformity. TU600 - TU800 Chimney fan. Ag/MIT/UmGB /14 rev 1.0

M I S T E L I M I N AT I O N. Mist elimination in Flue Gas Desulphurization. The buck stops here.

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

36 & 48 E-Z Cone Fan. Installation & Operator s Instruction Manual (Direct Drive)

Installation Manual Universal Side-of-Pole Mount UNI-SP/02A

Positive Pressure Filtered Swine Facilities

STT 3000 Series STT250 /150 Surge Protection Device Specifications

Installation Manual Universal Side-of-Pole Mount UNI-SP/01A

JAZ. Operator s Manual. Diesel/Kerosene Air Heaters JAZ 42 JAZ 80 JAZ 80 W JAZ 125 JAZ 160

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

High performing temporary space heaters

Evaporative Humidifier/Cooler FA6 for AHU s Technical manual FA6. HC/MMA/TGB /10 pdf SOS ReklamStudio

Beckhoff short profile

Press Release. Short profile Beckhoff. Short profile February 2009 Page 1 of 6

Pole Mounting System Installation & Certification Manual

Type 2 safety light curtain Type 2 according to the IEC/EN parts 1 and 2 Compact profile: 31 x 32 mm 30 mm resolution for hand detection Wide r

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USING & INSTALLING THE FIXED SOLAR PANEL KIT.

Installation Manual Universal Top-of-Pole Mount UNI-TP/02

High vacuum guide FOR PRE-SEPARATORS AND CYCLONES

MTC-Series Manual Trash Compactors Instruction Manual

NOTICE: The information contained on the following page(s) was produced prior to May 1, On that date Reznor became part of Nortek, Inc.

DESCRIPTION FEATURES WARNINGS APPLICATIONS

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

FieldLink Cable solutions for Automation & Drives

24 & 30 Quiet Design Oscillating Wall Mount Fan

92 RAILWAY ST. SEAFORTH, ONTARIO CANADA, N0K 1W0 TEL: ABSOLUTE AIR INSTALLATION MANUAL

Leading manufacturer of high-end ball valves and pneumatic actuators. Over 60 years experience with industrial applications

Waterpik Water Flosser Model WF-02

Contents. Introduction. Introduction About This Report 1. Sustainability & Strategy. Social Respect for Human Rights and Diversity 15

Model CAC 500M Media Air Cleaner

Compressor Kit for ToughTek F340e Fireproofing Pump

Calaer Marine add-on kit manual. 2kW Calaer air heater 4kW Calaer air heater

Oahu Showerspa Model #1035 Owner's Manual

Operating Instructions & Parts Manual Models 99533, 99532

Accuracy counts! Sensors with analog output

THE VALOR CEILING FAN INSTALLATION INSTRUCTIONS

Shredders from Metso. Lindemann Eta Shred

THE GUSTO CEILING FAN INSTALLATION INSTRUCTIONS

WAIMEA. Waimea Showerspa Model #1034 Owner's Manual

Installation Manual Universal Top-of-Pole Mount UNI-TP/08LL

20-GALLON MOBILE PARTS WASHER OWNER S MANUAL

48 Vanguard Belt Drive Fans Installation and Operators Instruction Manual

Sound Cover [ , , , ]

EcoBrite Smooth Light LED Light Fixtures

Pole Mounting System Installation & Certification Manual

WAV-26 UPRIGHT WIDE AREA VACUUM

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

ELECTRIC RADIANT OUTDOOR / INDOOR HEATER

A WMIA Partner of the Year Winner S-Series Enclosureless Dust Collector

Pole Mounting System Installation & Certification Manual

Installation Instructions

Hustler Z Bac Vac Parts Manual ,

THE CHATEAUX 52"/60" UNI PACK CEILING FAN INSTALLATION INSTRUCTIONS

3MAVR60XX Series Fan. Owner s Guide and Installation Manual. UL Model NO. : 3MAVR60XX

391 WEST WATER STREET TAUNTON, MA P: F:

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

Juna Ceiling Fan JU54. Installation Instructions Instrucciones de instalación Instructions d installation

THE CAPRI III CEILING FAN INSTALLATION INSTRUCTIONS

COMPANY INTRODUCTION

IMPORTANT SAFETY INFORMATION

THE ALTON CEILING FAN INSTALLATION INSTRUCTIONS

Crushers from Metso Recycling. Metso EtaCrush

Installation, Operation and Maintenance Instructions

OneWireless Gauge Reader WGR400 Series Specifications 34-XY July 2009

BFD Light Curtains The new choice for cutting edge safety for industrial doors

Waimea ShowerSpa MODEL #1034

SPECIFICATIONS FEATURES

Pole Mounting System Installation & Certification Manual

The Extraordinaire OWNER S MANUAL. Orbital Ceiling Fan. Model No. OF110** READ AND SAVE THESE INSTRUCTIONS. Net Weight 14.5 lbs. or 6.59 kg.

Installation and Operating Instructions for Microlene Underbench System

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

FOR ENGCON STONE AND SCRAP HANDLING GRAB SK05ST-SK30ST THE WIDEST RANGE ON THE MARKET

Installation Instructions

Air Storm Fans. Air Storm 24 Fiberglass Fan Installation and Operation Manual

Drum Carrier. Operating Instructions and Parts Manual 21VG4 8 DESCRIPTION 21VG48. Allows 1 person to lift, transport, tilt, rotate, and drain

MVX 2000 Multivariable Pressure Transducer. Specifications 34-SM March Introduction. Proven Sensor Technology. Flow Computer Benefits

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

THE GEORGIA PATIO CEILING FAN INSTALLATION INSTRUCTIONS

HEAVY-DUTY WELDING CART USER S MANUAL

MNEFDD54 & MNBCDD54 GALVANIZED WALL FANS Installation, Operation, and Maintenance Instructions

18 INCHES, OSCILLATING STAND FAN

THE COLTON CEILING FAN INSTALLATION INSTRUCTIONS

PTG, SWT Series. Heat Recovery Systems

Transcription:

Instruction Manual AX51 with Munters Drive Fan Hanger Kit AX Hanger Kit and I Beam hardware AX51 with Munters Drive Fan Hanger Kit Models: FH1712 AX Hanger Kit AX51with Munters Drive Fan Munters Corporation, August 2013 QM1248

AX51 with Munters Drive Fan Hanger Kit Manual for use and Maintenance Thank You: Thank you for purchasing a Munters AX51 with Munters Drive fan Hanger Kit. Munters equipment is designed to be the highest performing, highest quality equipment you can buy. With the proper installation and maintenance it will provide many years of service. Please Note: To achieve maximum performance and insure long life from your Munters product it is essential that it be installed and maintained properly. Please read all instructions carefully before beginning installation. Warranty: For Warranty claims information see the Warranty Claims and Return Policy form QM1021 available from the Munters Corporation office at 1-800-227-2376 or by e-mail at aghort.info@munters.com. Conditions and Limitations: Products and Systems involved in a warranty claim under the Warranty Claims and Return Policy shall have been properly installed, maintained and operated under competent supervision, according to the instructions provided by Munters Corporation. Malfunction or failure resulting from misuse, abuse, negligence, alteration, accident or lack of proper installation or maintenance shall not be considered a defect under the Warranty. 2 QM1248 Munters Corporation, August 2013

Index Chapters Page 1. Unpacking the Equipment 4 1.1 Parts List 1.2 Fan Dimensions 2. Instalation Instructions 6 2.1 Install 2.2 Beam Mounting 2.3 Wood Post Mounting 2.4 Round Post Mounting 3. Exploded View 11 Munters Corporation, August 2013 QM1248 3

Unpacking the Equipment 1. 1.1 Parts List Each FH1712 includes: 1 Fan Pipe Hanger 2 Fan Hanger Brackets 1 Mounting Plate 1 Pipe Retainer 2 Pipe Clamps 1 Hardware package as follows HP1134 Hardware package [A]...4 ⅜"-16 x 1.5" Carriage Bolt, ZP [B]...20 ⅜" Flat Washers, ZP [C]...12 ⅜"-16 Nylock Nuts, ZP [D]...4 ⅜"-16 x 2.25" Hex Bolts, ZP [E]...4 ⅜"-16 x 3" Hex Bolts, ZP FA1662 Optional Kit for 'I' beam mounting [F]...4 ⅜" 'I' Beam Clamps, Carbon Steel [G]...4 ⅜ x 1¾ Set Screw [H]...4 ⅜ Flat Washers, SS [J]...4 ⅜" Split Lock Washers, ZP [K]...4 ⅜"-16 Hex Nuts, ZP FA1664 Optional Kit for wood post mounting [L]...4 ⅜" x 3.5" Lag Screw, ZP [H]...4 ⅜" Flat Washers, SS [A] [B] [C] [D] [E] [F] [G] [H] [J] [K] [L] 4 QM1248 Munters Corporation, August 2013

Chapter 1 Unpacking the Equipment 1.2 Fan Dimentions Before beginning installation, check the overall condition of the equipment. Remove packing materials, and examine all components for signs of shipping damage. Any shipping damage is the customer s responsibility and should be reported immediately to your freight carrier. Fan A (to pipe) B 51 25 3 8 56" 42 5 8" Length of Pipe A 14" B 10" Munters Corporation, August 2013 QM1248 5

Installation Instructions 2. 2.1 INSTALL Step 1 Drill (2) 3 8 holes in each strut 3 5 8 above the lower bend in the strut. One hole will be 7 8 from the front edge of the strut and the other hole will be 2 5 8 from the first. See Figure 1. 3 5 8 2 5 8 7 8 Figure 1 Lower bend in strut Front edge of strut Step 2 Attach fan hanger brackets to fan strut using (2) 2.25"L. Hex Bolts [D], (4) Flat Washers [B], (2) Nylock Nuts [C]. See Figure 2. Repeat for second Bracket. Fan hanger bracket Nut [C] Fan Hanger Bracket Flat Washer [B] 2.25"L Hex Bolts [D] Flat Washer [B] Figure 2 6 QM1248 Munters Corporation, August 2013

Chapter 2 Instalation Instructions Step 3 Secure fan to fan pipe hanger using (2) pipe clamps. (4) 3"L. Hex Bolts [E], (8) Flat Washers [B] and (4) Nylock Nuts [C]. See Figure 3. Pipe hanger Nuts [C] Hex Bolt [E] Flat Washer [B] Flat Washer [B] Pipe Clamp Figure 3 Step 4 Attach Pipe Retainer to Mounting Plate using (4) Carriage Bolts [A], (4) Flat Washers [B], and (4) Nylock Nuts [C] (provided). Thread nut on so it is flush with end of bolt. See Figure 4. NOTE: For 'I' Beam Mounting go to step 4 & 5, for Wood Post mounting go to step 6, for Round Post mounting go to Step 7. Flat Washer [B] ⅜" Carriage Bolt [A] ⅜" Nut [C] Mounting Plate Pipe Retainer Figure 4 Munters Corporation, August 2013 QM1248 7

Chapter 2 Instalation Instructions 2.2 Beam Mounting Step 5 Thread Set Screw [G] into 'I' Beam Clamp [F] so it is flush on the inside of clamp. Attach (4) 'I' Beam Clamps [F] to beam by tightening square headed bolt. 'I' Beam Clamps [F] should be spaced 11½" on center apart. The set screws [G] that the mounting plate assembly mounts to can be 2 5 8" - 4 3 8" O.C. or 6" - 7 3 4" O.C. See Figure 5. Step 6 Place mounting plate assembly on 'I' Beam Clamp threaded inserts and fasten in place using (4) Flat Washers [H], (4) Split Lock Washers [J] and (4) Nuts [K]. See Figure 6. Go to step 9. 'I' Beam 'I' Beam Clamp [F] Set Screw [G] 11½" 2 5 8" - 4 3 8" 6" - 7 3 4" Flat Washer [H] Figure 5 Split Lock Washer [J] ⅜" Nut [K] Mounting plate assembly Figure 6 8 QM1248 Munters Corporation, August 2013

Chapter 2 Instalation Instructions 2.3 Wood Post Mounting Step 7 Attach mounting plate assembly to wood post using (4) ⅜" x 3.5" Lag Screws [L] and Flat Washers [H]. See Figure 7. Flat Washer [H] Wood post ⅜" x 3.5 Lag Screw [L] Mounting Plate Assembly Figure 7 2.4 Round Post Mounting Step 8 Attach Mounting Plate assembly to round post using (2) 'U' bolts and flat washers, lock washers and nuts (not provided). See Figure 8. Flat Washer Round Post Lock Washer ⅜" Nut 'U' Bolt (not provided) Mounting plate assembly Figure 8 Munters Corporation, August 2013 QM1248 9

Chapter 2 Instalation Instructions Step 9 Slide fan pipe hanger into mounting plate assembly so pipe stops at tab. Rotate fan and fan pipe hanger to desired angle and tighten nuts on pipe retainer to secure fan in place. See Figure 9. Pipe Retainer Figure 9 Step 10 Rotate fan to desired angle for air flow. Tighten bolts of pipe clamps to secure fan at desired angle. See Figure 10A & 10B. The standard angle is 10-15 O. 75 O 10-15 O Figure 10A Figure 10B NOTE: Fan Comes ungaurded. If a Guard Kit was purchased, Install guard at this time. Step 11 Proceed to fan installation instructions for wiring and operation. 10 QM1248 Munters Corporation, August 2013

Exploded View 3. 'I' Beam by others Wood Beam by others Optional FA1662 Kit Optional FA1664 Kit Munters Corporation, August 2013 QM1248 11

Chapter 3 Exploded View Item Cat. No. Part Name/Description Qty. 1 FH1715 Fan Pipe Hanger 1 2 KS1509 ⅜"-16 x 1.5" Carriage Bolt, ZP 4 3 FH1716 Fan Hanger Mounting Plate 1 4 FH1717 Fan Hanger Pipe Retainer 1 5 KW3036 ⅜" Flat Washer, ZP 20 6 KN1709 ⅜"-16 Nylock Nut, ZP 12 7 KS1037 ⅜"-16 x 3" Hex Bolts, ZP 4 8 KS1064 ⅜"-16 x 2.25" Hex Bolts, ZP 4 9 FH1718 Fan Hanger Bracket 2 10 FH1612 Pipe Clamps 2 Optional FA1662 Kit 11 KX2803 ⅜" 'I' Beam Clamp, Carbon Steel 4 12 KS2805 ⅜" x 1.75", Int - HX, Set Screw 4 13 KW3007 ⅜" Flat Washer, Type - A, Narrow, SS 4 14 KW3509 10mm Split Lock Washer, ZP 4 15 KN1011 ⅜"-16 Hex Nut, ZP 4 Optional FA1664 Kit 16 KS2462 3 8 x 3.5 LAG Screw, GV 4 13 KW3007 3/8 Flat Washer, Type - A, Narrow, SS 4 AX51 with Munters Drive Fan Hanger Kit is developed and produced by Munters Corporation, Mason, Michigan U.S.A. 1-800-227-2376 Munters Europe AB, Isafjordsgatan 1, P.O. Box 1150, SE-164 26 Kista, Sweden. Phone +46 08 626 63 00, Fax +46 8 754 56 66. Munters Corporation 4215 Legion Drive Mason, MI 48854-1036 U.S.A. Phone +1 800-227-2376, Fax +1 517-676-7078 www.munters.us/aghort Australia Munters Pty Limited, Phone +61 2 6025 6422, Brazil Munters Brasil Industria e Comercio Ltda, Phone +55 41 3317 5050, Canada/US Munters Corporation Mason, MI Phone +1 517 676 7070, China Munters Air Treatment Equipment (Beijing) Co. Ltd, Phone +86 10 80 481 121, Denmark Munters A/S, Phone +45 9862 3311, India Munters India, Phone +91 20 3052 2520, Indonesia Munters, Phone +62 818 739 235, Italy Munters Italy S.p.A., Chiusavecchia, Phone +39 0183 52 11, Japan Munters K.K., Phone +81 3 5970 0021, Korea Munters Korea Co. Ltd., Phone +82 2 761 8701, Mexico Munters Mexico, Phone +52 818 262 54 00, Russia Munters AB, Phone +7 812 448 5740, Singapore Munters Pte Ltd., Phone +65 744 6828, South Africa and Sub-Sahara Countries Munters (Pty) Ltd., Phone +27 11 997 2000, Spain Munters Spain S.A., Phone +34 91 640 09 02, Sweden Munters AB, Phone +46 8 626 63 00, Thailand Munters Co. Ltd., Phone +66 2 642 2670, Turkey Munters Form Endüstri Sistemleri A.Ş, Phone +90 322 231 1338, USA Munters Corporation Mason, MI Phone +1 517 676 7070, Vietnam Munters Vietnam, Phone +84 8 3825 6838, Export & Other countries Munters Italy S.p.A., Chiusavecchia Phone +39 0183 52 11 12 QM1248 Munters Corporation, August 2013