Fire Safety Basics: Evacuation & Emergency Response Teams

Similar documents
Fire Safety Basics II: Detection & Warning Systems

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection

November Safety Subject

EXIT ROUTES, EMERGENCY ACTION PLANS, AND. FIRE PREVENTION PLANS. PART 1: INTRODUCTION

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

What are the Contents of an Effective Fire Safety Plan? Name: Date: Address of Project: Building Permit Number:

Fire evacuation drill

Emergency Action Plan Leading the Fight

OAK GROVE SCHOOL DISTRICT SCHOOL SITE FIRE PREVENTION PLAN

Emergency Action Plans (OSHA ) Abstract. Introduction. Emergency Action Plan (EAP) Elements of an EAP

EMERGENCY EVACUATION POLICY FOR 100 CHEROKEE STREET BUILDING

Emergency Evacuation Plan South Patterson Building (SPB)

IRVING FIRE DEPARTMENT EMERGENCY PLANS

Agency for Health Care Administration

Fire Safety Plan (FSP) Review Checklist 1

Fire Safety Plan (FSP) Review Checklist 1

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

HUDSON VALLEY COMMUNITY COLLEGE BUILDING EMERGENCY ACTION PLAN FOR OUTSIDE EMERGENCY ASSISTANCE: DIAL 911 TO REACH THE SARATOGA CTY POLICE & FIRE

FIRE SAFETY PLAN ADMINISTERED BY: DEPARTMENT OF ENVIRONMENTAL HEALTH AND SAFETY

ICC CODE CORNER 2015 International Fire Code

Life Safety - Means of Egress/Exits NFPA 101

Exit Routes. Introduction/Overview. OSHA Regulations. Exit Route

HAWAII ADMINISTRATIVE RULES DEPARTMENT OF LABOR AND INDUSTRIAL RELATIONS DIVISION OF OCCUPATIONAL SAFETY AND HEALTH GENERAL INDUSTRY STANDARDS

[Name/title] is the Alternate Safety Officer/ Alternate Emergency Coordinator.

Emergency Planning and Preparedness

DEALING WITH FIRE SAFETY

INFORMATION BULLETIN

Steven Craft, PhD, P.Eng. FIRE SAFETY DURING THE COURSE OF CONSTRUCTION

Emergency Action Plan

Emergency Evacuation Plan. Kettering Labs. School of Engineering

Board Policy 6819 Fire Safety and Prevention Plan

Agency for Health Care Administration

Harvard University - OEB Glasshouse Emergency Evacuation Plan

FIRE SAFETY AND EVACUATION PLANNING FOR ASSISTED LIVING FACILITIES AND NURSING HOMES

FIRE PROTECTION PROGRAM

Agency for Health Care Administration

EMERGENCY PREPAREDNESS: EVACUATIONS

TABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2

Truro Police Department. Fire Emergencies. Policy Number: OPS-9.02 Effective Date: June 1, 2000 REFERENCE:

RAMBLER PARK FIRE SAFETY INFORMATION

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

School EMERGENCY PLAN

Property Name & Address [ Property Name ] - [ Property Address ]

Dutchess Community College. Emergency Action Plan. Conklin Hall College Residence

Lauzon Life Safety Consulting

EMERGENCY PLANNING AND PREPAREDNESS

Other EC and LS documents may be requested by surveyors, as needed, throughout the survey.

911 Consulting. New York City Emergency Action Plans 18 Obligations of Tenant/Employers in High Rises

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

Written Fire Safety Plans

Charlotte Building, 17 Gresse Street, London W1T 1QL

Alternate Evacuation Route B: Secondary direction of egress considered safe with the information available.

JEFFERSON COUNTY PUBLIC SCHOOLS FIRE WATCH PROGRAM

FIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES

Cumru Township Fire Department 4/27/10 Standard Operating Guidelines Page: 1 of 6 Section 15.07

C. None (No sprinkler system) K3 E. NUMBER OF BEDS CERTIFIED FOR MEDICAID

FIRE SAFETY INSPECTION REPORT

TG FIRE DRILLS. Office of the Fire Marshal and Emergency Management

SURREY FIRE SERVICE. Construction Fire Safety Plan Bulletin

GUIDELINES FOR EMERGENCY PLANNING AND PREPAREDNESS. High-Hazard

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

EMERGENCY PLANNING AND PREPAREDNESS

Emergency Action Plan. Emergency Response Plan. Emergency

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

GEORGIA DEPARTMENT OF CORRECTIONS Standard Operating Procedures

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

Fire Evacuation Manual

STATE OF MARYLAND DEPARTMENT OF STATE POLICE OFFICE OF THE STATE FIRE MARSHAL

Ten-Point Checklist for Emergency Preparedness

Date Issued: December 14, 2017 Revision: 2.1

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

NY Fire Safety Institute Coordinator of Fire Safety & Alarm Systems F-80

Washoe County Department of Social Services

FORM MUST BE SIGNED AND RETURNED FOR VENDOR PARTICIPATION

FIRE PROTECTION INTRODUCTION

EMERGENCY EVACUATION Can your staff evacuate your occupants safely?

EMERGENCY EVACUATION How prepared are you?

Emergency Action Plan for Sycamore House 3818 Winding Way

CHILD CARE CENTER INSPECTION CHECKLIST 06C

SAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly.

Family Foster Home Fire Safety Evaluation Checklist Instructions

EMERGENCY ACTION PLAN

Project: Location: Date Prepared: Last Reviewed:

FIRE SAFETY AND PREVENTION POLICY

161 Rosebery Avenue, London, EC1 Fire Safety Management Plan & Evacuation Procedures

Muster Area in North Parking Lot

Emergency Evacuation Plan and Implementation Guidelines The Pennsylvania State University

ADMINISTRATIVE SERVICES MANUAL

University of Maryland FIRE EVACUATION PLAN Columbus Center POLICE FIRE MEDICAL EMERGENCY - 911

The Social Accountability International (SAI) Fire Safety Checklist

FIRE PREVENTION PLAN EMERGENCY ACTION

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

SCALES NW EMERGENCY ACTION PLAN

VICI. Emergency Evacuation Plan

Crosswalk of 2014 HFAP Standards against HFAP Standards Acute Care Hospital Manual

Department of Veterinary Medicine

Guidance for writing a Personal Emergency Evacuation Plan (PEEP)

Sample Evacuation I Fire Safety Plan

Emergency Action Plan For Alumni Center 1507 Dana Avenue

Transcription:

Fire Safety Basics: Evacuation & Emergency Response Teams یتم تدرس ھذا الموضوع في دورات أوشا التالیة: q OSHA 510: Occupational Safety and Health Standards for the Construction Industry. q OSHA 511: Occupational Health and Safety Standards for General Industry. سبتمبر 2011 جزیرة تاروت السعودیة qosha 2015: Hazardous Materials 1

دورات الاوشا إذا أردت دورات الاوشا بصیغة بوربوینت علیك ترجمة موضوعین للغة العربیة من دورات المقدمة في موقع الا طفاء والسلامة. ھندسة للتوصل: alruwaie@gmail.com

Fire Safety Basics: Evacuation & Emergency Response Teams Dr. Jennifer L. Schneider, CIH Rochester Institute of Technology http://online.rit.edu

Means of Egress (1910 1910.35) Continuous and unobstructed way of exit travel from any point in a bldg to a public way Way of exit access The exit The way of exit discharge Must be free, non locked, visible & marked (6 inch EXIT letters) Passages that could be mistaken as exits must be marked as not being exits (ie not an exit ) or be so arranged to minimized being mistaken as an exit Two remote means of egress through lesser hazard occupancy

Exits a building s exits are the most important factor involved in protecting life from fire Exits often are inadequate in many buildings Consider the design of exits in a building s total fire safety system Must be sufficient in size and number to allow an orderly evacuation. A building s population and degree of hazard are the major factors when designing exits Every building or structure, and every section or area in it, shall have at least two separate means of exit.

Exits Arrange exits so that the possibility of any one fire blocking all exits is minimized. Safe exits require a safe path of escape from the fire with the least possible travel distance to the exit Path should be large enough to permit all occupants to reach a place of safety before they are endangered by the fire or by smoke and toxic gases. NFPA 101, Life Safety Code, provides a reasonable and comprehensive guide to exit requirements If local state or provincial, or federal codes may contain more rigid recommendations and therefore will apply

3 Components of an Exit Exit Access Exit Exit Discharge

Exit design Not less than 28 inches Determined by the number of people and travel distance Shielded from high hazard occupancy Exit doors: side hinged, swing type that open in the direction of travel when area is occupied by more than 50 persons or high hazard occupancy

Exit Design ( now usu. by calculated evac times): GSA stds: evac to safe area w/in 90 secs of alarm, a portion of the time (15 secs. ) can be used in traveling toward the fire - i.e. as in a dead end corridor; all occupants must reach refuge w/ in 5 min of downward vertical travel or w/in 1 min upward vertical travel;

Exit Design ( now usu. by calculated evac times): Calculation: T= N + n r x u where T = time in mins. req d for evac by stairs N = number of people in blg above ground floor n = number of people who can stand on stairs, at 3 ft sq/ person, or number of people on floor (lesser of the two) r = rate of discharge in people / unit exit width u = number of 22 in. exit units of stair width (note:12 additional inches counts as ½ exit width)

Exit Design ( now usu. by calculated evac times): Also must consider the time of evac. for the person from the most remote point to reach the stairs or exit and add into the calculation; This calc. will give you the MINIMUM time for a perfect evacuation; safety factors must be built in!!

Emergency Planning (1910.38) Training required when Employee Emergency Plans and Fire Prevention Plans are developed or responsibilities change Both plans should be written Evacuation Drills should be conducted at least once per year (not an OSHA requirement, but good practice and in many jurisdictions, a requirement of local law or regulation) primary and secondary routes of evac practiced head count duties

Emergency Response Teams Fire Brigades 1910.156- incipient- basic fire extinguisher use as per FPP, annual training required structural - equipment use!!!; quarterly training required, falls under many other standards at this point;

Emergency Response Teams Medical response - differs by injury potential and response time ( near proximity - 1910.151) Watch other regs like confined space, BBP as this could impact what you do

Outside responders Once arrive onsite, are in command of site to protect their personnel & public safety Should invite local fire to tour site annually for familiarity Discuss what, if any of the facility equipment they expect to use (usually very little) & response capabilities Maintain access to radio, fire panel, risers & hydrants always Have plans, MSDS, etc at arrival location for their use