General Purpose Laminar Flow Cabinets, Horizontal and Vertical

Similar documents
General Purpose Laminar Flow Cabinets, Horizontal and Vertical

General Purpose Laminar Flow Cabinets, Horizontal and Vertical. Horizontal Flow Vertical Flow

Innovation in air purification unmatched air quality

Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand. Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR

Automatic Cyanoacrylate Fuming Chamber 24 33T 60T 72XL. Safely Detect Quality Latent Prints and Reproducible Results

Precision Containment for All Applications

General Application Ductless Fume Hoods

General & Special Purpose Forensic Evidence Drying Cabinets

Polymerase Chain Reaction Cabinets The Proven Solution for Contaminant-Free PCR. Esco PCR Cabinet, Model PCR-4A_. Shown with optional support stand.

General & Special Purpose Forensic Evidence Drying Cabinets

Laminar Flow Clean Benches, Horizontal and Vertical The Leading Solution for Research Laboratories

LABORATORY CABINETS 103

Animal Containment Workstation The Portable Safety Solution for Animal Research Laboratories

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

Air Showers The Safety Solution for Animal Research Laboratories. Viva Air Shower, Model - EAS-1B.

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

Green Performance Ductless Fume Hoods

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

Fingerprint Development Chamber 34

Class II, Biological Safety Cabinets The Industry s Most Energy Efficient Class II Cabinet

European Standard EN12469:2000 Tested. Class II Design: Personnel, Product / Sample, Environment Protection

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

Clean Bench Animal Transfer Stations

XPert Balance and Bulk Powder Enclosures

L a b o r a t o r y E q u i p m e n t C a t a l o g

PROTECTION PRODUCT. Series CleanLamin AirFlow. Cabinets Series CLF, DLF and DLF/PCR

Low Noise, Class II Microbiological Safety Cabinets The Industry's Most Comfortable, Energy Efficient Cabinet

Microbiological Safety Cabinets

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

Bedding Disposal Workstations The Portable Safety Solution for Animal Research Laboratories. Viva Bedding Disposal Workstation, Model VBD-4A_.

Class III, Biological Safety Cabinets The Premier Solution for High Containment Laboratories

CIRCULAIRE LAMINAR AIR FLOW

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

Faster BH-EN and BHG Class II Microbiological Safety Cabinets

CLEAR ROOM EQUIPMENT CLEAR ROOM EQUIPMENT AIR SHOWER PRESSURE RELIEF DAMPER PASS BOX PASS THOUGH CLEAN BENCH VERTICAL CLEAN BENCH HORIZONTAL

Laboratory Equipment LAMINAR FLOW CABINETS ENVAIR ECO AIR H ISO CLASS 3 HORIZONTAL PRODUCT PROTECTION CABINET

Biological Safety Cabinet

Forma 1400 Series Class II, Type A2 Biological Safety Cabinet. Superior Ergonomics, Uncompromising Safety

ALMOST Rocket Science FORTUNA. Clean Air Cabinet. Vertical Laminar Flow Cabinet

CLEAN AIR SYSTEM.

FagronLab NP-1 UV. Negative pressure workbench. User Manual

B. Design meeting requirements of the particular class and type of cabinet as follows:

Safe Operating Procedure (Revised 2/10)

INCREASE YOUR LAB EFFICIENCY

Class II, Type B2 (Total Exhaust) Biological Safety Cabinets The Safety Solution for Life Science Laboratories

Class II Biological Safety Cabinets The Safety Solution for Life Science Laboratories

Class II Microbiological Safety Cabinet The Industry's Premier Biological Safety Solution from Esco

ENVAIR lab CO2 Incubator

Biological Safety Cabinets. Presented by Mr. Rene Soetens President

Low Noise, Class II Biological Safety Cabinets The Safety Solution for Life Science Laboratories

Airstream Class II, Biological Safety Cabinet (E-series),

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

LABORATORY EQUIPMENT. Fume Hoods. Class II Biological Safety Cabinets. Carbon Filtered Enclosures. Ventilation Stations

ANIMAL RESEARCH PRODUCTS. Biological Safety Cabinets Animal Transfer Stations

M Series Fan Filter Units

SECTION BIOLOGICAL SAFETY CABINETS AND LAMINAR AIRFLOW WORK STATIONS

Laminar Flow Cabinets eco air V

MULTI-TECH II INSTRUCTION MANUAL. Model XJ-3000D

Biological Safety Cabinets or Fume Hoods Which one to use?

How to comply with CDC Guidelines

IVF/ART Series Laminar Flow Cabinets

OPERATOR S MANUAL. Horizontal Laminar Flow Clean Bench

Guardian CR2000 Overhead Ionizing Air Blower. User s Manual

DOWNDRAFT BENCH SERIES

CentriVap. Centrifugal Vacuum Concentrators and Cold Traps

Adv. 8.4 Guidelines for Biosafety Cabinets Rev

Labconco XPress Laboratory Equipment Where You Need It, When You Need It

Class II, Microbiological Safety Cabinets The Industry's Premier Energy Efficient Solution from Esco

Envair Lab OSN Eco Air H. Horizontal Laminar Flow Product Protection Hoods

BioSafety Cabinet- Class 100

Chargebuster Ion Gun Installation, Operation and Maintenance

Class II, Microbiological Safety Cabinets The Industry's Premier Energy Efficient Solution from Esco

TOPAIR CLEAN AIR SOLUTIONS CATALOG

OPERATOR S MANUAL DEAD AIR WORKSTATION. AC600 Series Dead Air Box & Timed UV Light with UVTect Controller

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

Laboratory Automation & Robotic System Enclosures

Forced Convection. Laboratory Ovens. Isotherm Forced Convection Laboratory Ovens, 110L, 54L and 32L models.

CENTRIVAP CENTRIFUGAL CONCENTRATORS & COLD TRAPS

Kitchen Exhaust Air Cleaning Systems

Chargebuster Ion Gun Installation, Operation and Maintenance

Gelaire BH-EN and UltraSafe cabinets

Ductless Fume Hoods, Chambers & Drying Cabinets

laboratory & sterilization technology

INCREASE YOUR LAB EFFICIENCY

Microbiological Safety Cabinets ENVAIR eco safe Basic Plus

Class II Biological Safety Cabinets The World's Leading Energy Efficient, Quiet, and Compact Biosafety Cabinet.

Microbiological Safety Cabinets ENVAIR eco safe Comfort

Table of Contents. Laboratory Fume Hoods. UniFlow Fume Hood Systems. Fume Hood System Components. Custom Hoods, Enclosures & Cabinets

Class II, Australian Biological Safety Cabinets The Safety Solution for Life Science Laboratories

Thermo Scientific 1300 Series A2

CelCulture. Cradle for Beautiful Cells. CelCulture Water-Jacketed CO 2 Incubator

Clean Air Products 90-Degree Low Profile Left Hand ADA Compliant Air Shower Purchase Specification

ORION. Safety Class 2 100% exhaust. ALMOST Rocket Science

2 Microbiological Safety Cabinet

cgmp STEAM STERILIZERS

Welcome to the IQAir revolution.

INCREASE YOUR LAB EFFICIENCY

Transcription:

General Purpose Laminar Flow Cabinets, 24 36 48 60 72 96 The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. VLF-48 Provides reliable protection for samples and work processes for a multitude of applications.

p:2 Product Overview Product Features General Purpose Laminar Flow Cabinets, 24 36 48 60 72 96 JUMP TO: Features and Callouts (p.3) Airflow and Filtration (p.4) Specifications (p.5) Options, Accessories and Standards (p.8) Purair General Application Laminar Flow Cabinet Group Excellent protection of equipment and materials inside the cabinet from particulate contamination. Rich set of options to customize cabinets for a multitude of applications. Easy to change filters. High airflow capacity. Choose from standard powder coated interior or stainless steel interior (-SS models). Purair VLF cabinets provide vertical airflow and are available in 2', 3', 4', 5', 6' and 8' widths for general applications. Purair HLF cabinets provide horizontal airflow and are available in 2', 3', 4', 5', 6' and 8' widths in standard and extra tall heights for general applications. HLF-72; shown with optional mobile base stand. APPLICATIONS Uses include applications where there is no generation of biohazardous materials and operator protection is not required: INTRODUCTION Air Science Purair Laminar Flow cabinets are a series of high efficiency products designed to protect equipment and other contents of the work zone from particulates, for applications sensitive to such contamination. It is ideally suited for use with non-hazardous contaminants STERILE COMPOUNDING COMPLIANT When used according to best practices, the LF Series cabinet encourages compliance with criteria set forth by USP 797 for sterile preparation in pharmaceutical compounding of nonhazardous agents. These include injectables, IV admixtures, pastes and ointments and irrigating solutions which are protected by filtered air over the work surface in a laminar flow. Mycology and food microbiology Plant and mammalian cell culture and when flexible access to the equipment in the work zone is desired. At the heart of the Purair Laminar Flow Clinical pharmacy and hospital use Clean rooms Semiconductor assembly Pharmaceutical cabinet product line is the Air Science Multiplex ULPA Filtration Technology that creates a clean work environment over a wide range of applications. Aerospace Medical device assembly Research Laboratories Made in the U.S.A. This Product Exceeds OSHA, ANSI and Other International Standards.

p:3 Product Features Product Features General Purpose Laminar Flow Cabinets, 24 36 48 60 72 96 D J PRODUCT FEATURES: A. Cabinet lighting located away from laminar flow area. B E H I N B. Optional ultraviolet lamp to sterilize and decontaminate work zone and cabinet contents between operating periods. C. Optional Night Door/Cover to protect cabinet interior when blowers are off. Contains UV radiation when UV activated. D. Disposable polyester fiber pre-filter with 85% arrestance. A E. Long-life Camfil-Farr ULPA main filter with efficiency of 99.999% at particle sizes between 0.1 to 0.3 μm. O F. Side window that allows ambient illumination into the chamber and provides users with an unobstructed view of its contents from three sides. Side windows not available on stainless steel models. M G P F G. GFCI outlet to power equipment in cabinet. H. ebmpapst external rotor blower. L I. Control panel On/Off switch for fan, lighting, GFCI outlets, Minihelic ULPA pressure gauge to measure filter performance, UV lamp key switch. Q J. Fan speed control. K. Base Stand: Optional mobile cart with locking casters, includes a convenient lower shelf. L. Stainless steel work surface with ULPA filter spill-retention lip on HLF units. K M. Ergonomically angled front improves reach and comfort. N. MICROgone antimicrobial coating on all painted metal surfaces minimizes contamination white color. O. Protected work zone environment created for optimum product performance. P. Optional IV Bar with "S" hooks. C Q. Optional petcock service fixture (Maximum 4 per unit). VLF-48, shown with optional mobile base stand and other selected options. Control panel On/Off switch for fan, lighting, GFCI outlets, Minihelic ULPA pressure gauge to measure filter performance, UV lamp key switch. Air Science 120 6th Street Fort Myers, FL 33907 T/239.489.0024 Toll Free/800.306.0656 F/800.306.0677 www.airscience.com

p:4 Product Filtration Product Features General Purpose Laminar Flow Cabinets, 24 36 48 60 72 96 THE AIR SCIENCE PERFORMANCE ADVANTAGE Each Air Science Purair Laminar Flow cabinet includes features expressed through sound design and certified quality construction. Options and accessories add functional performance to meet specific applications. Professional Quality. Air Science cabinets comply with current technical and safety regulations. Advanced Filtration. Air Science Multiplex ULPA Filtration provides high performance protection. Industrial Components. The cabinet frame and work surfaces are durable and chemically resistant for long service life. All cabinet components are clean room compatible. Each cabinet is individually factory tested for safety and performance in accordance with international standards. The main filter gasket evenly seals the filter face to prevent bypass air leakage. Our pourin-place silicone gasket out performs traditional style stick-on "dove-tail" gasketing. VERTICAL AND HORI- ZONTAL AIRFLOW: Performance of Purair vertical and horizontal flow cabinets is the same and the choice is largely a matter of user preference. Horizontal flow cabinets create less turbulence at the work surface, as the airflow does not directly impinge upon it but rather is smoothly drawn across it. The airflow on the Purair vertical flow cabinets directly strikes the work surface. However, to minimize this effect, vertical laminar flow cabinets are manufactured with rear wall perforations to reduce turbulence by removing a small amount of air at the rear of the cabinet. Turbulence is a problem only when it is excessive. The design of vertical flow cabinets is customized more easily (at a lower cost) as required. Airflow in a horizontal flow cabinet exits directly towards the user, whereas the airflow in a vertical flow cabinet strikes the work surface first and exits towards the user indirectly. It should be noted, neither style laminar flow cabinet offers any operator protection. Large or tall equipment in a horizontal flow cabinet will interrupt the airflow more than in a vertical flow cabinet. This may create more turbulence and dead spots where airflow is lower than elsewhere. Vertical flow cabinets are not so impacted by large equipment. In vertical flow cabinets, the ULPA filter is mounted above the work surface. This provides a larger work space, both taller and deeper, that may be appropriate for large equipment in the work zone. PURAIR VERTICAL AIRFLOW PATTERN ULPA Filter Room Air Intake Rear wall perforations to reduce work surface turbulence Exhaust Air Room air enters from the top of the cabinet through a disposable pre-filter; this traps larger particles and increases filter life. Air is forced evenly across the ULPA filter in a stream of clean, uniform air within the work zone. This dilutes and flushes airborne contaminants from the interior. A nominal filter face velocity of 0.35-0.45 m/s (70-90 fpm) ensures a sufficient number of air changes to maintain cleanliness within the work zone. The purified air travels down to the work zone in a vertical, unidirectional downflow stream, exiting the work zone across the entire open cabinet front area after deflecting off the work surface. Rear wall perforations are designed to reduce work surface turbulence and minimize the possibility of dead air corners in the work zone. PURAIR HORIZONTAL AIRFLOW PATTERN ULPA Filter Room Air Intake Purair Laminar Flow Cabinets maintain a 0.35-0.45 m/s (70-90 fpm) airflow velocity, measured 6"/150 mm from the filter with a uniformity of +/- 20% across the filter face. This face velocity is in compliance with USA and international standards for safety and performance. The ULPA filters are easy to replace with common tools. Room air enters from the top of the cabinet through a disposable pre-filter; this traps larger particles and increases filter life. Air is forced evenly across the ULPA filter in a stream of clean, uniform air within the work zone. This dilutes and flushes airborne contaminants from the interior. A nominal filter face velocity of 0.35-0.45 m/s (70-90 fpm) ensures a sufficient number of air changes to maintain cleanliness within the work zone. The purified air travels across the work zone in a horizontal, unidirectional stream and exits the work zone across the entire open cabinet front. This Product Exceeds OSHA, ANSI and Other International Standards. Pre-Filter Pre-Filter Exhaust Air Fan / Blower Fan / Blower

p:5 Product Features & Specifications Product Features General Purpose Laminar Flow Cabinets, 24 36 48 60 72 96 PURAIR LAMINAR FLOW CABINET FEATURES & BENEFITS Purair Laminar Flow cabinets are available in 2 model types with various sizes and options for a total of 18 standard models. Choose from standard powder coated interior or stainless steel interior (-SS models). Purair Laminar Flow Cabinets are shipped fully assembled. No installation is required; just plug them in and use them. Products are designed for desktop use, or may be installed on an optional mobile base stand. The rear wall of vertical flow cabinets is perforated to reduce work surface turbulence by removing some of the airflow to the rear. Horizontal flow cabinets are designed with a lip on the rear of the work surface to protect the ULPA filter from spills. High capacity air handling system delivers flow velocity of 0.35-0.45 m/s (70-90 fpm). Purair VLF and HLF cabinets have an ULPA filter pressure gauge to measure filter performance. The Air Science filters are easy to access, easy to change. Purair Laminar Flow products are constructed of steel with Air Science s exclusive MICROgone antimicrobial powder finish coating. Accessories include an IV bar, service fixtures, base stand, UV lamp, and front door/cover. VLF-60-SS, stainless steel interior, shown with optional mobile base stand; see specifications. VLF-24 VLF-36 VLF-48 VLF-60 VLF-72 VLF-96 VLF (side view) MODEL DIMENSIONS WEIGHT (lbs/kg) Metal Interior Stainless Interior Nominal Width Internal Height Internal Depth External (W x D x H) Shipping (W x D x H) Net Ship Vertical Laminar Flow Cabinets VLF-24 VLF-24-SS 28.4" x 29.25" x 47.25" 721 x 743 x 1200 mm 40" x 44" x 54" 1016 x 1118 x 1372 mm 181 / 82 288 / 131 VLF-36 VLF-36-SS 36" 914 mm 40.4" x 29.25" x 47.25" 1026 x 743 x 1200 mm 45" x 44" x 54" 1143 x 1118 x 1372 mm 268 / 122 371 / 168 VLF-48 VLF-48-SS 48" 1219 mm 52.4" x 29.25" x 47.25" 1331 x 743 x 1200 mm 60" x 44" x 54" 1524 x 1118 x 1372 mm 322 / 146 478 / 217 VLF-60 VLF-60-SS 60" 1524 mm 64.4" x 29.25" x 47.25" 1636 x 743 x 1200 mm 70" x 44" x 54" 1778 x 1118 x 1372 mm 401 / 182 525 / 238 VLF-72 VLF-72-SS 72" 1829 mm 76.4" x 29.25" x 47.25" 1941 x 743 x 1200 mm 91" x 44" x 54" 2311 x 1118 x 1372 mm 478 / 217 595 / 270 VLF-96 VLF-96-SS 96" 2438 mm 100.4" x 29.25" x 47.25" 2550 x 743 x 1200 mm 110" x 44" x 54" 2794 x 1118 x 1372 mm 620 / 281 745 / 338 Specifications are subject to change without notice. Air Science 120 6th Street Fort Myers, FL 33907 T/239.489.0024 Toll Free/800.306.0656 F/800.306.0677 www.airscience.com

p:6 Product Specifications Product Features General Purpose Laminar Flow Cabinets, 24 36 48 60 72 96 HLF-24 HLF-36 HLF-48 HLF-60 HLF-72 HLF-96 HLF (side view) MODEL DIMENSIONS WEIGHT (lbs/kg) Metal Interior Stainless Interior Nominal Width Internal Height Internal Depth External (W x D x H) Shipping (W x D x H) Net Ship Horizontal Laminar Flow Cabinets HLF-24 HLF-24-SS 25.25" x 29.5" x 42.75" 641 x 749 x 1086 mm 40" x 44" x 54" 1016 x 1118 x 1372 mm 170 / 77 280 / 127 HLF-36 HLF-36-SS 36" 914 mm 37.25" x 29.5" x 42.75" 946 x 749 x 1086 mm 45" x 44" x 54" 1143 x 1118 x 1372 mm 246 / 112 371 / 168 HLF-48 HLF-48-SS 48" 1219 mm 49.25" x 29.5" x 42.75" 1251 x 749 x 1086 mm 60" x 44" x 54" 1524 x 1118 x 1372 mm 289 / 131 478 / 217 HLF-60 HLF-60-SS 60" 1524 mm 61.25" x 29.5" x 42.75" 1556 x 749 x 1086 mm 70" x 44" x 54" 1778 x 1118 x 1372 mm 344 / 156 494 / 224 HLF-72 HLF-72-SS 72" 1829 mm 73.25" x 29.5" x 42.75" 1861 x 749 x 1086 mm 91" x 44" x 54" 2311 x 1118 x 1372 mm 439 / 199 595 / 270 HLF-96 HLF-96-SS 96" 2438 mm 98.5" x 29.5" x 42.75" 2502 x 749 x 1086 mm 110" x 44" x 54" 2794 x 1118 x 1372 mm 878 / 398 725 / 329 Specifications are subject to change without notice. HLF-24XT HLF-36XT HLF-48XT HLF-60XT HLF-72XT HLF-96XT HLF-XT (side view) MODEL DIMENSIONS WEIGHT (lbs/kg) Metal Interior Stainless Interior Nominal Width Internal Height Internal Depth External (W x D x H) Shipping (W x D x H) Net Ship Horizontal Laminar Flow Cabinets with Extra Tall Option HLF-24XT HLF-24XT-SS 29.5" 749 mm 25.25" x 29.5" x 48.75" 641 x 749 x 1238 mm 40" x 44" x 60" 1016 x 1118 x 1524 mm 191 / 87 295 / 134 HLF-36XT HLF-36XT-SS 36" 914 mm 29.5" 749 mm 37.25" x 29.5" x 48.75" 946 x 749 x 1238 mm 45" x 44" x 60" 1143 x 1118 x 1524 mm 266 / 121 391 / 177 HLF-48XT HLF-48XT-SS 48" 1219 mm 29.5" 749 mm 49.25" x 29.5" x 48.75" 1251 x 749 x 1238 mm 60" x 44" x 60" 1524 x 1118 x 1524 mm 319 / 145 508 / 230 HLF-60XT HLF-60XT-SS 60" 1524 mm 29.5" 749 mm 61.25" x 29.5" x 48.75" 1556 x 749 x 1238 mm 70" x 44" x 60" 1778 x 1118 x 1524 mm 375 / 170 525 / 238 HLF-72XT HLF-72XT-SS 72" 1829 mm 29.5" 749 mm 73.25" x 29.5" x 48.75" 1861 x 749 x 1238 mm 91" x 44" x 60" 2311 x 1118 x 1524 mm 479 / 217 635 / 288 HLF-96XT HLF-96XT-SS 96" 2438 mm 29.5" 749 mm 98.5" x 29.5" x 48.75" 2502 x 749 x 1238 mm 110" x 44" x 60" 2794 x 1118 x 1524 mm 585 / 265 746 / 338 Specifications are subject to change without notice. Air Science 120 6th Street Fort Myers, FL 33907 T/239.489.0024 Toll Free/800.306.0656 F/800.306.0677 www.airscience.com

p:7 Product Specifications Product Features General Purpose Laminar Flow Cabinets, 24 36 48 60 72 96 PRODUCT SPECIFICATIONS Airflow Pattern Vertical Horizontal Air Science Model VLF-24 VLF-36 VLF-48 VLF-60 VLF-72 VLF-96 HLF-24 HLF-36 HLF-48 HLF-60 HLF-72 HLF-96 HLF-24XT HLF-36XT HLF-48XT HLF-60XT HLF-96XT HLF-72XT Airflow 1 0.45 m/s (90 fpm) 0.35 m/s (70 fpm) Filter Specifications Pre-Filter Main Filter 2 Size Clamping Cabinet Lighting UV Lamp 3 Noise, dba, 1 meter < Disposable polyester fibers with 85% arrestance > < ULPA, 99.999% efficient at particle sizes between 0.1 to 0.3 μm > < Full size of Work Zone > < Spring loaded, adjustable tension adjusts for gasket aging > < Compact fluorescent bulb removed from air stream > Optional 72 Side Windows (Not Available on Stainless Steel Models) Construction Visible Opacity UV Opacity Color Tempered Glass Transparent UV Absorbing Colorless Construction Color Work Surface GFCI outlet Finish (exterior) Finish (interior) < White epoxy coated steel frame > Stainless Steel Standard < MICROgone antimicrobial coating > < Standard models, MICROgone antimicrobial coating. -SS models, stainless steel interior. > Other Features Night Door/Cover Blower Electrical Optional < ebmpapst external rotor motor, permanently lubricated, low noise and vibration levels > < 120V, 60Hz or 220V, 50Hz voltages available. Specify when ordering. Other voltage options available. > Purair Laminar Flow cabinets maintain a 0.35-0.45 m/s (70-90 fpm) airflow velocity, measured 6"/150 mm from the filter with a uniformity of +/- 20% across the filter face. This face velocity is in compliance with USA and international standards for safety and performance. The ULPA filters are easy to replace with common tools. Electrical Controls Monitoring Warranty < Main On/Off Switch; Solid State Fan Speed Control with RFI filter; UV Timer and Key Switch if included > < Minihelic ULPA pressure gauge > Legacy Lifetime 1 Average airflow measured 6"/150 mm from filter face. Uniformity is +/- 20%. 2 Camfil-Farr filters; ULPA efficiency: 99.999% at particle sizes between 0.1 to 0.3 μm 3 UV Lamp includes Timer and Key Switch Air Science Laminar Flow cabinets incorporate ebmpapst permanently lubricated direct drive centrifugal blowers. The energy efficient design reduces operating costs and has extremely low noise and vibration levels. This Product Exceeds OSHA, ANSI and Other International Standards.

p:8 Product Options Product Features General Purpose Laminar Flow Cabinets, 24 36 48 60 72 96 OPTIONS & ACCESSORIES Vertical Horizontal Horizontal, Tall Air Science Model VLF-24 VLF-36 VLF-48 VLF-60 VLF-72 VLF-96 HLF-24 HLF-36 HLF-48 HLF-60 HLF-72 HLF-96 HLF-24XT HLF-36XT HLF-48XT HLF-60XT HLF-72XT HLF-96XT Mobile Base Stand-Wheels Floor-standing base for cabinet with locking castors 860 mm (34") height. VLF-BW-24 VLF-BW-36 VLF-BW-48 VLF-BW-60 VLF-BW-72 VLF-BW-96 HLF-BW-24 HLF-BW-36 HLF-BW-48 HLF-BW-60 HLF-BW-72 HLF-BW-96 HLF-BW-24XT HLF-BW-36XT HLF-BW-48XT HLF-BW-60XT HLF-BW-72XT HLF-BW-96XT Mobile Base Stand-Leveling Feet Floor-standing base for cabinet with leveling feet 860 mm (34") height. VLF-BL-24 VLF-BL-36 VLF-BL-48 VLF-BL-60 VLF-BL-72 VLF-BL-96 HLF-BL-24 HLF-BL-36 HLF-BL-48 HLF-BL-60 HLF-BL-72 HLF-BL-96 HLF-BL-24XT HLF-BL-36XT HLF-BL-48XT HLF-BL-60XT HLF-BL-72XT HLF-BL-96XT Mobile Base Stand-Motorized Floor-standing base for cabinet with motorized height adjustment. Specify locking castors or leveling feet. VLF-BM-24 VLF-BM-36 VLF-BM-48 VLF-BM-60 VLF-BM-72 VLF-BM-96 HLF-BM-24 HLF-BM-36 HLF-BM-48 HLF-BM-60 HLF-BM-72 HLF-BM-96 HLF-BM-24XT HLF-BM-36XT HLF-BM-48XT HLF-BM-60XT HLF-BM-72XT HLF-BM-96XT IV Bar and S Hooks Interior bar spanning the width of the cabinet to hang IV bags and other equipment using S hooks. Retrofit Kit. IV-VLF-24 IV-VLF-36 IV-VLF-48 IV-VLF-60 IV-VLF-72 IV-VLF-96 IV-HLF-24 IV-HLF-36 IV-HLF-48 IV-HLF-60 IV-HLF-72 IV-HLF-96 IV-HLF-24XT IV-HLF-36XT IV-HLF-48XT IV-HLF-60XT IV-HLF-72XT IV-HLF-96XT Service Fixtures Sidewall mounting for service fixture. Available for petcocks, faucets and valves. Retrofit Kit. Maximum of 4 per cabinet. SF SF SF UV lamp with Night Door/ Cover* Ultraviolet lamp for decontamination of interior surfaces. Includes a timer, and key switch UV operation must comply with local codes and facility safety practices. Contact your facility safety officer for details. Includes door/cover of UV absorbing polycarbonate plastic. Includes electrical interlock for blower, if present. UV-24 UV-36 UV-48 UV-60 UV-72 UV-96 UV-24 UV-36 UV-48 UV-60 UV-72 UV-96 UV-24XT UV-36XT UV-48XT UV-60XT UV-72XT UV-96XT Ionization Bar Generates a continuous flow of positive and negative ions balanced to neutralize surface static charges and to protect sensitive work product. ION-24 ION-36 ION-48 ION-60 ION-72 ION-96 ION-24 ION-36 ION-48 ION-60 ION-72 ION-96 ION-24XT ION-36XT ION-48XT ION-60XT ION-72XT ION-96XT Static Dissipative Work Surface Work surface composite resists and dissipates static charges to protect sensitive work product. SDW-24 SDW-36 SDW-48 SDW-60 SDW-72 SDW-96 SDW-24 SDW-36 SDW-48 SDW-60 SDW-72 SDW-96 SDW-24XT SDW-36XT SDW-48XT SDW-60XT SDW-72XT SDW-96XT *Sold together; safety precautions must be followed. Legacy Lifetime Warranty Protection This product is protected by the Air Science Legacy Lifetime Warranty which starts on the date of shipment from our factory. This limited warranty is the result of thousands of successful Air Science production applications in pharmaceutical, laboratory, forensic, industrial and educational applications. This warranty covers defects in materials and workmanship. Our liability under the Legacy Lifetime Warranty is, at our option, to repair or replace any defective parts of this equipment if you document that these parts were defective at the time we sold the product to you. Normal conditions apply. For details visit the Service section of our website at www.airscience.com. Quality Management Systems Environmental Management Systems Cabinet Performance STANDARDS AND COMPLIANCE ISO 9001:2008 ISO 14001:2004 EnergyStar Partner IEST-RP-CC002.2 AS 2252.6 Air Quality ISO 14644-1, Class 3 Sterile Compounding USP 797 Filtration Electrical Safety IEST-RP-CC034.1 IEST-RP-CC001.3 IEST-RP-CC007.1 EN 1822 UL-C-61010-1 CE Mark ROHS Exempt under EEE Category 9 120 6th Street Fort Myers, FL 33907 T/239.489.0024 Toll Free/800.306.0656 F/800.306.0677 www.airscience.com 2015 Air Science OW 10792 11/15 Air Science, Purair, Multiplex, and EFT are all registered trademarks of Air Science Corporation.

PCR Laminar Flow Cabinets The World s Most Practical Selection of Benchtop PCR Cabinets. 24 36 48 Purair PCR-24 Provides Contaminant-Free Interior for PCR Applications and Protects Against Cross-Contamination Meets or Exceeds OSHA, ANSI and other International Standards

p:2 Product Overview PCR Laminar Flow Cabinets 24 36 48 JUMP TO: Features and Callouts (p.3) Airflow and Multiplex Filtration Technology (p.4) Specifications (p.5) Options and Accessories (p.6) PCR Laminar Flow Cabinets Excellent interior protection from particulate contamination. Multiple options for customized applications. Easy-to-change HEPA filtration. Vertical laminar airflow. Powerful built-in UV lamp. Choose from 2', 3' or 4' models. Purair PCR-36, shown with UV lamp on and optional mobile base. APPLICATIONS These cabinets are intended for use in nonhazardous applications where biological or biohazard byproducts are not generated and user protection is not required. PCR Laboratories Forensics Pharmaceutical Sample Preparation General Research INTRODUCTION The Purair PCR laminar flow cabinet employs the Air Science Multiplex HEPA filtration technology to create a safe, energy-efficient contaminant-free environment. It is ideally suited for use with non-hazardous contaminants and when flexible access to the instrumentation in the cabinet is required. PCR WORKSTATION Polymerase chain reaction 1 (PCR) is a simple and inexpensive technique to make multiple copies of a targeted nucleotide sequence from a DNA sample, and to amplify sequences from small samples. This technique is widely used in genetics laboratories that work with DNA and RNA. Because PCR amplification is extremely sensitive to contamination, prevention of contamination requires good laboratory practices to minimize external or cross-contamination during reagent preparation, sample preparation and sample amplification. Cabinets are shipped fully assembled with standard power cords; no installation required. The integral UV lamp fixtures are pre-installed. All filters are preinstalled, easy to access and change. Products are designed for desktop use, or may be installed on an optional base stand or mobile cart. The high capacity air handling system delivers flow velocity of 0.45 m/s (90 fpm). Purair PCR cabinets are constructed of steel with a microbial powder finish coating. CONVENIENCE AND CONSTRUCTION BENEFITS The optional stainless steel work surface includes lips on all four sides to contain spills. Purair PCR cabinets are available in three model sizes with various options. 1 Polymerase chain reaction (PCR) is a patented process owned by Hoffman La Roche. This Product Exceeds OSHA, ANSI and Other International Standards.

p:3 Product Features PCR Laminar Flow Cabinets 24 36 48 PRODUCT FEATURES: A. Task Lighting: Fluorescent cabinet lamp located away from laminar flow area. B. Ultraviolet Lighting: Built-in ultraviolet lamp with timer permits decontamination between PCR cycles. Includes a double-flap safety cover of 0.2" (5 mm) UV absorbing 254 nm beta radiation resistant polycarbonate; provides superior operator protection while allowing easy access to the work zone. Timer can be set over range of 0 to 60 minutes or set to HOLD. C. Comfort: Ergonomically angled front improves reach and user comfort. D. Decontamination Shelf: Mounted on the back wall is proximate to the UV lamp for maximum exposure. E. Filter: Camfil Farr main HEPA filter with 99.99% efficiency for 0.3 micron particulates. The pre-filter can be changed while the unit is operating to prevent operator exposure to chemical vapors. F. Pass Through Ports: Convenient rear-wall pass through ports for safe routing of instrument cords, cables and leads. G. Double-Hinged Self-Locking Front Sash: With overlap closed, the cabinet sash protects samples on the work surface from contamination with 100 fpm airflow. The sash completely closes unit off when not in use and is easy to open and latch. H. Fan: High-performance ebmpapst centrifugal fan. I. Stand: Optional base stand converts to mobile cart with optional locking casters. J. Work Surface: Large polypropylene work surface, white or black standard, with optional stainless steel work surface available. K. Filter Door Lock: Prevents unauthorized removal or accidental exposure to dirty filters. L. Magnetic Door Latch: Safety interlock prevents accidental operator exposure when door is opened. OTHER FEATURES: 360 Degree Visibility: Clear back and side panels allow ambient illumination into the chamber and provide users with an unobstructed view of its contents. Standards Compliant: Performance specifications and construction meet or exceed OSHA, ANSI and relevant international standards to assure operator safety. Construction: All models are available in either metal or polypropylene construction, specify when ordering. Available in 120V, 60Hz or 220V, 50Hz models. Steel Support Frame: The chemical resistant epoxy coated steel frame adds mechanical strength. Optional all polypropylene construction is available if desired. Purair PCR-24, shown with optional mobile cart. The integrated control panel features an On/Off switch for the fan, light and UV lamp timer. Air Science 120 6th Street Fort Myers, FL 33907 T/239.489.0024 Toll Free/800.306.0656 F/800.306.0677 www.airscience.com

p:4 Product Filtration PCR Laminar Flow Cabinets 24 36 48 THE AIR SCIENCE PERFORMANCE ADVANTAGE Each Air Science fume hood includes features expressed through sound design and certified quality construction. Options and accessories add functional performance to meet specific applications. The optional Monitair microprocessor controller monitors and displays cabinet operating parameters, airflow, containment, and filter condition; emits audio and visual alerts if conditions become unsafe, all on a LCD display. Professional Quality. Air Science fume hoods comply with current technical and safety regulations. Multiplex Filtration. The Air Science Multiplex Filter offers a range of options for high performance protection. Industrial Components. The cabinet frame and work surfaces are durable and chemically resistant. Reliability. Internal systems are isolated from fumes, extending product life. PURAIR PCR AIRFLOW PATTERN Main Filters HEPA/ULPA Filtration Room Air Intake Fan/Blower Pre-Filter Pre-filter may be changed while unit is running. Exhaust Air Purair PCR cabinets incorporate energy-efficient ebmpapst permanently lubricated direct drive centrifugal blowers for maximum operational savings, low noise and minimal vibration. Air Science uses long-life Camfil Farr HEPA filters without aluminum separators to increase filter efficiency, minimize the potential for leakage and increase filter life. AIR SCIENCE MULTIPLEX FILTRATION TECHNOLOGY The Multiplex filtration consists of a pre-filter and main HEPA filter. The mechanical design enhances safety, convenience and overall value. The disposable pre-filter is accessible from the exterior top of the cabinet. A filter clamping mechanism allows for the filter to be easily installed and ensures an even seal at the filter peripheral face at all times to prevent bypass leakage. Purair PCR-36 shown with Multiplex filtration system. Room air enters from the top of the cabinet through the disposable pre-filter where larger particles are trapped, increasing the service life of the main HEPA filter. Air is forced evenly across the HEPA filter to deliver a flow of pure, uniform air within the work zone to dilute and flush airborne contaminants from the work area. A nominal filter face velocity of 0.45 m/s (90 fpm) ensures that there is sufficient number of air changes within the work zone to eliminate cross-contamination and to maintain optimum cleanliness. Purified air travels across the work zone to the work surface in a vertical, unidirectional downflow stream, and then exits the work zone across the front area of the cabinet. A. The main filter is easy to replace; no tools required. The filter clamps tightly against the filter gasket to prevent filter bypass and to maintain filter integrity. Pre-Filter HEPA MULTIPLEX FILTRATION SYSTEM SUMMARY Disposable polyester fibers with 85% arrestance. A self-contained filter designed to physically capture particles larger than 0.3 microns (HEPA) or 0.12 microns (ULPA). This Product Exceeds OSHA, ANSI and Other International Standards.

p:5 Product Specifications PCR Laminar Flow Cabinets 24 36 48 Purair PCR-24 Purair PCR-36 Purair PCR-48 Side View MODEL DIMENSIONS WEIGHT (lbs/kg) Nominal Width Internal Height Internal Depth External (W x D x H) Shipping (W x D x H) Net Ship PCR-24 26.75" 679 mm x 27" x 35" 610 x 686 x 889 mm 40" x 40" x 40" 1016 x 1016 x 1016 mm 72 / 33 129 / 59 PCR-36 36" 914 mm 26.75" 679 mm 36" x 27" x 35" 914 x 686 x 889 mm 40" x 40" x 40" 1016 x 1016 x 1016 mm 99 / 45 157 / 71 PCR-48 48" 1219 mm 26.75" 679 mm 48" x 27" x 35" 1219 x 686 x 889 mm 52" x 45" x 40" 1321 x 1143 x 1016 mm 138 / 63 195 / 88 PRODUCT SPECIFICATIONS Purair Model PCR-24 PCR-36 PCR-48 Airflow Pattern < Vertical downflow. > Airflow 1 < 0.45 m/s (90 fpm) > Filter Specifications Pre-Filter Main Filter 2 Clamping Lighting UV Lamp Side Windows Construction Visible Opacity UV Opacity Construction Color Work Surface Pass Through Ports Shelving Night Door/Cover Blower Electrical Electrical Controls < Disposable polyester fibers with 85% arrestance. > < HEPA efficiency, 99.99% at 0.3μm. > < Screw compression clamp. > < Compact fluorescent bulb, removed from air stream. > < 1 x 253.7 nanometer 15 watt. > < Polycarbonate. > < Transparent, colorless. > < UV absorbing. > < White epoxy-coated steel frame with blue legs on cabinet sides. > < Standard, white or black polypropylene. Optional, stainless steel. Specify when ordering. > < Two standard, tear-drop style. > < Decontamination shelf on rear wall. > < Standard, hinged door cover with safety interlock. > < ebmpapst centrifugal fan. > < 120V, 60Hz or 220V, 50Hz voltages available. Specify when ordering. Other voltage options available. > < Main On/Off switch for fan and lighting. Solid-state fan speed control with RFI filter maintains blower uniformity. UV timer, safety interlock shut-off. > 1 Average airflow measured 6" (150 mm) from filter face. Uniformity is +/- 20%. 2 Camfil Farr filters; HEPA efficiency, 99.99% at 0.3μm. Specifications are subject to change without notice. Air Science 120 6th Street Fort Myers, FL 33907 T/239.489.0024 Toll Free/800.306.0656 F/800.306.0677 www.airscience.com

p:6 Product Options PCR Laminar Flow Cabinets 24 36 48 OPTIONS AND ACCESSORIES Purair Model PCR-24 PCR-36 PCR-48 Base Stand Polypropylene Construction Floor-standing base for cabinet. Available with leveling feet or locking casters. Optional motorized height adjustment. Cabinets are available in all polypropylene construction. Contact Air Science for information. P5-CART P15-CART P20-CART PCR-24-PP PCR-36-PP PCR-48-PP ULPA Filter ULPA filter efficiency 99.999% at particle sizes between 0.1 to 0.3μm. PCR-24-ULPA PCR-36-ULPA PCR-48-ULPA Work Surface Optional stainless steel work surface available. SS-TRAY-P5-24 SS-TRAY-P5-36 SS-TRAY-P5-48 Monitair Controller Microprocessor controller monitors cabinet operating procedures, airflow, UV and filter condition. Emits audio and visual alerts if conditions become unsafe. MON-P MON-P MON-P STANDARDS AND COMPLIANCE Quality Management Systems ISO 9001:2008 Environment ISO 14001:2004 ENERGY STAR Partner Cabinet Performance IEST-RP-CC002.2 AS 2252.6 Air Quality ISO 14644-1, Class 4 Filtration Electrical Safety IEST-RP-CC034.1 IEST-RP-CC001.3 IEST-RP-CC007.1 EN 1822 UL-C-61010-1 CE Mark RoHS Exempt under EEE Category 9 120 6th Street Fort Myers, FL 33907 T/239.489.0024 Toll Free/800.306.0656 F/800.306.0677 www.airscience.com 2016 Air Science OW 10243 06/16 Air Science, Purair, Multiplex, and EFT are all registered trademarks of Air Science Corporation