ENGINEERING STANDARDA FOR FIRE FIGHTING HOSE BOX AND SHELTER FIRST EDITION APRIL 2015

Similar documents
ENGINEERING STANDARDA FOR FIRE FIGHTING HOSE BOX AND / OR SHELTER ORIGINAL EDITION NOV. 1993

ENGINEERING STANDARD FOR FIRE STATIONS ORIGINAL EDITION NOV. 1993

STANDARD FOR TRAINING FACILITIES AND FIRE FIGHTERS QUALIFICATIONS FIRST EDITION MAY 2015

STANDARD FOR INSTALLATION, INSPECTION AND TESTING OF FIRE FIGHTING FIXED SYSTEMS FIRST EDITION AUGUST 2015

MATERIAL AND EQUIPMENT STANDARD FOR FIRE-FIGHTING VESSELS ORIGINAL EDITION MAR. 1996


GENERAL STANDARD FOR SAFETY AND FIRE TRAINING CENTERS, FIRE STATION FACILITIES DEC. 1997

AS Australian Standard. Portable fire extinguishers Guide to servicing. This is a free 7 page sample. Access the full version online.

Australian Standard. Fire hydrant installations. Part 1: System design, installation and commissioning AS

GENERAL STANDARD FOR GAS DETECTORS ORIGINAL EDITION MAY 1997

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD

ENGINEERING STANDARD FOR FIRE FIGHTING VESSELS ORIGINAL EDITION JULY 1995

GENERAL STANDARD FOR FIRST EDITION JANUARY 2016

Fire. IMO fire control signs - according to IMO Resolution A.654 (16) (mm) 150x x200

RULES 1978 UNDERGROUND COAL MINES FIRE PRECAUTIONS

ISO/TS TECHNICAL SPECIFICATION. Fire protection Portable and wheeled fire extinguishers Part 2: Inspection and maintenance

DIMENSIONAL STANDARD FOR 1/4" QUICK CONNECT COUPLER PLUGS AND SOCKETS FOR PORTABLE PRESSURE WASHERS

ENGINEERING STANDARD FOR PROCESS DESIGN OF COMPRESSED AIR SYSTEMS ORIGINAL EDITION NOV. 1993

ISO INTERNATIONAL STANDARD

AS/NZS :2008

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

Australian Standard. Gaseous fire extinguishing systems AS (Incorporating Amendment No. 1) AS

DIMENSIONAL STANDARD FOR M22 THREAD CONNECT COUPLER RECEPTACLES AND PLUG COLLARS FOR PORTABLE PRESSURE WASHERS

Australian Standard. Automatic fire detection and alarm systems System design, installation, and commissioning AS

AS/NZS :2016

FIRE APPARATUS DRIVER/OPERATOR - FIRE PUMP

AS/NZS 3133:2008 AS/NZS

AS/NZS :2016. Refrigerating systems and heat pumps Safety and environmental requirements AS/NZS :2016. Part 3: Installation site

ADDISON COUNTY FIREFIGHTERS ASSOCIATION MUTUAL AID SYSTEM STANDARD OPERATING GUIDELINES

Hiren Industrial Corporation

Western Michigan University Facilities Management Engineering Division

ISO INTERNATIONAL STANDARD

Bold items are particular to the City of Euless

ISO INTERNATIONAL STANDARD. Fire protection Automatic sprinkler systems Part 11: Requirements and test methods for pipe hangers

AS/NZS :2014

ISO Clean Version of Revised Working Draft (N 348)

CHAPTER 05 - OFFICE OF STATE FIRE MARSHAL SUBCHAPTER 05A - FIRE AND RESCUE SECTION.0900 PUBLIC PROTECTION CLASSIFICATIONS FOR FIRE DISTRICTS

CHAPTER 61G15-32 RESPONSIBILITY RULES OF PROFESSIONAL ENGINEERS CONCERNING THE DESIGN OF FIRE PROTECTION SYSTEMS

ISO 6183 INTERNATIONAL STANDARD. Fire protection equipment Carbon dioxide extinguishing systems for use on premises Design and installation

Australian Standard. Water mist fire protection systems System design, installation and commissioning AS

AS/NZS IEC 62560:2014

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 6

GRAPHICAL SYMBOLS FOR FIRE PROTECTION DRAWINGS

Australian/New Zealand Standard

GASTEC QA. Approval Requirements 31-1

IMO. Resolution A.952(23) Adopted on 5 December 2003 (Agenda item 17) GRAPHICAL SYMBOLS FOR SHIPBOARD FIRE CONTROL PLANS

STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES

ISO INTERNATIONAL STANDARD. Essential oils Analysis by gas chromatography on chiral capillary columns General method

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

Technical Information

Fire Protection System Contractors and Systems. Submission of the Application for a Water-Based Fire Protection Inspector

Fire detection and alarm systems. Part 4: Power supply equipment (ISO :2003, MOD) AS (Incorporating Amendment No.

Public Input No. 4-NFPA [ Section No. 4.2 ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition.

AS/NZS 3190:2011 AS/NZS

This document is a preview generated by EVS

ARTICLE 25. FUEL GAS CODE

Table OUT OF SERVICE. Building Fire Video 1/15/ Inspection, testing and maintenance. Standards Further Referenced by FCNYS

GASTEC QA. Approval Requirements 31-2

This document is a preview generated by EVS

Australian Standard. Fire protection for mobile and transportable equipment AS AS

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

DRAFT COMBINED POSTAL BALLOT/ AUSTRALIAN / NEW ZEALAND STANDARD FOR COMMENT

This document is a preview generated by EVS

AS/NZS 4821:2014. Protective footwear for firefighters Requirements and test methods AS/NZS 4821:2014. Australian/New Zealand Standard

ISO Textiles Domestic washing and drying procedures for textile testing

FIRE SERVICE FEATURES

AS/NZS :2015

Capital Projects Group Fire Extinguishers Specification

TECHNICAL ALERT No

SOUTH AFRICAN NATIONAL STANDARD

ISO 3999 INTERNATIONAL STANDARD. Radiation protection Apparatus for industrial gamma radiography Specifications for performance, design and tests

AS/NZS IEC :2013

ISO Safety of machinery Laser processing machines Part 1: General safety requirements

INTERNATIONAL STANDARD

ISO Plastics Film and sheeting Determination of water vapour transmission rate Infrared detection sensor method

This is a preview - click here to buy the full publication

NATIONAL COMPETENCY STANDARD

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 21: Particular requirements Rigid conduit systems

Australian/New Zealand Standard

SOUTH AFRICAN NATIONAL STANDARD

Tire Storage. Michigan Fire Inspectors Society Fall Conference

INTERNATIONAL STANDARD

Australian/New Zealand Standard

Substations and high voltage installations exceeding 1 kv a.c.

ISO/TS TECHNICAL SPECIFICATION

AS/NZS :2014

FIRE ALARM PRE-INSPECTION CHECKLIST 1. REFER TO CHAPTER 10 OF CURRENT STATE ADOPTED NFPA 72, FOR INSPECTION, TESTING AND MAINTENANCE PROCEDURES.

ISO INTERNATIONAL STANDARD. Safety of machinery Laser processing machines Part 1: General safety requirements

INTERNATIONAL STANDARD

Australian Standard. Fixed fire protection installations Pumpset systems AS AS 2941

SOUTH AFRICAN NATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

Resolution A.1116(30) Adopted on 5 December 2017 ESCAPE ROUTE SIGNS AND EQUIPMENT LOCATION MARKINGS

This document is a preview generated by EVS

SOUTH AFRICAN NATIONAL STANDARD

This guide is intended to provide assistance in the application of the fire code in all areas served by Tualatin Valley Fire & Rescue.

Transcription:

ENGINEERING STANDARDA FOR FIRE FIGHTING HOSE BOX AND SHELTER FIRST EDITION APRIL 2015 This Standard is the property of Iranian Ministry of Petroleum. All rights are reserved to the owner. Neither whole nor any part of this document may be disclosed to any third party, reproduced, stored in any retrieval system or transmitted in any form or by any means without the prior written consent of the Iranian Ministry of Petroleum.

FOREWORD The Iranian Petroleum Standards (IPS) reflect the views of the Iranian Ministry of Petroleum and are intended for use in the oil and gas production facilities, oil refineries, chemical and petrochemical plants, gas handling and processing installations and other such facilities. IPS are based on internationally acceptable standards and include selections from the items stipulated in the referenced standards. They are also supplemented by additional requirements and/or modifications based on the experience acquired by the Iranian Petroleum Industry and the local market availability. The options which are not specified in the text of the standards are itemized in data sheet/s, so that, the user can select his appropriate preferences therein. The IPS standards are therefore expected to be sufficiently flexible so that the users can adapt these standards to their requirements. However, they may not cover every requirement of each project. For such cases, an addendum to IPS Standard shall be prepared by the user which elaborates the particular requirements of the user. This addendum together with the relevant IPS shall form the job specification for the specific project or work. The IPS is reviewed and up-dated approximately every five years. Each standards are subject to amendment or withdrawal, if required, thus the latest edition of IPS shall be applicable The users of IPS are therefore requested to send their views and comments, including any addendum prepared for particular cases to the following address. These comments and recommendations will be reviewed by the relevant technical committee and in case of approval will be incorporated in the next revision of the standard. Standards and Research department No.17, Street14, North kheradmand Karimkhan Avenue, Tehran, Iran. Postal Code- 1585886851 Tel: 88810459-60 & 66153055 Fax: 88810462 Email: Standards@ nioc.ir

GENERAL DEFINITIONS Throughout this Standard the following definitions shall apply. COMPANY : Refers to one of the related and/or affiliated companies of the Iranian Ministry of Petroleum such as National Iranian Oil Company, National Iranian Gas Company, National Petrochemical Company and National Iranian Oil Refinery And Distribution Company. PURCHASER : Means the Company" where this standard is a part of direct purchaser order by the Company, and the Contractor where this Standard is a part of contract document. VENDOR AND SUPPLIER: Refers to firm or person who will supply and/or fabricate the equipment or material. CONTRACTOR: Refers to the persons, firm or company whose tender has been accepted by the company. EXECUTOR : Executor is the party which carries out all or part of construction and/or commissioning for the project. INSPECTOR : The Inspector referred to in this Standard is a person/persons or a body appointed in writing by the company for the inspection of fabrication and installation work. SHALL: Is used where a provision is mandatory. SHOULD: Is used where a provision is advisory only. WILL: Is normally used in connection with the action by the Company rather than by a contractor, supplier or vendor. MAY: Is used where a provision is completely discretionary.

CONTENTS: PAGE No. 0. INTRODUCTION... 2 1. SCOPE... 3 2. REFERENCES... 3 3. DEFINITION AND TERMINOLOGY... 3 4. UNITS... 4 5. GENERAL REQUIREMENTS... 4 6. LOCATION... 4 7. CONSTRUCTION... 4 7.1 Size and Arrangement... 4 7.2 Marking... 4 7.3 Equipment-General... 5 8. NUMBER OF HOSE BOXES /SHELTERS... 5 9. DOMESTIC SERVICE USE PROHIBITED... 6 10. FIRE POINTS... 6 APPENDICES: APPENDIX A TYPICAL FIRE HOSE BOX AND INCLUDED ACCESSORIES... 7 1

0. INTRODUCTION "Fire Fighting and Fire Protection Systems" are broad and contain variable subjects of paramount importance therefore a group of engineering standards are prepared to cover the subject. This group includes the following standards: STANDARD CODE IPS-E-SF-120 IPS-E-SF-140 IPS-E-SF-160 IPS-E-SF-180 IPS-E-SF-200 IPS-E-SF-220 IPS-G-SF-240 IPS-E-SF-260 IPS-E-SF-300 IPS-E-SF-340 IPS-E-GN-100 STANDARD TITLE "Engineering Standard for Off-Shore Installation Fire Fighting & Fire Protection" "Engineering Standard for Foam Generating and Proportioning Systems" "Engineering Standard for CO 2 Gas Fire Extinguishing Systems" "Engineering Standard for Dry Chemical Fire Extinguishing Systems" "Engineering Standard for Fire Fighting Sprinkler Systems "Engineering Standard for Fire Water Distribution and Storage Facilities" "General Standard for Fire Fighting Pump Systems & Trailers" "Engineering Standard for Automatic Detectors and Fire Alarm Systems" "Engineering Standard for Application of Breathing Apparatus in Safety and Fire Fighting" "Engineering Standard for Fire Fighting Hose Box and Shelter" "Engineering Standard for Units" This Standard covers: "Engineering Standard for Fire Fighting Hose Box and Shelter" 2

1. SCOPE This Standard is prepared to cover minimum requirement of an enclosure to accommodate fire hoses, water and foam branch pipes, containers of foam compound, coupling spanners, collecting/dividing breechings with adaptors and other ancillary piece of equipment. Note: This standard specification is reviewed and updated by the relevant technical committee on May. 2000. The approved modifications by T.C. were sent to IPS users as amendment No. 1 by circular No 107 on May. 2000. These modifications are included in the present issue of IPS. Note 2: This is a revised version of this standard, which is issued as revision (1)-2015. Revision (0)- 1993 of the said standard specification is withdrawn. 2. REFERENCES Throughout this Standard the following dated and undated standards/codes are referred to. These referenced documents shall, to the extent specified herein, form a part of this standard. For dated references, the edition cited applies. The applicability of changes in dated references that occur after the cited date shall be mutually agreed upon by the Company and the Vendor. For undated references, the latest edition of the referenced documents (including any supplements and amendments) applies. NFPA (NATIONAL FIRE CODES) NFPA-24 "Standard for the Installation of Private Fire Service Mains and Their Appurtenances" NFPA-14 "Standard for Installation Stand Pipe and Hose System" IPS (IRANIAN PETROLEUM STANDARDS) IPS-M-SF-105 "Material and Equipment Standard for Valves, Reels, Hoses, Nozzles and Monitors for Fire Fighting" 3. DEFINITION AND TERMINOLOGY 3.1 Hose Box An enclosure located over or adjacent to a hydrant or other water supply designed to contain the necessary hose nozzles, hose wrenches, gaskets, and spanners to be used in fire fighting in conjunction with and to provide aid to the local fire department. 3.2 Shelter A shed for keeping fire hoses and other fire fighting equipment. They shall be equipped with lighting and wooden shelves. 3

4. UNITS This standard is based on international system of units (SI), as per IPS-E-GN-100 except where otherwise specified. 5. GENERAL REQUIREMENTS 5.1 To protect fire hoses and miscellaneous tools and devices from direct sun, dust, rain, hot and cold weather, etc. an enclosure should be designed to accommodate the equipment. Fire hoses should be coupled together and installed in such a manner as they could be pulled out immediately by fire fighters to the scene of fire without lapse of time. 5.2 A supply of hose and equipment shall be provided where hydrants are intended for use by plant personnel or a fire brigade. 5.2.1 The quantity and type of hose and equipment shall depend on the following: 1) Number and location of hydrants relative to the protected property. 2) Extent of the hazard 3) Fire-fighting capabilities of potential sers. 5.2.2 The authority having jurisdiction shall be consulted regarding quantity and type of hose. 5.3 Hose shall be stored so it is accessible and is protected from the weather by storing in hose houses or by placing hose reels or hose carriers in weatherproof enclosures. Hoses and hose connections shall confirm to IPS-M-SF-105. 6. LOCATION 6.1 Outdoor hose boxes will be located in plant process area, utility areas and offsite areas, so that at least one unit, shall be available for every 2 hydrants. 6.2 When hose carriers are used, they shall be located so that the hose shall be brought quickly into use at a hydrant. 6.3 When hose boxes or shelters are located over hydrants, it is good practice to have two or three lengths of hoses connected together and attached to the hydrant ready for use. 7. CONSTRUCTION Hose boxes or shelters shall be of substantial construction on adequate foundations. The construction shall be such as to protect the hose from weather and vermin and designed so that hose lines can be quickly brought into use. Clearance shall be provided for proper operation of the hydrant wrench. Proper ventilation shall be provided. The exterior shall be painted or otherwise suitably protected against deterioration. 7.1 Size and Arrangement Hose box or shelter shall be of adequate size and arrangement to provide shelves or racks for the hose and equipment. For equipment details of hose boxes or shelters, see Clause 7.3. 7.2 Marking Hose boxes and shelters shall be plainly identified. 4

7.3 Equipment-General 7.3.1 Hose box When hose box are used, each shall be equipped as a minimum with the following equipment: a) 4 branches fire hoses; b) 2 water nozzles, (jet/fog/stop); c) 1 foam branch pipe; d) 1 in line inductor plus pick-up tube; e) 1 collecting and 1 dividing breeching; f) 2 hose coupling gaskets for each size hose; g) 1 Hydrant wrench; h) Optional equipment to be included in an enclosure are as follow: 1) Fire axe with brackets; 2) Crow bar with brackets; 3) Hose and ladder straps. Typical fire hose box and included accessories indicated at Appendix A. 7.3.2 Shelter When shelter are used, each shall be equipped as a minimum with the following equipment: a) 10 branches fire hoses; b) 2 pieces water nozzles, ( jet/fog/stop); c) 2 pieces foam branch pipe; d) 2 in line inductor plus pick-up tube; e) 5 PVC barrel containers each with 100 liters of foam compound. Type of foam compound will depend on the equipment and area to be protected; f) 1 pieces collecting and 1 dividing breechings; g) 4 hose coupling gaskets for each size hose; h) 2 Hydrant wrench i) 2 wheeled dry power fire extinguisher (50/75 kg); j) 4 portable dry powder fire extinguisher (30 kg); k) 2 barrel wrench; l) Optional equipment to be included in an enclosure are as follow: 1) Fire axe with brackets; 2) Crow bar with brackets; 3) Hose and ladder straps. 7.3.3 All of the above mentioned equipment and accessories shall confirm to with IPS-M-SF-105. 8. NUMBER OF HOSE BOXES /SHELTERS The number of hose boxes /shelters and their contents, shall be indicated on the list prepared for each project and they shall be shown on an appropriate layout drawing. 5

9. DOMESTIC SERVICE USE PROHIBITED The use of hydrants and hoses for purposes other than fire-related services shall be prohibited. 10. FIRE POINTS Fire points, containing portable and wheeled type extinguishers, shall be provided in and around processing areas, either separately or in combination with hose boxes or shelters. 6

APPENDICES APPENDIX A TYPICAL FIRE HOSE BOX AND INCLUDED ACCESSORIES 7