FUMEGUARD TM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED LOW SMOKE HALOGEN FREE CABLES

Similar documents
GUARDIANTM QUALITY APPROVED CABLES. Cables Limited MADE IN IRELAND SINCE 1934 IDH CABLES LIMITED MECHANICALLY PROTECTED CABLES

LSOH Flexible Cables

CONTENTS. Introduction Customer Service BS codes of practice BS Fire Performance Cable Selection Guide... 7

Photovoltaic Cables EN H1Z2Z2-K

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Traction Cable Radox 3 GKW

LSOH Wiring Cables. LSOH Conduit Wire (HO7Z-R) Low Voltage (450/750 V) Cable Approvals. Key Applications. Conductor. Insulation. Core Identification

Fire Resistant Cables

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

FIRE RESISTANT CABLES FP300

BS /1000V XLPE Insulation LSZH Sheath Cables

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

FIRE RESISTANT CABLES FP200 GOLD

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

fire resistant cables

FIRE RESISTANT CABLES FP200 GOLD

FIRE RESISTANT CABLES FP PLUS. New Generation. Now with enhanced Insudite TM insulation

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

THE TRUE FIRE SURVIVAL CABLE

FIRE RESISTANT CABLES FP400

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Flame Retardant Overall Screened Instrumentation Cables (multicore)

WORLDWIDE CABLE EXPERTS

Total Fire Solutions. Includes BS 8519 and the updated BS :

The Quality Connection. BETAflam Fire Resistant Safety Cables

High Performance LSZH Fire Resistant Cable

PolyOne is a global polymer solutions provider with the ability to meet regulatory and product

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

Havells Fire Survival Cables

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

Cable technology for highest safety requirements

PERFORMANCE POLYMER SOLUTIONS

Selecting the AFUMEX range guarantees quality and offers the widest choice and the greatest safety.

Introduction.

PRODUCT CATALOGUE Norröna

Tratos Railway Cables

Catalogue Power Cables

The safe choice. Now real safety is possible and easy. The evolution of safety. Fire resistant LSOH cables. Ecology Line. Traditional standard cables

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Catalogue Telecommunication Cables INTRODUCCIÓN

FIRE RESISTANT CABLES

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Electrical test. Determining resistance of conductors by means of using DC four-wire connection measurement

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

HELKAMA. Optical Fibre Cables

The world s most trusted cable brand

Corporate Presentation. 14 June 2009

CLEARING MISCONCEPTIONS ABOUT LOW-SMOKE, HALOGEN-FREE CABLES

Low Voltage Catalogue_Final ai 11/8/09 11:37:27 AM BICC 1 BICC Final Brochure-NEW.indd 1 7/5/10 3:02 PM

Lloyd s Register Type Approval System Test Specification Number 3

The world s most trusted cable brand

Nuclear Power Plant LSZH Cable Overview

All Prysmian FP400 cables are manufactured under an ISO 9001 Quality System certified by BASEC and LPCB.

System Circuit integrity in the event of fire. Safety cables and systems from a pro. Cabling Solutions

CABLEPACK & EXZHELLENT TRIPLAN. Easy installation

Engineering opportunities. 16 th March 2006

LV FIRE RESISTANT CABLES

STANDARDS INSTALLATION. Certificate No 077m

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

Dryflex FLAM. Halogen-Free Flame Retardant TPEs

Wires, Cables, Cords and Adhesive Tapes

CATEGORY 6A FTP RJ45 SOLUTION

OIL & GAS INDUSTRY OTHER INDUSTRIES

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

DNVGL-CP-0401 Edition February 2016

LSZH Zero Halogen Cables

INTERNATIONAL STANDARD

Mauritian Standards/Amendments Published in 2013

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Cablosam Tapes for Fire-Resistant Cables

13. UNITED KINGDOM Standards Supply Voltage and Plug Configurations 247

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

INTERNATIONAL STANDARD

WHAT MAKES PRYSMIAN CABLES DIFFERENT?

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

Multi-Core Fire Resistant Cable

Telecommunication Cables

SUMEDD03 Endorse the Positioning, Fixing and Fitting of Electrical Wiring Systems, Wiring Enclosures, Equipment and

UNIKA Universal Cable Cable Specialist

RAIL /// WIRE & CABLE WHERE THE BEST IDEAS IN RAIL BEGIN

Single core cables with reduced wall thickness

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

DNVGL-CP-0399 Edition March 2016

Forming the Future. Changing spaces with architectural cladding and interior theming

flexible conduit solutions for rail THE POWER IN CABLE MANAGEMENT

Special Provision No. 683S28 December 2017

Caledonian Flame Retardant Coaxial Cables

Transcription:

Cables Limited MADE IN IRELAND SINCE 1934 QUALITY APPROVED CABLES IDH CABLES LIMITED FUMEGUARD TM LOW SMOKE HALOGEN FREE CABLES The longest-running original range of low voltage, low smoke, halogen free cables in the industry

ABOUT IDH IDH CABLES LIMITED IS IRELAND S ONLY ELECTRICAL CABLE MANUFACTURER. ALL OUR CABLES ARE STRINGENTLY TESTED AND APPROVED TO THE HIGHEST STANDARDS. QUALITY IS IN OUR CULTURE. IDH Cables Limited (formerly Irish Driver-Harris) was the first manufacturer in Ireland to receive BS 5750 Approval which forms the basis for the longest running manufacturing ISO approval in the country. We have been the cable manufacturer and supplier of choice for many of the world s most prestigious building and renovation projects. These include Canary Wharf in London; the Dubai Metro; the Burj Al Arab, Dubai; the Titanic Quarter in Belfast; Hong Kong s Science Park; the world famous Wembley Stadium and Ascot Racecourse in the UK; Croke Park in Dublin; Soldier Field; the McCormick Convention Centre in Chicago; London s Millennium Dome; and the Grand Lisboa Hotel in Macau. Soldier Field, Chicago Croke Park, Dublin Ascot Racecourse, UK

OVERVIEW Fumeguard TM is a complete range of low voltage cables made to the highest standards in low smoke halogen free (LSHF) materials. Cables include single for conduit and panel wiring; flat multicores for fixed wiring and flexible cables for appliances, for ordinary duty, heat resisting and low temperature (Arctic) use. Fumeguard TM cables are fire safety tested to: SMOKE EMISSION: BS EN 61034 IEC 61034-2 FLAME RETARDANT: BS EN 60332-1-2 ACID GAS EMISSION: BS EN 50267-2-1 IEC 60754-1 DEGREE OF ACIDITY EMISSIONS: BS EN 50267-2-3 IEC 60754-2 Fumeguard TM cables are manufactured to meet the latest versions of cable standards. BS 7211: 2012 BS EN 50525-3-41 BS EN 50525-3-11 Specifiers can rely on the Fumeguard TM name as it complies fully with International (IEC) and British Standards (BS). Not all cables are fire safety compliant to these standards despite being promoted as so. Modified PVCs and LSF materials do not comply with the highest standards. Created as a result of the King s Cross tube fire in London, the low smoke halogen free polymer technology reduces smoke when burning to improve visibility in a fire and does not emit the poisonous HCL fumes that are generated by PVC and modified PVC cables. All public buildings, stadia, railway stations and enclosed construction spaces should call for LSHF cables. Canary Wharf, London Millennium Dome, London Burj Al Arab, Dubai

NO7ZZ1-R,U & NO5ZZ1-R,U 6181B; 6241B; 6242B; and 6243B INSULATED & SHEATHED CABLES Used for surface wiring in power and lighting applications. Sheath has UV protection against direct sunlight. STANDARDS: OPERATING TEMP: APPROVALS: BS7211 90 O C White as standard. Other colours available on request, including red BASEC Strip Easy version Conductor mm 2 Conductor Construction 1 Core / 6181B 2 Core / 6242B 3 Core / 6243B Conductor Resistance ohm/km @20 o C 1.0 1 / 1.30 4.10 4.10 x 8.65 4.60 x 9.70 18.10 1.5 1 / 1.37 4.45 4.55 x 8.80 4.75 x 11.45 12.10 2.5 1 / 1.77 5.05 5.40 x 10.50 5.46 x 13.40 7.41 4.0 7 / 5 6.05 6.10 x 12.00 4.61 6.0 7 / 1.04 6.60 6.90 x 13.80 3.08 10.0 7 / 1.35 7.90 8.40 x 18.50 1.83 16.0 7 / 1.70 9.10 9.70 x 20 1.15 ALSO AVAILABLE IN TRADITIONAL FLAT STYLE HO5Z-R,U & HO7Z-R,U 6491B SINGLE CORE INSULATED CABLES General purpose power and lighting cables, often used within protective conduit or trunking installations. Can also be used within light fittings, appliance wiring and control gear. STANDARDS: OPERATING TEMP: CORES: APPROVALS: BS EN 50525-3-41; BS7211 90 O C Blue, Brown, Black, Grey; Green/Yellow. Other colours available on request Single BASEC Conductor mm 2 Conductor Construction Conductor Resistance ohm/km @20 o C 1.0 1 / 1.30 2.35 18.10 1.5 x 7 7 / 0.53 3.00 12.10 2.5 x 7 7 / 7 3.60 7.41 4.0 7 / 5 4.10 4.61 6.0 7 / 1.04 4.70 3.08 10.0 7 / 1.35 6.00 1.83 16.0 7 / 1.70 7.00 1.50 25.0 7 / 2.14 8.70 0.727 TECHNICAL DATA INSULATION RESISTANCE K VALUE 0.037M ohms/km at 90 O C TENSILE STRENGTH (MIN) 10.0 N/mm 2 % ELONGATION (MIN) 125% HOT SET ELONGATION 100% LOW TEMPERATURE BEND -15 O C VOLTAGE TEST (20OC) Pass 2.5 KV TEST UNDER FIRE CONDITIONS BS EN 60332 CORROSIVE ACID GAS EMISSIONS <0.5% to BS EN 50267 SMOKE EMISSION Pass BS EN 61034

HO5Z-K & HO7Z-K 2491B SINGLE CORE INSULATED WIRES Flexible single core wires used typically in control panels. STANDARDS: BS EN 50525-3-41 OPERATING TEMP: CORES: APPROVALS: 90 O C Blue, Brown, Black, Grey, Green/Yellow. Other colours available on request Single BASEC Conductor mm 2 Conductor Construction Conductor Resistance ohm/km @20 o C 0.5 16 / 0.20 2.12 39.00 0.75 24 / 0.20 2.33 26.00 1.0 1/1.13 2.48 19.50 1.5 30 / 0.25 2.98 13.30 2.5 50 / 0.25 3.63 7.98 4.0 56 / 0.25 4.23 4.95 6.0 84 / 0.30 4.83 3.30 10.0 80 / 0.40 5.85 1.91 TECHNICAL DATA INSULATION RESISTANCE K VALUE 0.037M ohms/km at 90 O C TENSILE STRENGTH (MIN) 10.0 N/mm 2 % ELONGATION (MIN) 125% HOT SET ELONGATION (200 O C MAX) 100% LOW TEMPERATURE BEND -15 O C VOLTAGE TEST (20OC) Pass 2.5 KV TEST UNDER FIRE CONDITIONS BS EN 60332 CORROSIVE ACID GAS EMISSIONS <0.5% to BS EN 50267 SMOKE EMISSION Pass BS EN 61034 ARCTIC -40 O C LOW SMOKE HALOGEN FREE FLEXIBLE CABLES Insulated and flexible cords used for extension leads and temporary wiring. OPERATING TEMP: CORES: 90 O C Yellow and Blue sheath. Other colours available on request 2 Core Brown and Blue; 3 Core Blue, Brown and Green/Yellow Conductor mm 2 Conductor Construction 2 Core 3 Core 4 Core 5 Core Conductor Resistance ohm/km @20oc 0.75 24 / 0.20 6.50 6.70 7.60 8.60 26.00 1.0 1/1.13 6.80 7.05 8.15 9.40 19.50 1.25 40 / 0.20 7.50 8.05 15.60 1.5 30 / 0.25 7.80 8.25 9.60 10 13.30 2.5 50 / 0.25 9.25 10.20 11.30 7.98 4.0 56 / 0.30 11.50 12.50 4.95 ALSO AVAILABLE IN TWIN FLAT FOR FESTOON LIGHTING INSULATION MADE WITH LOW SMOKE ZERO HALOGEN THERMOPLASTIC MATERIAL (TYPE T16) CONDUCTOR RESISTANCE: As per BS60228 INSULATION THICKNESS: As per BS6004 Table 6 INSULATION RESISTANCE (MIN): 0.02M ohms/km at 70 O C TENSILE STRENGTH (MIN): 7.5 N/mm 2 % ELONGATION (MIN): 150% FLAME TEST: BS EN 60332 SMOKE EMISSION: As per BS7211 CORROSIVE ACID GAS EMISSIONS: <0.5% to BS EN 50267 VOLTAGE TEST: Pass 2.5 KV at 20 O C SHEATHING MADE WITH LOW SMOKE ZERO HALOGEN THERMOPLASTIC MATERIAL (TYPE TM7 TO HD21.14S1) SHEATH THICKNESS: As per BS6004 Table 6 CABLE OD: As per BS6004 Table 6 TENSILE STRENGTH (MIN): 7.5 N/mm 2 % ELONGATION (MIN): 150% RESISTANCE TEST: 0.02M ohms/km at 70 O C CORROSIVE ACID GAS EMISSIONS: <0.5% to BS EN 50267 TEST UNDER FIRE CONDITIONS: BS EN 60332

HO5Z1Z1-F 3182B; 3183B; 3184B AND 3185B INSULATED & SHEATHED FLEXIBLE CORDS General purpose 70 O C rated flexible cable. Manufactured to BS EN 50525-3-11. Flexible cables with halogen free thermoplastic insulation and low smoke emissions. Includes circular and flat cables with voltage rating up to and including 300/500V. Intended for connecting domestic appliances to a fixed supply. 90 O C version also available. STANDARDS: BS EN 50525-3-11 OPERATING TEMP: 70 O C White as standard. Other colours available on request CORES: 2 Core- Blue and Brown. 3 Core - Blue, Brown, Green/Yellow No. of nominal crosssectional areas of conductor mm 2 Thickness of insulations Specified value mm Thickness of insulations Specified value mm Lower Limit Upper Limit Min. insulation resistance at 70 O C 2x0.75 5.7 or 3.7x6.0 7.2 or 4.5x7.2 0.011 2x1 5.9 or 3.9x6.2 7.5 or 4.7x7.5 2x1.5 0.7 6.8 8.6 2x2.5 1.0 8.4 1 0.0095 2x4 1.1 9.7 12.1 0.0078 3x0.75 6.0 7.6 0.011 3x1 6.3 8.0 3x1.5 0.7 0.9 7.4 9.4 3x2.5 1.1 9.2 11.4 0.0095 3x4 1.2 10.5 13.1 0.0078 4x0.75 6.6 8.3 0.011 4x1 0.9 7.1 9.0 4x1.5 0.7 1.0 8.4 10.5 4x2.5 1.1 10.1 12.5 0.0095 5x0.75 0.9 7.4 9.3 0.011 5x1 0.9 7.8 9.8 5 x1.5 0.7 1.1 9.3 11.6 5x2.5 1.2 11.2 13.9 0.0095 INSULATION MADE WITH LOW SMOKE ZERO HALOGEN THERMOPLASTIC MATERIAL (TYPE T16) CONDUCTOR RESISTANCE: As per BS60228 INSULATION THICKNESS: As per BS EN 50525-3-11 INSULATION RESISTANCE (MIN): 0.02M ohms/km at 70 O C TENSILE STRENGTH (MIN): 7.5 N/mm 2 % ELONGATION (MIN): 150% FLAME TEST: BS EN 60332 SMOKE EMISSION: As per BS61034 CORROSIVE ACID GAS EMISSIONS: <0.5% to BS EN 50267 VOLTAGE TEST: Pass 2.5 KV at 20 O C SHEATHING MADE WITH LOW SMOKE ZERO HALOGEN THERMOPLASTIC MATERIAL (TYPE TM7) SHEATH THICKNESS: As per BS EN 50525-3-11 CABLE OD: As per BS EN 50525-3-11 TENSILE STRENGTH (MIN): 10.0 N/mm 2 % ELONGATION (MIN): 150% RESISTANCE TEST: 0.02M ohms/km at 70 O C OXYGEN INDEX: 35% at 270 O C CORROSIVE ACID GAS EMISSIONS: <0.5% to BS EN 50267 TEST UNDER FIRE CONDITIONS: BS EN 60332

OTHER IDH PRODUCTS TM KILFLAM FIRE RESISTANT CABLES TM GUARDIAN MECHANICALLY PROTECTED CABLES KILFLAM HIGH PERFORMANCE FIRE RESISTANT CABLES Single core conduit wire and multi-core cables available in standard and enhanced grades. GUARDIAN The lightweight, easy to install, connect and protect cable system TM PVC CABLES INSULATED PVC CABLES PVC CABLES Standard, heat resisting and low temperature types

Soldier Field Stadium in Chicago, the Savoy Hotel London, the Dubai Metro and the Galway Clinic in Ireland just some of the projects that have chosen IDH Cables. All our cables are manufactured with materials which are compliant with RoHS and WEEE directives. IDH Cables Limited Phone 00 353 (0) 51 421 405 Fax 00 353 (0) 51 421 927 Email sales@idh.ie Web www.idh.ie