Combustible Gas Leak Detector Instruction Manual

Similar documents
Combustible Gas Leak Detector Instruction Manual

CD100A COMBUSTIBLE GAS DETECTOR

Model GD Instruction Manual. Combustible Gas Leak Detector. reedinstruments. www. com

Instruction Manual MSI Sensit HXG

SENSIT HXG-2. Instruction Manual For use with combustible gases Gas Leak Detector

LS1. Operator Manual. Kane International Ltd

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

LD910. User Manual. Combustible Gas Leak Detector. Detects all Hydrocarbon and other Combustible Gases. Made in U.S.A. MSHA Approved Intrinsic Safety

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

Single Gas Monitor 777

INSTRUCTION MANUAL GAS LEAK DETECTOR CD200

SENSIT HXG-2d Combustible Gas Detector

INSTRUCTION MANUAL CD Fax: (503)

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Digital Salt / TDS Meter. 390a. The Value Leader TM

Installation and Wiring 1.

III. 99 Washington Street Melrose, MA Phone Toll Free Visit us at OPERATING INSTRUCTIONS

Combustible Gas Detection and Control System

NGD8800 USER S MANUAL

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

APPLICATION DATA SHEET

PGM100 Carbon Monoxide

SENSIT PROPANE GAS. 4Gas Leak Detectors 4Hazardous Gas Monitors 4Calibration Stations 4Data Management 4Pipe Locators ENERGY INDUSTRIES

testo 316-EX gas leak detector Instruction manual

SENSIT FIRE SERVICE. 4Hazardous Gas Monitors 4Gas Leak Detectors 4Calibration Stations 4Data Management EMERGENCY RESPONSE

Model VFM200. User Manual. Formaldehyde (HCHO or CH 2 0) and Total Volatile Organic Compounds (TVOC) Tester

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

COMBUSTIBLE GAS LEAK DETECTOR PEN

Instruction Manual Eagle Series

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

BST-MG07 Multi-gas Detecting Alarm Manual Instruction

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

SENSIT MUNICIPAL. 4Gas Leak Detectors 4Hazardous Gas Monitors 4Calibration Stations 4Data Management 4Pipe Locators GOVERNMENT SERVICES

ALTAIR 5X Multigas Detector Product Specification

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

PRODUCT GUIDE. Gas Leak Detectors Gas Monitors Pipe & Joint Locators Calibration Stations Data Management MUNICIPAL SERVICES

Operate the Mutli-Gas Monitor PID

GS100M Gas Detection Controller

Technical Reference Guide. 1, 2, 3, and 4-Gas Detector

User Manual. GPD 3000 e. gas detector

SP-220. Features. Combustible handheld gas leakage detector

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

TARGET Series Portable Gas Detector Operation & Maintenance Manual

SENSIT GOLD G2 II 2 G INSTRUCTION MANUAL. Gas Detection Instrument. Read and understand instructions before use.

Refrigerant Leak Detector

ESD3000 ESD200 Combustible / Toxic Gas Detector

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

Operating Instructions Compur Monitox plus

IMR IX176 Portable Gas Detector User Manual

GasAlertMicro 5. 1, 2, 3, 4, and 5 Gas Detectors. Quick Reference Guide

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

SENSIT GOLD G2 INSTRUCTION MANUAL For use with combustible gases and optionally available oxygen and toxic gases.

03 Series: GP-03 Version Operator s Manual

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

GAS-Mate. Combustible Gas Leak Detector

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Gas leak detectors. For a quick overview. testo testo testo testo gas detector testo 316-Ex

RAE Systems Systems. User Presentation. October Protection Through Detection

GasAlertMicroClip X3 Specifications

REFRIGERANT LEAK DETECTOR OPERATIONS MANUAL LD-170

ia d ATEX 100 II 2G D MT 99 ATEX G 001 x EX-METER II Series [ Versatility in Explosive Atmospheres]

UPON COMMENCMENT OF INSTALLATION IT IS OF PARAMOUNT IMPORTANCE THAT THE STEP BY STEP GUIDE (INCLUDED) IS FOLLOWED COMPLETELY

Model GX-2001 Canadian Version Operator s Manual Part Number: RK Revision: 0 Released: 1/17/05

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

Dräger Pac Ex 2. Elegant and smart... Explosive hazards and lack or surplus of oxygen under control

Gas Detection System TOX ALARM DG2000-Garage

Explosion protection Marijan Gorše, dipl. ing.

BW Clip4. Portable Gas Detector. Operator Manual

SGA71. Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG

Gas Detection. - Disposable - Serviceable. Single Gas Detectors

Model LP USER S MANUAL AND INSTALLATION INSTRUCTIONS

Monitores Personales. Personal Monitor

NH 3 RESPONDER Portable Ammonia Leak Detector QUICK REFERENCE GUIDE

MicroRay IR-100 NEW. Inspection MicroRay IR-100

GasAlert. Introduction. WWarning. Table 1. GasAlert Models. Gas Monitored

Model GX-2003 Operator s Manual

Relays for use in hazardous locations. Class I, Division 2 and ATEX

We measure it. testo 316-Ex CH 4 testo 316-1

Gas leak detectors. We measure it. For a quick overview. testo testo testo testo gas detector testo 316-Ex.

User Manual. Single Gas Detector

ESD500. ESD500 Combustible / Toxic Gas Detector

SIL 2. Ultima X Series Gas Monitors CERTIFIED

TOOLS AND INSTRUMENTS

T.ex Single Gas Detector VISA

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

Bacharach Bodyguard 4 User's Guide

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

EVac II Programmable Digital Vacuum Gauge

QUICK REFERENCE GUIDE

Model GP-01 Combustible Gas Monitor Operator s Manual

NH3 RESPONDER PORTABLE AMMONIA LEAK DETECTOR. Quick Reference Guide

GasAlertMicro 5 and GasAlertMicro 5 PID O 2, CO, H 2 S, PH 3, SO 2, Cl 2, NH 3, NO 2, HCN, ClO 2, O 3, VOC, and Combustibles

MULTI-GAS MONITOR. Eastern Energy Co., Ltd. 40/4 Vitoondumri Rd., Banbueng Banbueng, Chonburi, Thailand

Transcription:

721 Combustible Gas Leak Detector Instruction Manual

TABLE OF CONTENTS A. INTRODUCTION 1. Congratulations...3 2. Product Description...3 B. SAFETY CONSIDERATIONS...4 C. TECHNICAL DATA 1. Features and Benefits...5 2. Product Applications...5 3. Specifications...6 D. MEASUREMENT TECHNIQUES 1. Controls and Functions...7 2. Step by Step Procedures:...9 E. ADDITIONAL FEATURES...12 F. TROUBLE SHOOTING GUIDE...15 H. MAINTENANCE...15 I. ACCESSORIES...15 2

A. INTRODUCTION 1. Congratulations!! Thank you for purchasing TPI products. The 721 is easy to use and is built to last. It is backed by a 3 year limited warranty. Please remember to complete and return your product warranty registration card. 2. Product Description The ergonomically designed 721 is a hand-held, combustible gas leak detector. It is capable of finding combustible gas leaks in pipes, fittings, regulators, etc. Additional features include the capability to display %LEL, leak level in ppm, and user adjustable alarm point. The 721 comes complete with the following accessories: Carrying Pouch (A780) Instruction Manual Battery & Sensor (Installed & Calibrated) 3

B. SAFETY CONSIDERATIONS WARNING: Please follow manufacturers test procedures whenever possible. Do not place the sensor cage located on the end of the gooseneck on hot or in hot locations. GENERAL GUIDELINES ALWAYS Turn your detector on in a clean air environment away from the test location. Inspect the sensor cage to ensure it is securely attached. NEVER Place the detector or sensor cage in or on a hot item. 4

C. TECHNICAL DATA 1. Features and Benefits Auto Zero %LEL PPM Mute Automatically sets the sensor to zero at start up. Displays the percentage lower explosive limit (LEL) Displays the amount of leakage in parts per million (ppm) Mutes the speaker and earphone alarm Zero Adjustable Alarm Visual Alarm Auto Off Manually sets the sensor to zero Alarm point can be set as required Alarm LED s located on the front and in the sensor cage tip When enabled, the 721 turns off after approximately 20 minutes to saves battery life. Can be disabled. 2. Product Applications Perform the following tests and/or measurements with the 721 leak detector: Locate combustible gas leaks in joints and fittings. Determine Lower Explosive Limit percentage. Determine the combustible gas leak level in ppm (parts per million). 5

3. Specifications Leak Detection Sensitivity (methane): 10ppm Gases Detected (partial listing): Acetone, Acetylene, Alcohol, Ammonia, Benzene, Butane, Ethanol, Ethylene Oxide, Gasoline, Hexane, Hydrogen, Methane, Naphtha, Natural Gas, Paint Thinners, Propane, Solvents Display Type: Dual display with backlight Display Modes: Real (ppm), Leak Level (stepped ppm), %LEL Ranges: Real ppm: 0 to 9999ppm Stepped ppm: 0, 500, 1000, 3000, 5000, 9999ppm %LEL: 0 to 19.9% Audible Leak Indication: Adjustable tic rate via side thumb wheel Alarm Indication: Visual and audible (User adjustable alarm level) Sensor Test and Zero: Automatic at start up Goose Neck: 16 long with visual alarm indicator in sensor housing Operating Temperature: 32 to 122 (0 to 50) Gooseneck Length: 16 inches Battery Type: C size Alkaline (2) Size: 9.4 x 2.9 x 2.2 (240mm x 74mm x 55mm) Weight: 1 lb (454g) 6

D. MEASUREMENT TECHNIQUES 1. Controls and Functions: Push Buttons Thumb Wheel Short Press: Turns the 721 on. Long Press (3 seconds): Turns the 721 off. Short Press: Silences the alarm. Long Press (3 seconds): Activates Menu Mode. Short Press: Activates sensor zero. Long Press (3 seconds): Turns the backlight on and off. Controls speed of tick rate 7

D. MEASUREMENT TECHNIQUES 1. Controls and Functions (continued): Instrument Layout Sensor cage containing the sensor and visual alarm indicator Speaker Gooseneck On Indicator Earphone Jack Keypad Display Alarm LED Tick adjust wheel 8

D. MEASUREMENT TECHNIQUES 2. Step by Step Procedures: WARNING! Turn the 721 in a clean air environment away from the test area. Failure to do so may cause the 721 to display sensor error and turn off. Measurement Procedure: 1. Turn the 721 on by pressing the key. The 721 will begin a 30 second countdown and wait will display. During this countdown the sensor is being self tested and set to zero. 2. After the countdown is complete the 721 will display 0 and a tic rate will begin. 3. At this point the display mode can be selected. Once the display mode is selected the 721 will turn on in the same mode each time unless changed. If the display mode does not need to be changed, proceed to step 8. 4. To change the display mode press and hold the key for approximately 3 seconds to enter menu mode. The following will be displayed: 5. Press the key to proceed to the display mode screen. 9

Step by Step Procedures (continued): 6. Depending on the last display mode selected one of the following displays will be seen. The display modes can be changed by using the key to cycle between them. REAL mode will display leak levels in ppm (parts per million) LEL % will display leak levels in %LEL (Lower Explosive Limit) 0ppm ud (ud=under) will display leaks in steps. The steps are 0ppm, ud 500ppm, ud 1000ppm, ud 3000ppm, ud 5000ppm, ud 9999ppm 10

Step by Step Procedures (continued): 7. Once the desired display mode is selected, press the key and the following display will be seen: 8. Press the key again to exit menu mode and return to normal operation. 9. Turn the thumbwheel on the side and set a consistent tic rate. If necessary the key can be used to zero the display. Enter the area and begin testing. As a leak is found the tic rate will increase and depending on the display mode selected, the concentration will be displayed on the LCD in ppm, %LEL, or stepped ppm. 10. To locate the source of a leak, use the thumbwheel to nullify the increase in tic rate and move along the pipe, fitting, etc. being tested. 11. Continue to nulify any increases in tic rate and move along the item being tested until the leak source is located. 12. If the leak concentration is above the alarm level the alarm will sound and LED s located in the front panel and sensor cage will flash. 11

E. Additional Features: Alarm Level Adjustment The alarm level can be adjusted by performing the following steps: 1. After the 721 has been turned on and has gone through the warm up period, press and hold the key for approximately 3 seconds to enter menu mode. The following will be displayed: 2. Press the key to proceed to the display mode screen. 3. Press the key to proceed to the alarm adjustment screen. The following will be displayed. 4. Press the key to increase the alarm level or the key to decrease the alarm level. The alarm can be adjusted from 100ppm to 5000ppm in increments of 100ppm. Press the key when finished. 12

Additional Features (continued): Auto Power Off The auto power off feature can be enabled or disabled as required: 1. After the 721 has been turned on and has gone through the warm up period, press and hold the key for approximately 3 seconds to enter menu mode. The following will be displayed: 2. Press the key to enable (ys) or disable (no) the auto power off feature. 3. Press the key to proceed to the display mode screen. 4. Press the key to proceed to the alarm adjustment screen. 5. Press the key to return to normal operation. Display Backlight The backlight can be activated at any time as required: After the 721 has been turned on and has gone through the warm up period, press and hold the key for approximately 3 seconds to activate the backlight. The backlight will remain on for approximately 20 seconds. 13

Additional Features (continued): Mute Function When the 721 encounters a gas concentration above the alarm set point the alarm will begin to sound. Pressing the key will silence the alarm. Zero Function If the 721 fails to auto zero the zero key can be used to zero the display. Turn the 721 on in a clean air environment, wait for the sensor test to end, then press the key. Battery Indicator The battery indicator is located in the upper right corner of the display and monitors the condition of the battery: Battery indicator The battery indicator will show full capacity ( ), half capacity ( ), one quarter capacity ( ), and replace ( ). 14

F. Trouble Shooting Problem SENS ERR in display Tick rate inconsistent Weak LCD display Corrective Action Replace sensor Replace batteries / sensor Replace Batteries G. Maintenance Battery Replacement: Depress the latch on the back housing and slide the cover down. Replace batteries (2 x C alkaline) and reattach the cover. Sensor Replacement: Turn the 721 off. Turn the sensor cage counter clockwise and remove it. Unplug the old sensor and discard. Replace sensor and sensor cap. Cleaning your 721: Use a mild detergent and slightly damp cloth to clean the surfaces of the 721. For factory service please return your 721 to: TPI / Attn: Service 9615 SW Allen Blvd. Suite 104 Beaverton, OR 97005 H. Accessories Replacement Sensor: A739 Soft Pouch: A780 Earphone: A710 15

Test Products International, Inc. 9615 SW Allen Blvd., Ste. 104 Beaverton, OR 97005 Tel: 503-520-9197 Fax: 503-520-1225 www.tpi-thevalueleader.com Test Products International, Ltd. 342 Bronte Road South, Unit #9 Milton Ontario Canada L9T5B7 Tel: 905-693-8558 Fax: 905-693-0888