I TS-12 1 Y K DO WHAT THEY DON T. Model. INSTALLATION lnstrljctlons. FIRE BURGLARY lnstrumentsrn INC.

Similar documents
Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

TECHNICAL DATA OBSOLETE

AL600ULADA. NAC Power Extender. Installation Guide

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

RELEASE DEVICE CONTROLS

WE DO WHAT THEY DON T. 1 TS-12CSl. Model INSTALLATION INSTRUCTIONS. FIRE BURGLARY INSTRUMENTS INC. 50 Engineers Road, Hauppauge, N.Y.

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

AL800ULADA. NAC Power Extender. Installation Guide

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Installation Guide for models:

MODEL B2 INSTALLATION MANUAL

Installation Guide for models:

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

30.45 Electric Release PDRP-2001

FireNET Plus Wiring Instructions

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

Operation and Installation Guide. Fire Alarm Control Panel

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Model 17A00 Expansion Enclosure

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

INSTALLATION GUIDE XR5FC AND XR5SL COMMERCIAL FIRE PANELS

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

Electric Release Panel Wiring Tips

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

F I R E G A R D D C EXTENDED PERFORMANCE RELEASE DEVICE SAFE A N D SECURE

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

PSN-1000 & PSN 1000(E) Installation Manual

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

Commercial and Light Industrial Fire Alarm Control Panel

XR10/XR20 Command Processor Panels Installation Guide

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

AL600ULX Series. Power Supply/Charger. Installation Guide

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

LifeAlarm Fire Alarm Controls

Series. Access Power Controllers. Installation Guide

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

INSTALLATION MANUAL PC15OO

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

Notification Appliance Circuit Module

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

M O D E L S FIREGARD BV EXTENDED PERFORMANCE RELEASE DEVICE

MR-2602 Two Zone Fire Alarm Control Panel

Specification/ Data Sheet

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

4100U City and Relay Cards Installation Instructions

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

The MS-4412B/MS-4424B(E) FIRE ALARM CONTROL PANELS

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

Instruction Manual. CMP-12/24 Fire Alarm Control Panel. 12 Clintonville Road, Northford, CT DOCUMENT /11/96 REV: D1

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Installation, Operating and Maintenance Manual

Datasheet. Vacuum Double-interlock Preaction System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

MANUAL RESET ALARM RELEASE

Public Safety DAS Annunciator Panel

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

INSTRUCTION MANUAL PC255O

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

OWNER S MANUAL. Extended Performance Release Device. Models: Firefly III Plus, Firefly III Plus with Voiceboard

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

LifeAlarm Fire Alarm Control Panels

FireSeeker Fire Alarm Control Panel Model FS-250 Installation, Operation and Maintenance Manual

INSTRUCTION MANUAL PC255O

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

FEC400 Series. Installation Manual

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

INSPECTION AND TESTING FORM

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

Access Power Controllers with Power Supplies

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

The MS-4424 FIRE ALARM CONTROL PANEL

TABLE OF CONTENTS TABLE OF CONTENTS 1

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

Fire Control/Communicator

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

SPECIFICATION FOR A TOTAL FLOOD ECARO-25 TM CLEAN AGENT FIRE SUPPRESSION SYSTEM FOR USE WITH THE SHP PRO CONTROL PANEL SYSTEM

Datasheet. Dry-pipe Vacuum Sprinkler System, Electric Release Self contained unit. Features. FIREFLEX VACTEC description

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

Transcription:

Model I TS-12 1 INSTALLATION lnstrljctlons Y K FIRE BURGLARY lnstrumentsrn INC. 50 Engineers Road, Hauppauge, N.Y. 11788 516-582-6j61 800-645-5430 DO WHAT THEY DON T....................................................................................... --. I-1051 ISSUE H 9185

.I MODEL ITS-12. INSTALLATION MANUAL. - 1. GENERAL INFORMATION * t. '. '".(,, L-p 'j@ ';,%).! 2. FUNCTIONAL,-SWiTCHES, ;.I I A '-,&a.t 6;,$ $k,!' 3. ZONE DETECTION (INPUT CIRCUITS) 4A. SUPERVISED SIGNAL CIRCUIT WIRING (ALARM OUTPUT) 4B. ALARM DRY CONTACTS 5. 6. 7. REMOTE SIGNALLING POLARITY REVERSAL (TELE-LINES) - OPTIONAL WATERFLOW CONNECTION ( \ L POWER SUPPLY 8. 12VDC SMOKE DETECTOR POWER 9. AUXILIARY POWER 10. STAND-BY BATTERY CALCULATIONS 11. REMOTE TROUBLE - OPTIONAL 12. REMOTE ALARM ANNUNCIATOR 13. EXPANSION FROM ONE ZONE To FOUR ZONES 14. CODED OPERATION 15. GROUNDING (GROUND DETECTION) 16. WIRING RESISTANCE CHART 17. TROUBLE SHOOTING I

1. GENERAL INFORMATION The TS-12 is a.single zone fire alarm control panel which is field expandable to 4 zones with the addition of the "optional" 3-ZDM MODULE. The TS-12 is U.L, listed to meet NFPA standards 72A (local) 72C (Remote Station Signalling) and 74 (Household Fire Warning). 2. FUNCTIONAL SWITCHES A. TEST Operation of this switch alarms all zones and activates all local audible and visual devices. In addition the optional reversing relay (K-4) will activate and transmit a signal to the Remote Station. If transmission to the remote station is not desirable during this test CUT J-6 before testing. NOTE WHEN RESETTING THE PANEL FROM TEST CONDITION, HOLD DOWN SYSTEM RESET SWITCH, MOVE TEST SWITCH BACK TO NORMAL =-%-LEASE RESET SWITCH. B. SIGNAL SILENCE (ALL ZONES) This switch when in down position shall silence all alarm signals connected to the system. Each active zone has its own individual SIGNAL SILENCE SWITCH. When in down position, this switch shall cause a zone trouble (YELLOW L.E.D.) as well as a system trouble (YELLOW L.E.D.). NOTE This switch will not effect the Reversing Relay. unless the switch is operated before an alarm occurs. C. RESET SWITCH This switch when depressed resets all zones and smoke detectors from the alarm condition. NOTE Before resetting panel the device that caused the original alarm must be reset. D. TROUBLE SILENCE SWITCH When a system trouble occurs the yellow system trouble L.E.D. will light and the audible trouble signal will sound. Sliding the switch down to the silence position shall silence the audible signal ONLY. Upon restoration of the troubied circuit the audible trouble signal shall re-sound indicating to the installer to return the trouble signal switch back to its normal position, which shall silence the audible signal and extinguish the system trouble YELLOW L.E.D. 3. SUPERVISED DETECTION CIRCUIT Terminal 5(+) and 4 (-1 are for the connection of any N.O. U.L. listed device (heat detectors, manual pull stations, contacts of smoke detectors, etc.). Supervision is achieved with the installation of a 3900 ohm 1/2W resistor 3

4A. SUPERVISED ALARM SIGNAL OUTPUT 48. connected in parallel withi.n the last device on the circuit, (Refer to DWG #12-100-1001 on inside of cabinet door). This resistor is factory provided. The maximum allowable loop resistance is 4000 ohms (with EOL and field wiring). If a break in the zone wiring should occur, the corresponding zone trouble L.E.D (YEL.LOW) will light and a system trouble will occur. (Refer to TROUBLE SILENCE SWITCH and proceed as indicated). Terminal 7 (-1 and 8 (+> are for connection of ONLY U.L. listed 12 V.D.C. polarized signalling devices. This output is supervismth the installation of a 220 ohm 5W resistor which connects in parallel within the last signalling device on the circuit. (Refer to DWG #12-100-1001 located on inside cover of cabinet). This output is fused at 1 amo. (DO NOT EXCEED.850A). If a break or short should occur in the field wiring, t.he yellow signal circuit fault L.E.D. will light and a system trouble will occur. (Refer to TROUBLE SILENCE SWITCH and proceed as indicated). ALARM DRY CONTACTS Term 9 (C), 10 (N.C.) and 11 (N.O.) are Form lc l dry contacts. These contacts will transfer whenever an ALARM has occurred or IF THE TEST SWITCH HAS BEEN OPERATED. "Contact Ratings 26 VDC @ 5A resistive." 5. REMOTE SIGNALLING VIA LEASED LINES (POLARITY REVERSAL) Installing (optional) relay K4 will provide a current limited 12VDC output on term 13 (-> and 12 (+). This output is provided for connection to a polarity sensitive remote receiving panel. (Maximum available current to maintain 12 VDC is.020a). If transmission of a system trouble to the remote station is required, install trouble relay K3 and cut 34. NOTE The transmission of an ALARM signal will override the trouble condition. CAUTION Refer to item 2A t Testlt. Note The following may be waived by the governing Fire Authority. When this panel is connected to a remote station receiving unit, program the zone silence switch for non-silencing conditions by connecting the zone jumpers as indicated in paragraph 6 below. 6. WATERFLOW SWITCH CONNECTION When connection is made to a waterflow alarm switch, a jumper must be connected on the zone used for waterflow. EXAMPLE Zone I/ Connect 1 33 2 JlO 3 313 4 516 NOTE Consult factory when ordering panel for waterflow alarm connector. 7. POWER SUPPLY The 12 VDC output of the power supply is unregulated, filtered and rated at 3 amps. _ It also provides current for charging sealed lead acid (gel type) stand-by batteries up to 8, A.H. of capacity. The transformer secondary is fused at 4 amps. Connection to 110 VAC must comply with the local codes and/or article 760 Fire Protection Signalling Systems of the National Electric Code NFPA # 70-1975.

Upon loss of 110 VAC the control panel will stand-by and a system trouble will occur. automatically transfer to battery l 8. 12 VDC SMOKE DETECTOR POWER (See Note 1) Terminals 2 (-) and 3 (+) is a 12 VDC regulated and fiitered output. This output is fused at LA..Operation of the reset switch removes power from this output and resets all smoke detectors. 9. SMOKE DETECTOR POWER (SEE NOTE 1.) *. Terminals 1 (+) and 2 (-1 is a 12 VDC regulated and filtered output used for powering external devices such as ie (door holders, transmitters, auxllliary relay, etc.) This output is fused at 1A. (DO NOT EXCEED.750A). 10. STAND-BY BATTERIES NOTE OPERATION OF THE RESET SWITCH HAS NO EFFECT ON THIS OUTPUT. * A 12 VDC re-chargeable sealed lead acid battery may be connected to this panel utilizing the RED wire (positive) and the BLACK wire (negative). The control. panel power supply has enough capacity provides charging current up to.250a. to re-charge sealed lead acid batteries This charging up to 8 A.H. current capacity. BATTERY STAND-BY CALCULATIONS l i! A single zone control panel draws.055a A four zone control panel draws.096a to comply with local codes and NFPA battery stand-by requirements. See chart below 24 HOUR STAND-BY NUMBER OF ZONES USING 4 A H. ' BATTERIES 1.085~i. 4.044A USING 6 A.H. BATTERIES USING 8 A.H. BATTERIES.155A.225A.114A.185A 60 HOUR STAND-BY -.-. NUMBER OF USING 4 A.H. USING 6 A. H. IJSING 8 A. H. ZONES BATTERIES BATTERIES BATTERIES 1.005A.03OA.070A 4 N/A N/A.030A Note 1 All the above figures are the maximum allowable current, which may be drawn by external devices connected to the TS-12. EX Smoke detectors, door holders, tele-lines, and other energized devices drawing current from the control panel while in its normai supervisory condition. NOTE DO NOT INCLUDE ANY ALARM SIGNALLING DEVICES IN YOUR CALCULATIONS.

11. 12. 13. REMOTE TROUBLE - OPTIONAL Installing Relay K-3 will provide a set of N.O. Dry Contacts on terminals 15 and k Whenever a s&em trouble occurs, these contacts will close and remain closed until all system trouble conditions are cleared. REMOTE ALARM ANNUNCIATOR The TS-12 has provisions for the connection of a supervised remote alarm annunciator! The Model RZA-4. This annunciator is a 5 wire device and has 4 alarm L.E.D.'s. The field wiring and associated L.E.D.'s are supervised for breaks. Should a break occur, the corresponding yellow ione trouble L.E.D, will light and a system trouble will occur. Prior to connecting the RZA-4, the following jumpers must be cut. When using just Zone 1 cut J 1. When using all 4 zones cut J 1, J 8, J 11, J 14. CONNECT THE RZA AS FOLLOWS RZA TS-12-1 TS-12-4 C Term (3) Term (3) 1 Term (6) Term (6) 2 N/A Term (17) 3 N/A Term (22) 4 N/A Term (27) EXPANSION FROM ONE ZONE TO FOUR ZONES \ / The TS-12-l single zone panel is field expandable to four zones by installing the 3-ZDM module. The 3-ZDM is supplied with an installation diagram and f-7 complete wiring instructions. (Hardware included) (Refer to DWG. ~~12-180-1001). 1 j 14. CODED OPERATION When using coded initiating devices a corresponding jumper must be cut on the zone (s). (Refer to DWG. i/12-100-1001 for jumper locations). 15. GROUNDING AND GROUND FAULT DETECTION Terminal 14 MUST be connected to a separate EARTH GROUND CONNECTION. Cold water pipe ONLY. Failure to ground the panel properly shall result in a loss of lightning protection, ground detection and will also reduce the systems tolerance to electrical transients and outside electrical influence. NOTE A. C. NEUTRAL OR CONDUIT GROUND IS NOT ACCEPTABLE. Should a ground occur on the field wiring a ground fault trouble light and a system trouble will occur. 16. WIRING RESISTANCE CHART SOLID CONDUCTORS,A.W.G. OR B.& S. L.E.D. will 6 GAUGE 12 14 16 1 OHMS PER/1000 FT. 1.6 ohms 2.5 ohms 4.0 ohms 6.4 ohms 10.0 ohms 16.0 ohms

17. TROUBLE SHOOTING POSSIBLE CAUSE 1. System trouble L.E.D. 1. Failure of 110 VAC. on Sonalert Sounding. 2. Failure of Power Supply. No other Yellow L.E.D. 3. Failure of 4A Fuse on. 2. Ground fault L.E.D. on 1. Field Wiring shunted to ground. 3. Signal circuit fault 1. Open on signal circuit L.E.D. on and system wiring. trouble sounding. 2. Defective signal circuit fuse. 4. Any zone trouble 1. Open in detection loop L.E.D. on and system field wiring. trouble sounding. 2. Relay - unplugged or coil open Kl (Zone 1) Kl (zone 2) K2 (zone 3) 3. K3 (zone 4) Zone silence switch normal. off 4. Remote L.E.D. and/or field wiring open. 5. Zone alarm L.E.D. open. 1. 2. 3. 1. 1. 2. 1. 2. 3. 4. 5. POSSIBLE SOLUTION Check 110 VAC Supply. Check power supply fuse. Check 12,VDC output w/ batteries disconnected. Remove all field wiring from control panel. With your ohmeter check each wire with respect to earth ground. There should be no continuity between wiring and earth ground. Remove wiring from terminals 7 and 8. With your ohmeter connected to these wires you should read 220 ohms f 10%. Reverse your ohmeter leads and you should read 200 ohms or less. This reading will depend on how many devices are attached to the wiring. Replace fuse if defective. Remove wiring from zone. Measure wire with your ohmeter you should read 3900 ohms * 10%. Check coil of relay. You should rend 180 ohms f 10%. Return switch to narmal. Check for continuity with your ohmeter. Cause an alarm on this zone. If L.E.D. won't come on, replace L.E.D. 7165-495 102 Installations in the City of New York must comply to RS17-3 B!SA No. 902-86-m 7

TYPICAL lnstalla i ON LAYWT- flre 1 NOTE ALTERNATE &kns MAY BE REQUIRED FOR THE DEVICES INDICATED BEWW.* FIRST FLOOR OPTIONS OPTIONS WHICH PROJ\DE FOR REMOTE SIGNALING MAY BE ADDED WITE SIMPLY. CAL YOUR INSVLLING COMPANY I FORDETAILS. z DEN 0 LIVING ROOM DINING ROOM LEGEND Q-CONTROL @-HORN -SMOKE DETECTOR. -THERMOSTATS BEDROOM 1 BATH 1 BATH 0 P BEDROOM BEDROOM 0 0 0 BEDROOl rll 3 =I L 3 B i s PREPARATION ( EDUCATION ARE r OF PRIME IMPORTANCE IN FIRE - / PREVENTION.. ESTABLISH A HOUSEHOLD EMERGENCY EVACU- i ATION PLAN IN THE EVENT OF c FIRE 1. Evaluate possible escape routes from your home. 2 Select 2 escape routes from each. i room. 3. Rooms on the second floor should have a rope ladder. (Be sure It will reach the ground.) 4. Draw a rough sketch of your escape plan so that everyone is familiar with it. 5. Practice your escape plan to as- sure that everyone knows what they have to do. 6. Establish a meeting place outside where your family Is to report. 7. Advise the local fire authority that you have installed a fire alarm system. Enter their phone number here 8 CAUTION Early warning fire detection Is best achieved by the installation of fire detection equipment In all rooms and areas of the household as follows A smoke detector installed in each separate sleeping area (the vicinity of, but outside of the bedrooms), and heat or smoke detectors In living rooms, dining rooms, bedrooms, kitchens, hallways, attics, furnace rooms, closets, utility and storage rooms, basements and attached garages.