CLEARANCES TO COMBUSTIBLES

Similar documents
Engineering Submittal Data PPRTH Patio Radiant Tube Heaters.

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS

INFRARED RADIANT HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

SECTION GAS-FIRED RADIANT HEATERS

SUBMITTAL DATA S100 & S100U POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS. Page 1 PROJECT: ENGINEER: CONTRACTOR:

Typical Mount Height. Combustion Chamber

SERIES. 10 year limited warranty on Burner Core 5 year limited warranty on All combustion and. 2 year limited warranty on All Burner Controls

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

Parts List for Ener-Radiant XL Tube Heaters

Omega II SUBMITTAL DATA. Pre Engineered Packages. Products by: COMBUSTION RESEARCH CORPORATION PROJECT: LOW-INTENSITY INFRARED HEATING SYSTEMS

INFRARED RADIANT TUBE HEATER

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Copyright 2011 AIA MasterSpec Full Length 06/11 PRODUCT MASTERSPEC LICENSED BY ARCOM TO CALCANA USA LTD.

Min. Mount Height. Min. Mount Height. Length Weight

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Insert Manual. DET3 Series WARNING. For Your Safety

GARAGE / WORKSHOP INFRARED HEATERS

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

COMMERCIAL-GRADE RESIDENTIAL GAS WATER HEATERS

Insert Manual. SV Series WARNING. For Your Safety

A. Product Data: Include rated capacities, furnished specialties and accessories.

Residential Gas Tankless Water Heater

INFRARED RADIANT TUBE HEATER

Tankless Condensing High Efficiency Water Heaters with Built-In Pump

Residential/Commercial Gas Condensing Tankless Models

Cumberland Heating Systems

SAFETY FEATURES: Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations.

Commercial Tankless Rack System

NAVIEN AMERICA INC FITCH AVENUE IRVINE, CALIFORNIA, USA

8+* Bulletin No November 1997

Commercial Tankless Rack System

Insert Manual. RHT Series WARNING. For Your Safety

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

WATER-TUBE POOL HEATERS

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

WATER-TUBE POOL HEATERS

SUBMITTAL SCHEDULE & DATA

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

C1210ES Tankless Water Heater

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

940ES Tankless Water Heater

Commercial Tankless Rack System

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

Setting A New Standard For Extra High Efficient, Infrared Tube Heaters 30% More Efficient Than Typical Models

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Insert Manual. DES Series WARNING. For Your Safety

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

Tankless Condensing High Efficiency Water Heaters

940ES Tankless Water Heater

Commercial Tankless Rack System

INFRARED RADIANT TUBE HEATER

GAS-FIRED HIGH AND LOW INTENSITY INFRARED HEATERS

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

C1050ES Tankless Water Heater

Residential & Commercial

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

Installation / Operating Instructions for Easy Radiant Works Infrared Radiant Tube Heater

13 GEP A L P - 1 A

FINNED WATER-TUBE POOL HEATERS

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

U n i t H e at e r s

DIVISION FINNED WATER-TUBE WATER HEATERS

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

Insert Manual. XTS3 Series WARNING. For Your Safety. For complete installation instructions, see the General Manual that accompanies this insert.

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

CATALOG: HVAC - Gas Space Unit Heating

DIVISION FINNED WATER-TUBE WATER HEATERS

TECHNICAL SUPPORT: SERVICE BULLETIN #4 (v ) AB2017 HOT SURFACE IGNITION MODULE OVERVIEW

RGE 13 A T - 1 A

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

ED-40U ED-40S 40,000 BTU LIQUID PROPANE OR NATURAL GAS

DIVISION FINNED WATER-TUBE BOILERS

Insert Manual. RVA2 Series WARNING. For Your Safety

Tube Heater General Manual

Mascot. Gas-Fired Residential and Commercial Wall-Mounted Boiler. Easy Installation, 96% Efficiency, Fully Condensing

Installation/Operating Instructions for: The Equator. H.I. Series Indoor/Outdoor Infrared Patio Heaters

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

Brooders. Better Brooding for Your Chicks... Since 1924

LS Series Installation Manual

DIVISION FINNED WATER-TUBE BOILERS

iq1001, Gen II Submittal Data

Whole House Action Guidelines

Infrared Heating Catalog

Transcription:

12288 Brawn Road 22, Wainfleet, Ontario, Canada L0S 1V0 Phone: 905-899-3473 Fax: 905-899-2262 www.easyradiantworks.com email: erw@vaxxine.com Engineering Submittal Data EZB series straight and U shape radiant tube brooders. Adding the suffix LTH indicates dual input with the low input being 70% of the high input. Model O/A Length Input (BTU) Weight EZB-60-20 21 ft. 8 / 6.6 m 60,000 90 lbs / 40.82 kg EZB-75-20 21 ft. 8 / 6.6 m 75,000 90 lbs / 40.82 kg EZB-80-20 21 ft. 8 / 6.6 m 80,000 90 lbs / 40.82 kg EZB-85-30 31 ft. 5 / 9.56 m 85,000 105 lbs / 47.63 kg EZB-100-30 31 ft. 5 / 9.56 m 100,000 105 lbs / 47.63 kg EZB-125-30 31 ft. 5 / 9.56 m 125,000 105 lbs / 47.63 kg EZB-100-40 41 ft. 2 / 12.55 m 100,000 130 lbs / 58.97 kg EZB-125-40 41 ft. 2 / 12.55 m 125,000 130 lbs / 58.97 kg EZB-150-40 41 ft. 2 / 12.55 m 150,000 130 lbs / 58.97 kg EZB-125-50 50 ft. 11 / 15.5 m 125,000 150 lbs / 68.04 kg EZB-135-50 50 ft. 11 / 15.5 m 135,000 150 lbs / 68.04 kg EZB-150-50 50 ft. 11 / 15.5 m 150,000 150 lbs / 68.04 kg EZUB-60-10 11 ft. 11 / 3.63 m 60,000 90 lbs / 40.82 kg EZUB-75-10 11 ft. 11 / 3.63 m 75,000 90 lbs / 40.82 kg EZUB-80-10 11 ft. 11 / 3.63 m 80,000 90 lbs / 40.82 kg EZUB-85-15 16 ft. 8 / 5.08 m 85,000 105 lbs / 47.63 kg EZUB-100-15 16 ft. 8 / 5.08 m 100,000 105 lbs / 47.63 kg EZUB-125-15 16 ft. 8 / 5.08 m 125,000 105 lbs / 47.63 kg EZUB-100-20 21 ft. 8 / 6.6 m 100,000 130 lbs / 58.97 kg EZUB-125-20 21 ft. 8 / 6.6 m 125,000 130 lbs / 58.97 kg EZUB-150-20 21 ft. 8 / 6.6 m 150,000 130 lbs / 58.97 kg EZUB-125-30 31 ft. 5 / 9.56 m 125,000 165 lbs / 74.84 kg EZUB-135-30 31 ft. 5 / 9.56 m 135,000 165 lbs / 74.84 kg EZUB-150-30 31 ft. 5 / 9.56 m 150,000 165 lbs / 74.84 kg CLEARANCES TO COMBUSTIBLES BTU RANGE BELOW TOP SIDES BACK (Angle Mount) 60,000-150,000 48 / 121.92 cm 4 / 10.16 cm 25 / 63.5 cm 16 / 40.64 cm Clearances below can be reduced by 40% beginning 15 ft. downstream of burner. Page 1

SPECIFICATIONS APPROVALS * Intertek ETL * Certified for use in Canada and the USA * Tested and certified at the Intertek ETL laboratories to all applicable CAN/CGA, CSA, and ANSI standards. * Commercial, Industrial, and Agricultural approvals. BURNER CONTROL BOX * Totally enclosed controls * Sight glass for visual combustion observation * Controls serviceable while in operation and isolated from combustion air * Operating indicator light standard * Easy access to controls with the removal of one screw with exclusive hinged Clamshell control box design. * Thermally protected and permanently lubricated blower motor * 5 long grounded cap and cord plug in 110v connection COMBUSTION AIR & VENTING * 4 combustion air inlet and exhaust * Certified for direct sidewall, roof, and open venting * Maximum 60 of combined intake and vent line (NOT including length of unit) in any combination (eg. 15 intake, 45 vent). Deduct 5 from 60 allowance for every 90 degree bend in intake/vent line. GAS SPECIFICATIONS Pressures in W.C.P. NG (inches) LP (inches) Manifold 3.5 10 Min. Inlet 7 14 Max. Inlet 14 14 ELECTRICAL SPECIFICATIONS * 120 V.A.C., 60 Hz, 1 Ph., 3 wire * Supplied via 5 ft. 120v 3 wire cap and cord plug in connection * Factory ready for 120v or 24v thermostatic controls * Ignition current 3 amps * Running current 1 amp CONTROLS * Norton ceramic hot surface mini igniter * Air proving safety switch monitors for blocked flu and intake air * Independent flame sensing rod * Independent flame sensing rod Honeywell Smart valve OR White Rogers valve with proprietary electronic controls made in the USA * LTH 2 stage models c/w White Rogers valve and proprietary electronic controls made in the USA COMBUSTION & EMITTER TUBES * All emitter & combustion tubes are 16 ga., 4 OD * Tubes press fitted with swaged ends * Primary combustion tubes constructed of high temperature specialty alloys * Secondary tubes are constructed of highly emissive low carbon black steel. EZB model secondary tubes are coated with high temperature, corrosion resistant black coating. * High temperature, aluminized steel turbulator baffle factory installed (if required) REFLECTOR * Highly polished, high grade seamless aluminum for maximum reflective efficiency * EZ models c/w upgraded mirror polish for superior reflectivity and emission NO IFS, ANDS, OR BUTS WARRANTY * 4 Years on ALL heater components * 20 year burnout guarantee on combustion and emitter tubes MANUFACTURED IN CANADA WITH NORTH AMERICAN MADE COMPONENTS AND MATERIALS COMMON ACCESSORIES PART # DESCRIPTION NOTES AC1072 AC1073 ½ x 36 Neoprene Flexible Gas Connector ¾ x 36 Neoprene Flexible Gas Connector Required for units under 150,000 BTUH (Included) Required for units 150,000 BTUH or greater (Included) AC1220 AC1050 AC1090 AC1170 Fresh Air Intake Package Rigid Attic Air Intake w/adaptor for AC1220 Rigid Attic Air Intake Brooder Exhaust Cap (screened) 4 dia. flex duct, screened intake cap, connectors (Included) For drawing combustion air from attic space For drawing combustion air from attic space For open venting inside of barns (Included) AC1180 Sidewall Exhaust Cap 4 OD - type B Vent Required for direct sidewall venting AC1190 Sidewall Exhaust Cap 4 ID - type C Vent Required for direct sidewall venting AC1120 4 x 4 x 6 Exhaust T For common venting Note: units MUST be jointly controlled. AC1060 24v Analog Thermostat In Celsius. For Fahrenheit, use part #AC1062 AC1010 110v Analog Thermostat For control of single or multiple units AC1400 24v Digital 2 Stage Thermostat For control of single 2 stage units AC2000 24v Light Activated Set Back Digital Stat The Easy Set www.easyradiantworks.com/easyset.html P-1930 9 x 10 Side Reflector Reflector side shield to reduce output on sides of heater Page 2

FIELD SPECIFICATIONS SIDEWALL VENTING ROOF VENTING *Note: Vent lines longer than 10 must be insulated or constructed of insulated type B material. End View Horizontal and Angle Mount Page 3

FIELD SPECIFICATIONS (Cont.) Burner and Controls Side View U Configuration Top Down Straight Configuration Top Down Page 4

WRITTEN SPECIFICATIONS Gas fired radiant tube heaters shall be Comfortzone Brooder (EZB) series heaters manufactured by Easy Radiant Works, Wainfleet, Ontario, Canada. Radiant tube heaters shall be furnished and installed in compliance with all applicable governing codes and in compliance with included manufactures specifications. In cases where manufacturers instructions and governing codes conflict, installer shall defer to whichever is most stringent. Radiant tube heaters shall be Design Certified by Intertek ETL, and comply with all applicable standards including CAN/CGA, CSA, and ANSI. All radiant tube heaters must bear the Intertek ETL certification mark and manufacturers serial number. Radiant tube heaters shall be supplied with a manufacturers warranty covering all components for a period of no less than four (4) years. Combustion and radiant emitter tubes shall be warranted against burnout for a period of no less than twenty (20) years. Radiant tube heaters shall be supplied with a copy of the manufacturers installation and operation manual. Burner controls shall be totally contained within a control housing that is isolated from combustion air. Control housing shall be of such construction that internal components are accessible for diagnostic purposes while heater is in operation. Control housing shall be of the clamshell type, with access granted to controls by the removal of exterior retaining screws. Combustion tubes shall be constructed of 16 ga. (0.065 ), 4 dia. aluminized steel tube coated with black high temperature coating. Emitter tubes shall be constructed of 16 ga. (0.065 ), 4 dia. low carbon steel tube. EZB model emitter tubes shall be coated with high temperature black coating. Combustion and emitter tubes joints shall be of press fit design with swaged ends at 4 ID. Tubes shall be mechanically secured by means of manufacturer provided self-drilling screws. Reflector material shall have a minimum thickness of 0.025 (+/-.001 ), shall be constructed of seamless 3003 aluminum sheet, and be tempered to specifications H24-H25. Reflector finish shall be a minimum of Brite-one-side. Heaters shall be equipped with an electronic hotsurface igniter that is enclosed in a protective metal jacket. Heaters shall be equipped with an independent flame sensor. Heaters shall be equipped with a sight glass for visual confirmation of combustion and igniter operation. EZB models shall be equipped with an operating indicator light on the bottom of the control housing to indicate normal heater operation. Single stage heaters shall utilize the Honeywell Smart Valve or a White Rogers valve with proprietary control module for control sequencing and gas flow regulation. Two stage units shall utilize a White Rogers two stage valve with proprietary control module. Units shall utilize two dedicated mechanical air pressure switches, one for blocked flue and one for combustion intake air pressures. Air switches shall be factory set to correct pressures with no requirement for field adjustment. Units shall be constructed with a five foot (5 ) long grounded 110v capped connector. Units shall be supplied ready to accept both 110v and 24v thermostatic controls. If required, heaters shall be equipped with a preinstalled turbulator baffle constructed of aluminized steel, and pre-installed by the factory in a marked 10 section of emitter tube for installation on the exhaust end of the heater. Heater shall be constructed that total safety shut down will occur in the events of: loss of combustion, blocked flue, blocked air intake, blower failure, loss of 110v power, increase of gas pressure beyond specification, or combustion failure on ignition attempt. Unit shall lock out operation entirely in the event that there are three (3) to five (5) consecutive failures, and only be reset by means of disconnection of 110v power supply. Page 5

CONTACT INFORMATION SUBMITTED BY: JOB JOB TITLE: ENGINEER COMPANY: DATE: CONTRACTOR COMPANY: EQUIPMENT REPRESENTATIVE COMPANY: 12288 Brawn Road 22, Wainfleet, Ontario, Canada L0S 1V0 Phone: 905-899-3473 Fax: 905-899-2262 www.easyradiantworks.com email: erw@vaxxine.com WARNING! Heaters must be installed and serviced by qualified and licensed gas personnel only. Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. This spec-sheet is not the installation manual. Page 6