THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #4

Similar documents
THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #5

Developing a Healthcare Facility Fire Door Inspection Program

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #2

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

Agency for Health Care Administration

Changes to the 2018 Joint Commission Comprehensive Accreditation Manual for Hospitals (CAMH)

THE 2012 EDITION OF THE LIFE SAFETY CODE HOSPITAL EDITION SESSION #6

Agency for Health Care Administration

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

Agency for Health Care Administration

NFPA 101 Life Safety Code Culture change 2012

Agency for Health Care Administration

CMS Announcement 3/27/2017. Adoption of 2012 Life Safety Code Health Care Facilities Code. Kenneth Daily, LNHA

Agency for Health Care Administration

LIFE SAFETY COMPLIANCE: ADAPTING TO THE 2012 LIFE SAFETY CODE

Agency for Health Care Administration

NFPA 101 Code Update from 2012 Edition to the 2015 Edition

NFPA 80 Overview January 21, 2016

Life Safety Code Common Discepancies Course# LSC102. EZpdh.com All Rights Reserved

New DATE OF BLDG. PERMIT OR PLAN APPROVAL: SURVEYOR (SIGNATURE) TITLE OFFICE DATE REVIEW AUTHORITY OFFICIAL (SIGNATURE) TITLE OFFICE DATE

Iowa State Fire Marshal

2012 Life Safety and Health Care Facility Codes - Door Inspections and Other Critical Inspection, Testing and Maintenance

Agency for Health Care Administration

Agency for Health Care Administration

Report on First Revisions with Statement June 2014 NFPA 101

Fire & Life Safety Code Compliance. Common Safety Deficiencies and Tips for Compliance for Long Term Care and Skilled Nursing Facilities

Top (15) Life Safety Code Deficiencies and Tips for Compliance (10/01/2011 thru 02/22/2012)

ASCs & LSC. Alice Epstein, DFASHRM, FNAHQ

Agency for Health Care Administration

EC EP 14 All other electrical K-920 equipment in patient care vicinity NFPA , Chapter 10

Chapter 43, Building Rehabilitation allows for degrees of compliance based on the work category such as the extent of work.

WHAT TO EXPECT DURING A FIRE DOOR INSPECTION

NFPA 101 and NFPA 99, 2012 Editions Code Update. where art meets engineering

FIRE SAFETY SURVEY REPORT AMBULATORY SURGICAL CENTERS (ASC) & END STAGE RENAL DISEASE (ESRD) MEDICARE

Department of Health Life Safety Code Update

Agency for Health Care Administration

Swinging Egress and Fire Doors

Ohio Department of Health NFPA 2012 Life Safety Code Tips Sheet

Are there any policies regarding outlets that contain USB ports?

Agency for Health Care Administration

The New Life Safety Code & Texas Responds with New Small House Nursing Design Standards

FHCA 2014 Annual Conference & Trade Show

Wausau Fire Department Inspection Violation Code Listing (Modified) All Applicable Records

FIRE SAFETY SURVEY REPORT 2000 CODE - HEALTH CARE Medicare Medicaid

Prepublication New Text Jan 2018 Changes to Environment of Care and Life Safety Chapters

PRINTED: 06/09/2017 FORM APPROVED CENTERS FOR MEDICARE & MEDICAID SERVICES OMB NO (X2) MULTIPLE CONSTRUCTION A. BUILDING 03 - A BUILDING

Building Codes & Standards for Healthcare. Healthcare Construction Certificate - Level 1

K SURVEY FOR DATE OF PLAN APPROVAL SURVEY UNDER

Agency for Health Care Administration

The following are the Proposed Amendments to 2015 edition of the Life Safety Code (NFPA 101):

Fire and Smoke Door Inspections Qualified Training 02/03/17

Presented by: Brad Keyes, CHSP Senior Consultant Keyes Life Safety Compliance, LLC

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

First Revision No NFPA [ Section No ]

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

Report on First Revisions with Statement June 2014 NFPA 101

Agency for Health Care Administration. Eddie Alday Life Safety Code Lead 30 th AHCA Seminar 23 September 2014

Fire Rated Door Assemblies: Compliant Designs

CMS CATEGORICAL WAIVER CHECKLIST Page 1 of 7 Waiver Topic, description & location:

FIRE SAFETY SURVEY REPORT 2000 CODE - HEALTH CARE Medicare Medicaid

Level I Chapter 1 Worksheet

CHAPTER 7 ALTERATIONS LEVEL

First Revision No NFPA [ Global Input ] Submitter Information Verification. Committee Statement

Presented by: Bill Lauzon, PE Lauzon Life Safety Consulting, LLC Web: Lauzon-LSC.com

Agency for Health Care Administration

Life Safety Crosswalk

LIFE SAFETY CODE MAINTENANCE MANUAL

Center for Clinical Standards and Quality /Survey & Certification Group

SAF-BCF SECOND REVISIONS WITH STATEMENTS

Accreditation Program: Hospital

JOINT COMMISSION PREPAREDNESS / STATEMENT OF CONDITIONS DRAWINGS WSSHE SOUTHWEST CHAPTER NOVEMBER 19, 2015

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

Chapter Nursing Homes

Schools and the Fire Code A Partnership for Safety

About the Instructor & Presenter:

School Fire Safety Checklist

NFPA 45 NFPA 211 NFPA 1600

Taming the Health Care Building Codes NFPA vs. The International and Chicago Building Codes JENSEN & HALSTEAD LTD.

Chapter 2: Definitions

C. None (No sprinkler system) K3 E. NUMBER OF BEDS CERTIFIED FOR MEDICAID

Candy Easterling K-063. Adequate and Reliable Water Supply for the Sprinkler System. CITY WATER or WATER TANK for Sprinkler System

Osceola County Department of Fire Rescue and Emergency Medical Services

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

Clackamas Fire District #1 Self Inspection Program. Oregon Fire Code (OFC)

Changes to Environment of Care and Life Safety Chapters Related to Life Safety Code Updates

4/9/2014. Life Safety Code. Nursing Facility Life Safety Code Today and Tomorrow. Kenneth Daily, LNHA.

M E M O R A N D U M. All Licensed Assisted Living Facilities. Felicia Cooper, Deputy State Fire Marshal Administrator Don Zeringue, Chief Architect

DEALING WITH FIRE SAFETY

Resolution: FR-2-NFPA Statement: The new language requires the action completed by NFPA 557 be prepared by a person that is approved.

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

Building & Fire Code Academy. Building Better With Our Greatest Resource Education. Welcome!

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

Report on Public Input June 2014 NFPA 101

1. Are there any annual sprinkler head inspection forms available? No, there are none available at this time.

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

Residential-based Care Facility R-4 Guideline

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

Defend In Place 2012 IFC Overview of Institutional Occupancies

Transcription:

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #4 WELCOME Moderator: Richard Schieferdecker support.webinato.com Audio 1

QUESTIONS How To Ask a Question: POLLING There will be occasional interactive poll questions. 2

THE 2012 EDITION OF THE LIFE SAFETY CODE NURSING HOME EDITION SESSION #4 3

Chapter 43 Building Rehabilitation Chapter 7 Fire and Smoke Door Inspections Building Services Utilities HVAC Operating Features Fire Safety Plans Draperies / Curtains Furniture Elevators Trash & Laundry Chutes Mattresses Decorations Soiled Linen / Trash Receptacles CHAPTER 43 BUIDING REHABILITATION 19.1.1.1.3 General. The provisions of Chapter 4, General, shall apply. 4.6.7 Building Rehabilitation. 4.6.7.2 Rehabilitation work on existing buildings shall comply with Chapter 43. 4

CHAPTER 43 BUIDING REHABILITATION 43 Building Rehabilitation (New Chapter) Facility modifications must comply with new Chapter 43 of 2012 LSC Requirements dependent upon category of work as defined: Repair Renovation Modification Reconstruction Change of use / occupancy Addition HINT: ANY TIME YOU PICK UP A HAMMER CONSIDER CHAPTER 43 AND CHAPTER 18 REHABILITATION CHAPTER 43 AN EXAMPLE 43.2.2.1.2 Renovation. The replacement in kind, strengthening, or upgrading of building elements, materials, equipment, or fixtures, that does not result in a reconfiguration of the building spaces within. New work shall comply with the requirements of existing buildings. New interior finish materials shall meet the requirements for new construction. Reconfiguration or extension of any system, or the installation of any additional equipment, shall comply with Section 43.5 (Modifications). 5

CHAPTER 43 BUIDING REHABILITATION EXISTING HAZARDOUS AREAS: 19.3.2.1.5 (New & Revised Text) Safe guarded by a fire barrier having a 1 hour fire resistance rating OR An automatic sprinkler system 19.3.2.1.2 (New & Revised Text) Where the sprinkler option of 19.3.2.1 is used, the area shall be separated by smoke resisting partitions smoke partitions in accordance with 8.4 CHAPTER 43 BUIDING REHABILITATION NEW HAZARDOUS AREAS: 18.3.2.1. (New & Revised Text) Rooms or spaces, used for storage of combustible supplies and equipment in quantities deemed hazardous by the Authority Having Jurisdiction. 50 100 Sq Ft = Sprinkler & Smoke Partition >100 Sq Ft = Sprinkler & 1 hour FRR Enclosure HINT: SO IF YOU HAVE A RESIDENT ROOM AND CHANGE ITS USE TO STORAGE, NEW CONSTRUCTION APPLIES, WHAT DOES IT NEED TO BE? 6

CHAPTER 43 BUIDING REHABILITATION 43 Building Rehabilitation (New Chapter) Facility modifications must comply with new Chapter 43 of 2012 LSC Requirements dependent upon category of work as defined: Repair Renovation Modification Reconstruction Change of use / occupancy Addition CHAPTER 43 BUIDING REHABILITATION 43 Building Rehabilitation (New Chapter) 43.7.1.2(2) If converting a room to a storage use that exceeds 50ft2, the hazardous area requirements for new construction (Ch. 18) shall not apply if: In an Existing Health Care Occupancy Health Care Occupancy is fully sprinklered Room is less than 250 ft2 7

ANNUAL INSPECTION OF FIRE AND SMOKE DOOR ASSEMBLIES ANNUAL INSPECTION OF DOOR OPENINGS complying with 7.2.1.15.1 (New Text) Where required by the Occupancy Chapter NOT required in Healthcare Doors with panic/fire exit hardware Doors in exit enclosures Electrically controlled egress doors Doors with special locking ANNUAL INSPECTION OF FIRE AND SMOKE DOOR ASSEMBLIES ANNUAL INSPECTION OF DOOR OPENINGS Complying with 7.2.1.15.2 (New Text) Applies to ALL Occupancy Chapters Fire rated doors shall be inspected per NFPA 80 Smoke doors shall be inspected per NFPA 105 Annual requirement, but allows a performance based program 8

ANNUAL INSPECTION OF FIRE AND SMOKE DOOR ASSEMBLIES NFPA 80 FIRE DOORS 5.2.4 Swinging Doors with Builders Hardware or Fire Door Hardware. 5.2.4.1 Fire door assemblies shall be visually inspected from both sides to assess the overall condition of door assembly. 5.2.4.2 As a minimum, the following items shall be verified: ANNUAL INSPECTION OF FIRE AND SMOKE DOOR ASSEMBLIES 5.2.4.2 As a minimum, the following items shall be verified: 1) No open holes or breaks exist in surfaces of either the door or frame. 2) Glazing, vision light frames, and glazing beads are intact and securely fastened in place, if so equipped. 3) The door, frame, hinges, hardware, and noncombustible threshold are secured, aligned, and in working order with no visible signs of damage. 4) No parts are missing or broken. 5) Door clearances do not exceed clearances listed in 4.8.4 and 6.3.1.7. 9

ANNUAL INSPECTION OF FIRE AND SMOKE DOOR ASSEMBLIES 6) The self closing device is operational; that is, the active door completely closes when operated from the full open position. 7) If a coordinator is installed, the inactive leaf closes before the active leaf. 8) Latching hardware operates and secures the door when it is in the closed position. 9) Auxiliary hardware items that interfere or prohibit operation are not installed on the door or frame. 10) No field modifications to the door assembly have been performed that void the label. 11) Gasketing and edge seals, where required, are inspected to verify their presence and integrity. ANNUAL INSPECTION OF FIRE AND SMOKE DOOR ASSEMBLIES NFPA 105 SMOKE DOORS 5.2.1 Inspections Doors shall be operated to confirm closure. Hardware and gaskets shall be inspected annually + NFPA 101 requirements: 10

ANNUAL INSPECTION OF FIRE AND SMOKE DOOR ASSEMBLIES SMOKE BARRIERS DOORS Complying with 19.3.7.8 Doors such as 1 ¾ thick solidbonded wood core doors Doors constructed that resist fire for 20 min (not required to be labeled) Doors must self or automatic close ANNUAL INSPECTION OF FIRE AND SMOKE DOOR ASSEMBLIES SMOKE BARRIERS DOORS Complying with 19.3.7.8 Latching hardware NOT required Not required to swing in direction of exit travel Protective plates, unlimited in height shall be permitted Gap between meeting edges / between door and frame <= 1/8 Door undercuts <= 3/4 11

ANNUAL INSPECTION OF FIRE AND SMOKE DOOR ASSEMBLIES ANNUAL INSPECTION OF DOOR OPENINGS Must be repaired or replaced without delay Written records of inspection/testing shall be signed and kept for AHJs Electronic database is acceptable for documenting The functional testing of door assemblies is NOT required to be performed by a licensed or certified individual, rather they must demonstrate knowledge and understanding. ANNUAL INSPECTION OF DOOR OPENINGS Complying with 7.2.1.15.2 (New Text) HINT: DON T FORGET ABOUT LINEN / TRASH INLET & DISCHARGE CHUTE DOORS OR SHAFT ACCESS DOORS IN YOUR ANNUAL INSPECTION DOOR REQUIREMENTS! 12

POWER STRIPS (Categorical Waiver Sept. 2014 S&C Letter) Resident rooms in long term care or other residential facilities that do not use line operated patient care related electrical equipment are not subject to the more restrictive NFPA 99 requirements regarding use of power strips in patient care areas / rooms. POWER STRIPS Power Strip Use in Patient Care Areas: The facility is electing to apply the categorical wavier permitting the application of the power strip provisions in the 2012 edition of NFPA 99. This also exempts resident rooms in long term care facilities from the NFPA 99 power strip provisions when the facility does not utilize line operated electrical appliances in resident rooms for diagnostic, therapeutic, or monitoring purposes. 13

POWER STRIPS Underwriters Laboratories (UL) Listing Standard UL 1363 UL 1363A UL 60601 1 UL 1449 UL 1778 Phrase / Term Relocatable Power Tap (RPT) Special Purpose Relocatable Power Taps (SPRPT) Medical Electrical Equipment Surge Protective Device (SPD) Transient Voltage Surge Suppressor (TVSS) Uninterruptible Power Supply (UPS) DIRECT VENT FIREPLACES Section 19.5.2.3(2) (New Text) Allows direct vent fireplaces to be installed in smoke compartments containing patient sleeping if the following items are met: Installed per 9.2.2 (related installation standards) Fireplace not installed inside patient sleeping room Smoke compartment sprinklered with quick response or residential sprinklers Fireplace has a sealed glass front with wire mesh panel/screen 14

DIRECT VENT FIREPLACES Section 19.5.2.3(2) (New Text) Allows direct vent fireplaces to be installed in smoke compartments containing patient sleeping if the following items are met: Fireplace controls are locked or in a restricted location Electrically supervised carbon monoxide detection per Section 9.8 is provided in room where fireplace is located Section 9.8 references NFPA 720, Standard for Installation of Carbon Monoxide Detection & Warning Equipment HINT: 2000 LSC ONLY ALLOWED IN SMOKE COMPARTMENTS WITHOUT PATIENT SLEEPING! SOLID FUEL BURNING FIREPLACES Section 19.5.2.3(3) (New Text) Allows solid fuel burning fireplaces to be installed in areas other than patient sleeping areas if the following items are met: Area with fireplace is separated from patient sleeping areas by 1 hour construction Fireplace meets 9.2.2 (NFPA 91, 211, 31, 54, 70) Fireplace has enclosure guaranteed against breakage up to 650F and is made of heat tempered glass or other approved material 15

SOLID FUEL BURNING FIREPLACES Section 19.5.2.3(3) (New Text) Allows solid fuel burning fireplaces to be installed in areas other than patient sleeping areas if the following items are met: Electrically supervised carbon monoxide detection per Section 9.8 is provided in room where fireplace is located The fireplace enclosure required per 19.5.2.3(3)(c) shall be required to be locked if the AHJ feels that special hazards are present Section 9.8 references NFPA 720, Standard for Installation of Carbon Monoxide Detection & Warning Equipment HINT: 2000 DID NOT ALLOW SOLID FUEL- BURNING FIREPLACES! TRASH / LINEN CHUTES Section 19.5.4.5 (New Text) Existing linen chutes shall be permitted to discharge into the same room as trash chutes if the room is sprinklered with: Standard Response Sprinkler Heads or Domestic Sprinkler Heads (if less than 6 heads in room, 0.15 gpm/ft2, & shut off valve provided) per 9.7.1.2 HINT: 2000 LSC DID NOT ALLOW TRASH & LINEN CHUTES TO DISCHARGE IN THE SAME ROOM! 16

EVACUATION & RELOCATION PLAN & FIRE DRILLS Section 19.7.1 (Nothing New Here) Need to have a plan and available to all staff Requires periodic instruction (aka annually by most AHJs) Fire Drill must include transmission of fire alarm Bedridden patients not required to be moved Quarterly each shift 9:00 pm 6:00 am a coded announcement is permitted instead of audible alarms HINT: MANY AHJS INCLUDING CMS ARE INTERPRETING THIS TO MEAN THAT THE VISUAL ALARMS STILL NEED TO BE ACTIVATED DURING THESE TIMES! PROCEDURE IN CASE OF FIRE FIRE SAFETY PLAN 19.7.2.2 (New Text) Use of alarms Transmission of alarms to Fire Department Emergency phone call to Fire Department Response to alarms Isolation of fire Evacuation of the immediate area Evacuation of smoke compartment Preparation of floors and building for evacuations Extinguishment of fire 17

NORMALLY UNOCCUPIED BUILDING SERVICE AREAS (New Section to Chapter 7 / Definition 3.3.21.6) Areas used for routing ducts, pipes, conduits, and similar services, but not visited routinely for storage, maintenance or inspection. Attics Crawl Spaces Chases Interstitial Areas Maintenance NORMALLY UNOCCUPIED BUILDING SERVICE AREAS (New Text 7.13.2.1 7.13.5.2) If over certain square footage, requires specific exiting requirements and means of egress requirements These requirements are, however, more lenient than typical requirements in Chapter 7 18

BUILDING SERVICE AREAS (Section 19.5) This small section of the LSC generally specifies other codes and standards that you must comply with (referred to as required references ). BUILDING SERVICE AREAS (Section 19.5) Utilities (gas and electric) [9.1, & 19.5.1] NFPA 54, National Fuel Gas Code, or NFPA 58, Liquefied Petroleum Gas Code NFPA 70, National Electrical Code NFPA 110, Standard for Emergency and Standby Power Systems HVAC systems [9.2, & 19.5.2] NFPA 90A, Standard for the Installation of Air Conditioning and Ventilating Systems 19

BUILDING SERVICE AREAS (Section 19.5) Elevators, escalators and conveyors [9.4 & 19.5.3] ASME/ANSI A17.3, Safety Code for Existing Elevators and Escalators Waste and linen chute systems [9.5, & 19.5.4] NFPA 82, Standard on Incinerators and Waste and Linen Handling Systems and Equipment DRAPERIES / CURTAINS Section 19.7.5.1 (New Text) Draperies/curtains at windows in patient sleeping rooms in fully sprinklered smoke compartments do not need to comply with 10.3.1 (NFPA 701) Draperies/curtains in other rooms or areas do not need to comply with 10.3.1 (NFPA 701) when the following is met: Size of individual drapery/curtain does not exceed 48 ft2 Total area of drapery/curtain per room or area does not exceed 20% of the aggregate area of the wall on which they are located Smoke compartment is fully sprinklered 20

COMBUSTIBLE DECORATIONS Section 19.7.5.6 (New Text) Combustible decorations shall be prohibited unless one of the following is met: They are flame retardant or are treated with an approved fireretardant coating that is listed & labeled for application to the material to which it is applied Decorations meet NFPA 701, Standard Methods of Fire Tests for Flame Propagation of Textiles & Films Decorations exhibit a heat release rate not exceeding 100 kw when tested per NFPA 289 COMBUSTIBLE DECORATIONS Section 19.7.5.6 (New Text) Combustible decorations shall be prohibited unless one of the following is met: Decorations such as pictures, paintings, other art are attached directly to walls, ceilings, and non fire rated doors in accordance with the following Decorations on non fire rated doors do not interfere with door latching (if required) and do not exceed the area limitations below Decorations do not exceed 20% of wall, ceiling, & door areas inside any room or space of a smoke compartment that is not fully sprinklered Decorations do not exceed 30% of wall, ceiling, & door areas inside any room or space of a smoke compartment that is fully sprinklered Decorations do not exceed 50% of wall, ceiling, & door areas inside patient sleeping rooms having a capacity not exceeding 4 persons in a smoke compartment that is fully sprinklered 21

HINT: STILL NOT PERMITTED! COMBUSTIBLE DECORATIONS Annex Note to Section 19.7.5.6(4) (New Text) The % of decorations shall be measured against the area of any wall or ceiling, not the aggregate total of walls, ceilings, & doors The door is considered part of the wall Decorations must be located so they do not interfere with the operation of smoke detectors, sprinklers, or other Life Safety equipment 22

SOILED LINEN / TRASH RECEPTACLES Section 19.7.5.7.2 (New Text) Containers used solely for recycling clean waste or for patient records awaiting destruction shall be permitted to be excluded from the 32 gallon rule if: Container does not exceed 96 gal Containers exceeding 96 gal are placed in haz areas Container size shall not be limited in haz areas Containers are labeled/listed as meeting FM Approval Standard 6921, Containers for Combustible Waste; however, the testing/labeling/listing is not limited to FM Approvals (any lab can perform the tests) SOILED LINEN / TRASH RECEPTACLES Annex Note to Section 19.7.5.7.2 (New Text) Explains that the provision applies to recycling of bottles, cans, paper, and similar clean items that do not contain grease, oil, flammable liquids, or significant plastic materials FM Approval Standard 6921 ensures that the fire will not spread outside of the container 23

SOILED LINEN / TRASH RECEPTACLES Section 19.7.5.7.3 (New Text) States that the provisions of 10.3.9 applicable to containers for rubbish, waste, or linen shall not apply 10.3.9 Requires containers greater than 20 gal capacity shall: Be provided with lids Lids shall be made of noncombustible materials or meet ASTM E 1354 or NFPA 271 Metal containers must be listed per ANSI/UL 1315 and have noncombustible lids QUESTIONS 24

Next Session Survey and Compliance Strategies THANK YOU Dave Hood President Nick Gabriele Vice President 25