The specification for the equipment supplied complies with the standards of INNOPLANA UMWELTTECHNIK AG and its sub-contractors.

Similar documents
AIRWASH Abrasive Recycling System

METAL CHIP AND COOLANT MANAGEMENT PLANTS

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

BOILER HOUSE PRODUCTS GMS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Halton Rex 600 Basic R6B - Active chilled beam

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

hydrogone horizontal disc dryer A robust and proven design for high capacity sludge drying

Roof top SPACE RPC 450Z R407C M011

Refrigeration & Air Conditioning Experiment No. 5. Experiment No. 5

High temperature air-to-water heat pumps

SECOND HAND ASPHALT PALANT FOR SALE

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

Steam Generator (Boiler) & Steam Turbine. Steam Generator (Boiler) ME 268. Model Lab

HIGH EFFICIENCY POOL DEHUMIDIFIER AND CONDITIONER WITH HIGH HEAT RECOVERY RATES. Air treatment unit. Swimming pool waste air 28 C-65%

Granulators. Piovan Granulators. RSP 15 Series. PIOVAN SpA. Marketing Dept. Lucio Girardello. Mktg Dept (l&g) RSP 15-eng re.01 modification reserved


CNG. PSB Industries. NG Series - Natural Gas Dryers N G-S R NG-SR D N G - E V N G - SV N G R

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Quality & Service Since For the Reduction of Metal Turnings to Shoveling Chips for Briquetting or Pneumatic Conveying

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

GRP Ducting and Glass Tube Heat Exchanger Installation

HOW TO SELECT AN INDIRECT THERMAL TECHNOLOGY FOR INDUSTRIAL MATERIALS PROCESSING

VERSO Air Handling Units

PAPER MILL MANUFACTURER OF SEVERAL TYPES OF BOARDS AND PACKAGING GRADES

ZD Tunnel Inline Cleaning Systems suginocorp.com Zippel GmbH

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Commercial Hot Water Solutions Ltd.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

TREATMENT AND CONDITIONING OF DISMANTLED MATERIAL AND OPERATION WASTE IN EWN OVERVIEW. Rohde, Mathias

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

AIR/LIQUID HEAT EXCHANGERS PROCESS DRYING HEAT RECOVERY SPACE HEATING COOLING & CONDENSING BLAST COOLING

ASPHALT PLANT. atlastechnologiesindia.com

Roof top SPACE RPC 315Z R407C MA00

SAM. Small Air Handling. VES SMALL AIR HANDLERS part of a complete range of innovative, flexible products from the HVAC experts

Introduction to AD-Engineering - Plant components I. R. Waltenberger, R. Kirchmayr

Air Handling Units. Real HVACR people who understand your needs.

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

TopMaster Air Handling unit. Installation instructions

Information on Feeder Systems ProMinent Australia

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

Halton Rex for Vario R6O - Variable air volume chilled beam

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

SR10. Rotative blowing for large mass productionof packagings from 0,1 L to 0,75 L

PUMPKIN SEED HARVESTING TECHNOLOGY 2019

B. Use UT Austin specifications and equipment schedule format for HVAC equipment where available.

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

PELLET MILL. construction s prescriptions and safety. Besides, Nova Pellet S.r.l. has obtained in 2007 the Italian

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

VEXTRA. acoustic comfort Saves up to. 40% floor space. Use. Range. Description. Drycoolers. Slim design and. Capacity up to kw.

Technical Specification

VERSO Air Handling Units

Liquid Ring Vacuum Pumps, Compressors and Systems

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

EKK Anlagentechnik. Plastics and Environmental Technology. Update 01/2018. certified acc. to ISO 9001 ISO 14001

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Shyam Enterprises 9 PACKAGE UNIT

TECHNICAL INFORMATION L / A 1

The paper machine is constituted by equipment manufactured by the following companies:

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

AIR HANDLING THERMAL CONDITIONS

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

ANNEXURE 1 KEY PLAN. Project site. Application Form 1 for Amendment in Environmental Clearance for M/s. Windson Chemical Pvt. Ltd.

ECOCIAT. Domestic hot water heat recovery unit. Use. Range

Atlas Copco. After-coolers, water separators and drains HD 4-96 & TD 8-650, WSD & WD 80/EWD

Industrial. Solutions brands you trust. Product Overview

Air Conditioning Inspections for Buildings Condensers

Biosolids Management Utilizing Solar and Thermal Processes

HT V2 HT Split

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Pre-cleaning for the CRC with Sponge Media Presented By: Ted Valoria Vice President, North America Sponge-Jet, Inc. Project TV

Chip reducer Z. Version

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

POWDER GUIDE. Trouble shooting tips to maximise the benefits of Apcoshield Powder Coatings

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

THE INITIATES PLC (TIP)

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

Vertical self-contained air conditioner

Operating Performance

With the world-renowned SIGMA PROFILE

VACUUM CLEANERS TOUGH, RUGGED AND BUILT TO LAST!

EDPAC International Close Control Air Conditioning Products E

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

BASIL 6000 TUNNEL CAGE WASHER

TMCI Padovan Evaporators

Transcription:

4. LIST OF EQUIPMENT SUPPLIED The specification for the equipment supplied complies with the standards of INNOPLANA UMWELTTECHNIK AG and its sub-contractors. The item numbers sown correspond to the operating diagram enclosed with this tender. 4.1. SLUDGE RECEIVING UNIT (OPTION - SECTION 1000) Client s responsibility. 4.2. DRYING UNIT (SECTION 2000) 4.2.1. Supply of dehydrated sludge The equipment supplied comprises Two twin type feed pumps Item... PO 2001-4 Type... eccentric rotor Supplier... WANGEN Body material... Perbunan Rotor material... V2A (stainless steel) Flow... 0,8 4,3 m 3 /h Motor output... 15 kw Maximum pressure... 8-12 bars Equipped with a feed hopper each with a capacity of 4,5 m 3 (item RF 2002, 2003) and a safety system to prevent running empty and excess pressure. With piping and control to permit filling of client^s cludge silos (see process flow diagram) The pipework connecting to the thin layer dryer and the sludge silos. The requisite instrumentation (see. PFD) 4.2.2. First treatment stage A thin layer dryer Item... EF 2006 Type... horizontal, G 3 Length... 9.8 m Sealed... by stuffing box Transmission... belt Motor output... 75 kw Material:. Fins... Stainless steel. Stator... 1.8928, Dillimax 690T or similar. Rotor... Stainless steel Weight empty... Weight when operating... 10800 kg 14800 kg The equipment will be constructed in accordance with the German TüV and AD- Merkblatt norms. Adaptation to any other norm will incur additional costs

A chopper Item... CH 2007 Type... CHP 15A Changing... Automatic Rotation speed... 0-150 rpm Material in contact with the sludge... Stainless steel Transmission... Belt Motor output... 15 kw Including automatic cleaning of the cutters. Compressed air (6 bars) is required for the automatic cleaning system. The Client is responsible for supplying the air compressor and the supply circuit. For ease of rinsing the sieves with water a single rail lifting device is provided by Innoplana. The area between chooper, belt dryer and rinsing station (to be supplied by the client) is being closed off the rest of the building so that the polluted air can be separately removed to the vent air. Thus another c. 3000 m3/h of vent air are to be removed A steel construction to support the thin film dryer which has to be superimposed to the belt dryer (as well as the heat recovery system) with stairs and safety rails. Clearance between bottom an lower limit of steel construction c. 4.8 m. Clearance for hook of travelling crane from bottom : c 8,5m A distribution belt to the belt conveyor Item... TD 2008 Type... CHP Changing... Automatic Conveyor belt material... PVC External material... painted carbon steel (RAL 5005) and stainless steel 304 Transmission... Belt A rinsing water tank Item... RF 2030 Material:... stainless steel External material... painted carbon steel (RAL 5005) and stainless steel 304 Including the pipework between the tank and the connection to the drying unit. The Client is responsible for the rinsing water (treated effluent) supply pipe and the other systems (valves, pumps, etc.). The requisite instrumentation (see PFD)

4.2.3. Second treatment stage A belt conveyor Item... EF 2009 Number of belts... 5 Motor output (1 per belt)... 5 x 0,5 kw a crusher Item... QC 2010 Motor output... 3 kw 4.2.4. Temperature regulation 4.2.4.1 Belt dryer thermal loop A bracket-mounted recirculating fan Item... CV 2011 Material... Carbon steel Motor output... 30 kw Maximum air temperature... 85 C An exchanger for partially condensing the steam from the second stage, situated on the outlet from the belt dryer Item... EW 2021 Type... steel pipes Hot fluid... Second stage steam Material... Stainless steel An exchanger for condensing the steam from the first stage and reheating the steam from the second stage, situated on the outlet from the belt dryer Item... EW 2022 Cold fluid... Second stage steam Hot fluid... First stage steam Body material... Stainless steel Tube material... Glass An additional exchanger for reheating the second stage steam, situated on the outlet from the belt dryer Item... EW 2023 Cold fluid... Second stage steam Hot fluid... Coolant Body material... Painted carbon steel (aluminiumbronze) Tube material... Galvanised steel

A vent to be connected to the air treatment system; system and connection to be the Client s responsibility. 4.2.4.2 Cooling loop for the last dryer belt A bracket-mounted cooling air fan Item... CV 2013 Material... Carbone steel Motor output... 3kW Maximum air temperature... 35 C An exchanger for cooling the dryer s air on the last belt Item... EW 2026 Type... fine tube Hot fluid... Last dryer belt air Body material... Carbon steel Tube material... Copper / Aluminium The Client is responsible for the pipework supplying the treated effluent as far as the connection flanges on the exchanger. 4.2.4.3 Condensate cooling loop A recirculation pump Item... PO 2014 Motor output... 11 kw Operating temperature... 45 to 60 C An exchanger for condensing the steam and cooling the condensate Item... EW 2024 Cold fluid... Industrial water Hot fluid... First stage condensate Body material... Stainless steel 304 Tube material... Galvanised steel An exchanger for maintaining the coolant temperature Item... EW 2025 Hot fluid... Industrial water Body material... Stainless steel 304 With a bypass exchanger..ew2028 permitting to clean the main exchanger without stopping the dryer by closing/opening manual valves

An expansion vessel Item... RF 2020 Volume... 80 litres Material... Plastic-coated carbon steel The Client is responsible for the pipework supplying the treated effluent as far as the connection flanges on the exchanger. Heat Recovery The energy will be recovered from the cooling loop instead of temperature maintenance via exchanger EW 2025. An exchanger EW 2027 will be supplied addtionally to EW 2025. An exchanger for maintaining the coolant temperature Item... EW 2027 Cold fluid... fluid for reheating Hot fluid... Industrial water 4.2.5. Condensate recovery 4.2.6. Handling A condensate recovery tank Item... RF 2016 Volume... 0,7 m 3 Material... Stainless steel A bracket-mounted air extraction fan on the condensate tank for recirculating this air to the belt dryer Item... CV 2017 Material... Epoxy painted aluminium Motor output... 1,5 kw A condensate pump to enable the tank to be drained Item... PO 2018 Motor output... 0,4 kw Operating temperature... 60 C The pipework supplying the condensate to the tank and then from the tank to the drain pump. The Client is responsible for the pipework for the condensate from the drain pump, from the pump s flange. The provision of a travelling crane by the client.