USER S INFORMATION MANUAL

Similar documents
TB8220U Commercial Programmable Thermostat OWNER S GUIDE

Evolution Control. Zone Control Homeowner s Guide

Infinity Control. Homeowner s Guide. The New Feeling of Comfort

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

User Guide. Color Touchscreen Programmable Residential Thermostat. ComfortSense Model: 13H /2015 Supersedes 7/2015

Smart thermostat with Humidification/De-humidification control

TOUCHSCREEN. COMFORTSENSE Day Programmable Thermostat. 4 Heat / 2 Cool Universal Multi Stage MODEL NUMBER IDENTIFICATION L U FEATURES

Operating Manual. Series Touchscreen Programmable Demand Control Thermostat. UtilityPRO TM

YEAR-ROUND COMFORT EVOLUTION CONTROL ZONE CONTROL HOMEOWNER S GUIDE. The Ultimate Home Comfort System.

ComfortSense 7500 Thermostat. User Guide

Homeowner s Guide / 1

ComfortSense 7500 Commercial Thermostat. User Guide

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Smart Energy Programmable Thermostat + Energy Monitor. EE542-1Z I User Manual

INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Color Touchscreen Communicating with Humidity Control Thermostat TPCC32U01.

Instruction Guide: Thermostat Operation

IMPORTANT Read and save these instructions. OWNER S GUIDE. ComfortSense 5000 Series Models L5711U and L5732U Programmable Touch Screen Thermostats

CONTROLS /08 Supersedes 05/08

User s Manual

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

2018 thesimple, Inc.

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

ATC32U03 igate Communicating, Programmable Thermostat

OWNER S MANUAL Venstar Inc. 08/07

User Manual. Universal Programmable Smart Wi-Fi Thermostat. For Systems Up to 3 Heat / 2 Cool with Wireless Humidity Control*

Owner s Manual ENERGY EFFICIENT, AT A TOUCH OF A BUTTON TSTPRH01, CÔRR 7 TSTWRH01 CÔRR 7C RESIDENTIAL THERMOSTATS. Côrr 7 Series

HEAT COOL. Meets Commercial California Title 24

USER GUIDE: COLOR TOUCHSCREEN COMMUNICATING WITH HUMIDITY CONTROL THERMOSTAT. Outside Temperature (if installed) Room Temperature.

User Guide: *IG1605EW*

OWNER S MANUAL Venstar Inc. 08/07

Communicating Wall Control Owner s Manual TSTAT0101SC

81M26 81M27 81M28. User's Manual. Menu Driven Display DELUXE PROGRAMMABLE THERMOSTATS

User Guide: *IG1624EW*

Operation Guide CT80 ENGLISH

Read all instructions before proceeding. Store this manual for future reference

OWNER S MANUAL Venstar Inc. 08/07

ComfortNet CTK03 Thermostat Instructions Millbrook Apartments #4 Application

Auto-Changeover: A mode in which the thermostat will turn on the heating or cooling based on room temperature demand.

HEAT HEAT HEAT COOL COOL PUMP OWNER S MANUAL 7-DAY TOTALINE

ATC32U01 igate Communicating, Programmable Thermostat

RTH8500 Series. Quick Installation Guide. Included in your box. Programmable Thermostat. Quick Install Guide Screws and anchors. RTH8500 Thermostat

Safety & Installation Instructions

VisionPRO Series with RedLINK. User Guide

Programmable Touchscreen Thermostats. Read all instructions before proceeding. Store this manual for future reference

Energy Plannersm Programmable Thermostat Customer Guide. Take control of your comfort and energy savings

Thermostat Guide Online Guide Brighten Conservation Program. Personal Reference Guide. Brighten ithermostat

ComfortSense Model L7742U Thermostat. Display Fields & Touch Screen Points. Features. Description

4 Wiring Brochure Wiring and

INSTALLER'S SYSTEM SETUP GUIDE NOTICE

PROGRAMMING AND APPLICATION GUIDE IMPORTANT. ComfortSense 7000 Series. CONTROLS /08 Supersedes 05/08. Shipping and Packing List

Universal Programmable Wireless Thermostat Kit. See Wireless Setup Guide for Wireless Setup Instructions Read all instructions before proceeding

INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Color Touchscreen Communicating with Humidity Control Thermostat TPCC32U01

Auto-Changeover: Cool Setpoint: Deadband: Dehumidify: Differential: Heat Setpoint: Humidify: Icon: Mode: Non-Programmable Thermostat:

CONTROLS WI-FI THERMOSTAT. icomfort Wi-Fi Flex Thermostat PRODUCT SPECIFICATIONS

Zone Perfect Plus. Zoning Systems USER S INFORMATION MANUAL. NOTE TO INSTALLER: This manual must be left with the equipment user.

Honeywell CT8602 PROGRAMMABLE THERMOSTAT

User Guide ecobee ecobee 477 Richmond St West 2nd Floor, Toronto Ontario M5V 3E7 Canada Toll free

PROGRAMMING AND APPLICATION GUIDE IMPORTANT IMPORTANT. ComfortSense 7000 Series. CONTROLS /09 Supersedes 04/09. Shipping and Packing List

SAS6000UTK-7 UNIVERSAL THERMOSTAT

ELECTRONIC THERMOSTAT

DAY/TIME Button: Selects hour, minute and day setting.

DAY/TIME Button: Selects hour, minute and day setting.

TP-PHP01-A,TP-PAC01-A &TP- PRH01- B Performance Series Programmable Thermostat. Owner s Manual

Installation Instructions

INSTALLATION INSTRUCTIONS

CTS Series. Owner s Manual. Full Color Touch Screen Display. and Installation Instructions. High Resolution Digital Thermostat

Lyric T6 & T6R Smart Thermostat

Programmable Heat-Pump Thermostat TAYSTAT 540

COMF RT SYSTEM. T-32-TS Touchscreen Thermostat. User Manual

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

9801i 9815i 9820i. User's Manual. Menu Driven Display DELUXE PROGRAMMABLE THERMOSTATS. Humidity Sensing

LuxPro Thermostats NEW MULTI-STAGE TOUCHSCREENS. Features & Programming. Mt. Laurel, NJ

COMFORT CONTROL - 4 HEAT (GAS, OIL*, OR ELECTRIC)/3 COOL/HEAT PUMP COMMUNICATING PROGRAMMABLE 3 WIRE HOOKUP

Wiser Air User Interface Guide. Thermostat

HEAT HEAT HEAT COOL COOL

Commercial Touchscreen Thermostat

AIR CONDITIONER OPERATING MANUAL. Duct type. Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE. PART No.

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Lyric T6 Pro Wi-Fi. Professional Install Guide. Compatibility. Customer assistance. Programmable Thermostat

P200 Programmable Thermostat Installation Instructions & User Guide. For Installation Help. White-Rodgers.com

COMFORT CONTROL. Programmable Thermidistat Control Homeowner s Guide

DIGITAL THERMOSTAT Up To 2 Heat & 2 Cool Stages with Humidity Control

T8602C Chronotherm IV Deluxe Programmable Thermostats

Owner s Manual MODEL 8555

User's Manual. Menu Driven Display DELUXE PROGRAMMABLE THERMOSTATS

Operation 8085C ENGLISH. Customer Support: or Visit our webiste Printed in China

EWT-3102/EWT-3103 Touchscreen Programmable Thermostat

Must be installed by a trained, experienced technician

PSPA711/PSPA _PSPA711_722_MAN_ENG5.qxd 2/8/05 9:45 AM Page 2 1 COMPATIBILITY 3 ELECTRICAL RATINGS 2 FEATURES

OWNER'S MANUAL. How to operate your new Programmable Thermostat

Operation GT7000. Time / Current Temp. TEMP UP button. Display. Fan. Switch. Set Temp. Display. Mode Switch. Backlight. TEMP DOWN button.

RC-1000 and RC-2000 Programmable Communicating Thermostat. User s Guide

9901i 9915i 9920i. User's Manual. Menu Driven Display. Fresh Air Control DELUXE PROGRAMMABLE THERMOSTATS

Programmable Thermostat

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

T8611M Deluxe Programmable Heat Pump Thermostats

Safety & Installation Instructions

Transcription:

USER S INFORMATION MANUAL PREMIUM HIGH DEFINITION TOUCH SCREEN COMMUNICATING CONTROL MODELS: S1-TTSCC01 Energy Saver ABOUT YOUR COMMUNICATING CONTROL.......................... 2 Features......................... 2 QUICK REFERENCE............... 3 PROGRAMMING & OPERATION........ 5 DATE & TIME SETTINGS........... 5 SYSTEM SETTINGS............... 6 FAN SETTINGS................... 6 HUMIDITY SETTINGS.............. 7 Table of Contents SMART RECOVERY............... 8 ENERGY SAVER SETTINGS........ 8 USING PROGRAM SCHEDULES..... 8 TEMPERATURE OVERRIDE........ 13 SCHEDULE OVERRIDE............ 14 SPECIAL FEATURES.............. 15 APPENDIX......................... 20 LIMITED WARRANTY................ 20 Need Assistance? For assistance with this product please visit http://www.yorkupg.com Read and Save This Manual Johnson Controls Unitary Products 542937-UUM-A-1010

Never use sharp instruments, such as a pencil or pen, to press touch screen keys. To prevent damage to the thermostat, always press keys with your fingertip. Settings / Backlight Active Brightness: 50% 80% 100% Sleep Brightness: 1% 25% 80% Your brightness default settings are preset to maximize the life of your Communicating Control. Increasing the brightness levels could potentially decrease the life of the product. Brightness default settings for your Communicating Control are set: Active Mode Brightness 80% and Sleep Mode Brightness 25%. Features ABOUT YOUR COMMUNICATING CONTROL Large, Clear Display with Backlighting current temperature and temperature setpoint are easy-to-read and are displayed on the home screen. Intuitive Programming guides you through the scheduling process. Ability to Copy Multiple Days allows you to easily customize the Communicating Control for your unique schedule. Real-Time Clock keeps time during power failure; automatically updates for daylight savings. Precise Temperature Control (+/- 1 F) (+/-.5 C) reliable, consistent comfort. Multiple Hold/Override options allow you to modify schedule indefinitely or for a specific time. Change Reminders reminds you to replace and maintain air filters, humidifier pad, UV bulbs, and/or Electronic Air Cleaner filters. Outdoor Temperature Indication shows current outdoor temperature on the display to help you plan outdoor activities. NOTICE The Home and Menu screen may differ slightly, depending on your heating and/or cooling system and the Communicating Control s display settings. 2 Johnson Controls Unitary Products

QUICK REFERENCE Your new Communicating Control is preset to Non-Programmable View/Mode. To change the View Mode: Settings / View Mode Select a mode for the Thermostat: Non- Programmable Select a sleep screen: Home Programmable Temp Only Advanced Programmable 1. Press Menu in the bottom right corner of your screen. 2. Press Settings icon. 3. Press View/Mode icon. 4. Select Non-Programmable, Programmable or Advanced Programmable. The quick reference guide for each View/Mode is detailed in Figures 1-3. Current Date & Time Current Indoor Temperature Current Outdoor Temperature (if communicating outdoor equipment is installed) Temperature Setpoint Temperature Adjustment 72 11:07AM Thu 21 Jul 55 71 Humidity30% Humidity30% 72 ON Humidity Setting (if display setting is enabled) Fan Setting (if display setting is enabled) Quick Help Screen Lock Cool Mode FIGURE 1: Non-Programmable Mode Alert: Change Filter System Popup Alerts Heat Mode Menu Menu Current Indoor Humidity (if display setting is enabled) Johnson Controls Unitary Products 3

Current Date & Time Current Indoor Temperature Current Outdoor Temperature (if communicating outdoor equipment is installed) Temperature Setpoint Temperature Adjustment Quick Help 74 Screen Cool Lock Mode FIGURE 2: Programmable Mode 11:07AM Thu 21 Jul 55 72 Humidity30% Humidity30% 78 72 Alert: Change Filter System Popup Alerts CANCEL 74 to 10:00pm Heat Mode ON Menu Menu Program Override Timer (if an override is active) Humidity Setting (if display setting is enabled) Fan Setting (if display setting is enabled) Current Indoor Humidity (if display setting is enabled) Current Date & Time Current Indoor Temperature Current Outdoor Temperature (if communicating outdoor equipment is installed) Return to Home Screen Temperature Override Override Quick Help Screen Lock Cool Mode FIGURE 3: Advanced Programmable 11:07AM Thu 21 Jul 62 70 Humidity30% 78 Alert: Change Filter System Popup Alerts 72 CANCEL 75 to 10:00pm Heat Mode ON Menu Menu Program Override Timer (if an override is active) Humidity Setting (if display setting is enabled) Fan Setting (if display setting is enabled) Current Indoor Humidity (if display setting is enabled) 4 Johnson Controls Unitary Products

DATE & TIME SETTINGS 72 11:07AM Thu 21 Jul 55 71 Humidity30% 72 PROGRAMMING & OPERATION ON 1. Press Menu in the bottom right corner of your screen. Alert: Change Filter Menu 2. Press Settings icon. Emergency Heat Fan Humidity Status Settings Dealer Tools Clean Alert: Change Filter Close Settings 3. Press Date/Time icon. ; ç Date/Time Security Backlight Language View/Mode Temp F/ C Sound Maintenance Settings / Date/Time Date 08 May 2009 Clock 12 : 00 AM Clock Format 12 hr 24 hr Observe Daylight Savings Time Yes No 4. Select Date - current month, day and year. 5. Select Clock - current hour, minutes and AM or PM. 6. Select Clock Format (12hr or 24hr). 7. Select Daylight Saving Time (Yes or No). NOTE: 2007 and beyond, for areas that use the new 2007 DST calendar. 8. Press when you are done. Johnson Controls Unitary Products 5

SYSTEM SETTINGS Your Communicating Control is preset to OFF mode (neither heating or cooling modes are selected). In Non-Programmable mode, mode cannot be activated. If mode is desired, change the View/Mode to either Programmable or Advanced Programmable (see page 5 for details). 72 Emergency Heat 11:07AM Thu 21 Jul 55 71 Humidity30% 72 Alert: Change Filter Fan ON Menu Humidity Status Settings Off mode: Neither Heating or Cooling icons are illuminated. Heat mode: Heating icon is illuminated (red glow ring indicates heat equipment operation). Cool mode: Cooling icon is illuminated (blue glow ring indicates cool equipment operation). mode: Both Heating and Cooling icons are illuminated (red/blue glow ring indicates heat/cool equipment operation). Emergency Heat: Emergency Heat button is selected via the Menu screen (only for heat pumps with electric heat strips). Dealer Tools Clean Alert: Change Filter Close FAN SETTINGS In non-programmable mode, the fan setting defaults to the schedule currently active in the calendar. In programmable mode, the fan setting defaults to schedule mode. 1. Press Menu at the bottom right side of your screen. NOTICE Or press the quick access Fan icon on the right side of your screen. 6 Johnson Controls Unitary Products

Emergency Heat Fan Adjust Run fan Function: Fan Humidity Status Settings Dealer Tools Clean Alert: Change Filter xx% 45% 100% 30 minutes Per Hour Manual Close Show Fan on Home 2. Press Fan icon. 3. Select the Fan function. a. runs only with equipment. b. Manual runs intermittently to circulate air. NOTE: Manual mode is not available for all systems. i. Adjust the speed of your fan motor. NOTE: The lower the speed the less electricity consumed. ii. Select the fan run time. Choices are 15, 30, and 45 minutes per hour or Always. c. follows program schedule fan settings (see Page 9 for more information). NOTE: option is only available in programmable modes. 4. Select check box to display fan icon on home screen. 5. Press when you are done. HUMIDITY SETTINGS In non-programmable mode, your Communicating Control humidity setting defaults to auto mode. In programmable mode, the humidity setting defaults to schedule mode. 1. Press Menu. NOTE: Or press the quick access Humidity icon on the right side of your screen. 2. Press Humidity icon. 3. Select the Humidity mode. a. Humidification Select the Heat mode symbol. b. Dehumidification Select the Cool mode symbol. 4. Select Humidity function. a. matically sets the humidity setpoint based on indoor temperature. NOTE: mode requires an outdoor sensor. b. Manual Manually set the humidity setpoint. i. Select your desired indoor humidity percentage level. NOTE: If you start seeing condensation building up on your windows, lower the humidity setpoint or switch to auto mode. Humidity Adjust When Heating... Mode: c. Follows program schedule humidity settings (See Page 9 for more information). NOTE: option is only available in programmable modes. 5. Select check box to display humidity information on home screen. 6. Press when you are done. 22% Function: Humidity Adjust 22% When Heating... Mode: Function: Manual Manual 35% 45% 100% Show Humidity Level on Home Show Humidity Level on Home Johnson Controls Unitary Products 7

SMART RECOVERY Your Communicating Control comes with a feature called Smart Recovery, which eliminates all guesswork when setting your program schedule. How long does it take the furnace to warm your house in the morning before you get out of bed or how long does it take the air conditioner to cool your house in the afternoon before you return from work? The Communicating Control determines the equipment start time to satisfy your desired temperature setpoint. Simply set your program schedule to the time you want the house to be at your comfort temperature. The Communicating Control then turns on the heating or cooling at just the right time to have your home reach your comfort temperature at your scheduled time. For example: you get out of bed at 6:00 AM and want the temperature to be 70 F. Set the Awake period for 6:00 AM and 70 F. The Communicating Control will turn on the heat before 6:00 AM to raise the temperature to 70 F by 6:00 AM. ENERGY SAVER SETTINGS Energy Saver feature allows you to program your system for maximum energy savings. You can chose from two, three or four time periods each day, with different settings for each day. This Communicating Control is preset to use Energy Saver program settings. These settings would help reduce your heating/cooling expenses. Setpoints Setpoints Fan Setting Heat Cool Hum Dehum Awake (6:00 AM) 70 78 Day (8:00 AM) 62 85 Return (5:00 PM) 70 78 Sleep (10:00 PM) 62 82 USING PROGRAM SCHEDULES In a Non-Programmable mode, adjusting program schedule cannot be done. NOTICE In order to edit or run a program schedule, change the View/Mode to either Programmable or Advanced Programmable (see page 3 for details). Create or edit schedules Energy Saver New 1 2 Edit 3 Copy Delete Viewer Import/ Export Assign to Calendar 1. Press Menu. 2. Press icon. Save 8 Johnson Controls Unitary Products

Program Options 3. Press: a. The New, Edit or Copy icons to create a new or edit an existing schedule. Refer Page 9. b. The Delete icon to delete an existing schedule. Refer Page 12. c. The Viewer icon to view existing schedule summaries. Refer Page 12. d. The import/export icon to import or export a program schedule. Refer to Page 12. e. The Assign to Calendar icon to assign an existing schedule to the calendar. Refer Page 12. A. Creating New or Editing/Copying an Existing Name NAME DAY TIME TEMPERATURE FAN HUMIDITY Please name this schedule... 3 Edit Step 1 - Press Edit icon. a. Use the keyboard to name the schedule. b. Press. Step 2 - Press Next. Next Day NAME DAY TIME TEMPERATURE FAN HUMIDITY 3 Select day to edit: Mo Tu We Th Fr Sa Su Step 3 - Select Day to set schedule. Step 4 - Press Next. NOTE: Each program schedule is identified by a color. Color shades represent unique program schedule settings. Default settings based on Energy Saver Save + Quit Previous Next Time NAME DAY TIME TEMPERATURE FAN HUMIDITY Wed Number of Events: Select Event to edit: 2 3 4 Awake 6:00 am Save + Quit Day 9:00 am + 15 min 6:00 am - 15 min Return 6:00 pm Previous Sleep 10:00 pm Next Step 5 - Select Number of Events (2, 3 or 4 events per day). Step 6 - Select Event to set start time. Step 7 - Adjust time that corresponds to the event. Step 8 - Repeat steps 6-7 to select start time for other events. Step 9 - Press Next. Johnson Controls Unitary Products 9

Temperature NAME DAY TIME TEMPERATURE FAN HUMIDITY Wed Select Event to edit: Awake Day Return Sleep 73 70 73 70 73 70 73 70 Step 10 - Select Event to edit temperature setpoints. Save + Quit Previous Next / Temperature Adjust Adjust temperatures for Return 50% 65 100% 50 75 85 Step 11 - Adjust your Heating and Cooling setpoints. Step 12 - Select. Step 13 - Repeat steps 10-12 to program temperature for other events. Step 14 - Press Next. Fan NAME DAY TIME TEMPERATURE FAN HUMIDITY Wed Select Event to edit: Awake Day 85% Return Sleep 75% Step 15 - Select Event to edit fan settings. Previous Next / Fan Adjust Awake: Function Manual xx% 45% 100% Run fan Always Step 16 - Select the Fan function. a. b. Manual NOTE: Manual mode is not available for all systems. i. Adjust the speed of your fan motor. NOTE: The lower the speed the less electricity consumed. ii. Select the fan run time. Choices are 15, 30, and 45 minutes per hour or Always. Step 17 - Select. Step 18 - Repeat steps 15-17 to select fan mode for other events. Step 19 - Press Next. 10 Johnson Controls Unitary Products

Humidity Step 20 - Select the Humidity mode. a. Humidification select the Heat mode NAME DAY TIME TEMPERATURE FAN HUMIDITY symbol. b. Dehumidification select the Cool Wed Mode: %RH When Heating... mode symbol. Function: Manual Step 21 - Select the Humidity function. a. automatically sets the humidity xx% 45% 100% setpoint based on indoor temperature. NOTE: mode requires an outdoor sensor. b. Manual manually set the humidity setpoint. Previous Next i. Select your desired indoor humidity percentage level. Step 22 - Press Next. NOTE: Steps 3-22 illustrate how to set a single day s program schedule. You can copy this day to subsequent days (see Copy Day section below), or set another day by repeating steps 3-22. Copy Day NAME DAY TIME TEMPERATURE FAN HUMIDITY 3 Select day to edit: Mo Tu We Th Fr Sa Su Copy... Use Energy Saver Step 23 - Press Copy. Copy Day to... Save + Quit Select Day or Group to Apply Copied Day (We) Edit Mo Tu We Th Fr Sa Su Everyday Weekdays Weekends Step 24 - Select individual days, Weekdays, Weekend or Everyday. Step 25 - Press. Step 26 - Repeat steps 23-25 to copy settings to other days. Saving a Program Step 27 - Select Save + Quit. Johnson Controls Unitary Products 11

B. Deleting an Existing Program Delete? Step 1 - Press Yes. Delete this schedule? No Yes C. Viewing an Existing Program Viewer View 3 Awake 73 70 6:00am Day 73 70 8:00am (Active in Calendar) Mo Tu We Th Fr Sa Su Return 70 65 5:00pm Sleep 73 70 10:00pm Step 1 - Select to view by pressing left or right arrows. Step 2 - Select Day to view. Step 3 - Press Close. Close D. Importing / Exporting Program s Step 1 - Select Import or Export functionality. For Import Step 2 - Insert the USB into the bottom of the thermostat when prompted. Step 3 - When prompted that import is complete, remove USB from drive. Step 4 - Select after import is complete. For Export Step 1 - Step 2 - Insert the USB into the bottom of the thermostat when prompted. Step 3 - When prompted that export is complete, remove USB from drive. Step 4 - Select after export is complete. E. Assigning Program s to Calendar Select : Energy Saver 1 2 3 All Year Assign to Calendar Winter Spring Dec Jan Feb Mar Apr May June July Aug Sep Oct Nov Summer Fall Done Step 1 - Select to assign to calendar by pressing up or down arrows. Step 2 - Select individual months, Seasons, or All Year. Step 3 - Repeat steps 1-2 for each schedule's calendar assignment. Step 4 - Press Done. NOTE: In order to run a program schedule, it must be assigned to the calendar. 12 Johnson Controls Unitary Products

TEMPERATURE OVERRIDE Programmable Mode 72 Set Duration Hold until... led 11:07AM Thu 21 Jul 45 72 65 Humidity30% 08 : 01 PM Pick Duration Menu 1. Press temperature adjustment arrows either up or down until the desired override temperature setpoint is shown. 2. Press Pick Duration button. 3. Select the duration for running the temperature override. a. Until led holds temperature until cancelled. b. Until specific Date & Time holds temperature until specified date and time. c. Until program schedule Next Event hold temperature until next schedule event. Next Event 8:00 am Advanced Programmable Mode Set Duration Hold until... led Next Event 8:00 am 11:07AM Thu 21 Jul 75 Quick Pick Duration Quick 70 50 85 Alert: Change Filter Menu 08 : 01 PM 1. Press Thermometer icon. 2. Use the slider to set the desired override temperature. 3. Press Pick Duration button. 4. Select the duration for running the temperature override. a. Until led holds temperature until cancelled. b. Until specific Date & Time holds temperature until specified date and time. c. Until program schedule Next Event hold temperature until next schedule event. Quick Heat / Quick Cool 1. Press Thermometer icon. 2. Select Quick Heat / Quick Cool icon runs heat/cool equipment at maximum capacity for 10 minutes. Johnson Controls Unitary Products 13

SCHEDULE OVERRIDE Advanced Programmable Mode 1. Press icon. 2. Select: a. The current program schedule (NOW) event to extend the duration. b. The desired program schedule (OVERRIDE) event to override with a future event. c. The Set Vacation to setup a Vacation Override. A. Extend Current Program Event 5:37PM Thu 21 Jul Set Vacation... View... NOW Extend NOW or change to... Day 78 70 Sleep 82 62 Awake 78 70 Day 85 62 8:00am 10:00 pm 6:00 am 8:00 am Menu B. Change to Future Program Event To extend the current program schedule event's settings (temperature, fan, and humidity) beyond the scheduled event time, perform the following: Step 1 - Select current program schedule event (NOW shown in highlighted box). Step 2 - Press. Step 3 - Select the duration for running the schedule override. Step 4 - Until led permanent hold. a. Until specific Date & Time. b. Until program schedule Next Event. 9:07AM Thu 21 Jul Set Vacation... View... NOW OVERRIDE Awake Day Return Sleep 73 70 73 70 78 64 70 67 9:00am 10:00 am 6:00 pm 11:30 pm Menu Arrive home from work early? To initiate a future program schedule event's settings (temperature, fan, and humidity) prior to the scheduled event time, perform the following: Step 1 - Select desired program schedule event (OVERRIDE shown in highlighted box). Step 2 - Press. C. Vacation Override Vacation For how long? Leave 08 Return 10 May May 2009 2009 10 10 AM AM Step 1 - Select number of Days or Step 2 - Select Vacation Dates: a. Leave Date - current month, day and year. b. Return Date - current month, day and year. c. Press Next. Days 2 Next 14 Johnson Controls Unitary Products

Vacation Set Temperatures 50% 65 100% Step 3 - Adjust your Heating and Cooling setpoints. Step 4 - Press Next. 50 76 85 Previous Vacation Set Fan Function: Manual Next Step 5 - Adjust your Fan setting. Step 6 - Press Next. Previous Next Vacation Set Humidity When Heating... Mode: Function: Manual 15% 45% 50% Step 7 - Adjust your Humidity settings. Step 8 - Press Done. Step 9 - Press. Previous Done SPECIAL FEATURES Equipment Status Equipment Status feature is used to help you understand your heating and cooling system better. Here are some of the highlights of this feature. Johnson Controls Unitary Products 15

Equipment Conditions Status 11:07AM Thu 21 Jul Touch ICON for a detailed view Heat Pump OFF Exit Service Mode Thermostat ON Humidifier ON UV Lamps ON EAC Not Installed Furnace ON 1. Press Menu. 2. Press Status icon. Refresh Accessories Log Menu Back Using the system map, you can determine your equipment conditions. The color GREEN means your equipment is performing as expected without any concerns. YELLOW, that particular piece of equipment requires some attention but not urgently. When equipment status is highlighted in RED, it needs immediate attention. Equipment marked in a GRAY color is not installed and is offered to maximize your comfort and indoor air quality. For more information on equipment highlighted in GRAY color, contact your installing dealer for more details. Equipment Operational State For detailed information on the current operational state of your heating or cooling equipment, you can refer to the Equipment Status screen. It displays status information about your indoor unit (air handler or furnace) and your outdoor unit (heat pump or air conditioner) at any given time. Not all equipment information is shown for all systems. Equipment Service Reminders This feature displays an alert to remind you to change the air filter, humidifier pad, UV lamps or service your electronic air cleaner. To activate, follow these steps. Settings / Maintenance Air Filter: Cumulative Hours Months 6 Months Humidifier Pad: Cumulative Hours Months 15,000 Hours NOTICE 1. Press Menu. 2. Press Settings icon. 3. Press Maintenance icon. 4. Air Filter, select either Cumulative Hours or Months. Adjust the period per the manufacturer recommendation. 16 Johnson Controls Unitary Products

Settings / Maintenance UV Lamps: Cumulative Hours Months Electronic Air Cleaner: 6 Months Cumulative Hours 15,000 Hours Months 5. Humidifier Pad, select either Cumulative Hours or Months. Adjust the period per the manufacturer recommendation. 6. Using the bar to the right of the screen, scroll down to view other equipment. 7. UV Lamps, select either Cumulative Hours or Months. Adjust the period per the manufacturer recommendation. 8. Electronic Air Cleaner, select either Cumulative Hours or Months. Adjust the period per the manufacturer recommendation. 9. Press when you are done. Expired Service Reminders Event Call Your Dealer: Replace UV lamps in 1 month Model 1138 12:32 AM Thu 9/17 1. Select action for expired Service reminder. a. Reset reset service alert timer. b. Remind Later specify days to notify later. Log Dealer Remind Later Reset Reset Were the UV lamps replaced? A. Reset Step 1 - After replacing consumable, select YES to reset the reminder timer. Step 2 - Press. Yes Alert Remind me again in... Days 08 B. Remind Later Step 1 - To be reminded at a later date, set duration of days using up and down arrows. Step 2 - Press. Johnson Controls Unitary Products 17

Trilingual Communicating Control Your Communicating Control s language is preset to English. It comes equipped with 2 other languages to choose from. To switch to a different language, follow these steps. Settings / Language Language English Español Français 1. Press Menu. 2. Press Settings icon. 3. Press Language icon. 4. Make your language selection. 5. Press. Temperature Format Your Communicating Control s temperature format is preset to Fahrenheit. To switch to Celsius temperature format, follow these steps. Settings / Temperature Temperature F/ C Fahrenheit Celsius 1. Press Menu. 2. Press Settings icon. 3. Press Temp F/C icon. 4. Make your temperature format selection. 5. Press. Done Dealer Contact Information Your installer dealer/contractor contact information can be stored in your Communicating Control. To view your dealer/contractor contact information, follow these steps. 1. Press Menu. 2. Press Dealer icon. 18 Johnson Controls Unitary Products

Screen Lock Emergency Heat Fan Humidity Status Settings To prevent tampering with your Communicating Control, the screen can be fully locked. To activate the screen security setting, follow these steps: Dealer Tools Clean Alert: Change Filter Close Settings Date/Time Security Backlight Language ; ç 1. Press Screen Lock button on the Home screen or 2. Press Menu, Press Settings icon, and Press Security icon. View/Mode Temp F/ C Sound Maintenance Settings / Security Security OFF ON Change PIN 3. Press ON icon to activate screen lock settings. 4. Press. a. You will be prompted to enter your new PIN number if you have not already done so. Locked Please enter PIN 8888 1 2 3 4 5 6 7 8 9 Bksp 0 5. Press. Your screen security is now activated. Make sure you remember your pin number. Johnson Controls Unitary Products 19

Screen Cleaning 1. Press Menu. Emergency Heat Fan Humidity Status Settings Dealer Tools Clean Alert: Change Filter Close TOUCH SCREEN DISABLED to clean screen now. :15 Press and Hold to Exit 2. Press Clean icon to lock the screen for cleaning. The screen will remain locked for 15 seconds to allow you to clean the screen without changing any settings. After 15 seconds, normal screen operation will resume. If more time is needed for cleaning, repeat steps 1 and 2 above. NOTICE Do not spray any liquid directly on the thermostat. Spray liquids onto a cloth, and then use the damp cloth to clean the screen. Use water or household glass cleaner. Do not use abrasive cleansers. APPENDIX Frequently Asked Questions and Answers. Q: Next to Fan on the Home screen, or On is shown. What does this mean? A: The Fan is set for (to run with equipment) or On (to circulate air in your home). See Fan Settings on page 9 for more information. Q: Why doesn t the Communicating Control respond when I touch the keys? A: Check to determine if the screen is in the Locked or Clean mode. See Screen Lock on page 28 or Screen Cleaning on page 29. Subject to change without notice. Published in U.S.A. Copyright 2010 by Johnson Controls, Inc. All rights reserved. Johnson Controls Unitary Products 5005 York Drive Norman, 73069 542937-UUM-A-1010 Supersedes: Nothing