Innovative Hybrid Heat Pump for Dryer Process Integration

Similar documents
Minimising Energy Use in Milk Powder Production using Process Integration Techniques

A New Graphical Approach for Heat Exchanger Network Retrofit Considering Capital and Utility Costs

Shortcut Model for Predicting Refrigeration Cycle Performance

CASE STUDIES OF THERMALLY DRIVEN HEAT PUMP ASSISTED DRYING. Minh Cuong Tran, Jamy Logie, Bruno Vanslambrouck, Martijn van den Broek

Identification of the Most Effective Heat Exchanger for Waste Heat Recovery

Modelling of divided wall column

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

A Novel Freeze Drying Process by Using Self-Heat Recuperation Technology

Feasibility study on an energy-saving desiccant wheel system with CO 2 heat pump

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Low Temperature Separation Systems. Separation Process

Modelling the Performance of a Diffusion Absorption Refrigeration System

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

*Corresponding author;

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

ENERGY ANALYSIS OF HEAT PUMP WITH SUBCOOLER

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

POTENTIAL OF NON - AZEOTROPIC REFRIGERANT MIXTURE AS WORKING REFRIGERANT IN HOT WATER HEAT PUMPS. FJ Smit and JP Meyer

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

Effect of the Outlet Air Reuse on Thermal Efficiency of a Pilot Plant Spray Dryer with Rotary Atomizer

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

DEVELOPMENT OF A DYNAMIC HEAT PUMP DRYER TEST BENCH TO DEMONSTRATE ENERGETICAL OPTIMIZATION POSSIBILITIES BY REPLICATING REAL LIFE DRYING PROCESSES

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

Dynamic performance of a novel dew point air conditioning for the UK buildings

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Heat Pump Fluidised Bed Dryer with CO 2 as Refrigerant Measurements of COP and SMER

Evaluation of Sorbents at Elevated Temperatures for Downhole Application

MODELLING AND OPTIMIZATION OF DIRECT EXPANSION AIR CONDITIONING SYSTEM FOR COMMERCIAL BUILDING ENERGY SAVING

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

EXPERIMENTAL PERFORMANCE ANALYSIS OF AN AMMONIA-WATER DIFFUSION ABSORPTION REFRIGERATION CYCLE

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Thermodynamics: Homework A Set 7 Jennifer West (2004)

Experimental Investigation of a New High Temperature Heat Pump Using Water as Refrigerant for Industrial Heat Recovery

Chapter 10. Refrigeration and Heat Pump Systems

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance Analysis of Solar Assisted Cascade Refrigeration System of Cold Storage System

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Thermodynamic Calculations of Two-Stage Vapor Compression Refrigeration Cycle with Flash Chamber and Separate Vapor Mixing Intercooler

Reducing energy consumption of airconditioning systems in moderate climates by applying indirect evaporative cooling

Pressure Enthalpy Charts

Analysis of freeze protection methods for recuperators used in energy recovery from exhaust air

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

REFRIGERATION CYCLES

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

Experimental Study on Compact Heat Pump System for Clothes Drying Using CO 2 as a Refrigerant. Abstract

Impact of indirect evaporative air cooler type on the performance of desiccant systems

Homework Chapter2. Homework Chapter3

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

Available online at Energy Procedia 6 (2011) MEDGREEN 2011-LB

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

An industrial Heat Pump for Steam and Fuel Savings

Evaluation of a dynamic model for a cold climate counter flow air to air heat exchanger

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

REFRIGERATION CYCLES

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

HFCs or the Old Refrigerants - what is the best Choice?

SIMULATION OF A NEW TYPE GAS-FIRED AIR-COOLED AIR-CONDITIONER. Lin Wang, Xing Xu, Aihua Ma, Yonghui Guo and Xiwen Zhou

PERFORMANCE OF EARTH TUBE HEAT EXCHANGER COOLING OF AIR A REVIEW

Desiccant Cooling with Solar Energy

Feasible Working Domains Decision Support for Heat Pump Projects

Recent Advances in Energy, Environment and Economic Development

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

Transcritical Carbon Dioxide Microchannel Heat Pump Water Heaters: Part II - System Simulation and Optimization

Modelling of End-use Electricity Consumption and Saving Potential in Household Sector in Northern Thailand

POLYMER HOLLOW FIBRE HEAT EXCHANGERS

Application of two hybrid control methods of expansion valves and vapor injected compression to heat pumps

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Chapter 11 REFRIGERATION CYCLES

VAPOR COMPRESSION HEAT PUMP USING LOW TEMPERATURE GEOTHERMAL WATER: A CASE STUDY OF NORTHERN THAILAND

Simulation Of Pneumatic Drying: Influence Of Particle Diameter And Solid Loading Ratio

Performance investigation of Air-conditioning system using ejector as expansion device

Woody Biomass Fuel Drying

Transcription:

1039 A publication of CHEMICAL ENGINEERING TRANSACTIONS VOL. 57, 2017 Guest Editors: Sauro Pierucci, Jiří Jaromír Klemeš, Laura Piazza, Serafim Bakalis Copyright 2017, AIDIC Servizi S.r.l. ISBN 978-88-95608-48-8; ISSN 2283-9216 The Italian Association of Chemical Engineering Online at www.aidic.it/cet DOI: 10.3303/CET1757174 Innovative Hybrid Heat Pump for Dryer Process Integration Timothy G. Walmsley* a, Jiří J.Klemeš a, Michael R.W. Walmsley b, Martin J.Atkins b, Petar S.Varbanov a a Sustainable Process Integration Laboratory SPIL, NETME Centre, Faculty of Mechanical Engineering, Brno University of Technology - VUT Brno, Technická 2896/2, 616 69 Brno, Czech Republic b Energy Research Centre, School of Engineering, University of Waikato, Private Bag 3105, Hamilton, New Zealand walmsley@fme.vutbr.cz This study aims to simulate and optimise a hybrid compression-absorption heat pump process for convective dryers considering Pinch design principles. With a greening electricity grid, heat pumps represent an effective technology to reduce process heat emissions. As a result, numerous types of heat pumps integrated with convective dryers have been reported in the literature, but no study was found to use a hybrid heat pump. To simplify the design and optimisation, Process Integration principles for compressors and expanders from literature are synthesised into a Pinch design method for heat pumps. A milk spray dryer case study is analysed. Simulation results using Petro-Sim TM show that the optimally design hybrid heat pump system can reduce dryer energy demand by 47.3 % and total emissions by 42.4 % (assuming a low carbon electricity grid) while achieving a gross Coefficient of Performance of 4.53. Future work will look at optimising the selection and composition of working fluid for the hybrid heat pump system as well as investigating the economics of its implementation in industry. 1. Introduction Convective dryers are an energy intensive process unit operation required by several industries, e.g. pulp and paper, wood, food and beverage, and pharmaceutical. In most instances, fresh air is drawn into the system and heated to a set temperature. The hot dry air enters the dryer and removes moisture from the liquid or solid feed such that the exhaust air is humid and warm. Separation operations then remove entrained particulates from the exhaust air. The dryer operation may include multi-staged drying operations to provide a longer residence time to extract sufficient water from the core of the product while also cooling the product. Within the dryer system boundary, some exhaust air may be recycled to further increase dryer energy efficiency by reaching a lower exhaust temperature and higher absolute humidity. With the prospect of a renewable electricity future, heat pumps are emerging as a key technology to enable a step reduction in process heat emissions and associated fossil fuel consumption. The idea of using heat pumps to integrate convective dryers has been investigated in numerous studies (Minea, 2013). Heat pump cycles considered for dryers include: vapour compression and transcritical cycles (Wang and Cleland, 2011), open absorption cycles (Anderson and Westerlund, 2014), closed absorption cycles (Tran et al., 2016), and solar assisted cycles (Suleman et al., 2014). Wang and Cleland (2011) studied a milk spray dryer finding a transcritical R-134a cycle achieved the highest Coefficient of Performance (COP). One emerging heat pump technology is a hybrid vapour compression-absorption heat pump. In this cycle, elements of the vapour compression cycle and absorption cycle are combined. The cycle uses a binary fluid, e.g. ammonia-water. Using a binary fluid results in significant temperature glide for evaporator and condenser heat transfer operations. As a result working fluid composition may be selected to achieve different temperature glide profiles that match process heat demand profiles. For this cycle, the evaporator outlet is a vapour-liquid mixture, requiring a separator connected to a compressor and a pump to raise the pressure of the working fluid. The application of hybrid vapour compression-absorption heat pump for dryer integration represents a gap in the literature. Please cite this article as: Walmsley T.G., Klemes J.J., Walmsley M.R.W., Atkins M.J., Varbanov P.S., 2017, Innovative hybrid heat pump for dryer process integration, Chemical Engineering Transactions, 57, 1039-1044 DOI: 10.3303/CET1757174

1040 Early in the development of Pinch Analysis, Townsend and Linnhoff (1983) introduced the idea of the appropriate placement of heat pumps, which states that heat from the below the Pinch should be upgraded to satisfy demands above the Pinch (Klemeš, 2013). This principle holds true for all types of heat pumps including in applications, including open cycle systems (Walmsley et al., 2016). For heat pump design, it is useful to apply appropriate placement principles for individual components. Through exergy analysis, Fu and Gundersen (2015) derived rules for the appropriate placement of compression and expansion operations. Consequently, close matching of heat load profiles is desirable from an exergy transfer viewpoint to minimise exergy destruction and thereby aim to reduce the work of compression and/or high-quality heat inputs (Fu and Gundersen, 2016). These principles can also be applied to the Pinch design of the hybrid vapour compression-absorption heat pump for dryers. This paper aims to simulate and optimise a hybrid compression-absorption heat pump process for convective dryers considering Pinch design principles. The process simulation is modelled using Petro-Sim TM (KBC, 2016). A milk spray dryer case study demonstrates the application of a hybrid heat pump. 2. Dryer process integration schemes Four methods for dryer process integration are illustrated in Figure 1. Option A is direct heat recovery of the exhaust air to the inlet air (or another cold process stream, if available). A barrier to implementing this method is the distance between the exhaust air stream and the fresh air intake, which for a milk spray dryer it s desirable to separate the inlet and exhaust ducts. In such cases, a liquid coupled loop heat exchanger system may be installed to allow for exhaust-inlet separation and simpler retrofit (Option B). Options A and B can recover similar levels of heat, about 15% of the air heater duty for milk spray dryers (Walmsley et al., 2015), but are limited by the exhaust temperature, which drives the Pinch Temperature. Option C adds a heat pump to the system. However, the capital cost for the system greatly increases as the number of heat exchangers increases to four as well as a compressor. Option D, although less thermodynamically efficient, synthesises the liquid coupled loop system with the heat pump to combine benefits and reduce capital cost. This solution follows the appropriate placement of a heat pump principle if the dryer exhaust and inlet air are considered as separate zones. This study focuses on Option D. Figure 1: Typical dryer exhaust-to-inlet air flow process integration schemes. 3. Methods 3.1 Pinch principles for heat pump cycle design for a dryer Appropriate placement principles for heat pump components may be synthesised into a Pinch design method for a hybrid heat pump (Figure 2). Fu and Gundersen (2015) show the appropriate placement of a compressor starts at the Pinch providing heat above the Pinch. An expander is appropriately placed starting at the Pinch and providing cooling below the Pinch. These principles are applied to the design of a hybrid compressionabsorption heat pump as shown in Figure 2. Since the exhaust and inlet air streams are treated as two zones, the shifted exhaust temperature drives the hot Pinch and the cold inlet air determines the cold Pinch. Accordingly, the inlet of the compressor/pump is ideally T ExAir T min and the inlet of the expansion valve is T InAir + T min. There is the further constraint that the outlet of the condenser is 100 % liquid (saturated or subcooled). The heat profiles of the working fluid in the evaporator and condenser are affected by the composition of the fluid. 3.2 Hybrid vapour compression-absorption heat pump simulation model A hybrid vapour compression-absorption heat pump simulation has been undertaken in Petro-Sim TM as shown in Figure 3. The binary working fluid is ammonia-water. Fluid properties are based on the Peng-Robinson formulation in combination with the Lee-Kesler equation of state as a standard package in PetroSim.

Very low-quality vapour (~5 %) ammonia-water fluid enters the evaporator. As heat is transferred from the exhaust air (ExAir), significant temperature glide occurs generating a vapour phase rich in ammonia and a liquid phase rich in water that exits the evaporator. The evaporator outlet temperature is T ExAir T min. The vapour and liquid phases are then separated and appropriately supplied to the compressor and pump. After the mixer, high quality (~75 %) saturated vapour condenses to saturated liquid ammonia-water, once again with significant temperature glide. At this point, the model uses a recycle operation to break the cycle so that the conditions of S-010 may be specified, i.e. saturated liquid and selected temperature. Mass flow rate of the working fluid automatically adjusts to achieve a target T min for the condenser. Saturated liquid then sub-cools to T InAir + T min. The fluid completes the cycle by passing through the expansion valve returning to the evaporator. 1041 Figure 2: Pinch design of a hybrid heat pump cycle and its components integrated with a dryer exhaust and inlet air streams. Figure 3: A Simulation model of a hybrid vapour compression-absorption heat pump in Petro-Sim.

1042 The simulation requires four specified inputs to solve: (1) binary fluid composition, (2) heat exchanger approach temperature, T min, (3) the saturation temperature (or pressure) at the outlet of the condenser, and (4) the evaporator inlet temperature (or pressure). For this study, T min is set at 15 C for all heat exchangers and the binary fluid is 80 mol% ammonia 20 mol % water. The pump has an estimated 75% isentropic efficiency and the compressor has an efficiency based on the required compression ratio (Wang and Cleland, 2011) using 2 ( 0 65 + 0. 015r 0. 0015r ), Po η comp = ηmotorηisen = ηmotor. where ηmotor = 0. 98, r = (1) P 3.3 Energy and emissions performance coefficients A number of ratios are defined to characterise heat pump performance. The gross Coefficient of Performance, COP gross, for the dryer heat pump, is QHP COP gross =, where QHP = QSub + QCond (2) W However, it s important to recognise that not all of the heat delivered by the heat pump, Q HP, required upgrading. Some of the heat, Q HR,tar, could have alternately been recovered using a liquid coupled loop system. As a result, a COP net based on the required heat pump contribution is i COP net QHP QHR,tar = (3) W The proportion of process heat demand, Q demand, satisfied by the heat pump system, α HP, is QHP 1 α HP = =, where Qdemand = QHP + QAH (4) Q 1+ Q Q demand AH HP A detailed analysis of heat pump integration impact on emissions is also undertaken using average Emission Factors (EF). For this study, the Emissions Reduction ratio (ER), which is the ratio of emissions reduction per unit of dryer heat demand, is Q ER = HP EF Q heat demand W GEF GEF EFfuel α 1 = HP 1, EFheat = EF heat COP gross EF where (5) heat ηboiler The study assumes as a base case that steam from a natural gas boiler with an 85 % efficiency heats inlet dryer air to 200 C from an average of 15 C. A typical EF fuel for natural gas is 53.3 kg CO2-e /kj f (Ministry for the Environment, 2007). The EF heat for process heat is 62.7 kg CO2-e /MJ after accounting for boiler efficiency. Heat pumps replace process heat from fossil fuel for process heat from electricity at the ratio of the COP gross. Current global aspirations are to move towards renewable, low carbon national and regional electricity grids. As a representative renewable electricity grid, New Zealand has 82.6% renewable generation and a Grid Emissions Factor (GEF) of 29.5 kg CO2-e /MJ in 2016 (MBIE, 2016). 4. Milk spray dryer case study A milk spray dryer case study provides the contexts for demonstrating the application of a hybrid vapour compression-absorption heat pump. The main dryer inlet air enters at 15 C and a humidity of 5 g/kg DA. The heat pump in combination with a steam heater then raises its temperature to 200 C. The exhaust air, which includes air from the spray dryer and associated fluidised beds, exits at 75 C and 47 g/kg DA, which is a dew point temperature of 39.5 C. The mass flow rate ratio of total exhaust air to dryer inlet air is 1.25 kg/kg. 5. Results and discussion 5.1 Effect of condenser and evaporator temperature selection on performance Multiple combinations of condenser saturation temperature (40 80 C) and evaporator inlet temperature (15 25 C) have been simulated using the hybrid heat pump model as shown in Figure 4. These results apply a T min of 15 C for all heat exchangers and a binary fluid with 80 mol% ammonia 20 mol% water. COP net (Figure 4B) shows a peak value for the selected evaporator inlet temperatures when the condenser saturation

1043 temperature is about 55 C. The highest COP net is achieved for an evaporator inlet temperature of 25 C; however, this is also for the lowest α HP, which is equivalent to the amount of steam utility reduction. Figure 4: Effect of condenser and evaporator temperature specifications on performance. A B 120 120 100 100 T min Temperature [ C] 80 60 40 Exhaust Air Evaporator T min Temperature [ C] 80 60 40 Condenser Inlet Air 20 20 0 0 20 40 60 80 100 Enthalpy [MJ/t InAir ] 0 0 20 40 60 80 100 Enthalpy [MJ/t InAir ] Figure 5: Optimised heat load profiles for a binary fluid with 80 mol% ammonia 20 mol% water.

1044 5.2 Maximum energy and emission reduction through optimal temperature selection Energy and emission reductions for a hybrid heat pump dryer may be maximised through optimal selection of condenser saturation temperature, evaporator inlet temperature, as well as evaporator outlet temperature. In the previous simulations, the evaporator outlet temperature was fixed at 60 C, i.e. T ExAir T min, following the Pinch design principle. The optimisation problem set a target COP net of 3.0. This constraint ensured a minimum performance level for the objective of maximising energy and emission reductions. In the Petro-Sim optimisation, the condenser saturation temperature converges to 71.2 C and the evaporator inlet temperature to 19.4 C. Lifting the constraint for evaporator outlet temperature also confirmed that 60.0 C is indeed the optimal temperature for the evaporator outlet given a T min of 15 C. The heat load profiles for the evaporator (A) and condenser (B) are presented in Figure 5. Using ammonia-water as the working fluid allows excellent matching between heat load profiles, especially in the evaporator, thus minimising exergy destruction. For the optimised design, the compression ratio is 4.07 with a compressor efficiency of 67.3 %. The heat pump substitutes 47.3 % of the air heat duty with 42.4 % emissions reductions. 6. Conclusions This study simulated a hybrid vapour compression-absorption heat pump using a milk spray dryer as the case study. Pinch design principles for a heat pump, including its key components, are synthesised from literature. Results confirm the validity of these Pinch design principles. With an optimal design for the case study, the hybrid heat pump decreased utility heater load by 47.3 % and total emissions by 42.4 %. Future work will look at optimising the selection and composition of working fluid for the hybrid heat pump system as well as investigating the economics of its implementation in industry. Acknowledgments This research has been supported by the project Sustainable Process Integration Laboratory SPIL, project No. CZ.02.1.01/0.0/0.0/15_003/0000456 funded by EU CZ Operational Programme Research and Development, Education, Priority 1: Strengthening capacity for quality research. Reference Anderson J.O., Westerlund L., 2014, Improved energy efficiency in sawmill drying system, Applied Energy 113, 891 901. Fu C., Gundersen T., 2016, A Novel Sensible Heat Pump Scheme for Industrial Heat Recovery, Ind. Eng. Chem. Res. 55, 967 977. Fu C., Gundersen T., 2015, Integrating compressors into heat exchanger networks above ambient temperature, AIChE J. 61, 3770 3785. KBC, 2016, Petro-Sim, KBC Advanced Technologies, London, UK. Klemeš J.J., Ed., 2013, Handbook of Process Integration: Minimisation of energy and water use, waste and emissions, Woodhead Publishing/Elsevier, Cambridge, UK. Minea V., 2013, Drying heat pumps Part I: System integration, International Journal of Refrigeration 36, 643 658. MBIE (Ministry of Business, Innovation and Employment, New Zealand), 2016, Energy Statistics Electricity <www.mbie.govt.nz/info-services/sectors-industries/energy/energy-data-modelling> accessed 12.14.2016. MfE (Ministry for the Environment, New Zealand), 2007, Emission factors and methods 2007 <www.mfe.govt.nz/publications/climate/guidance-greenhouse-gas-reporting-2008-09/html/page3.html> accessed 12.14.2016). Suleman F., Dincer I., Agelin-Chaab M., 2014, Energy and exergy analyses of an integrated solar heat pump system, Applied Thermal Engineering 73, 559 566. Townsend D.W., Linnhoff B., 1983, Heat and power networks in process design. Part I: Criteria for placement of heat engines and heat pumps in process networks, AIChE J. 29, 742 748. Tran M.C., T Jollyn I., Logie J., Broek M. van den Paepe M.D., Vanslambrouck B., 2016, Performance of heat pump drying system integrated into a blood dryer, Drying Technology 34, 1677 1689. Walmsley T.G., Atkins M.J., Walmsley M.R.W., Neale J.R., 2016, Appropriate placement of vapour recompression in ultra-low energy industrial milk evaporation systems using Pinch Analysis, Energy 116, Part 2, 1269 1281. Walmsley T.G., Walmsley M.R.W., Atkins M.J., Neale J.R., Tarighaleslami A.H., 2015, Thermo-economic optimisation of industrial milk spray dryer exhaust to inlet air heat recovery, Energy 90, Part 1, 95 104. Wang J.F., Cleland D.J., 2011, Heat pump heat recovery options for dryers in the food industry, Proceedings of the 23rd IIR International Congress of Refrigeration, Paper 418, Prague, CZ.