TECHNICAL DATA OBSOLETE

Similar documents
FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK457 (K4.9) TECHNICAL DATA

FREEDOM RESIDENTIAL CONCEALED PENDENT LEAD FREE SPRINKLER VK4570 (K4.9) TECHNICAL DATA

freedom residential concealed pendent sprinkler VK488 (K3.0)

freedom residential concealed pendent Sprinkler vk458 (K7.4)

freedom residential concealed pendent lead free sprinkler

TECHNICAL DATA. * Metric K-factor measurement shown is in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0.

HORIZON MIRAGE QUICK RESPONSE LARGE ORIFICE CONCEALED PENDENT SPRINKLER VK406 TECHNICAL DATA

freedom residential concealed pendent sprinkler vk474 (K5.8)

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

Quick response concealed horizontal sidewall sprinkler VK481

FREEDOM RESIDENTIAL CONCEALED HORIZONTAL SIDEWALL SPRINKLER VK480 TECHNICAL DATA

TECHNICAL DATA. The Viking Corporation s Web site at Overall Length (Sprinkler Body): 2-5/16 (59 mm)

sprinkler vk538 (K11.2)

TECHNICAL DATA. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Chart.

Page 1 of 7. Replaces Form No. F_ Rev 16.3 (Added 16X22 and 18X20 coverage areas)

Standard Spray concealed horizontal sidewall sprinkler VK481

mirage Quick response concealed pendent sprinkler vk464 (K8.0)

mirage Quick response extended coverage concealed pendent sprinklers (vk632 and vk634)

TECHNICAL DATA. Viking Technical Data may be found on Maximum Working Pressure: 175 psi (12 Bar).

STANDARD/quick. Sprinkler 42o. August 8, 2011

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

mirage Quick response concealed pendent sprinkler vk465 (K4.2)

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9) TECHNICAL DATA

standard response sprinklers (vk102 & vk202) 3. technical data Specifications: Minimum Operating Pressure: 7 psi (0.5 bar) Sprinkler 11j

HORIZON QUICK RESPONSE FLUSH PENDENT SPRINKLERS TECHNICAL DATA

MIRAGE EC/QREC OH-ELO CONCEALED PENDENT SPRINKLER VK538 (K11.2) TECHNICAL DATA

mirage standard response concealed pendent sprinkler vk492 (K5.6)

Page 1 of 7. Form No. F_ Rev Replaces Form No. F_ Rev 17.1 (added 205deg version)

quick response sprinkler vk194 Sprinkler 104j January 1, 2011

standard response/qr extended coverage concealed pendent sprinklers vk614 & vk616

QUICK RESPONSE DRY CONCEALED PENDENT SPRINKLER VK194 TECHNICAL DATA

freedom residential flush pendent sprinkler vk476 (K4.9)

FREEDOM RESIDENTIAL CONCEALED PENDENT SPRINKLER VK498 (K5.8) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE CONCEALED HSW SPRINKLER VK630 (K8.0) TECHNICAL DATA

freedom residential horizontal sidewall sprinkler Vk450 (k4.2)

Form No. F_ Rev 14.1 Page 1 of 6 TECHNICAL DATA

standard/quick response sprinklers (vk302 & vk352) 3. technical data Specifications: Available since Sprinkler 41g May 1, 2009

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK468 (K4.9) TECHNICAL DATA

TECHNICAL DATA OBSOLETE

December 14, 2015 Page 1 of 7 TECHNICAL DATA

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK486 (K4.0) TECHNICAL DATA

TECHNICAL DATA. Viking Technical Data may be found on UNS-C84400 for Sprinkler VK202.

STANDARD/QUICK RESPONSE CONCEALED PENDENT SPRINKLER VK352-D (K8.0) TECHNICAL DATA

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD TECHNICAL DATA ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK479 (K3.0) TECHNICAL DATA

STANDARD/QR EXTENDED COVERAGE LIGHT HAZARD ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK617 TECHNICAL DATA

freedom residential pendent sprinkler vk466 (K5.2)

FREEDOM RESIDENTIAL HORIZONTAL SIDEWALL SPRINKLER VK460 (K5.8) TECHNICAL DATA

FREEDOM RESIDENTIAL PENDENT LEAD FREE SPRINKLER VK4700 (K3.0) TECHNICAL DATA

TECHNICAL DATA OBSOLETE

freedom residential horizontal sidewall lead free sprinkler VK4840 (k4.2)

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

MIRAGE STANDARD AND QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463 (K5.6) TECHNICAL DATA

QUICK RESPONSE EXTENDED COVERAGE FUSIBLE ELEMENT PENDENT SPRINKLER VK601 (K5.6) TECHNICAL DATA

TECHNICAL DATA. Page 1 of 5

TECHNICAL DATA. Cover Plate Assembly must be ordered separately:

FREEDOM RESIDENTIAL PENDENT SPRINKLER VK470 (K3.0) TECHNICAL DATA

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for C-UL-US-EU Listing requirements that must be followed.

TECHNICAL DATA vk470 (K3.0)

MicrofastHP EC/QREC FUSIBLE ELEMENT HSW HIGH PRESSURE SPRINKLER VK613 (K5.6) TECHNICAL DATA

ec/qrec ordinary hazard upright and pendent sprinklers vk570 and vk572 (k14.0)

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT UPRIGHT SPRINKLER VK535 (K11.2) TECHNICAL DATA

qr fusible element sprinklers (part nos , 13959, 17535, and 17536) 3. technical data Sprinkler 42h March 14, 2013

standard/quick response extended coverage light and ordinary hazard elo sprinklers

standard response fusible link sidewall sprinkler VK112 (K5.6)

TECHNICAL DATA. Refer to Approval Chart 1 and FM Design Criteria for FM Approval requirements that must be followed.

QUICK RESPONSE FUSIBLE ELEMENT HSW SPRINKLERS VK308 AND HP VK320 (PART NOS AND 13955) TECHNICAL DATA

EC/QREC ORDINARY HAZARD PENDENT SPRINKLER VK572 (K14.0) TECHNICAL DATA

standard response/ quick response extended coverage

standard response Fusible Link Upright sprinkler VK204 (K8.0)

STANDARD/QUICK RESPONSE ECOH ELO FUSIBLE ELEMENT PENDENT SPRINKLER VK537 (K11.2) TECHNICAL DATA

MicrofastHP EC/QREC FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK611 (K5.6) TECHNICAL DATA

TECHNICAL DATA 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA

Special Features: For Light Hazard Occupancies Only Designed for Corridor Applications 28 Maximum Width Spacing. 3. technical data

TECHNICAL DATA. Refer to Approval Chart 1 and UL Design Criteria for culus Listing requirements that must be followed.

microfast and microfasthp quick response horizontal sidewall sprinklers (vk305 & vk319)

quick response Sprinkler 105a October 25, 2010

TECHNICAL DATA. MicrofastHP QUICK RESPONSE FUSIBLE ELEMENT PENDENT HIGH PRESSURE SPRINKLER VK318 (K5.6)

standard response dry horizontal sidewall sprinklers

microfast sr/qr extended coverage pendent sprinkler

STANDARD/QUICK RESPONSE EXTENDED COVERAGE DRY HORIZONTAL SIDEWALL SPRINKLER TECHNICAL DATA

quick response extended coverage horizontal sidewall sprinkler vk630 (k8.0)

Microfast quick response Fusible element hsw sprinkler

QUICK RESPONSE EXTENDED COVERAGE HORIZONTAL SIDEWALL SPRINKLER VK630 (K8.0) TECHNICAL DATA

STANDARD/QUICK RESPONSE EXTENDED COVERAGE PENDENT SPRINKLER VK602 TECHNICAL DATA

TECHNICAL DATA. Page 1 of 6

quick response horizontal sidewall sprinkler vk360 (K8.0)

microfast quick response extended coverage hsw sprinkler vk606

standard response elo upright and pendent sprinklers (storage-density/area)

STANDARD RESPONSE FUSIBLE LINK PENDENT SPRINKLER VK008 (K4.2) TECHNICAL DATA 1. DESCRIPTION 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA.

microfast and microfasthp quick conventional sprinklers

micromatic standard response stainless steel sprinklers

EC/QREC ORDINARY HAZARD UPRIGHT SPRINKLER VK570 (K14.0) TECHNICAL DATA

TECHNICAL DATA. Refer to Approval Chart 1 and Design Criteria for culus Listing requirements that must be followed.

MICROFAST AND MicrofastHP QUICK RESPONSE PENDENT SPRINKLERS TECHNICAL DATA

standard response large orifice dry

TECHNICAL DATA. 2. LISTINGS AND APPROVALS culus Listed: Category VNIV FM Approved: Class 2009 NYC Approved: MEA E, Volume 3

STANDARD RESPONSE DRY HORIZONTAL SIDEWALL SPRINKLERS TECHNICAL DATA

Transcription:

March 2, 2007 Sprinkler 147k 1. DESCRIPTION Viking Freedom Residential Concealed Pendent Sprinkler VK425 is small a highsensitivity solder link and lever residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler has a K-Factor of 4.1 (59.1 metric*). The fast response operating element and special deflector combine speed of operation and areas of coverage to meet residential sprinkler standards. The two-piece design of the unit allows installation and testing of the sprinkler prior to installation of the cover plate. After the system has been tested and the ceiling finish applied, the push-on, thread-off design of the cover plate assemblies allows easy installation of the cover plates with up to ½ (12.7 mm) adjustment available. This feature also permits temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. 2. LISTINGS AND APPROVALS culus Listed: Category VKKW NYC Approved: MEA 89-92-E, Volume 24 NSF Certified: NSF/ANSI Standard 61, Drinking Water System Components Refer to the Approval Chart on page 147m and Design Criteria on page 147n for culus Listing requirements that must be followed. 3. Specifications: Minimum Operating Pressure: 7 psi (0.5 bar). Maximum Working Pressure: 175 psi (12 bar). Factory tested pneumatically to 95 psi (6.55 bar). Spring: U.S.A. Patent No. 4,570,720 Thread size: 1/2 (15 mm) NPT Nominal K-Factor: 4.1 U.S. (59.1 metric ) Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. Overall Length (Sprinkler Body): 2-3/16 (56 mm) Viking Technical Data may be found on The Viking Corporation s Web site at http://www.vikinggroupinc.com. The Web site may include a more recent edition of this Technical Data Page. Material Standards: Sprinkler Body: Brass UNS-C84400 Body Cap: Brass UNS-C26000 Deflector: Copper UNS-C19500 Deflector Pins: Stainless Steel UNS-S30300 Button: Brass UNS-C31400 Compression Screw: Brass UNS-C36000 Fusible Link Assembly: Beryllium Nickel Fusible Link Levers: Stainless Steel UNS-S31600 Lever Bar: Copper Alloy UNS-C72500 Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Cover Plate Materials: Cover Plate Assembly: Brass UNS-C26000 or UNS-C26800 Spring: Beryllium Nickel Solder: Eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Freedom Residential Concealed Pendent Sprinkler VK425 and Cover Plate Assembly must be ordered separately: Sprinkler: Part No. 10784AJ (includes a 140 F (60 C) rated sprinkler). Cover Plate Assembly: Base Part No. 10786 Form No. F_080399 Replaces page 147a-c, dated May 13, 2005 (added info. regarding custom colors.)

Sprinkler 147l March 2, 2007 Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature rating to the base part number: Finish Suffix: Polished Chrome = F, Brushed Chrome = F-/B, Bright Brass = B, Antique Brass = B-/A, Brushed Brass = B-/B, Brushed Copper = E-/B, Painted White = M-/SW1004, Painted Ivory = M-/SW1634, Painted Black = M-/SW1007 Temperature Suffix ( F/ C): 135 /57 = A For example, cover 10786 with a Polished Chrome finish and a 135 F/57 C temperature rating = 10786FA. Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the Sprinkler Accessories section of the Viking data book.) Sprinkler Wrenches**: A. Heavy Duty Wrench Part Number 08336W/B (available since 1993), or B. Head Cabinet Wrench Part Number 10366W/B** (available since 1998) *Requires a ½ ratchet (not available from Viking). **Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A, Capacity: six (6) sprinklers (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the fusible link to disengage, releasing the deflector and sealing assembly. Water flowing through the sprinkler orifice strikes the deflector, forming a uniform spray pattern over a specific area of coverage determined by the water supply pressure at the sprinkler to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler SIN VK425 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking s current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating 1 Maximum Ambient Ceiling Temperature 2 Temperature Rating of the Cover Assembly (Required) Cover Plate Base Part Number 3 Ordinary 140 F (60 C) 100 F (38 C) 135 F (57 C) 10786 Cover Plate Finishes: Bright Brass, Brushed Brass, Antique Brass, Polished Chrome, Brushed Chrome, Brushed Copper, Painted White, Painted Ivory, and Painted Black Footnotes 1 The sprinkler temperature rating is stamped on the sprinkler. 2 Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule.

March 2, 2007 Sprinkler 147m Sprinkler Base Part Number 1 SIN Approval Chart Residential Concealed Pendent Sprinkler SIN VK425 For systems designed to NFPA 13D or NFPA 13R. Overall Length NPT Thread Size Nominal K-Factor Maximum Water (Sprinkler Body) Working Pressure Inches mm U.S. metric 2 Inches mm 10784A VK425 1/2 15 4.1 59.1 175 psi (12 bar) 2-3/16 56 Maximum Areas of Coverage 7 Minimum Water Supply Requirements 7 (Refer also to Design Criteria on page 147n.) Listings and Approvals 3 culus 4 NYC 5 FM NSF 6 Installed below smooth, flat, horizontal ceilings, including ceilings with slopes up to and including 2/12 (9.5 ). 12 ft. x 12 ft. (3.7 m x 3.7 m) 15 gpm @ 13.4 psi (56.8 L/min @ 0.92 bar) AX1 AX1 -- AX1 14 ft. x 14 ft. (4.3 m x 4.3 m) 16 gpm @ 15.2psi (60.6 L/min @ 1.05 bar) AX1 AX1 -- AX1 16 ft. x 16 ft. (4.9 m x 4.9 m) 20 gpm @ 23.8 psi (75.7 L/min @ 1.64 bar) AX1 AX1 -- AX1 Sprinkler Temperature Ratings A - 140 F (60 C) Cover Temperature Rating X - 135 F (57 C) Cover Plate Finishes 1 - Bright Brass, Brushed Brass, Antique Brass, Polished Chrome, Brushed Chrome, Brushed Copper, Painted White, Painted Ivory, and Painted Black 8 Footnotes 1 Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kpa, divide the metric K-factor shown by 10.0. 3 This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. 4 Listed by Underwriter s Laboratories for use in the U.S. and Canada. 5 Accepted for use, City of New York Department of Buildings, MEA Number 89-92-E, Vol. 24. 6 Tested and Certified by NSF to NSF/ANSI Standard 61, Drinking Water System Components. 7 For areas of coverage smaller than shown, use the Minimum Water Supply Requirement for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum Water Supply Requirement used. 8 Other paint colors are available on request with the same listings as the standard finish colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 4.

Sprinkler 147n March 2, 2007 culus Listing Requirements: DESIGN CRITERIA (Also refer to the Approval Chart on page 147m.) When using Viking Residential Sprinkler SIN VK425 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of coverage and minimum water supply requirements shown in the Approval Chart on page 147m. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: The flow rates given in the Approval Chart on data page 147m for NFPA 13D and NFPA 13R applications for each listed area of coverage, or A minimum discharge of 0.1 gpm/ft 2 (4.07 mm/min) over the design area consisting of the four contiguous most hydraulically demanding sprinklers for the coverage areas being protected by the four sprinklers. NOTE: The A S = S x L method must be used to determine the sprinkler protection area of coverage per NFPA 13. Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to pages RES1-17 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Figure 2: Concealed Sprinkler and Cover Assembly Figure 1: Sprinkler Installation and Correct Use of Wrenches

March 2, 2007 Sprinkler 147o Figure 3: Sprinkler Dimensions and Cover Installation Figure 4: Identification of Custom Paint Color for Concealed Covers

THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_080399 Replaces page 147a-c, dated May 13, 2005 (added info. regarding custom colors.)