* _rev1* User guide DRIVER 230 CPL. 3 zone weekly programmer using power line carriers

Similar documents
RADIO DRIVER. * _Rev.1* User guide. Wireless programmer. RADIO DRIVER zone RADIO DRIVER zones RADIO DRIVER zones

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

MINOR 11. * _rev.1* Installation and User Guide. Electronic thermostat for underfloor heating or radiant ceiling heating

Screens and Controls p.64. Wireless alarm system p.52 Bus alarm system p.58. Controls p.69. Interface p.68. Telephone remote controls p.

Programmable Towel Radiator Manual

HOME AUTOMATION WIRELESS. making your life EASIER

STARBOX F02 Energy Manager

Heating and THE CONNECTED HOME

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

Security System. User Guide for the LED Command Center

RF Programmable Room Thermostat User Instructions

Wireless Keypad GKP-S8M

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

Instruction manual. Remote control electric IR HEATER

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

AXI LED USER MANUAL (REV. 1.0)

Installation and user manual

REMOTE CONTROL UNIT. Ignition Open the gas supply tap. Press the switch (5) of the gas valve in I position.

Vokèra OpenTherm 711 without external sensor connected

Vokèra OpenTherm 711 with external sensor connected

Wireless Keypads LKP(E)S8M Series

User Guide for EHE & EHE Programmable Room Thermostat

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

Contents. Glossary

3 User s settings. 3.3 Internal clock setting

JA-63 Profi User manual

1. Introduction. 2. Product overview

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

USER GUIDE. Security Control Panels INS046-7

MEGA WAY LCD 4-CHANNEL MOTORCYCLE ALARM SECURITY SYSTEM. Operation Manual MEGATRONIX CALIFORNIA, U.S.A. MEGA 3100 OPERATE 1

Self-learning Room Temperature Controller

Total Connect Box. User manual

ABORT Light flashes during an abort delay time; is on during or after an alarm report to the central station. EMERGENCY ACTIVATION KEYS

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

L900 series USER MANUAL

Owner s Manual. Part Number 33CS250-RC

REA22 Room Temperature Controller

INDUSTRY Catalogue. Designing and manufacturing your solutions

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

Watts Under Floor Multi-zone Controller User Manual

User Manual THR870CUK Programmable Thermostat

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

User Manual THR872CUK Wireless Programmable Thermostat

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

OWNER S MANUAL. Part Number P RF

Self-learning Room Temperature Controller

CSP-204 CSP-208 CSP-104 CSP-108

THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels

Eswa DC-1. Thermostat for Floor Heating

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

Ref.1067/032 Ref.1067/042

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

Edited by Foxit PDF Editor Copyright (c) by Foxit Software Comp. Programmable digital room thermostat. NEW software! Operating Instructions

SA 2650 Kit User Manual

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

CARETAKER PLUS: MOST FREQUESNTLY ASKED QUESTIONS. Which sensor programming group should I use for a wireless freeze sensor?

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

Digital Electronic Thermostat With RF

Version 1.03 January-2002 USER S MANUAL

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

NetworX NX-8V2. LED Keypad User Manual

CS027 User Instructions

Safety & Installation Instructions

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

Volvo On Call. Owners Manual

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

installation & operation manual

Easy-Stat. Wireless Programmable Room Thermostat Pt No

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

Galaxy Flex V3. User Guide. Honeywell Security. This user manual is located at

CentaurPlus C21 Series 2 User Operating Instructions

C-Stat 17-ZW User Instructions

Installation & User s Instructions

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

Installation, Programming and Operating Guide for Digital, Programmable Thermostat with Smart Fan Technology. with SFT (Smart Fan Technology )

ETN-24-HC21-PROG Econo-Vent

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

CentaurStat 7 User Operating Instructions Central Heating Programmable Room ThermoStat

CentaurPlus C27 Series 2 User Operating Instructions

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

DESCRIPTION OF KEYPAD (Access module with segments)

Set & $ave. Model Programmable Thermostat. installation and operation manual

Safety / Kit Components 1

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

NetworX Series NX-1500E LED Keypad

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

Summit 3208GLD USER MANUAL. Electronics Line

RC-101 Heat Pump Real Time Pricing System 2 Stage Heat / 1 Stage Cool

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation

OPERATING INSTRUCTIONS

Programmable Electronic Thermostat

Digital Electronic Thermostat With RF

Transcription:

User guide DRIVER 230 CPL 3 zone weekly programmer using power line carriers DELTA DORE - Bonnemain 35270 COMBOURG - FRANCE E-mail : deltadore@deltadore.com Device complying with the requirements of the directives: 2004/108/EEC (electromagnetic compatibility) and 2006/95/EEC (low voltage safety). *2702030_rev1*

Contents Description......................... 3 Time Setting......................... 5 The Pilot Wire....................... 5 Comfort, Economy, Frost Protection........ 6 Automatic mode...................... 6 Change the programming................ 7 Comfort or Economy Override............ 8 Shutdown mode...................... 8 Adjustable frost protection.............. 9 Remote controlled absence mode.........10 Domotic functions (if radio option) with a door/window magnetic contact... 11 with a TYXIA Transmitter... 11 with a TYDOM 200 remote control... 12 with a TYDOM 300 telephone transmitter... 13 with a TYXAL alarm control unit... 13-14 Because of changes in standards and equipment, the characteristics given in the text and the illustrations of this document are not binding unless confirmed by Delta Dore. Description 1 2 3 Time 2 Current day 3 Tariff reduction in progress 4 Current mode: Comfort 5 8 Automatic mode Comfort Economy Modification or override buttons 6 Timed absence button or validation in programming mode 7 Knob selection mark 8 Identification of the heating zone 4 5 6 7 Economy Frost Protection Shutdown Programming Starting up - 3 -

Description Heating Programming - 1 customizable program per day and per zone - Automatic mode override: It is possible to use a different operating mode (Comfort, Economy, etc.) from the current one, until the next change of program - Absence: Constant or timed (from 1 to 99 days) to set the installation to frost protection mode Transmission by power line carrier - No damage to the existing installation - Use with pilot wire receivers of the X2D PLC range - Compatible with an energy manager (e.g. GECPL1, GP4 CPL) - Upgradeable system Tariff Management - Linked with a CPL X2D energy manager (e.g. GECPL1 or GP4 CPL), it can reduce your energy consumption according to the current tariff period - Compatibility with all tariffs Radio Option - DRIVER CPL is compatible with the TYDOM 520 radio module that is used to associate domotics functions: door/window magnetic contact, alarm control unit, etc. Time Setting Turn the selector to The Pilot Wire Press and release: slow forward. Press and hold: fast forward. Each time you pass 0.00 you change the day The pilot wire principle enables the required operating mode for the heating element to be selected from the programming control unit. The corresponding temperature is set directly by the heating element thermostat (room by room control). Command sent by the control unit Comfort Economy Frost Protection Shutdown or Corresponding temperature on the heating element Comfort setting (thermostat knob) Economy setting or -2 C or -3 C in relation to the comfort setting (according to the model) Frost protection set to 7 C or 8 C (depending on model) Heating shutdown - 4 - - 5 -

Comfort, Economy or Continuous Frost Protection Change the programming Permanent comfort Turn the selector to Continuous Economy mode Turn the selector to Turn the selector to PROG. The 1st time slot flashes on and off. The programming uses slots of one hour. Press the buttons + (comfort) or - (economy) to set each time slot. E.g. Comfort from 6.00 am to 9.00 am from 12am to 2pm, from 6pm to 11pm. Comfort for 1 hour Economy for 1 hour Continuous Frost Protection Turn the selector to Confirm and go to the next day. Repeat for each day. Automatic Mode Holding down the OK button lets you allocate the same program as the previously programmed day to the following day. Turn the selector to AUTO A U T O To modify the program of zones 2 or 3, turn the knob to PROG or PROG and repeat the steps above. The unit follows the program for the three zones. Change the position selector to exit the mode. - 6 - - 7 -

Override with automatic return (comfort or economy mode) Adjustable frost protection (1 to 99 days) - Absence mode The selector is set to AUTO The unit follows the program (e.g. comfort in zone 1 and economy in zone 2 and 3) Press. On zone 1, the unit operates in Economy mode until the next program change. For a zone 2 or 3 override, press or. From the AUTO mode. Press for approximately 3 seconds until the suitcase symbol displays (continuous absence). Set the number of days of absence with the + or - buttons, the suitcase symbol flashes. The countdown begins. Note: If you are using 6-order pilot wire, override takes place amongst 4 modes: Comfort Comfort -2 C Example: leaving on 10 January, returning on 19 January, indicate 9 days. Automatic operation will resume on 19 January at 0:00 a.m. Economy Comfort -1 C Heating shutdown Turn the selector to - 8 - - 9 -

Remote controlled absence mode (Frost Protection) DRIVER 230 CPL can be associated with a power line carrier telephone remote control (e.g. TYPHONE 2 CPL) or a GECPL1 whose telephone remote control input is connected to a TYPHONE 2 to enable remote selection between the absence mode and automatic operation. - TYPHONE 2 + GECPL1 : Setting the absence mode Before leaving the dwelling, confirm your absence on the telephone remote control. "tele" is displayed. ➀ Return to normal operation Order the termination of absence mode either remotely or locally (on the telephone remote control). The operation reverts to the one shown by the knob position. - TYPHONE 2 CPL: Setting the absence mode Remotely, send the absence command. The screen of the DRIVER CPL displays the suitcase and telephone symbols. ➀ Return to normal operation Remotely: stop the absence order. Locally: change the knob position, then return it to the required position. Domotic functions With the TYDOM 520 radio option, up to 16 domotics products can be associated (door/window magnetic contacts, telephone transmitter, alarm control unit, remote controls, etc.) using the DRIVER CPL. Operation with a door/window magnetic contact You can combine up to 16 door/window magnetic contacts (maximum number of domotics products that can be combined). If one of them is opened, DRIVER CPL sets the installation to Frost Protection mode. Operation with a TYXIA Transmitter For this type of operation, the DRIVER CPL must be in automatic mode. Pressing the button enables a comfort override with automatic return at the next change of program. Pressing the button enables an economy override with automatic return at the next change of program. The override can be cancelled by pressing a button or turning the selector of the DRIVER CPL. - 12 - - 13 -

Domotic functions Operation with a Tydom 200 remote control From the home domain : You can shut down the installation by pressing the tactile button. This shutdown command is cancelled: - either by pressing the button, - or by changing the position of the DRIVER CPL selector. In the AUTO position of the DRIVER CPL only: Pressing the tactile button or once enables an override operation The override is cancelled: By zone: - the next time the program switches over in the zone, - by pressing the, or button of the DRIVER CPL. On the 3 zones: - by changing the position of the DRIVER CPL selector. - by pressing the, or button of the TYDOM 200. - 1 - OR Operation with a TYDOM 300 telephone transmitter By calling the TYDOM 300 telephone transmitter, let the synthetic voice guide you to determine or modify the status of the heating system (see the TYDOM 300 transmitter guide). If a change is made via the TYDOM 300 telephone transmitter, the DRIVER CPL displays the telephone symbol and the mode controlled (e.g. comfort). Change the position of the DRIVER CPL to return to normal operation. Operation with a TYXAL alarm control unit The DRIVER CPL receives and displays the technical fault information of the TYXAL alarm control unit. If a fault occurs, the display flashes alternately with the current program for 2 minutes and indicates: 1. Intruder or technical alarm 2. Tamper alarm 3. Battery 4. Supervision 5. Open entry 6. Mains fault in progress 7. Technical fault in progress - 1 -

Domotic functions Override according to the alarm status In the AUTO position only and if the function (1) is activated: - Starting up the control unit fully sets the installation to Economy mode in the 3 zones (up to the next change of program). - Shutting down the control unit sets the installation to Comfort mode in the 3 zones (up to the next change of program). The override is cancelled: By zone: - the next time the program switches over in the zone, - by pressing the, or button of the DRIVER CPL. On the 3 zones: - by changing the position of the DRIVER CPL selector. (1) The override function is enabled by default depending on the status of the alarm, it can be deactivated during the radio configuration: From the radio screen, press the buttons and together to display ON or OFF. Release. Press or to select ON or OFF. OR After 2 seconds without pressing, the screen of the DRIVER CPL returns to the radio display, press the DRIVER CPL button until the time displays. - 14 - Maintenance Nothing is displayed on the room unit screen. The symbol is displayed. You cannot access the Comfort. -1 C and Comfort -2 C operating modes. The equipment displays: The equipment displays: The equipment displays: Diagnosis/Solutions You have just switched the unit on. You have just switched the unit on. There is no power supply Check your circuit breaker. An economy period interrupts automatic operation. The reduced tariff operating mode can be modified ( Price Programming). Overrides are permitted. You have 4 order pilot wire heating or it has been defined as such (see installation guide Allocation of receivers). Communication fault with the GECPL1 or GPCPL. Check the power supply of the GECPL1 or GP4 CPL or reconfigure your units. Communication fault with electronic meter. Check the connection between the electronic meter and the energy manager or contact your installer. Communication fault with the TYPHONE 2 CPL. Check the power supply of the TYPHONE 2 CPL or reconfigure your units (see installation guide, Allocation of receivers). - 15 -