User guide DRIVER 230 CPL 3 zone weekly programmer using power line carriers DELTA DORE - Bonnemain 35270 COMBOURG - FRANCE E-mail : deltadore@deltadore.com Device complying with the requirements of the directives: 2004/108/EEC (electromagnetic compatibility) and 2006/95/EEC (low voltage safety). *2702030_rev1*
Contents Description......................... 3 Time Setting......................... 5 The Pilot Wire....................... 5 Comfort, Economy, Frost Protection........ 6 Automatic mode...................... 6 Change the programming................ 7 Comfort or Economy Override............ 8 Shutdown mode...................... 8 Adjustable frost protection.............. 9 Remote controlled absence mode.........10 Domotic functions (if radio option) with a door/window magnetic contact... 11 with a TYXIA Transmitter... 11 with a TYDOM 200 remote control... 12 with a TYDOM 300 telephone transmitter... 13 with a TYXAL alarm control unit... 13-14 Because of changes in standards and equipment, the characteristics given in the text and the illustrations of this document are not binding unless confirmed by Delta Dore. Description 1 2 3 Time 2 Current day 3 Tariff reduction in progress 4 Current mode: Comfort 5 8 Automatic mode Comfort Economy Modification or override buttons 6 Timed absence button or validation in programming mode 7 Knob selection mark 8 Identification of the heating zone 4 5 6 7 Economy Frost Protection Shutdown Programming Starting up - 3 -
Description Heating Programming - 1 customizable program per day and per zone - Automatic mode override: It is possible to use a different operating mode (Comfort, Economy, etc.) from the current one, until the next change of program - Absence: Constant or timed (from 1 to 99 days) to set the installation to frost protection mode Transmission by power line carrier - No damage to the existing installation - Use with pilot wire receivers of the X2D PLC range - Compatible with an energy manager (e.g. GECPL1, GP4 CPL) - Upgradeable system Tariff Management - Linked with a CPL X2D energy manager (e.g. GECPL1 or GP4 CPL), it can reduce your energy consumption according to the current tariff period - Compatibility with all tariffs Radio Option - DRIVER CPL is compatible with the TYDOM 520 radio module that is used to associate domotics functions: door/window magnetic contact, alarm control unit, etc. Time Setting Turn the selector to The Pilot Wire Press and release: slow forward. Press and hold: fast forward. Each time you pass 0.00 you change the day The pilot wire principle enables the required operating mode for the heating element to be selected from the programming control unit. The corresponding temperature is set directly by the heating element thermostat (room by room control). Command sent by the control unit Comfort Economy Frost Protection Shutdown or Corresponding temperature on the heating element Comfort setting (thermostat knob) Economy setting or -2 C or -3 C in relation to the comfort setting (according to the model) Frost protection set to 7 C or 8 C (depending on model) Heating shutdown - 4 - - 5 -
Comfort, Economy or Continuous Frost Protection Change the programming Permanent comfort Turn the selector to Continuous Economy mode Turn the selector to Turn the selector to PROG. The 1st time slot flashes on and off. The programming uses slots of one hour. Press the buttons + (comfort) or - (economy) to set each time slot. E.g. Comfort from 6.00 am to 9.00 am from 12am to 2pm, from 6pm to 11pm. Comfort for 1 hour Economy for 1 hour Continuous Frost Protection Turn the selector to Confirm and go to the next day. Repeat for each day. Automatic Mode Holding down the OK button lets you allocate the same program as the previously programmed day to the following day. Turn the selector to AUTO A U T O To modify the program of zones 2 or 3, turn the knob to PROG or PROG and repeat the steps above. The unit follows the program for the three zones. Change the position selector to exit the mode. - 6 - - 7 -
Override with automatic return (comfort or economy mode) Adjustable frost protection (1 to 99 days) - Absence mode The selector is set to AUTO The unit follows the program (e.g. comfort in zone 1 and economy in zone 2 and 3) Press. On zone 1, the unit operates in Economy mode until the next program change. For a zone 2 or 3 override, press or. From the AUTO mode. Press for approximately 3 seconds until the suitcase symbol displays (continuous absence). Set the number of days of absence with the + or - buttons, the suitcase symbol flashes. The countdown begins. Note: If you are using 6-order pilot wire, override takes place amongst 4 modes: Comfort Comfort -2 C Example: leaving on 10 January, returning on 19 January, indicate 9 days. Automatic operation will resume on 19 January at 0:00 a.m. Economy Comfort -1 C Heating shutdown Turn the selector to - 8 - - 9 -
Remote controlled absence mode (Frost Protection) DRIVER 230 CPL can be associated with a power line carrier telephone remote control (e.g. TYPHONE 2 CPL) or a GECPL1 whose telephone remote control input is connected to a TYPHONE 2 to enable remote selection between the absence mode and automatic operation. - TYPHONE 2 + GECPL1 : Setting the absence mode Before leaving the dwelling, confirm your absence on the telephone remote control. "tele" is displayed. ➀ Return to normal operation Order the termination of absence mode either remotely or locally (on the telephone remote control). The operation reverts to the one shown by the knob position. - TYPHONE 2 CPL: Setting the absence mode Remotely, send the absence command. The screen of the DRIVER CPL displays the suitcase and telephone symbols. ➀ Return to normal operation Remotely: stop the absence order. Locally: change the knob position, then return it to the required position. Domotic functions With the TYDOM 520 radio option, up to 16 domotics products can be associated (door/window magnetic contacts, telephone transmitter, alarm control unit, remote controls, etc.) using the DRIVER CPL. Operation with a door/window magnetic contact You can combine up to 16 door/window magnetic contacts (maximum number of domotics products that can be combined). If one of them is opened, DRIVER CPL sets the installation to Frost Protection mode. Operation with a TYXIA Transmitter For this type of operation, the DRIVER CPL must be in automatic mode. Pressing the button enables a comfort override with automatic return at the next change of program. Pressing the button enables an economy override with automatic return at the next change of program. The override can be cancelled by pressing a button or turning the selector of the DRIVER CPL. - 12 - - 13 -
Domotic functions Operation with a Tydom 200 remote control From the home domain : You can shut down the installation by pressing the tactile button. This shutdown command is cancelled: - either by pressing the button, - or by changing the position of the DRIVER CPL selector. In the AUTO position of the DRIVER CPL only: Pressing the tactile button or once enables an override operation The override is cancelled: By zone: - the next time the program switches over in the zone, - by pressing the, or button of the DRIVER CPL. On the 3 zones: - by changing the position of the DRIVER CPL selector. - by pressing the, or button of the TYDOM 200. - 1 - OR Operation with a TYDOM 300 telephone transmitter By calling the TYDOM 300 telephone transmitter, let the synthetic voice guide you to determine or modify the status of the heating system (see the TYDOM 300 transmitter guide). If a change is made via the TYDOM 300 telephone transmitter, the DRIVER CPL displays the telephone symbol and the mode controlled (e.g. comfort). Change the position of the DRIVER CPL to return to normal operation. Operation with a TYXAL alarm control unit The DRIVER CPL receives and displays the technical fault information of the TYXAL alarm control unit. If a fault occurs, the display flashes alternately with the current program for 2 minutes and indicates: 1. Intruder or technical alarm 2. Tamper alarm 3. Battery 4. Supervision 5. Open entry 6. Mains fault in progress 7. Technical fault in progress - 1 -
Domotic functions Override according to the alarm status In the AUTO position only and if the function (1) is activated: - Starting up the control unit fully sets the installation to Economy mode in the 3 zones (up to the next change of program). - Shutting down the control unit sets the installation to Comfort mode in the 3 zones (up to the next change of program). The override is cancelled: By zone: - the next time the program switches over in the zone, - by pressing the, or button of the DRIVER CPL. On the 3 zones: - by changing the position of the DRIVER CPL selector. (1) The override function is enabled by default depending on the status of the alarm, it can be deactivated during the radio configuration: From the radio screen, press the buttons and together to display ON or OFF. Release. Press or to select ON or OFF. OR After 2 seconds without pressing, the screen of the DRIVER CPL returns to the radio display, press the DRIVER CPL button until the time displays. - 14 - Maintenance Nothing is displayed on the room unit screen. The symbol is displayed. You cannot access the Comfort. -1 C and Comfort -2 C operating modes. The equipment displays: The equipment displays: The equipment displays: Diagnosis/Solutions You have just switched the unit on. You have just switched the unit on. There is no power supply Check your circuit breaker. An economy period interrupts automatic operation. The reduced tariff operating mode can be modified ( Price Programming). Overrides are permitted. You have 4 order pilot wire heating or it has been defined as such (see installation guide Allocation of receivers). Communication fault with the GECPL1 or GPCPL. Check the power supply of the GECPL1 or GP4 CPL or reconfigure your units. Communication fault with electronic meter. Check the connection between the electronic meter and the energy manager or contact your installer. Communication fault with the TYPHONE 2 CPL. Check the power supply of the TYPHONE 2 CPL or reconfigure your units (see installation guide, Allocation of receivers). - 15 -