Corrosion Resistant Fluid and Air Handling Systems.

Similar documents
TrueClean ToteCleaner

ELECTRONIC FAUCETS INSTRUCTION MANUAL. Toll Free: (800) Haul Road Wayne, NJ krowne.

TrueClean ToteCleaner

INSTRUCTION MANUAL HS-229G

Air Pump Up to 800 gallons

Ion Genesis II Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Ion Endeavor Pump Controller Digital Level Control with Pump Alternation and High Water Alarm

Design Criteria. Installation

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

ion Genesis Pump Controller

Gas Connector Installation Instructions

SERVICE MANUAL (v1) UL / ULC. WET CHEMICAL HAND PORTABLE RESTAURANT KITCHEN FIRE EXTINGUISHERS Model: SF-6LK / WBDL-6LK

CD6102 / CD6102 OC / CD6102-2

Installation Manual Universal Single-Arm Side-of-Pole Mount UNI-SA/21.5

MaxLite LED MICRO-T PANEL

Please read and follow all instructions for usage and maintenance before operating the VACMASTER SV1 Immersion Circulator.

Retro-DWS Internal Heating Cable System for Non-Pressurized Sewer and Waste Drain Pipes

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

MN908 No. 282C Replaces 282B LB7013

WARNING. Pro Pack Portable Spray Pack 3A1292C. Operation. Model 24F893 Maximum Working Pressure 12 psi (0.83 bar, MPa)

Pressurized Filter Up to 1250 gallons

- User Brochure tekmarnet 4 Setpoint Control 161

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

TORRID MARINE YACHT QUALITY Since Owner s Manual

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

XC Portable Air Conditioning

User Manual. Hot Water Dispenser. Models: 177HWD15G 12/2018. Please read and keep these instructions. Indoor use only.

Industrial Vacuums, Inc

Installation & Operation Manual

User s Manual and Warranty Information for Counterweighted Chain Drive ThyssenKrupp Access

INSTALLATION INSTRUCTIONS for PULSAR NS-Series Nav/Position or Nav/Position/Strobe Lights

C L E A N I N G / M A I N T E N A N C E WA R R A N T Y I N F O R M AT I O N CLEANING/MAINTENANCE FAN STORAGE 3 YEAR LIMITED WARRANTY INSTRUCTIONS

SH-2000, SH-2500, AB-3000 Bimetallic Steam Traps Installation and Operation Manual SH-2000

IMPORTANT INFORMATION - PLEASE READ CAREFULLY

OPERATION MANUAL Dated: 04/09/2018 Document Name: SHV _OM Page 1 of 8. Ion Technologies SHV40, 75 & 100 Sewage Ejector Pump SAFETY WARNINGS

To get started, please read and follow all instructions for usage and maintenance carefully before operating the VACMASTER BS116 Impulse Bag Sealer.

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Flat Line Spray Systems Kits

EQUIPMENT Operation Manual

Heater Installation Kit

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

OPERATING MANUAL Gfp 255C Please read this manual carefully before operating!

IMPORTANT SAFETY INSTRUCTIONS EC-AG1-25 EC-AG1, EC-AG2 SAVE THESE INSTRUCTIONS.

Electric Radiator. A cost effective approach to save fuel and reduce noise for generators from 2 to 10 kw

INDUSTRIAL - AQUEOUS PARTS CLEANER EM5 5 GALLON BENCH TOP

TL-105 COLUMN HEATER

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Models: SV1 (110V) SV1EU ( V) User s Manual. Register your product and get support at. v

DH07, DH07A /DH08, DH08A CONVECTED AIR DISH HEATERS

6 Sheet Strip-Cut Shredder for Home/Office

Model CV-1FR Riser Check Valves 2 to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data. Page 1 of 6 OCTOBER 2010 TFP950

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

MaxLite 4, 6, 8 & 9 LED Architectural & Commercial Downlights

H-16.5 Record Cleaning Machine Setup and Instruction Manual

Installation Instructions PP-AS20 Anti-Scale System

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

LABORATORY ILLUMINATED FLOTATION BATH

SKORPION Process Air Heater

Torq N Seal. Operating and Maintenance Instructions. Mechanical Tube Plugs

Drain Tempering Reservoir READ & SAVE THESE INSTRUCTIONS. Installation, Operation, & Maintenance. TRION

TURBO Hooded Fans. Installation & Operator s Manual (14, 18, & 24 Direct Drive)

Installation & Maintenance Instructions

Installation and Operations Manual

OZONE SYSTEM FOR IN-GROUND POOLS New and Existing

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Installation Manual Universal Side-of-Pole Mount UNI-SP/01A

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

Model PT-05 Model PT-06

FLCH4R Garage and Utility Electric Heater

AeroVent 1 Product Manual

Read and save these instructions! DRANE-KOOLER. Water tempering device Installation, operation and maintenance manual

Model 8330 Stainless Steel Combination Shower Eye/Face Wash

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

Installation Manual Universal Top-of-Pole Mount UNI-TP/02

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

15 x15 Economy Swing Away Heat Press. (either domestic or foreign), please keep a copy of their sales invoice showing the serial

Model TWBS.EW.H Tempered Water Blending System

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference FREE FLOAT TYPE STEAM TRAPS SS3/SS5 SERIES. Manufacturer

AFA 500 FUME HOOD ALARMS

Honeywell Garrett Drop-in Intercooler for 2.3L Mustang EcoBoost IMPORTANT INFORMATION - PLEASE READ CAREFULLY

R A D I A N T O U T D O O R H E A T E R S OPERATION, INSTALLATION AND MAINTENANCE MANUAL. TT-MTM Wall Controller

MaxLite LED Vapor Tight Linear Fixture

FRESHAIR USER S MANUAL. CAUTION: Read manual carefully for proper procedures and operation.

Installation Manual Universal Side-of-Pole Mount UNI-SP/02A

Model /8300CRP-8309CRP Shower & Eye/Face Wash

User Manual. Conveyor Toaster. Models: T140 06/2017. Please read and keep these instructions. Indoor use only.

WatchDog NXT60. Installation and Operations Manual. Seaira Global, LLC NC Highway 50 Surf City, NC (910)

IAQ Series. Bosch IAQ Photo Catalytic Oxidizer (PCO) Residential Application. Installation Manual and Owner s Guide

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

- User Brochure Programmable Thermostat 510

Registrate by scanning. Add: North Carolina USA

PreView WorkSight. WS6220 WS6215 WS6210 Sensor Operating Manual.

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

SH-300, SH-900, SH-1500, SH-1600 and SH-1700 Bimetallic Steam Trap Installation and Operation Manual

NM A D E in MIC HIG A HL400 & HL800. Owner s Manual

Wax Base Heater & Dispenser

YOUR PORTABLE AIR PURIFIER

Cincinnati, OH USA

Model 7656WCC Eye/face Wash

Transcription:

Socket Fusion Hand Tool Operation & Maintenance Manual Corrosion Resistant Fluid and Air Handling Systems.

Description The Simtech portable socket fusion machines are available in two size ranges ½ -2 (20mm to 63mm) and ½ 4 (20mm to 110mm) in both IPS and metric sizes. Each unit come completes with an electric heating plate, digital temperature controller, durable plastic handle, two position metal bench mounting bracket and heater stand. The unit also includes a side handle handle attachment and heater bushing tools. A convenient carry case provides protection and safety while not in use. ½ -2 Tool is 110v / 800 w ½ -4 Tool is 110v / 1200 w 220v Avaliable upon request Safety Rules The use of electrical components is always a potential danger. In order to avoid any kind of accident caused by electrical sources it s strongly suggested to read and follow carefully the following safety rules before operating the machine. The working area must be clean. Do not use machine in rain, inclement weather or close to flammable liquids. Always use the machine in a fixed and safe position. The machine is operated by 110 Volts therefore be sure that the power supply plug is supplied with the safety devices according to the standard requirements also check that the power supply will be on the range of maximum 10% of the machine s nominal tension. Regularly check the cables and the plug. If the cable needs to be replaced, please contact factory. Never unplug the power supply by pulling the cable. Never carry the machine by the cable. Before using the machine, always check that the handle is dry. The heater is extremely hot, it s strongly suggested to use suitable gloves. Before packing away the machine, wait for the complete cooling of the heating surface. 2 SIMTECH

20mm through 63mm: Electrical requirements: 110/1Ph/60Hz.Unit includes: Metal carrying case, Table stand, Table clamp stand, Adjusting tools and fasteners. PTFE heater bushings 20mm, 25mm, 32mm, 40mm, 50mm, and 63mm sold separately 20mm through 110mm: Electrical requirements: 110/1Ph/60Hz.Unit includes: Metal carrying case, Table stand, Table clamp stand, Adjusting tools and fasteners. PTFE heater bushings 20mm, 25mm, 32mm, 40mm, 50mm, 63mm, 75mm, 90mm, and 110mm sold separately SIMTECH 3

Unpack the machine, put it in the support, and assemble the PTFE coated bushes of the required diameter. ( The diameter is clearly stamped on the bushes themselves) Make sure the Table vice is firmly mounted on the work bench and insert and secure the Hand Tool. Should supplied Cord length be insufficient, a standard 110V extension should be used. Select the right size bushing, corresponding to the size of the pipe and fitting to be welded. When facing the tool, position the female bushing on the right side of the tool and the male bushing on the left side. Line up the holes in the center of the bushing with the hole in the center of the heat plate. Put the allen bolt through the female bushing first then the heat plate and finally thread it into the male bushing. Use an allen wrench to ensure that both bushings are securely fastened to the heat plate. Plug the hand tool into a 110V socket; the green power light and the yellow temperature indicator light will go on. Select the appropriate temperature (260C) You can set the required temperature by pushing the up/down arrows. Wait until the yellow temperature indicator light goes off before proceeding with the weld. Pipe insertion depth must be marked from chamfered end as follow: Pipe OD Insert Depth 20mm / ½ 0.63 25mm / ¾ 0.7 32mm / 1 0.78 40mm 1¼ 0.86 50mm / 1½ 0.94 63mm / 2 1.14 Fitting and pipe should be pushed axially against the abutment (fitting) or the marking (pipe) and should be held there. The parts to be welded should be heated in accordance with the information and time given in the Socket Weld Reference Value chart. After the heating time, the fitting and pipes should be withdrawn from the heater element abruptly and without twisting. They should be pushed together right up to the mark or the abutment. After observing the Total Cooling Time your joint is now ready to take on full pressure (equal to the rating of the pipe and fitting). Clean the internal part of the fitting and the external part of the pipe with acetone or alcohol. ( Dirt or grease damage the weld) DO NOT USE ACETONE OR ANY OTHER CLEANING AGENTS ON THE BUSHINGS. Pipe must be cut square and the end must be chamfered. The fitting interior should be thoroughly cleaned using a cleaning agent. The pipe end should be chamfered on the outside. 4 SIMTECH

Standard values for socket welding of pipe and fittings at an ambient temperature of 20 C (70 F) and at a moderate air flow. Welding temperature for all methods: 255 C - 270 C (490 F - 520 F) PP Socket Welding Times DVS 2207-11 Pipe Insertion Time Maximum Change Over Time Cooling Time OD OD SDR11 Clamped Cooling Time (Inches) (MM) (sec) (sec) (sec) (min) 3/8 16 5 4 6 2 ½ 20 5 4 6 2 ¾ 25 7 4 10 2 1 32 8 6 10 4 1¼ 40 12 6 20 4 1½ 50 18 6 20 4 2 63 24 8 30 6 2½ 75 30 8 30 6 3 90 40 8 40 6 4 110 50 10 50 8 PVDF Socket Welding Times DVS 2207-15 Pipe Insertion Time Maximum Change Over Time Cooling Time OD OD SDR21 Clamped Cooling Time (Inches) (MM) (sec) (sec) (sec) (min) 3/8 16 4 4 6 2 ½ 20 6 4 6 2 ¾ 25 8 4 6 2 1 32 10 4 12 4 1¼ 40 12 4 12 4 1½ 50 18 4 12 4 2 63 20 6 18 6 2½ 75 22 6 18 6 3 90 25 6 18 6 4 110 30 6 24 8 SIMTECH 5

Notes Although the indicator light is off when you first insert pipe and fittings into the bushings, it will probably light as soon as the cold pipe and fitting touch the bushings. This is natural and you can proceed with your weld. Just make sure that light is off before inserting. If at the end of any weld there is any material left onto the bushing just use a clean wipe to remove it from the Teflon coated surface of the bushing. If the material is left onto the bushing after all welds performed check the following: a) Your pre-heating time (you are heating too long); b) Your temperature setting may be too high (you have a ±10 C window to adjust your temperature) WARNING: This tool operates at elevated temperature. Direct contact, even brief, with any heated parts (plates or bushings) can result in severe burns to unprotected skin. 6 SIMTECH

Notes SIMTECH 7

Simtech Industrial Products, Inc. 47-A Runway Road, Levittown, PA 19057 Phone: 215-547-0444 Fax: 215-547-9129 E-mail: info@simtechusa.com Web site: WARRANTY Simtech Industrial Products, Inc. products are warranted to be free from defects in materials and workmanship for one (1) year from date of shipment. No claim shall be permitted under this warranty unless Buyer gives Simtech Industrial Products, Inc. written notice of all respects in which Buyer claims the product to be defective. Notice must be received within ten (10) days from the date which the Buyer discovers, or should have discovered the defect. Buyer shall give Simtech Industrial Products, Inc. a reasonable opportunity to inspect the product after notice has been given. This warranty shall not apply to any products or components, which have been subjected to abnormal use, negligence or accident. Seller s sole obligation under this warranty shall be limited solely on the repair or replacement, as elected by Simtech Industrial Products, Inc., of defective or nonconforming material. To the maximum extent permitted by law, Buyer irrevocably waives all claims for money damages relating to the condition, use and performance of the goods purchased. In no event shall Simtech Industrial Products, Inc. liability exceed the purchase price of the product sold by Simtech Industrial Products, Inc. In no event, whether because of a breach of warranty or representation or any other cause, whether based upon contract, tort, warranty or otherwise, arising out of the performance or nonperformance by seller of its obligations under this agreement or with respect to the products sold pursuant here to; shall seller be liable for lost earnings, income or profits or indirect, incidental, liquidated or consequential damages. The implied warranties of merchantability and fitness for a particular purpose except as set forth in this warranty, express or implied, are hereby disclaimed and excluded. Nothing shall be construed as an additional warranty unless specifically designated as such in writing and signed by Simtech Industrial Products, Inc. Simtech Industrial Products, Inc. reserves the right, in its discretion, at any time and from time to time, to make changes to any specification, data or information contained herein. 8 SIMTECH