DATASHEET MONITORS Fire load and smoke-optimized. DATA DISPLAY GROUP

Similar documents
BLO DATASHEET FIRE LOAD AND SMOKE OPTIMIZED

Dräger VVP 1000 System Components

Significance of the Construction Products Regulation, including for data centers WHITEPAPER

TFI Report Classification

ISO INTERNATIONAL STANDARD. Non-destructive testing Penetrant testing Part 2: Testing of penetrant materials

Product data sheet Palas Fidas 200 S

Reproducible Climate...

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

ULTRASONIC TESTING DEVICE LEAK DETECTION AND CLASSIFICATION STEAM TRAP INSPECTION VALVE INSPECTION TIGHTNESS TESTING DETECTION OF PARTIAL DISCHARGES

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

_ Installation Check List

New European Fire Testing Classification for Construction Products

E-pro. Time adaptor with E-Pro Stick for thermostatic valves

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Datasheet PDCSY-MW-MD. Technical Overview. Features. Product warranty and total quality commitment. Heat Meter Integrator

AE-CU Adaptive Escape Routing for Emergency Lighting. From static to adaptive escape routing

TRACENET TM GENESIS CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

Dräger UCF 7000 Thermal Imaging Camera

PR / MP I Laboratory / Medicine

XSD Dry Cabinet

ARES-G2 Rheometer. Site Preparation Guide. Revision A Issued June 2016 Page 1

Fluke 568 Ex Intrinsically Safe Infrared Thermometer

Test Report: ICL/CR15/11/087

XSD Dry Cabinet

D-VTA 100-XX BROCHURE

XRAY SHARK XBD50/XBD51 X-Ray Inspection System for Glass-in-Glass Detection

Call stations and extensions

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Comfort Ceiling Fan Coil System INDULVENT ec. Draught-free ambient air distribution with cooling capacity up to 2600 W

Classification report

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

IECEx Certificate of Conformity

PUBLIC SUMMARY REPORT OF THE EGOLF EN 13823

BAC 4000a BAC 5000yf

IN-WALL LIFESTYLE. Lifestyle In-Wall Specification Sheet

Compact Ultra Low Temperature Chamber

NON-FLAMMABLE WALL COVERING SYSTEM FOR INNOVATIVE FIRE PROTECTION

Heating with pellets kw

Digital 7 Square Plate Magnetic Stirrer

Form: KSD-100:10 Page 1 of 3

BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION

Atlona PRO3HD Matrix Switcher Family

DSE ELECTRONIC SIRENS Advantages & Functions

BR range. B Medical Systems BR I +4 C. Blood Bank Refrigerators

LUXCOMFO TM LED Flood Light Datasheet

Remote alarm indicator and test combination MK2430

Operating Instructions

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Fire control panels FC360

Rotary Evaporators designed

For more structural safety

For more structural safety

WIDE SEARCH AREA HAND-HELD METAL DETECTION SET

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

Intelligent. Powerful.

P R O D U C T D ATA S H E E T

MFPA Leipzig GmbH Prüf-, Überwachungs- und Zertifizierungsstelle für Baustoffe, Bauprodukte und Bausysteme

OPTISENS TUR 2000 Technical Datasheet

ISO INTERNATIONAL STANDARD. Non-destructive testing Magnetic particle testing Part 2: Detection media

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY


User Manual. MS7-H550-Pro MS7-H550-S MS7-Pro MS7-S

Industrial cooling systems LT

A new wave in instrument washing and disinfection Introducing the HYDRIM G4 WD series

VIBRA-series: VIBRA, VIBRA +

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

Allure EC-Smart-Vue Sensor Series Line of communicating sensors with backlit display and graphical menus

Certificate: _01 / 22 March 2013

Downlight ENCORE DL6 15W 2700K

AEROSOL SPECTROMETERS

XRD XRD-1500 High-Temperature Oven. Innovation in Material Science...

VARIO The sleek, switching light curtain for reliable object detection and area monitoring

ISO INTERNATIONAL STANDARD. Fire-fighting hoses Rubber and plastics suction hoses and hose assemblies

Helium Leak Detector The clever and modular Solution. Simple Operation. Top Performance.

FDM273 Radio manual call point Mounting

Technical Specification and Operating Procedure PILATUS 300K

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

Operating Instructions

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

GreenCon On/Off Room Thermostat

CERTIFICATE of Product Conformity (QAL1)

SecuriSens LIST Product Catalogue 2015

Safe Enclosure Cooling

Moog Flight Simulator Visual Display. Zach Bolotin Cody Hatch Robert Swartz

performance PowerBalance, surface mounted Benefits Features Application Specifications

New dimensions in fire detection technology FlexES control: the dawning of a flexible, trendsetting system

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Product overview. Alarm indicator, operator and display panels

New European Cable Testing and Classification

Dew point set DS 400

Approved Sound Proofed Systems

OLUX LED IN-GROUND OSRAM. Datasheet

Safety Please be mindful of the following for the installation, maintenance, wiring, and related inspections:

A new wave in instrument washing and disinfection Introducing the new HYDRIM c61wd G4 series

LICENCE. to use the European Mark

Construction Products Regulation (CPR) and cables. British Cables Association Guidance to Specifiers

AMF Baffles acoustic optimising design elements for the highest requirements. Product description. Features and product properties

Transcription:

DATASHEET MONITORS 31.5-55 Fire load and smoke-optimized DATA DISPLAY GROUP www.datadisplay-group.com

Data Display Group Fireload optimized monitors - November 2017 Page 2 Safety through Fire Prevention The Data Display Group has been developing and manufacturing industrial monitors and display solutions for more than twenty years. Based on the POS-Line series, the Data Display Group has developed a series of monitors which has been specifically optimized for fire behavior and flue gas development. All plastic parts, adhesive tapes and other combustible parts have been eliminated as far as possible. The housing has been completely made of metal. In the absence of a classification system for electronic devices, the monitors were tested according to DIN EN 13501-1 using the SBI method according to EN 13823: 2015-02. The necessary fire test was carried out at the MFPA-Leipzig/Germany, which is a test body for material research and inspection authority for construction engineering industry. Tested results in accordance with the above mentioned standards were confirmed by an independent expert. The fire test has shown that the measured values are clearly below the class B-s1,d0, which makes the classification of the monitor in (B) which means hardly inflammable, and (s1) which means no or hardly flue gas development and (d0) no draining. Note: Electrical appliances cannot strictly be classified according to the standard DIN EN 13501-1 for building materials. Since an appropriate standard for electrical appliances is not available, was carried out the flammability test following DIN EN 13501-1 as a basis for comparison with building products. Displays for escape routes according B-s1,d0 NO/ BARELY smoke gas development no burning droplets INTEGRATED THERMAL SECURITY HALOGen free POWER SUPPLY FIRE LOAD Certificate Integrated PC Fire protection glass DATA DISPLAY GROUP Fire Load and Smoke Certification This monitor is a fire load and smoke gas optimized device. With this certificate we hereby confirm that it complies to the reaction to fire and fire resistance performances tolerances given below. Reaction to Fire: The flammability and combustibility stick copy of monitor label of the monitor were tested in accordance with DIN EN 13823:2010-12 (Reaction to fire tests for building products, excluding floorings, exposed to thermal attack by a single burning item) The fire trial generated results enabling the monitor to be classified within the class B-S1,d0 (DIN EN 13501-1) in all categories. It should be noted, however, that officially it is not possible to classify monitors under DIN EN 13501-1 as this norm was made for building materials originally. Fire Load performance is dependent upon the screen diagonal measurement as follows: Screen size Fire load in kwh Fire load in kg spruce wood 800.1 mm 20,04 4,175 (31.5 ) 1066.8 mm (42.0 ) 35,53 7,402 1168.4 mm (46.0 ) 39,35 8,198 1386.8 mm (54.6 ) 45,13 9,402 Germering, 28. August 2017 Hardly flammable Robust Metal chassis, VESA Dipl. Ing. Ralf Brill (MEng) Officially appointed and inaugurated expert for preventive fire protection by the Chamber of Engineers Certified expert for defensive fire protection Director of RBE Ralf Brill Engineering GmbH Axel Schäfer Head of Division Industrial Monitors Distec GmbH

Data Display Group Fireload optimized monitors - November 2017 Page 3 VGA, HDMI, DisplayPort POS-Line 31.5-55 BLO Order number DS-91-727 DS-91-729 DS-91-731 DS-91-733 Size [mm]/[inch] 800.1/ 31.5 1066.8/ 42.0 1168.4/ 46.0 1386.8/ 54.6 Type Smoke gas and fire load optimized displays with certificate. Classified according to DIN EN13501-1 as B-s1,d0 Resolution [Pixel] 1920 x 1080 (FHD) Brightness [cd/m²] 500 700 Viewing angle [ ] 165 h/ 165 v Active Area [mm] 698.40 x 392.85 930.24 x 523.26 1018.08 x 572.67 1209.60 x 680.40 Backlight Colours [M] 16.7 Contrast 3000:1 4000:1 Response time (on/off) [ms] 8 6.5 Pixel class LED ISO 9241-307 (pixel error class II) Lifetime backlight [h] 50.000 Interfaces HDCP support 1 x VGA, 1 x HDMI 1.3a, 1 x DP 1.1a, 1 x Remote OSD, 1 x OSD 4 Key Suitable operating time 24/ 7 VESA [mm] MIS-F 400 x 400 (M6) Ambient temperature operation [ C]/ [ F] 0 ~ 40/ 32 ~ 104 Operation humidity [%] 10 ~ 90 (non condensing) Ambient temperature storage [ C]/ [ F] -20 ~ 60/ -4 ~ 140 Orientation Location of connectors Location of OSD button Chassis Front bezel Glass Yes Portrait and landscape Landscape: backside down/ Portrait: backside left Landscape: backside down/ Portrait: backside left Sheet steel, powder coated, RAL 9005 (black), fine texture, matte finish, including connection cover Sheet steel, powder coated, RAL 9005 (black), fine texture, matte finish Fire protection glass, 7mm Power supply [V] AC 100-240V/ 50-60 Hz Power consumption (typ.) [Watt] 44 85 75 98 Weight [kg]/ [lb] 20.3/ 44.75 29.3/ 64.60 36.8/ 81.13 49.0/ 108.0 Dimensions (W x H x D) Conformity [mm/ inch] 762 x 456 x 117.5 30.00 x 17.95 x 4.63 994 x 587 x 117.3 39.13 x 23.11 x 4.63 1081 x 636 x 117.5 42.56 x 25.04 x 4.63 CE, EU-RoHS, B-S1, d0 nach EN13501-1 1273 x 744 x 117.5 50.12 x 29.29 x 4.63

Data Display Group Fireload optimized monitors - November 2017 Page 4 PC Intel Atom POS-Line 31.5-55 BLO Order number DS-91-965 DS-91-966 DS-91-967 DS-91-968 Size [mm]/[inch] 800.1/ 31.5 1066.8/ 42.0 1168.4/ 46.0 1386.8/ 54.6 Type Smoke gas and fire load optimized displays with certificate. Classified according to DIN EN13501-1 as B-s1,d0 Resolution [Pixel] 1920 x 1080 (FHD) Brightness [cd/m²] 500 700 Viewing angle [ ] 165 h/ 165 v Active Area [mm] 698.40 x 392.85 930.24 x 523.26 1018.08 x 572.67 1209.60 x 680.40 Backlight Colours [M] 16.7 Contrast 3000:1 4000:1 Response time (on/off) [ms] 8 6.5 Pixel class LED ISO 9241-307 (pixel error class II) Lifetime backlight [h] 50.000 PC Interfaces CPU: Intel Atom E3845 (1.9 GHz), Graphic: Intel Valleyview SoC integrated Graphics RAM: 4 GB DDR3L, Storage: min. 120 GB msata 2 x LAN 100/1000, 1 x USB 3.0, 1 x USB 2.0, 1 x HDMI, 1 x VGA, 1 x RS232 HDCP support Suitable operating time 24/ 7 VESA [mm] MIS-F 400 x 400 (M6) Ambient temperature operation [ C]/ [ F] 0 ~ 40/ 32 ~ 104 Operation humidity [%] 10 ~ 90 (non condensing) Ambient temperature storage [ C]/ [ F] -20 ~ 60/ -4 ~ 140 Orientation Location of connectors Chassis Front bezel Glass Portrait and landscape Landscape: backside down/ Portrait: backside left Sheet steel, powder coated, RAL 9005 (black), fine texture, matte finish, including connection cover Sheet steel, powder coated, RAL 9005 (black), fine texture, matte finish Fire protection glass, 7mm Power supply [V] AC 100-240V/ 50-60 Hz Power consumption (typ.) [Watt] 55 101 85 120 Weight [kg]/ [lb] 20.6/ 45.42 29.6/ 65.26 37.1/ 81.79 49.3/ 108.69 Dimensions (W x H x D) Conformity [mm/ inch] 762 x 456 x 117.5 30.00 x 17.95 x 4.63 994 x 587 x 117.5 39.13 x 23.11 x 4.63 1081 x 636 x 117.5 42.56 x 25.04 x 4.63 CE, EU-RoHS, B-S1, d0 according to EN13501-1 1273 x 744 x 117.5 50.12 x 29.29 x 4.63

Data Display Group Fireload optimized monitors - November 2017 Page 5 Mounts and Covers Accessories Product Order no. Product description Wall mount DS-91-540 Inclinable wall mount for all displays from 31.5 up to 54.6 Operating systems, Software Product Order no. Product description Windows 7 embedded 32 bit DE DS-60-645 Operation system Windows 7 embedded 32 bit EN DS-60-650 Operation system Windows 7 FES 64 bit DE DS-60-725 Operation system Windows 7 FES 64 bit EN DS-60-781 Operation system Windows 10 Pro. 64 bit DE DS-60-811 Operation system Windows 10 Pro. 64 bit EN DS-60-810 Operation system WEBPOStER DS-60-787 WEBPOStER embedded Linux

Data Display Group Fireload optimized monitors - November 2017 Page 6 DATA DISPLAY GROUP Contact Our company network supports you worldwide with offices in Germany, Austria, Switzerland, Great Britain and the USA. For more information please contact: GERMANY Distec GmbH Augsburger Str. 2b 82110 Germering GERMANY Phone +49 89 89 43 63-0 Fax +49 89 89 43 63-131 E-Mail: info@datadisplay-group.de Internet: www.datadisplay-group.de DISPLAYS MADE IN GERMANY FORTEC Elektronic AG Lechwiesenstraße 9 86899 Landsberg am Lech GERMANy Phone +49 81 91 9 11 72-0 Fax +49 81 91 2 17 70 E-Mail: sales@fortecag.de Internet: www.fortecag.de AUSTRIA FORTEC Elektronic AG Office Vienna Nuschinggasse 12 1230 Wien AUSTRIA Phone +43 1 8 67 34 92-0 Fax +43 1 8 67 34 92-26 E-Mail: office@fortec.at SWITZERLAND ALTRAG AG Bahnhofstraße 3 5436 Würenlos SWITZERLAND Phone +41 44 7 44 61 11 Fax +41 44 7 44 61 61 E-Mail: info@altrec.ch Internet: www.altrec.ch UNITED KINGDOM Display Technology Ltd. 5 The Oaks Business Village Revenge Road, Lordswood Chatham, Kent, ME5 8LF United Kingdom USA Apollo Display Technologies, Corp. 87 Raynor Avenue, Unit 1 Ronkonkoma NY 11779 United States of America Phone +44 16 34 67 27 55 Fax +44 16 34 67 27 54 E-Mail: info@displaytechnology.co.uk Internet: www.displaytechnology.co.uk Phone +1 6 31 5 80 43 60 Fax +1 6 31 5 80 43 70 E-Mail: info@apollodisplays.com Internet: www.apollodisplays.com All figures are typical values. The real values of the panel may vary. The optical characteristics are determined after the panel has been ON for approximately 30 minutes at an ambient temperature of 25 C (77 F). Life time of the backlight is defined as the time to take until the brightness reduces to 50% of its original value. Copyright 2017 Data Display Group. Information in the document is subject to change without prior notice.