User s Manual for LCD SCREEN WIRELESS ALARM SYSTEM

Similar documents
GSM Touch Screen Wireless Alarm System USER MANUAL

Touch Keypad GSM Smart Alarm System USER MANUAL

User s manual for GSM+PSTN Touch Screen Wireless Alarm System

GSM LCD Touch Keypad Wireless Intelligent Alarm System. User s manual

User Manual for GSM / LED Touch Keypad Wireless Intelligent Home Alarm System

CONTENTS. (User s Manual)

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

Wireless Home Alarm System USER MANUAL

MOBILE CALL GSM Alarm System User s Manual

SECURITY SYSTEM. User's Manual. Model: G70-ULTIMATE. K Rev. A

Profile. For a better understanding of this product, please read this user manual thoroughly before using it.

Intelligent Wireless GSM Alarm System

User Manual (LS-GSM-006)

USER S MANUAL. Profile. MOBILE CALL GSM Alarm System

GSM RFID VOICE Alarm System

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

Quick Installation Manual LED 99-Zone Autodial Wireless Alarm System

D3D Wi-Fi GSM Smart Alarm System -User Manual

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

System. For a better understanding of this product, please read this user manual thoroughly before using it.

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

WiFi GSM APP Smart Home Security System

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

Contents. Contents

Security GSM Alarm System

With Magictrl, you can control MatiGard anytime & anywhere via your smartphone, even without data network.

WiFi + PSTN. Smart Home Alarm System

S3 Sim Secual Alarm system with GSM transmitter

3 User s settings. 3.3 Internal clock setting

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

JA-63 Profi User manual

BURGLAR ALARM PANEL BS-468

S4 Combo Secual / S4 Combo Vid Secual GSM and Landline Alarm System

Vcare. User Manual. Ver WiFi - GSM- App. Smart Home Security System

USER MANUAL BEFORE INSTALLING AND USING THIS SYSTEM,

GSM Smart Home Alarm Apparatus. [99+4 defense zones] Instruction for Use

PiSector GSM Cellular Wireless Alarm System

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

1. Introduction. 2. Product overview

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

GSM-SMS-APP Smart Touch Alarm System

SA 2650 Kit User Manual

Wireless Alarm system s manual

SMART HOME SECURITY. Dual Network Communicating Alarm System with RFID INVINCIBLE. Instruction Manual. Customer Helpline

AG HOME ALARM Quick Start Guide

13. The wireless coding and timing arm and disarm settings Function Setting First / second group of time arm set 1.

Elderly Care Alarm System

1pcs. 1pcs. 2pcs 1pcs 1pcs 2pcs

Sonic Safety. Sonic Safety. Wireless Safety and Security System. HG-1500 System. For System Package OWNER S MANUAL

Contents. Glossary

The complete wirefree security alarm solution

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

reading carefully this guide, operating this system strictly on the standard procedure. System 816

1. User features of the GSM dialer

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Version 1.03 January-2002 USER S MANUAL

Auto Dialer. Manual E-921APQ E-921GPQ

SMS8 Alarm Control Panel

GSM Alarm System. S120 User Manual. Ver 1.00 Date Issued:

GSM Emergency Alarm. User s Manual. For a better understanding of this porduct,please read this user manual thoroughly before using it.

HomeSecure HS-BASIC-V2 Installation Manual: Table of Contents

CREATING SECURITY SOLUTION

GSM House Alarm System. User Manual. Ver 1.20 Date Issued:

Shenzhen SUNSKY Technology Limited

It is necessary to match all peripherals with the EVOLVEO Alarmex main unit before the first use. For safety reasons, they are not factory paired.

DIY kit alarm system. Model LYD 118 New Launch Touch Screen GSM Alarm System

Content. Chapter 1 Knowing the alarm host 1.1 Features 1.2 Technical Parameters 1.3 Packing List 1.4 Knowing the alarm host

reading carefully this guide, operating this system strictly on the standard procedure.

Watchguard WGAP864 User Manual

MG Partition 64-Zone Wireless Console with GPRS/GSM Version 1.6. Section Programming Guide

EM8710 GSM Alarm System Starter Kit

Dual-Network LCD Keyboard Intelligent Alarm

IN A BOX. User Manual YOUR HOME SECURITY SYSTEM. curv360.co.uk. Support APP remote arm/disarm, parameter settings and accessories management

GSM CAR ALARM SYSTEM USER S MANUAL


L900 series USER MANUAL

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

VAP304 PRO INSTALLATION & OPERATION MANUAL

AXI LED USER MANUAL (REV. 1.0)

DIY Home Security Support 30 numbers wireless sensors

MGE Entreprise Av. Kouwait Hammamet Tunisie Tel.1: Tel.2:

GSM SMS Controller GSM SMS Alarm Unit S130 S140 S150. User Manual

IDS816 User Manual H Issued January 2009

GSM-SD WITH CALL,SMS,MMS MANUAL

LHD8003英文安装手册 尺寸 368*207mm *豪恩安全科技/钟庭红制作. Arm Away

S6 Titan Security System. Wi-Fi and 3G GSM

TT16 RFID COLOR SCREEN INTELLIGENT GSM NETWORK ALARM SYSTEM. MODEL: KR-G19 BRAND: KERUI Secrui Electronic Co., Ltd

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

Ref.1067/032 Ref.1067/042

BURGLAR ALARM PANEL BS-468/A

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

JA-63 PROFI Alarm System MGK55402

HILLS Series LED Code Pad User Manual

0 4 / 0 4 / 1 4. GE Concord 4 Quick User Guide. GE Concord 4 Quick User Guide Page 1

S3b Sim Secual / S3b Sim Vid Secual GSM Alarm System

Wireless Keypad GKP-S8M

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

Transcription:

User s Manual for LCD SCREEN WIRELESS ALARM SYSTEM Thanks for choosing LCD screen wireless alarm system, this kit is home alarm system, can let your life to be more safe, please read carefully before use. Alarm host panel network 3 options in total: 1) PSTN network, 2) GSM network, 3) GSM+ PSTN dual network Kit include Remote controller, wireless door sensor, wireless motion sensor, wireless siren Support extra sensors digital door sensor, wireless digital motion sensors, wireless gas sensor, wireless smoke sensor, wireless indoor siren, wireless emergency button, wireless keypad Main Features Concise and elegant design with simple operating interface, CID communication protocol LCD screen with calendar, available in English, Chinese, Germany, Russian, French and Japanese etc. One-key arm operation, coding wireless sensors With 30 wireless alarm zones(each zone support up to 4 sensors), and extra 8 wired zones are optional Can preset 5 groups telephone, with functions of recording, voice indicating and monitoring Support wireless ding-dong doorbell Door chime function: during disarm status, when open door, host panel will sound fast bi bi bi to remind you. Support CID protocol. Store up to 100 alarm records and 100 arm/disarm information. Dual network and GSM network alarm host can send alarm info by SMS or phone call; PSTN network alarm host can only send alarm info by phone call; Dual network and GSM alarm host can arm/disarm system by phone call, or SMS, or wireless remote controller, or host keypad, or wireless operation keypad; PSTN alarm host can arm/disarm system by phone call, or wireless remote controller, or host keypad, or wireless operation keypad; Dual network and GSM alarm host: GSM with 3 bands (900/1800/1900 mhz) or 4 bands (850/900/1800/1900 mhz) optional. Descriptions of Host panel *Draft of alarm host (Hosts with different networks have different front panel and side view: 1) PSTN network host s front panel and side view ( as below): P gup P gdn Power L light Ala rming Light Lower Voltage/ Rec or ding Light Em ergency / B ack Spac e Number / A rm Con firm Pr ogra m Dis ar m/delete/ E sc Rec or d Pla y Antenna P ower In Out M ic B atte ry Rec ording o n/o ff 2) GSM network and Dual network host with same front panel and side view (as below):

1.1 Specifications Working voltage:100~240vac, Output current: 1A / 12VDC Operating power: 9-15VDC System wireless frequency 433.92MHz or 868.35MHz; 3 Bands 900MHz/1800MHz/1900MHz or 4 Bands 850MHz/900MHz/1800MHz/1900MHz is optional for GSM host or dual-network host; Static current: 50mA Alarm current: 500mA GSM transmission power: 2W Operating environment: Temperature: -10-50 ; Humidity:<80% Maximum available quantity of keychain remotes: 4 PCS Maximum available quantity of wireless sensors: 116 PCS Alarm host panel Dimension:180*120*38(mm) 1.2 Zone types and definitions 1.2.1 Zone types: Perimeter zone, Motion zone, Emergency zone 1.2.2 Definitions: Perimeter zone: Detecting the space like doors, windows, etc., generally use wireless door magnet sensors and wireless curtain PIR sensors Motion zone: Detecting the space like living room, aisles and bedrooms, etc., generally use wireless wide-angle PIR sensors Emergency zone: Detecting the space like Emergency area (such as emergency distress, medical rescue, gas leakage and fire alarm, etc., this zone keep 24-hour monitoring status automatically. Generally use panic button, wireless gas sensors and wireless smoke sensors. 1.3 Modes of arming: 1.3.1 Away Arm mode:once any detectors in perimeter zones or motion zones get triggered, the host will alarm immediately and meantime dial # automatically. Home Arm mode:once any detectors in perimeter zones get triggered, the host will alarm immediately and meantime dial # automatically. It will not alarm after any detectors in the motion zone are triggered. How to program and setup for the Alarm Host? 1. Prepare Prepare for landline alarm panel: Fix antenna Connect landline Switch to on from the host panel side to power on the system after you plug into outlet Prepare for GSM alarm panel and Dual network alarm panel: Use Pin or similar tools to press the SIM CARD SLOT, it can let you to install SIM card Please install a valid SIM card, replace the SIM card slot into the Alarm Host Fix GSM antenna Connect landline

Switch to on from the host panel side to power on the system after you plug into outlet Adjust GSM antenna and check the GSM signal if it is ok Below are bands options and to teach you how to check if GSM signal ok or not: GSM Signal not ok, or SIM card Bands option GSM signal ok didn t insert well 3 bands (900/1800/1900 MHZ) Indicator flash each 3 seconds Indicator flash each one second 4 bands(850/900/1800/900 MHZ) GSM signal level: If you press the or when host is in standby mode, it will show as below: GSM Signal level: XX YY XX is signal level, 2 digits, from 1~31 YY is signal status, it would say ok or no, OK means signal is ok, the host can work properly, NO means low signal, need to adjust the installation placeof the host panel Press ESC to exit, or it will exit automatically if without any operations within 30 seconds. 2. How to Setup? Notes: The host will exit programming mode if without any operation within 30 seconds It will exit to the previous menu if press ESC If enter codes by mistake for 3 times, the host panel will resume to the standby mode you can press to adjust programming info. Or to find alarming info. 3. The detailed menus in the SET are as below: Main menu Sub-Menu1 Sub-Menu2 Sub-Menu3 Sub-Menu4 Remark Set Time Set time Hour/minute/second Set Date Set date Year/Month/Day/Week Auto-dialer# s Call center Personal Nbr# SMS phone no. SMS reportng Alarming tele. Number Pls notes: Lanline host panel only with Sub-menu1 and without Sub-menu 2 ; GSM panel and Dual network panel would with both Sub-menu1 and Sub-menu2 Entry Delay Entry delay Time delay for entering Exit Delay Exit delay Time delay for exiting Siren On/Off Siren off Siren on Emergency siren Perimeter siren Motion siren Duration time of alarming User Code Enter Usercode No need to setup if separate use Upload Satus? Upload status? Yes no No need to setup if separate use Cut alarm Zone Attribute Set zone wire smart Cutwire alarm? Yes no Zone X number Zone number X Zone type Active digital door sensor? Yes NO Bypass Zone? Yes no Door status Open Close Attribute Set? Yes no Active door chime Yes No Only use for the alarm host panel which with landline For activating wireless sensors Will remind if try to arm with door left open

Program Zone number Group no. Activate Delete Activate Learning Deleting Success For Adding or deleting wireless sensor code Input wireless code User normally no need to set here Alarm History Status History XX: Button Call Failed DISARM 00: 01.01 03:39 XX: 01.01 00:08:52 For viewing alarming history records. XX means records No. For checking working records 5. More detailed information for above menu: Press SET + Enter code( the defaulted code is 888888 )+ ENT, you may see below menus: 1) Set time : This is for setting the host time. Press ENT, then press button to delete the old record + X X X X X X + ENT X X X X X X : 6 digits, means hour, minute, second, each takes 2 digits space. Such as 14:21:20, you may press 142120, now the host time will be 14:21:20. 2) Set date : This is for setting the host date. Press ENT, then press button to delete the old record + X X X X X X X + ENT X X X X X X X :7 digits,means year, month, day and week. eg:2007/01/17 4, means Jan 17th, 2007, Thursday. 0 means Sunday. 3) Auto Dialer# s : ENT + + ENT + to clean old record +input phone number + ENT + + ENT Totally 5 telephone/mobile numbers The first group is fixed for management center,other 4 groups are fixed for personal numbers Press ENT to confirm each phone(telephone/mobile) number Below are extra steps need you to set for GSM host panel and Dual network host panel in menu [Auto Dialer# s]: Press to select the report method: SMS Phone No. for voice alarming, SMS reporting for SMS alarming Notes: if you choose SMS Reporting, it will just sent to mobile numbers not include home phone numbers. Press ENT to confirm each phone(telephone/mobile) number 4) Entry delay : This is for setting delay time of disarming. Operations: ENT + Entry Delay+ press 00~59 seconds, the default is 00. 5) Exit delay : This is for setting delay time of arming Operations: ENT + is 00. 6) Alarm On/Off : button to delete old record + X X + ENT X X : 2 digits, you can set delete old record + X X + ENT X X : 2 digits,you can set 00~59 seconds, the default Here has 3 zones(emergency Zone, Perimeter Zone & Motion Zone) for your options to enable or disable the alarm when sensors trigered. Operations are as below: ENT + Emergency Zone On/Off, press to choose ON or OFF. If choose ON, the system will alarm when sensors trigered. You need to setup the alarming delay time(seconds) in the next sub-menus. Please do as following: ENT +press to delete old record + input new time X X + ENT. You can set 00~60 minutes, the default is 03 If choose OFF, just press ENT to confirm is ok. Then the system will not alarm when sensors trigered. 7) Arm/ disarm with indicator :You can set from here: ENT + + ENT, press \to choose yes or no, factory default is Yes 8) User code : ENT + press button to delete old record + X X X X + ENT X X X X : 4 digits, you can set 0000~9999. Without defaulted User Code

9) Upload status : This is for uploading Arm/Disarm/Alarm information to the Managing Centre. Operations: ENT + + ENT choose yes or no for upload or not upload. The defaulted is No. 10) Cutwire alarm? : ENT + + ENT press to choose yes or no, factory default is no 11) Zone Attribute : ENT + to clean old record + X X + ENT XX :2 digits,means zone number, Below are the Zones Attribute lists for wireless sensors programming for your reference: Zone Zone Bypass Entry Compatible Accessories Remark Number Type Zone Delay 00 ~ 01 No No Keychain remote & Keypad Emergency Smoke Alarm, 02 ~ 10 No No zone Gas Alarm& Panic button. Support up to Perimeter Door Magnet & 4 sensors per zone 11 ~ 20 No No zone Curtain PIR Motion Wide-Angle PIR 21 ~ 30 No No zone Motion Zone number : Here has 31 zonesfor your settings. 29 wireless zones(each zone supports up to 4 sensors) and 2 dedicated zones for remotes(supports up to 4 remotes or wireless keypads per zone). Each zone needs to setup Zone Type, Bypass Zone & Entry Delay. Zone type Zone type : 2 1 0, and 2 means motion zone; 1 means perimeter zone; 0 means emergency zone; sensor type :normally 2 digits type name type name type name 00 Emergency button 06 Glass sensor 12 Motion sensor 01 Emergency button 07 Motion sensor 13 Motion sensor 02 Gas sensor 08 Motion sensor 14 Other sensor 03 Smoke sensor 09 Motion sensor 15 Other sensor 04 Door sensor 10 Motion sensor 20 Doorbell button 05 Window sensor 11 Motion sensor Below is the factory default setting for sensor type: name Remote door gas controller sensor motion sensor sensor smoke sensor Factory default sensor type 00 11 21 02 03 sensor type :factory default is no Entry delay :factory default is no

12) set smart zone : from 02~38 12.1) zone number : ENT + to clear old record+ XX + ENT XX :2 digitals, 12.2) active digital door sensor : ENT + + ENT factory default is NO 12.3) Door status : ENT + + ENT 12.4) Active door chime : ENT + + ENT factory default is NO 13) program sensor : pls check details from accessories part. 14) wireless code : ENT + to clear old record + XXXXX + ENT XXXXX :5 digits,00000~99999 15) check alarm record : ENT + + ENT 16) checking working record : How to Revise Master code? This setting is for changing the Enter Code of the host. The defaulted Enter Code is 888888. If you desire to change, you may do as below: In standby mode, press SET, the screen will show Enter Code, you can input 999999 (Fixed code), press ENT, the screen will show Enter New Code, please input 6 new digits from keypad, then press ENT. Screen will show Re-enter Code, pls input this new digits again, and press ENT to confirm. Meanwhile the host panel will be back to the standby mode. Note: If input the codes 3 times by mistake, the host will be back to the standby mode automatically. How to operate the Alarm Host? Record:Slide the switch on the host panel side to ON,keep pressing and speak close to the speaker of host, and then release, the voice recorded. Play:Slide the switch on the host panel side to DC,keep pressing and you will hear the previous record. Arm:BY wireless remote:press the corresponding arm button and the host will beep once to successfully complete the operation By Host panel(keypad): 0 + master code + ENT + + ENT to choose armed home or armed away Disarm: By wireless remote: press the corresponding disarm button and the host will beep twice to successfully complete the operation By Host panel(keypad): ESC + master code + ENT the host will beep twice to successfully complete the operation Emergency: By wireless remote: Press Emergency key and the host will alarm immediately; By host panel(keypad): press,and the host will alarm immediately. Telephone alarm: After receiving the call, you will hear the recorded voice message immediately, it can be played for 30 seconds repeatedly, then follow the below instruction: 1.3.2 Input 8 to enter into the listening status for 20 seconds automatically, you can hear the alarming event sounds from phone. 1.3.3 Input # to play the recorded voice message for one time automatically 1.3.4 Input *, the host will end the call and stop dialing any auto dialer#. 1.3.5 Directly hang off the telephone, the host will end the call and automatically dial the next auto dialer#. Arm remotely by phone: 30 seconds after successfully dial the telephone number of host, enter the password of host after the beep---enter 1 after beep the host will automatically hang up after beep to successfully complete the operation. Notes: You can set Armed Away remotely by phone, but keep notes that you can t set Armed Home by this way. Disarm remotely by phone: 30 seconds after successfully dial the telephone number of host, enter the password of host after the beep---enter 0 after beep the host will automatically hang up after beep to successfully complete the operation. Check door status: if you try to arm system with door left open, alarm host panel will sound di di di di, and show you below: XX : zone number System not ready XX YYYYY YYYYY : sensor name Arm Anyway?Yes No Arm Anyway?Yes No Note:1 This only valid for digital door sensor

2 If arm by SMS or remotely by phone, just follow what we write from user s manual 3 If arm by remote controller or wireless keypad, please operate 2 times door bell:it will sound ding-dong 3 times after pressing it. This only valid when you did use wireless doorbell button Look up alarm history: press to find the Alarm history, and then press ENT to look up the previous alarm history, at most 100 pieces of history are available can be saved. Look up status history: press to find the status history, and then press ENT to look up the previous alarm history, at most 100 pieces of history are available can be saved. Alarming dialing mode: After the host goes off, it starts to repeatedly dial the auto dialer# s for three times ne by one from the first one. The answered number will not be dialed again. Power disconnection: If power got disconnected, the host panel will sound di each 8 seconds. (For GSM host panel and Dual network host panel only) SMS reporting: Mobile will get SMS like System Alarming XX, YYYY, XX means zone number, YYYY means the detailed sensor. Arm by SMS: You can edit SMS XXXXXXBF to host panel, the host panel would arm automatically when getting this SMS, and also will message back to mobile Arm successfully. Notes: Arm by SMS is only for Armed away! (For GSM host panel and Dual network host panel only) Disarm by SMS: You can edit SMS XXXXXXCF to host panel, the host panel would disarm automatically when getting this SMS, and also will message back to mobile Disarm successfully. Notes during opeartion Alarm phone dialing:it will dial one group by one group, if successfully get through, won t dial again, for the group which didn t get through, will dial 3 times in total. Exit delay:during exit delay, alarm host panel will sound di each one second; Entry delay:during entry delay, alarm host panel will sound di each one second AC fail:if AC fail,alarm host panel will sound di each 8 second; Cutwire alarm:if phone line being cut by thief, alarm host panel will sound di di each 8 seconds; Low voltage:alarm host panel will sound di di di each 8 seconds Connect wired sensors as below:(you need to connect a 2 2K resistance) 1 red + sensors +12V power input black - GND white zone 31 door sensor yellow zone 32 motion sensor blue zone 33 motion sensor green zone 34 motion sensor purple zone 35 motion sensor brown zone 36 emergency button grey zone 37 gas sensor orange zone 38 smoke sensor To understand accessories Remote 1.Features: To control the alarm host to arm and disarm. With the emergency key for urgent help. 2.Specifications: Operating power: 27A 12V alkaline battery Emitting distance: 100m (in open area) Service life: 2 years 3.Installation and Usage: For users to take along. Away Disarm Home Emergency Generally, press the Away key to arm before leaving home; and press the Disarm key to disarm; Home

is setting Armed home, please take notes that Arm Home is only effective for sensors in Perimeter Zone (door sensor\curtain PIR sensor) and sensors in Emergency Zone (Like Gas sensor\smoke sensor\glass sensor\emergency button), it is not effective all sensors in Motion zone(like wide-angle PIR). Please replace the batteries after one year usage and when you feel shorter control distance. 4.How to program Please refer to the descriptions of 3.2.13 Program in page4. Note: You can only add 1 remote each time, totally 8 available to be added. Each serial number is available to study 1 remote, the latter configured remote will be workable and the former one becomes not workable automatically. Door 1.Features: Generally set as Perimeter zone. If any door or window is opened, it will transmit the alarm signals to the alarm host. 2.Specifications: Operating power: 23A 12V alkaline battery Frequency: 433MHZ Emitting distance: 100m (in open area) Service life: 1 year Alarm Distance: <4cm 3.Installation and Usage Fix the part of magnet onto the door frame in a position of 1.6m above the ground to prevent any children from bumping onto it Fix the part of emitting onto the door frame, make sure to keep the part of magnet and part of emitting in parallel, the space between the two parts shall be less than 10mm Upon the working light flashes frequently in red, please replace the batteries 4.How to program Please refer to the descriptions of 3.2.13 Program in page4. Note: You can only add 1 wireless door magnet each time, totally 4 available to be added. Each serial number is available to study 1 wireless door magnet, the latter configured wireless door magnet will be workable and the former one becomes not workable automatically. wide-angle PIR (Address code: D0~D3:1101)

Working Light D0 021 Lens On / Off Low-Votage Light D3 Power Switch Down/Off Up/On Learning Emitting Switch Jump Line Install the bracket Fix the PIR by pushing it downwards Keep the switch "on" Wall Wall Wall 1.Features: Mainly monitor and control indoor space, generally set as Motion zone. When human body enters into etecting area, the sensor will transmit alarm signals to the alarm host. 2.Specifications: Operating power: 9V alkaline battery Emitting distance: 100m (in open area) Service life: 1 year Detecting distance: 110 10 10m 3.Installation and Usage Fix the bracket on suitable wall surface or in wall corner at a distance of 2~2.4m above the ground; Open the sensor shell to connect the batteries well and adjust jumper line (short circuit 5S : The sensor will detect once every 5 seconds; short circuit 5MIN : The sensor will detect once every 5 minutes; Suggestion: short circuit 5S for testing and 5MIN for normal use; Fix the sensor onto the bracket; Adjust the sensor to a proper angle and then slide the power switch on the side to ON, and it will enter into the normal working state after 30 seconds; Upon the working light flashes frequently in green, please replace the batteries. 4.How to program Please refer to the descriptions of 3.2.13 Program in page4. Note: You can only add 1 wireless wide-angle PIR sensor each time, totally 4 available to be added. Each serial number is available to study 1 wireless wide-angle PIR sensor, the latter configured wireless wide-angle PIR sensor will be workable and the former one becomes not workable automatically. Indoor Siren 1. Functions Features: 1.1 Work with alarm host, wireless receiving alarm signals, spot alarming with sound and flash 1.2 With power plug, usually for indoor use. 2. Specifications: 2.1 Operating Power: 100 240VAC 2.2 Receiving Distance: 100 M(In open area) 3. Installation and Usage: 3.1 Plug the wireless siren into suitable indoor power socket 3.2 Suggestion: Generally around 1.8M from the ground

4. How to program accessories A. Activate 4.1 After connecting to the power, press the Learning switch on the side of the siren, siren lights on 4.2 Press key on the alarm host, then disarm by keypad on the alarm host (press 0, input programming password, press ENT, the sound of Di Di from the alarm host indicates successful disarm operation) after five seconds. 4.3 Light on the siren flashes 5 times and then off indicates successful adding. B. Deactivate 4.1 After connecting to the power, keep pressing the Learning switch on the side of the siren for 5 seconds and release, light on the siren flashes 2 times and then off indicates successful cancelling. Notes: 1. You can only add 1 wireless siren each time. 2. When configure the wireless siren, you can only operation on the keypad of the alarm host. 3. One siren can be studied to at most 10 wireless alarm hosts, multi wireless sirens are available to be added for each alarm host. 学习按键 学习按键的英文是 :STUDY BUTTON Preview of how to activate and deactivate Basic accessories and Optional accessories Type Zone No. Max. no. to be programmed How to activate How to deactivate Basic accessories Remote 00 01 8 door sensor 11~20 4 1) SET +Programming code + Program sensor + ENT + + Y Y + ENT + + X + ENT + Activate sensor + ENT ( The screen would say learning) 2) Press any key on the remote twice successively, the host LCD will display Success ; 1) Same as above 2) Trigger the door magnet sensor twice successively 1) SET +Programming code + Program sensor + ENT + + Y Y + ENT + + X + ENT + Delete sensor + ENT 2) The alarm host will beep once and press ESC to exit. Same as above Wide-Angle PIR sensor 21~30 4 1) Same as above 2) Trigger the PIR sensor by pressing Learning Emitting Switch on the panel twice successively Same as above

Curtain PIR sensor 11~20 4 1) Same as above 2) Trigger the PIR sensor by pressing Learning Emitting Switch on the panel twice successively Same as above Indoor siren N/A 1) After connecting to the power, press the learning switch on the side of the siren 2) Press key on the alarm host, then disarm b keypad on the alarm host 3) Light on the siren flashes 5 times and then off indicates successful activating After connecting to the power, keep pressing the Learning switch on the side of the siren for 5 seconds and release, light on the siren flashes 2 times and then off indicate successful deavtivating Gas alarm 02~10 4 1) Same as above 2) Trigger wireless gas alarm by releasing smoke, the host LCD will display Success Same as above Optional Accessories Smoke Remote Keypad Outdoor Siren 02~10 4 00 01 8 1) Same as above 2) Press any key on the remote controller twice successively, the host LCD will display success 1) Same as above 2) Press any key on the remote controller twice successively, the host LCD will display success Same as above Same as above N/A Same as wireless indoor siren Same as wireless indoor siren Common Problems and Solutions Symptoms of Faults Possible Cause Solution The alarm host goes off immediately after connected to the power The telephone incoming line has not been connected or not well connected. Connect the telephone incoming line well. The alarm host can t automatically record or can t record completely Repeatedly receiving the alarm telephone The host does not alarm after the detector is triggered in arm state The PIR sensor doesn t work The detecting distance of PIR sensor gets shorter The host does not alarm after the new added wireless detector is triggered. The PIR sensor flashes frequently in green. The door magnetic sensor indicator flashes frequently in green after alarming. The distance of the remote controller gets shorter. The record switch is not on; The Record key is being pressed while recording Fail to operate according to the operation instruction of the telephone alarm 1. Caused by the functions of arm mode (Armed Away and Armed Home); 2. Have already setup time for Entry Delay or Exit Delay 1. Not connected to the power 2. Port of the detector is in the power-down mode. The ambient temperature in the detecting area is too high. Failed to follow the operation instruction of Adding and deleting sensors to add the new wireless sensor Batteries are running out. Batteries are running out. Batteries are running out. 1. Slide the record switch to ON ; 2. Keep pressing the RECORD key while recording. Follow the below instructions after answering the alarm phone calls and hearing the recorded message: (See 2.5 Operation --- Telephone alarm) 1. Armed Away mode: the alarm goes off when any sensor is triggered; 2. Armed Home mode: the alarm goes off when any sensor in 1 st Defense Line is triggered and it won t alarm when any sensor in 2 st Defense Line is triggered 3. Program to adjust the time for Entry Delay or Exit Delay 1. Open the sensor shells to install the batteries well and slide the power switch to On ; 2. 5S : detect once every 5 seconds; 5MIN : detect once every 5 minutes; When the ambient temperature in the detecting area exceeds the human body temperature, the detecting distance will get shorter, it s normal. Follow the operation instruction of How to program to activate the new wireless sensor Replace with new batteries of the same specification. Replace with new batteries in the same specification. Replace with new batteries in the same specification.

Daily Maintenance and Care This alarm is the hi-tech product with the outstanding design and sophisticated technique, and shall be used carefully. To make the alarm to operate for a long term stably and to prolong the service life, it is recommended that: Try to put the alarm host in the dry and well-ventilated places. Do not put the host and any wireless detectors in too cold, too hot or dusty places to prevent it from curtailing the service lives of electric parts and preventing the plastic shell from distorting and accelerating to age. Do not put the host and any wireless detectors in low and too exposed places to prevent the children from touching them or the thieves from finding them. Regular testing is necessary for finding and resolving problems in time. Regularly check the batteries in all wireless sensors and replace the running out batteries to ensure the normal operation of them. You d better keep the power of the alarm host and all wireless accessories off while a long-time vacancy of the system.