TECHNICAL REPORT Crimp Splice Protection -250M/P150 mark 2

Similar documents
Product Specification Qualification Test Report

/Mar/2014 Rev A

ETSI TS V1.2.1 ( )

23" PANEL MOUNT INDUSTRIAL MONITOR REVISION C PRODUCT RELIABILITY TEST REPORT

17" UNIVERSAL MOUNT INDUSTRIAL MONITOR REVISION E, F & G PRODUCT RELIABILITY TEST REPORT

Technical Specification for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C)

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

Ensuring Cabling Performance in the Customer-Owned Outside Plant

Draft ES V1.1.1 ( )

ITU-T L.404. Field mountable single-mode optical fibre connectors

Fujikura-70S Single Fibre Fusion Splicer

ETSI TS V1.2.1 ( )

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Technical Specification for the Gel-Sealed Fiber-Optic Closure System (FOSC 450)

Fibrlok II 2529 Universal Optical Fiber Splice

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

Return loss measurement of fiber optic components

Test Report for Senko Advanced Components, Report No RES3005 February 22, Test Report. Senko Advanced Components

CERTIFICATE of QUALITY TEST

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

Basic Professional Fiber Optic Installation

ITU-T L.12. Optical fibre joints SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

STANDARD TEST PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS TYPE OF CABLE :

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Product Tests Report

Qualification Test Report LC Duplex Adapter For LC Cutouts

Laser Collimated Beam Sensor

COMITÉ EUROPÉEN DES ASSURANCES

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

Product Test report. Security Systems TO WHOM IT MAY CONCERN. Bosch Security Systems Torenallee 49 Eindhoven 5617 BA The Netherlands AT18-Q1616

Vibration tests on a TNAML Luminaire

PRODUCT SPECIFICATION. 0.5mm Fine Stacking. Hermaphroditic Type BTB Connector

Jul07 Rev C

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

Jan07 Rev B

Fiber Optics for Todays Industry Applications

Free Height 0.8 mm Pitch Board-to-Board Connector (SMT)

ASSMANN ELECTRONIC GmbH ASSMANN SYSTEM GUARANTEE. DIGITUS Professional Fiber Optic Cabling System. Appendix B - Provisions for acceptance

Smoke and heat control systems - Part 10: Power supplies EN Classification according to operational and environmental class

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

ENVIRONMENTAL TEST REPORT

Product Specification EMI Shielded Duplex LC Sealed Receptacle (ODVA Conforming)

F3UV. Monitoring output state of UV (ultraviolet light)/illumination light source. Ultraviolet power monitor/illumination monitor.

Apr06 Rev A

OFS IV Optical Fibre System

Fiber Optic Products Catalog

Savitri Telecom Services

Reflectance, The Hidden Danger That Increases Bit Error Rates in Your Fiber Networks Denver, May 22nd, 2010

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

M700-Series Multifunction OTDR

Fibre Optic Basics FIA Summer Seminar 2014

Accelerating NBN fiber testing. Tom Ronan Marketing Lead Fiber Optics Melbourne

Report No 288/ Part 1 of 2 This report consists of 22 pages. Maxitone ZAMT Type A Addressable Sounder. See Assessment Summary for details

FTTHARCFUSIONSPLICER AD620

Equipment specifications (D6)

This is to certify that the optical output of the: SENSORNET LR-DTS Temperature Sensing System: (Variants Mark 1, Mark 2a and Mark 2b)

HELKAMA. Optical Fibre Cables

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Qualification Test Report LightCrimp* Plus Singlemode and Multimode LC Connector (Field Installable)

2016 CDM Smith All Rights Reserved July 2016 SECTION FIBER OPTIC DATA NETWORK

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

UC INSTRUMENTS GM8036 LASER SWEEP OPTICAL SPECTRUM ANALYZER (1525 ~ 1610 nm) Technical Specifications v1.01 March, 2011


Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

Fiber Optic Patch Cord and Pigtails

OPTICAL FIBER SOLUTIONS

Class 1 laser beam sensor safe for your eyes

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Sumitomo T-39 Core Aligning Fusion Splicer

NBS Smoke Density Chamber

SPECIFICATION OF ANALOG MEMS MICROPHONE. ( Ultra Mini Top Port ) MODEL NO. : F1-(A)MOE-C110T42-4CP

Class 1 laser beam sensor safe for your eyes

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

Nardalert S3 TM Non-Ionizing Radiation Monitor

Fibre Specification Standards

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR FUSION SPLICE AND SPLICE ENCLOSURE FIBER OPTIC CABLE

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

Class 1 laser beam sensor safe for your eyes

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

PONA Rack Mounted Erbium Doped Fiber Amplifier. User s Manual r001 August 30, W. Chestnut St Alhambra, CA 91803

Thermal Stripper, TSFB-125 User Manual

Fibre (TIA) Field Test Specification

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

High cost performance choice

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

Hands-On CAT 5/6 & Fiber Optic Installer

FT10Aseries. Self-check feature provided. Fiber type / CMD. Within detecting distance 40 m

M7100 Pressure Transducer

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

G155PU001S. Pigtailed 14-PIN DIL Laser Diode with TEC. FLMS Min. Typ. Max.

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

Transcription:

FIBER OPTIC TECHNOLOGY CALIBRATION LABORATORY Document number: TZ_2_7_PP_EN_splice TECHNICAL REPORT Crimp Splice Protection -25M/P15 mark 2 E.G. Tec Ltd. Date: May-1-27

TZ_2_7_EN_splice Contents: 1. General... 2 2. Description... 2 3. Tested Supplier of Crimp Splice Protection... 2 4. Summary... 3 5. Crimp Splice Protection Specifications...4 5.1. Dimensions... 4 6. Process preparing of samples... 5 7. Test Method... 5 7.1. Insertion Loss (IEC 874-1, 4.4.7.4 method 7)... 5 8. Environmental tests... 6 8.1. Dry Heat (DIN EN 613-2-18)... 7 8.2. Cold (DIN EN 613-2-17)... 8 8.3. Damp Heat (DIN EN 613-2-19)... 9 8.4. Change of Temperature (DIN EN 613-2-22)... 1 9. Mechanical performance... 11 9.1. Vibration (DIN EN 668-2-6)... 11 9.2. Shock (EN 668-2-27)... 18 9.3. Bending test, flat (Deutche telekom, T-Com, TS 338/96)... 2 9.4. Bending test, on edge (Deutche telekom, T-Com, TS 338/96)... 22 9.5. Pulling test ( Deutche Telecom, T-Com, 2.61)... 25 1. Appendix... 27 1. General This technical report describes tests of the CSP-25M/P15 mark 2 crimp splice protection including environmental and climatic requirements and mechanical tests. 2. Description The Crimp Splice Protection CSP-25M/P15 mark 2 (new version) offers a mechanical and environmental protection for fiber optic joints. The aluminum crimp splice is re-coated with adhesive mastic and simply folded around the spliced fibers, using crimping tool. It does not require the application of heat after fusion splicing. The splice loss is not affected by using the crimp splice protector. All types of fibers with a primary protection 25μm are process able in the splice protector. 3. Tested Supplier of Crimp Splice Protection E.G. Tec Ltd. Contact person: Mr. Gaby Engel Units 325&6 Ystradgynlais Workshops Trawsffordd Powys SA9-1BS United Kingdom http://www.egtec.co.uk/ OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com Page 2 from 27

TZ_2_7_EN_splice 4. Summary Requirements fulfilled: YES / PASSED TABLE OF RESULTS TEST STANDART RESULT Dry Heat EN 613-2-18 PASSED Cold EN 613-2-17 PASSED Damp Heat EN 613-2-19 PASSED Change of temperature EN 613-2-22 PASSED Vibration EN 668-2-6 PASSED Shock EN 668-2-27 PASSED Bending test flat Deutche telekom, T-Com, TS 338/96 PASSED Bending test - height Deutche telekom, T-Com, TS 338/96 PASSED Pulling test Deutche telekom, T-Com, 2.61 PASSED The tests performed are documented on following pages. All test results are within specifications. Samples passed all required test and we recommend releasing certificate of conformity. OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com Page 3 from 27

TZ_2_7_EN_splice 5. Crimp Splice Protection Specifications Dimensions (W x H x L) - closed 1.1 x 3.2 x 3 mm Material Aluminum marine type rust free polished Adhesive Modified PIB Fiber diameter max 25 µm Cleave length 2 mm Operating temperature 25 C to +7 C Installation time less then 3 seconds Processing Temperature -5 C to +45 C Recommended crimping tool BOSCH Crimp Tool: CT-25M 5.1. Dimensions Dimensions (W x H x L) - closed 1.1 x 3.2 x 3 mm Picture 1 Crimp protection, packaging Page 4 from 27 OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com

TZ_2_7_EN_splice 6. Process preparing of samples Splicing two pigtails. All splices were inserted into randomly chosen crimp splice protection and crimped. Insertion the splice protection into splice holder. Insertion the splice holder into test equipment (climatic chamber or mechanical test equipment) Setting reference. Starting test and attenuation of the splice at splice protection was measured. Type of optical fiber: Single mode 9/125, G652C type Type of fusion splicer: Furukawa S176, SN: 111 The initial Insertion loss shall be measured: IL.1 db All tests were performed by using the standard G.652C single mode fiber at 3 samples for each test. 7. Test Method 7.1. Insertion Loss (IEC 874-1, 4.4.7.4 method 7) The test samples shall be measured in the following system According to IEC 874-1, 4.4.7.4 (Picture 2) The Insertion Loss (IL) is defined as P 1 IL = - 1 log ----- Light Source Master P (db) P Optical Power Meter Photo Detector Picture 2 Insertion Loss (IEC 874-1, 4.4.7.4 method 7) First step Read of reference value P Second step Replace the Master Patch cord by set of two spliced pigtails, read the value P1. OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com Page 5 from 27

TZ_2_7_EN_splice 8. Environmental tests Climatic chamber: Power meter and light source: Climatic temperatur systeme, Germany Type CTS -4/6 SN: 2771 JDS Uniphase, Canada Type: RX3B+1121SUT SN: AD47486 Environmental tests were performed in Climatic Chamber refer to Picture. 3: LD Light Source Optical Power Meter Chamber Photo Detector Picture 3 Measurement system, climatic chamber Page 6 from 27 OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com

TZ_2_7_EN_splice 8.1. Dry Heat (DIN EN 613-2-18) Method DIN EN 613-2-18 Wavelength 155 nm Temperature +85 C Duration of exposure 96 h Samples tested 3 Measurements Before, during (interval 1 min) and after test Tests criteria Any visual damaging or deformation shall be noticed. Change of attenuation must be less or equal than.1 db to the initial value. 8.1.1. Results of Dry Heat test Maximum value of IL (db) 155 nm:.5 Minimum value of IL (db) 155 nm:. Limit value of IL (db) 155 nm:.1 Temperature (deg C) 9 8 7 6 5 4 3 2 1 :: 1:: 2:: Dry heat (DIN EN 613-2-18) 3:: 4:: 5:: 6:: 7:: 8:: 9::.6.5.4.3.2.1 IL(dB) 155 nm Time (hrs) Temperature Sample 1 Sample 2 Sample 3 Picture 4 Graph of Dry Heat Result: PASSED Comments: Graph displays temperature on the left side, IL (db) 155nm on the right side, axis X shows time. All tested specimens passed Dry Heat test (DIN EN 613-2-18). OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com Page 7 from 27

TZ_2_7_EN_splice 8.2. Cold (DIN EN 613-2-17) Method DIN EN 613-2-17 Wavelength 155 nm Temperature -4 C Duration of exposure 96 h Samples tested 3 Measurements Before, during (interval 1 min) and after test Tests criteria Any visual damaging or deformation shall be noticed. Change of attenuation must be less or equal than.1 db to the initial value. 8.2.1. Results of Cold Test Maximum value of IL(dB) 155 nm:.7 Minimum value of IL(dB) 155 nm:. Limit value of IL(dB) 155 nm:.1 Cold (DIN EN 613-2-17) Temperature (C) 3 2 1-1 -2-3 -4-5 :: 2:: 4:: 6:: 8:: Time (hrs) Temperature Sample 1 Sample 2 Sample 3.8.7.6.5.4.3.2.1 IL (db) 155 nm Picture 5 Graph Cold (DIN EN 313-2-17) Result: PASSED Comments: Graph displays temperature on the left side, IL(dB) 155nm on the right side, axis X shows time. All tested specimens passed Cold test (DIN EN 613-2-17). OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com Page 8 from 27

TZ_2_7_EN_splice 8.3. Damp Heat (DIN EN 613-2-19) Method DIN EN 613-2-19 Wavelength 155 nm Temperature +4 C Duration of exposure 96 h Relative humidity 93 ± 2% Samples tested 3 Measurements Before, during (interval 1 min) and after test Tests criteria Any visual damaging or deformation shall be noticed. Change of attenuation must be less or equal than.1 db to the initial value. 8.3.1. Results of Damp Heat test Maximum value of IL(dB) 155 nm:.5 Minimum value of IL(dB) 155 nm:. Limit value of IL(dB) 155 nm:.1 Temperature (deg C) 45 4 35 3 25 2 15 1 5 :: 1:: Damp heat (DIN EN 613-2-19) humidity 93% 2:: 3:: 4:: 5:: 6:: 7:: 8:: 9::.6.5.4.3.2.1 IL(dB) 155 nm Time (hrs) Temperature Sample 1 Sample 2 Sample 3 Picture 6 Graph Damp Heat (DIN EN 313-2-19) Result: PASSED Comments: Graph displays temperature on the left side, IL (db) 155nm on the right side, axis X shows time. All tested specimens passed Damp Heat test (DIN EN 613-2-19) OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com Page 9 from 27

TZ_2_7_EN_splice 8.4. Change of Temperature (DIN EN 613-2-22) Method DIN EN 613-2-22 Wavelength 155 nm Low Temperature -4 C High Temperature +7 C Duration at extreme temperature 1 h Rate of change of temperature 1 C/min Duration 96 hrs Samples tested 3 Measurements Before, during (interval 1 min) and after test Tests criteria Any visual damaging or deformation shall be noticed. Change of attenuation must be less or equal than.1 db to the initial value. 8.4.1. Results of Change Temperature test Maximum value of IL(dB) 155 nm:.6 Minimum value of IL(dB) 155 nm:. Limit value of IL(dB) 155 nm:.1 Temperature (deg C) 8 6 4 2-2 -4-6 :: 1:: Change temperature (DIN EN 613-2-22) 2:: 3:: Temperature sample 1 sample 2 sample 3 4:: 5:: Time (hrs) 6:: 7:: 8:: 9::.7.6.5.4.3.2.1 IL(dB) 155 nm Picture 7 Graph Change of Temperature (DIN EN 313-2-22) Result: PASSED Comments: Graph displays temperature on the left side, IL (db) 155nm on the right side, axis X shows time. All tested specimens passed Change temperature test (DIN EN 613-2-22 OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com Page 1 from 27

TZ_2_7_EN_splice 9. Mechanical performance 9.1. Vibration (DIN EN 668-2-6) Method DIN EN 668-2-6 Wavelength 155 nm Double amplitude 1.5 mm p-p Frequency 1 5 Hz octave/min Duration 3 min (18 sec) per each axe Axes 3 Samples tested 3 Tests criteria Any visual damaging or deformation shall be noticed. Change of attenuation must be less or equal than.1 db to the initial value. Equipment: Gearing and Watson Power amplifier SS15 Vibrator type GWV 3 Vibration control system VCS1 S/N: 4616 Sample Picture 8 Figure of Vibration test Page 11 from 27 OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com

TZ_2_7_EN_splice Picture 9 Samples fixed on Vibration equipment 9.1.1. Results of Vibration test (DIN EN 668-2-6) Maximum value of IL(dB) 155 nm:.2 Minimum value of IL(dB) 155 nm:. Limit value of IL(dB) 155 nm:.1 The splice protections were fixed at holder. Holder was fixed to vibration equipment and test was started. Continuance of frequency (vibration test) Frequency (Hz) 6 5 4 3 2 1 12 24 36 48 6 72 84 96 Time (sec) 18 12 132 144 156 168 18 Picture 1 Graph continuance of frequency, f [Hz] Page 12 from 27 OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com

TZ_2_7_EN_splice 9.1.2. X axis Vibration (EN 668-2-6) Sample 1, X axis.5.4 IL(dB) 155nm.3.2.1 1 2 3 4 5 6 7 8 9 Time (sec) Vibration (EN 668-2-6) Sample 2, X axis 1 11 12 13 14 15 16 17.5.4 IL(dB) 155nm.3.2.1 1 2 3 4 5 6 7 8 9 Time (sec) 1 11 12 13 14 15 16 17 Page 13 from 27 OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com

TZ_2_7_EN_splice Vibration (EN 668-2-6) Sample 3, X axis.5.4 IL(dB) 155nm.3.2.1 9.1.3. Y axis 1 2 3 4 5 6 7 8 9 Time (sec) 1 11 12 13 14 15 16 17.5 Vibration (EN 668-2-6) Sample 1, Y axis.4 IL(dB) 155nm.3.2.1 1 2 3 4 5 6 7 8 OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com 9 Time (sec) 1 11 12 13 14 15 16 17 Page 14 from 27

TZ_2_7_EN_splice.5 Vibration (EN 668-2-6) Sample 2, Y axis.4 IL(dB) 155nm.3.2.1.5 1 2 3 4 5 6 7 8 Time (sec) Vibration (EN 668-2-6) Sample 3, Y axis 9 1 11 12 13 14 15 16 17.4 IL(dB) 155nm.3.2.1 1 2 3 4 5 6 7 8 Time (sec) 9 1 11 12 13 14 15 16 17 Page 15 from 27 OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com

TZ_2_7_EN_splice 9.1.4. Z Axis.5 Vibration (EN 668-2-6) Sample 1, Z axis.4 IL(dB) 155nm.3.2.1 1 2 3 4 5 6 7 8 9 Time (sec) Vibration (EN 668-2-6) Sample 2, Z axis 1 11 12 13 14 15 16 17.5.4 IL(dB) 155nm.3.2.1 1 2 3 4 5 6 7 8 Time (sec) 9 1 11 12 13 14 15 16 17 Page 16 from 27 OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com

TZ_2_7_EN_splice Vibration (EN 668-2-6) Sample 3, Z axis.5.4 IL(dB) 155nm.3.2.1 1 2 3 4 5 6 7 8 Result: 9 Time (sec) PASSED 1 11 12 13 14 15 16 17 Comments: All tested specimens passed Vibration test (DIN EN 668-2-6). Page 17 from 27 OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com

TZ_2_7_EN_splice 9.2. Shock (EN 668-2-27) Method EN 668-2-27 Wavelength 155nm Acceleration 15g, half sinus shape Number of axes 3 Time 11ms Samples tested 3 Tests criteria Any visual damaging or deformation shall be noticed. Change of attenuation must be less or equal than.1 db to the initial value. Test equipment see Appendix 1, Test report from VTUPV(military technical institute) Vyskov, Czech republic. The splice protections were fixed at holder. Holder was fixed to vibration equipment and test was started. Shock wave was performed three times for minus shock pulse and three times for plus shock pulse (see Picture 13.) IL was monitored during shock test. Picture 11 Pictures of shock test equipment Picture 12 Simulation wave of acceleration by software for shock test control OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com Page 18 from 27

TZ_2_7_EN_splice Shock pulse Acceleration "G" (m2/sec) 1 5 -,1 -,5-5,5,1-1 -15-2 Shock 9.2.1. Results of Shock test Maximum value of IL(dB) 155 nm:.1 Minimum value of IL(dB) 155 nm:. Limit value of IL(dB) 155 nm:.1 Picture 13 Real run of Shock pulse sample 1, X axis sample 2, X axis sample 3, X axis sample 1, Y axis sample 2, Y axis sample 3, Y axis sample 1, Z axis sample 2, Z axis sample 3, Z axis IL (db) 155 nm minus pulse minus pulse minus pulse plus pulse plus pulse plus pulse 1 2 3 1 2 3...1.....1...1.......1..............1...1.....1....1.1......... Table 1 IL (db) 155 nm at Shock test Result: PASSED Comments: Changes of attenuation during Shock test are very low and all samples passed set limit, see Table 1 OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com Page 19 from 27

TZ_2_7_EN_splice 9.3. Bending test, flat (Deutche telekom, T-Com, TS 338/96) Span 24 mm Pins radius diameter 5 mm Length 1,4 mm Load 2N Number of cycles 3 Temperature 2 C Maximum allowed different from initial value Width ±,2mm Height ±,2mm Measuring equipment Caliper digital, Garant 15 mm, accuracy.1 mm SN: 412611/15 Dial gauge SOMET 251811, accuracy.1 mm The splice protection is compressed without fiber. Afterwards, the splice protector is measured (width, height) The splice protector is placed horizontally and on the edge in the centre of the abutment. The stamp presses on the center of splice protection. After exertion of the load, the splice protection is measured again. Finally the test is repeated for every sample. Picture 14 Figure of bending test, flat Picture 15 Bending test - flat. Setting and measuring OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com Page 2 from 27

TZ_2_7_EN_splice 9.3.1. Result of bending test, flat Deflection (mm) SAMPLE before during force 2N after test sample 1.19.4 sample 2.19.2 sample 3.19.4 Table 2 Deflection, bending test, flat Bending test - flat.2.18.16.14 Deflection (mm).12.1.8.6 Sample 1 Sample 2 Sample 3.4.2 before during force 2N after test Picture 16 Graph of bending test, flat Width (mm) Height (mm) before after before after sample 1 1.22 1.23 3.5 3.3 sample 2 1.19 1.2 3.4 3.2 sample 3 1,18 1.18 3.3 3.2 Table 3 Dimension of splice protection before and after bending test, flat Result: PASSED Comments: All samples passed initial requirements. Page 21 from 27 OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com

TZ_2_7_EN_splice 9.4. Bending test, on edge (Deutche telekom, T-Com, TS 338/96) Span 24 mm Pins radius diameter 5 mm Length 1.4 mm Load 6N Number of cycles 3 Temperature 2 C Maximum deviation ±.2mm The splice protection is compressed without fiber. Afterwards, the splice protector is measured (width, height) The splice protector is placed horizontally and on the edge in the centre of the abutment. The stamp presses on the center of splice protection. After exertion of the load, the splice protection is measured again. Finally the test is repeated for every sample. Picture 17 Bending test, on edge Picture 18 Bending test - on edge. Setting and measuring. Measuring equipment Caliper digital, Garant 15 mm, accuracy.1 mm SN: 412611/15 Dial gauge SOMET 251811, accuracy.1 mm OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com Page 22 from 27

TZ_2_7_EN_splice 9.4.1. Result of bending test, on edge Deflection (mm) SAMPLE before during force 6N after test sample 1.17.2 sample 2.11.4 sample 3.9.4 Table 4 Deflection, bending test, on edge Bending test - on edge.2.18.16.14 Deflection (mm).12.1.8 Sample 1 Sample 2 Sample 3.6.4.2 before during force 6N after test Picture 19 Graph of bending test, on edge Page 23 from 27 OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com

TZ_2_7_EN_splice Width (mm) Height (mm) before after before after sample 1 1.24 1.22 3.4 3.2 sample 2 1.18 1.2 3.5 3.4 sample 3 1.16 1.18 3.1 3.2 Table 5 Dimension of splice protection before and after bending test, on edge Comments: Result: PASSED All samples passed initial requirements. Page 24 from 27 OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com

TZ_2_7_EN_splice 9.5. Pulling test ( Deutche Telecom, T-Com, 2.61) Force Speed of pulling Duration Tests criteria 7N 5mm / min 6 sec Any visual damaging or deformation shall be noticed. Change of attenuation must be less or equal than.1 db to the initial value. Crimp protection was inserted into clamp see Picture 21. One end of fiber was fixed on valve (weight 7 N). Clamp was fixed with pulling equipment. Picture 2 Workstation for pulling test with JDSU multimeter Picture 21 Span with crimp protection Page 25 from 27 OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com

TZ_2_7_EN_splice Pullling test.5.4 IL (155 nm) db.3.2.1 1 s 2 s 3 s 4 s 5 s 6 s Time (sec) Series1 Series2 Series3 Picture 22 Graph of pulling test IL (155nm ) db Time Sample 1 Sample 2 Sample 3 1 s 2 s.2 3 s.1.3 4 s.1.1.3 5 s.2.1.4 6 s.2.4 Table 6 Results of pulling test Result: PASSED Comments: All samples passed initial requirements. Page 26 from 27 OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com

TZ_2_7_EN_splice 1. Appendix Appendix 1 Test report for mechanical resistibility, Shock test, VTUP Vyškov, Czech Republic 3 pages, separate document. Test undertaken by: OPTOKON Co., Ltd. Cerveny Kriz 25 582 2 Jihlava Czech Republic Checked by: Pavel Pospíchal, Head of Technical Support www.optokon.com optokon@optokon.cz tel.: +42 564 4 111 fax +42 564 4 134 Approved by: Aleš Weselý, Quality Manager +42 567 311 292 Page 27 from 27 OPTOKON Co., Ltd. Cerveny Kriz 25, 586 2 Jihlava, Czech Republic tel. +42 564 4 111, fax +42 564 4 134, +42 567 311 292, optokon@optokon.cz, www.optokon.com